5 results on '"Redli PM"'
Search Results
2. Prevalence of Occult Hepatitis B Virus Infection in Blood Donors with Negative ID-NAT in Switzerland.
- Author
-
Zbinden A, Ries J, Redli PM, Shah C, Glauser A, Goslings D, Huzly D, Böni J, Gottschalk J, and Frey BM
- Abstract
Introduction: Screening of hepatitis B surface antigen (HBsAg) and individual-donation nucleic acid amplification testing (ID-NAT) of blood donors have become standard to detect hepatitis B virus (HBV) infection. However, there is still a residual risk of HBV transmission by blood components of donors suffering from occult HBV infection (OBI). Therefore, many countries implemented universal testing of anti-HBV core antigen (anti-HBc) antibodies in order to increase blood safety. In Switzerland, anti-HBc testing is not part of the routine blood donor-screening repertoire. Therefore, we sought to assess prevalence of donors with OBI in a Swiss blood donor collective., Methods: Blood donations were prospectively investigated for the presence of anti-HBc antibodies during two time periods (I: all donors, March 2017; II: first-time donors only, April 2017 until February 2018). Anti-HBc-positive findings were confirmed by an anti-HBc neutralization test. Discarded plasma samples of anti-HBc-confirmed positive donors were ultracentrifuged and subsequently retested by regular HBV-ID-NAT to search for traces of HBV., Results: During time period I, 78 (1.6%) individuals out of 4,923 donors were confirmed anti-HBc-positive. Sixty-nine (88%) anti-HBc-positive samples were available and processed by ultracentrifugation followed by repeat HBV-ID-NAT. Four samples (5.8%) were found positive for HBV DNA. Sixty-five (94.2%) samples remained HBV NAT-negative upon ultracentrifugation. During time period II, 56 (0.9%) donor samples out of 6,509 exhibited anti-HBc-confirmed positive. Fifty-five (98%) samples could be reassessed by HBV-ID-NAT upon ultracentrifugation. Three (5.5%) samples contained HBV DNA and 52 (94.5%) samples remained HBV NAT-negative., Conclusion: Overall, we detected 7 viremic OBI carriers among 11,432 blood donors, which tested negative for HBV by standard HBV-ID-NAT and HBsAg screening. In contrast, OBI carriers showed positive anti-HBc findings which could be confirmed in 83.8% of the cases. Thus, OBI might be missed by the current HBV screening process of Swiss blood donors. We suggest to review current HBV screening algorithm. Extended donor screening by anti-HBc testing may unmask OBI carriers and contribute to blood safety for the recipient of blood products., Competing Interests: The authors have no conflicts of interest to declare., (Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel.)
- Published
- 2022
- Full Text
- View/download PDF
3. Usefulness of the GenMark ePlex RPP assay for the detection of respiratory viruses compared to the FTD21 multiplex RT-PCR.
- Author
-
Steiner F, Schmutz S, Gosert R, Huder JB, Redli PM, Capaul R, Hirsch HH, Böni J, and Zbinden A
- Subjects
- Diagnostic Tests, Routine, Humans, Respiratory Tract Infections virology, Sensitivity and Specificity, Time Factors, Viruses classification, Viruses genetics, Molecular Diagnostic Techniques, Multiplex Polymerase Chain Reaction, Respiratory Tract Infections diagnosis, Viruses isolation & purification
- Abstract
Cartridge-based multiplex panels covering numerous pathogens offer an advantage of minimal hands-on-time and short time to result to commercial RT-PCR assays. In this study, we evaluated the performance of the ePlex respiratory pathogen panel (RPP) compared to the Fast Track Diagnostics Respiratory pathogens 21 multiplex RT-PCR assay (FTD21) using 400 clinical respiratory samples. Discrepant results were further analysed by a reference nucleic acid amplification testing (NAT) and a composite reference approach was used for final interpretation. Discordant results were observed in 56 targets corresponding to 54 samples. Sensitivities and specificities were 85.5% and 99.9% for the ePlex RPP and 95.8% and 99.7% for the FTD21 system, respectively. Altogether, the ePlex RPP is a valuable tool for the rapid detection of a number of different respiratory viruses with the exception of the coronavirus family (low sensitivity ranging from 50-80%) and samples with a low pathogen load (Ct values >33)., Competing Interests: Disclosures The authors declare no conflict of interest., (Copyright © 2021 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
4. Evaluation of the RIDA®GENE RT-PCR assays for detection of sapovirus, astrovirus, adenovirus, and rotavirus in stool samples of adults in Switzerland.
- Author
-
Redli PM, Wanzenried A, Huder JB, Berger C, Berlinger L, Capaul R, Böni J, and Zbinden A
- Subjects
- Adenoviridae classification, Adenoviridae isolation & purification, Adult, Female, Humans, Male, Mamastrovirus classification, Mamastrovirus isolation & purification, Real-Time Polymerase Chain Reaction standards, Reproducibility of Results, Rotavirus classification, Rotavirus isolation & purification, Sapovirus classification, Sapovirus isolation & purification, Sensitivity and Specificity, Switzerland, Adenoviridae genetics, Feces virology, Gastroenteritis diagnosis, Gastroenteritis virology, Mamastrovirus genetics, Real-Time Polymerase Chain Reaction methods, Rotavirus genetics, Sapovirus genetics
- Abstract
Sapovirus (SaV) and astrovirus (AstV) increasingly are recognized as cause of acute viral gastroenteritis (AGE). We evaluated the real-time RT-PCR assays RIDA®GENE SaV and viral stool panel II (RGN RT-PCR) for detection of SaV, AstV, adenovirus (AdV) F40/41 and rotavirus (RoV) in clinical stool samples (n = 69). Results were compared with reference singleplex RT-PCRs. The sensitivity for SaV, AstV and RoV are 100%, the specificity ranges from 98.1% to 100%. In 10 out of 11 AdV (all types) samples, the RGN RT-PCR for AdV F40/41 displayed negative results. Retrospectively, 196 stool specimens from adult patients previously tested negative for norovirus (NoV) were analyzed. In about 10% of NoV-negative stool samples, AdV (n = 9), RoV (n = 6), AstV (n = 3) or SaV (n = 3) were found. The RGN RT-PCR assays are useful for detection of enteric viruses other than NoV. This study emphasizes the need for further testing of NoV-negative stool samples in patients with AGE., (Copyright © 2019 Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
5. The Ska complex promotes Aurora B activity to ensure chromosome biorientation.
- Author
-
Redli PM, Gasic I, Meraldi P, Nigg EA, and Santamaria A
- Subjects
- Biocatalysis, Centromere metabolism, Chromosome Positioning, Chromosome Segregation, HeLa Cells, Humans, Kinetochores metabolism, Microtubules metabolism, Phosphorylation, Protein Phosphatase 1 metabolism, Aurora Kinase B metabolism, Chromosomal Proteins, Non-Histone metabolism, Multiprotein Complexes metabolism
- Abstract
Chromosome biorientation and accurate segregation rely on the plasticity of kinetochore-microtubule (KT-MT) attachments. Aurora B facilitates KT-MT dynamics by phosphorylating kinetochore proteins that are critical for KT-MT interactions. Among the substrates whose microtubule and kinetochore binding is curtailed by Aurora B is the spindle and kinetochore-associated (Ska) complex, a key factor for KT-MT stability. Here, we show that Ska is not only a substrate of Aurora B, but is also required for Aurora B activity. Ska-deficient cells fail to biorient and display chromosome segregation errors underlying suppressed KT-MT turnover. These defects coincide with KNL1-Mis12-Ndc80 network hypophosphorylation, reduced mitotic centromere-associated kinesin localization, and Aurora B T-loop phosphorylation at kinetochores. We further show that Ska requires its microtubule-binding capability to promote Aurora B activity in cells and stimulates Aurora B catalytic activity in vitro. Finally, we show that protein phosphatase 1 counteracts Aurora B activity to enable Ska kinetochore accumulation once biorientation is achieved. We propose that Ska promotes Aurora B activity to limit its own microtubule and kinetochore association and to ensure that KT-MT dynamics and stability fall within an optimal balance for biorientation., (© 2016 Redli et al.)
- Published
- 2016
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.