Marco Solinas, Alfonso Sciangula, Mattia Glauber, Attilio Renzulli, Orlando Parise, Roberto Di Bartolomeo, Michele De Bonis, Ezio Micalizzi, Ottavio Alfieri, Davide Pacini, Andrea Montisci, Philippe Primo Caimmi, Antonio Miceli, Filiberto Serraino, R. Liberi, Francesca Faragalli, Chiara Comoglio, Michele Celiento, Enrico Vizzardi, Gloria Demicheli, Roberto Lorusso, Alessandro Mazzola, Antonio Lio, Domenico Mercogliano, Uberto Bortolotti, Maurizio Taramasso, Sandro Gelsomino, Gian Luca Martinelli, RS: Carim - V04 Surgical intervention, CTC, MUMC+: MA Med Staf Spec CTC (9), Lorusso, Roberto, Miceli, Antonio, Gelsomino, Sandro, Lio, Antonio, Parise, Orlando, Montisci, Andrea, Vizzardi, Enrico, Pacini, Davide, Di Bartolomeo, Roberto, Renzulli, Attilio, Serraino, Filiberto G, Comoglio, Chiara, Liberi, Roberta, Martinelli, Gianluca, Sciangula, Alfonso, Mazzola, Alessandro, Faragalli, Francesca, De Bonis, Michele, Taramasso, Maurizio, Alfieri, Ottavio, Caimmi, Philippe, Micalizzi, Ezio, Mercogliano, Domenico, Demicheli, Gloria, Celiento, Michele, Bortolotti, Uberto, Solinas, Marco, Glauber, Mattia, and Martinelli, GianLuca
Background. Postoperative outcomes of a third-generation porcine bioprosthesis for mitral valve replacement (MVR) have been poorly addressed. The objective of this study was to perform an independent, retrospective, multicenter study on outcomes of patients undergoing MVR with a Mosaic (Medtronic Inc, Minneapolis, MN) porcine bioprosthesis.Methods. From 1998 to 2011, 805 patients underwent MVR with a Mosaic porcine valve in 11 cardiac centers. There were 465 female patients (58%), and the overall mean age was 73.5 +/- 7 years. Associated procedures included coronary artery bypass grafting (201 patients; 24.9%), aortic valve replacement (152 patients; 18.9%), tricuspid annuloplasty (187 patients; 22.3%), and other cardiac procedures (116 patients; 14.4%).Results. Median follow-up was 44 months (interquartile range, 16 to 63), with a cumulative duration of 2.769 patientyears. Early mortality for isolated elective MVR was 3.8% (12 of 313), and overall early mortality was 7.8% (n = 63). The rate of late mortality was 3.4%/patient-year (95 late deaths). At 10 years, overall survival was 57.4% (95% confidence interval [CI], 48.8% to 67.5%), and cumulative rates of cardiac- and valve-related death were 7.4% (95% CI, 4.8% to 10.1%) and 1.1% (95% CI, 0.2% to 1.9%), respectively. The 10-year cumulative rates of thromboembolic and hemorrhagic events were 6.6% (95% CI, 1.4% to 11.8%) and 3.9% (95% CI, 0.1% to 8%), respectively, and the 10-year cumulative incidence of prosthetic valve endocarditis was 3%(95% CI, 1.2% to 4.9%). Finally, the 10-year cumulative incidences of structuralvalve degeneration andreoperationswere5.8%(95% CI, 0.2% to 11.5%) and 4.8% (95% CI, 0.7% to 10.3%), respectively.Conclusions. This independent, multicenter, retrospective study indicated that the Mosaic porcine bioprosthesis forMVR provides satisfactory results in terms of both early andlong-termoutcomes upto 14 years fromits implantation. (C) 2020 by The Society of Thoracic Surgeons