1. Flow Preservation of Umbilical Vein for Autologous Shunt and Cardiovascular Reconstruction.
- Author
-
Hoganson DM, Cooper DA, Rich KN, Piekarski BL, Gui L, Gaut JP, Mayer JE, Aikawa E, Niklason LE, and Emani SM
- Subjects
- Biopsy, Needle, Cardiac Surgical Procedures methods, Female, Humans, Immunohistochemistry, Infant, Newborn, Male, Microscopy, Electron, Scanning methods, Sensitivity and Specificity, Tissue and Organ Harvesting methods, Transplantation, Autologous methods, Umbilical Veins surgery, Umbilical Veins ultrastructure, Endothelium, Vascular diagnostic imaging, Endothelium, Vascular physiology, Organ Preservation Solutions chemistry, Plastic Surgery Procedures methods, Tissue Preservation methods, Umbilical Veins transplantation
- Abstract
Background: Synthetic graft materials are commonly used for shunts and cardiovascular reconstruction in neonates, but are prone to thrombosis and scarring. The umbilical vein is a potential source of autologous, endothelialized tissue for neonatal shunts and tissue reconstruction, but requires preservation before implantation., Methods: Umbilical cords were collected in UW solution with antibiotics at 4°C until dissection. Umbilical vein segments were tested for burst pressure before and after 2 weeks of preservation. Umbilical veins segments were preserved under static or flow conditions at 4°C in UW solution with 5% human plasma lysate for 7 days. Veins were evaluated with histopathology, scanning electron microscopy, and platelet adhesion testing., Results: Umbilical veins have no difference in burst pressure at harvest (n = 16) compared with 2 weeks of preservation (n = 11; 431 ± 229 versus 438 ± 244 mm Hg). After 1 week, static and flow-preserved veins showed viability of the vessel segments with endothelium staining positive for CD31, von Willebrand factor, and endothelial nitric oxide synthase. Scanning electron microscopy demonstrated preservation of normal endothelial morphology and flow alignment in the flow-preserved samples compared with cobblestone endothelial appearance and some endothelial cell loss in the static samples. Static samples had significantly more platelet adhesion than flow-preserved samples did., Conclusions: Umbilical veins have adequate burst strength to function at neonatal systemic pressures. Preservation under flow conditions demonstrated normal endothelial and overall vascular morphology with less platelet adhesion compared with static samples. Preserved autologous umbilical veins are potential source for endothelialized shunts or cardiovascular repair tissue for neonates., (Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF