90 results on '"Pejić, Dragan"'
Search Results
2. Batteryless IoT module for sensing and signaling failures of passive power accessories
- Author
-
Antić, Boris, Bulat, Marina, Pejić, Dragan, Gotovac, Zdravko, and Mitrović, Zoran
- Published
- 2023
- Full Text
- View/download PDF
3. The impact of the conversion starting threshold on the estimation of the RMS value
- Author
-
Subotin, Marina, Mirković, Stefan, Gazivoda, Nemanja, Pejić, Dragan, Urekar, Marjan, and Antić, Boris
- Published
- 2022
- Full Text
- View/download PDF
4. Application of two-bit dithered Discrete Fourier basis functions in electricity measurement
- Author
-
Đorđević-Kozarov Jelena, Juhas Atila, Pejić Dragan, Sovilj Platon, and Vujičić Vladimir
- Subjects
fourier transformation ,basis functions ,dither ,stochastic digital measurement method ,Agriculture - Abstract
The paper defines an algorithm for generating two-bit dithered discrete Fourier basis functions (DDFBF) used in a Stochastic Digital Discrete Fourier Transformation (SDDFT) processor. Based on the theoretical criterion of upper limit precision of norm and orthogonality, the orthonormality of DFT with 32 harmonics is explored by simulation and experimentally. The experiment was detailed and comprehensive, both for norm and for both types of orthogonality. It is performed in 236,8 million points in each of three variants of orthonormality. The matching of theoretical and experimental precision is very acceptable and it can be said with great confidence that the proposed algorithm for generating DDFBF is correct. The DDFBF approach plays a key role in electricity measurement, which is emphasized in the paper.
- Published
- 2021
- Full Text
- View/download PDF
5. Preliminary design of an analog discrete uniform noise generator
- Author
-
Vujičić Bojan, Pejić Dragan, Radonjić Aleksandar, and Vujičić Vladimir
- Subjects
analog discrete uniform noise generator ,two-bit sdmm ,multi-bit sdmm ,d/a conversion ,Agriculture - Abstract
The paper presents the basic idea of the construction and a practical realization of a novel analog discrete uniform noise generator. The source of noise is a carbon resistor, the noise signal is linearly amplified and its value is limited in the finite small range [xg, xg]. The probability density function (PDF) of the carbon resistor thermal noise in that region is square one. By narrowing the symmetric allowable gap (interval) around zero, PDF of the noise approaches a uniform distribution. The factor of deviation from the uniform distribution is precisely defined and its value is practically negligible. In addition, the paper discusses the application of the proposed dither noise, both in the two-bit and in the multi-bit stochastic digital measurement method (SDMM). It is shown that noise is more suitable for application in multi-bit SDMM, because it is less sensitive to deviations from the uniform distribution.
- Published
- 2021
- Full Text
- View/download PDF
6. The application of IoT solutions in greenhouses with the aim of reducing electrical energy consumption
- Author
-
Šaš Milan and Pejić Dragan
- Subjects
prototype ,greenhouse ,control ,application ,python ,Agriculture - Abstract
In this paper, we will show a prototype of a system designed based on Internet of Things solutions with the aim of optimizing electrical energy consumption in order to achieve desired conditions for the growth and development of plants located in the greenhouse. The physical parameters that this system monitors are temperature, relative humidity, soil humidity and luminescence levels. In this prototype, we have three measurement nodes with the task of collecting parameter data, processing them and sending resulting data, via wireless communication, to a receiver. The receiver forwards data to the application on PC. The application processes the data and displays it to the end user who can choose to automatically or manually control the devices that are inside of the greenhouse. Systems placed inside the greenhouse are heating, irrigation, lighting and ventilation systems.
- Published
- 2021
- Full Text
- View/download PDF
7. Stochastic measurement of wind power using a two-bit A/D converter
- Author
-
Vujicic, Vladimir, Licina, Boris, Pejic, Dragan, Sovilj, Platon, and Radonjic, Aleksandar
- Published
- 2020
- Full Text
- View/download PDF
8. Improvement of an existing method of asynchronous sampling for determining RMS value
- Author
-
Mirković Stefan, Pejić Dragan, Urekar Marjan, Vujičić Bojan, and Novaković Đorđe
- Subjects
Root mean square ,Average ,Asynchronous sampling ,Measurements ,Metrology ,Electrical engineering. Electronics. Nuclear engineering ,TK1-9971 - Abstract
Measuring a value by definition seems to be the best solution for getting the most precise results. In this paper, it is shown that by changing the general definition of root mean square (RMS) and average value of a periodic signal, their measurement can be improved. When measuring RMS with asynchronous sampling, it was observed that results were scattered around two values, and it was found that the main cause for this was initial sampling time. Redefining the RMS value has been proposed in order to increase the efficiency of the asynchronous method. After comparing the results based on general and proposed definition for RMS value, it was observed that there was significantly less scattering of results and higher accuracy. The simulation proved that the application of the proposed definition of RMS gives more accurate and precise results than the general definition for analog to digital (AD) converters with both lower and higher resolution.
- Published
- 2018
- Full Text
- View/download PDF
9. Measurement of definite integral of sinusoidal signal absolute value third power using digital stochastic method
- Author
-
Beljić Željko, Ličina Boris, Sovilj Platon, Pejić Dragan, Vujičić Vladimir, and Vujičić Bojan
- Subjects
AD conversion ,digital measurements ,electrical measurements ,probability ,stochastic processes ,Electrical engineering. Electronics. Nuclear engineering ,TK1-9971 - Abstract
In this paper a special case of digital stochastic measurement of the third power of definite integral of sinusoidal signal’s absolute value, using 2-bit AD converters is presented. This case of digital stochastic method had emerged from the need to measure power and energy of the wind. Power and energy are proportional to the third power of wind speed. Anemometer output signal is sinusoidal. Therefore an integral of the third power of sinusoidal signal is zero. Two approaches are proposed for the third power calculation of the wind speed signal. One approach is to use absolute value of sinusoidal signal (before AD conversion) for which there is no need of multiplier hardware change. The second approach requires small multiplier hardware change, but input signal remains unchanged. For the second approach proposed minimal hardware change was made to calculate absolute value of the result after AD conversion. Simulations have confirmed theoretical analysis. Expected precision of wind energy measurement of proposed device is better than 0,00051% of full scale. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR32019]
- Published
- 2017
- Full Text
- View/download PDF
10. Phase measurement methods based on timer modules
- Author
-
Mandić, Sanja, primary, Pejić, Dragan, additional, Novaković, Đorđe, additional, Urekar, Marjan, additional, and Sovilj, Platon, additional
- Published
- 2023
- Full Text
- View/download PDF
11. Digital Stochastic Measurement and Industry 4.0
- Author
-
Sovilj, Platon, primary, Pejić, Dragan, additional, Urekar, Marjan, additional, and Mandić, Sanja, additional
- Published
- 2023
- Full Text
- View/download PDF
12. Metrology and Capacity Building in Higher Education: Project Knowledge triangle for a low carbon economy (KALCEA)
- Author
-
Sovilj, Platon, primary, Mandić, Sanja, additional, Pejić, Dragan, additional, Novaković, Đorđe, additional, and Urekar, Marjan, additional
- Published
- 2023
- Full Text
- View/download PDF
13. Composite resistor standard for calibration of measuring transducers in laboratory conditions
- Author
-
Urekar Marjan, Bulat Marina, Vujičić Bojan, and Pejić Dragan
- Subjects
calibration ,temperature coefficient ,limit of error ,transducer ,metrology ,instrumentation ,composite resistor standard ,Electrical engineering. Electronics. Nuclear engineering ,TK1-9971 - Abstract
Calibration of measuring transducers for precision measurement is done by measuring voltage drop at the resistor standard, produced by output dc current proportional to the input measured value. Resistance fluctuations due to the temperature coefficient of the resistor standard are minor, thanks to the stable temperature conditions in laboratory environment. This fact brings the need to calculate the effect of resistor self-heating on its resistance. This thermal effect, produced by the flow of current through the resistor, is often disregarded. For the precise measurements this can be a significant source of error and must be quantified. This paper describes mathematical model of measurement error, resistor self-heating coefficient is defined, as it’s not usually given in product datasheets. The effect on measurement results is given in detail. Composite resistor standard prototype is described, made from off-the-shelf mass produced components, calculated and hand selected to cancel the self-heating coefficient effects. The prototype is compared to the existing commercially available high performance resistor standard.
- Published
- 2016
- Full Text
- View/download PDF
14. The establishment of operational amplifiers output steady state voltage
- Author
-
Radetić Radojle M., Mitrović Zoran Lj., and Pejić Dragan V.
- Subjects
operational amplifiers ,settling time ,slew rate ,Engineering (General). Civil engineering (General) ,TA1-2040 - Abstract
Operational amplifiers (OA) present indispensable elements in analog signal processing. In practice it is often important to determine how much time an OP's output voltage takes to get close to a steady state within predetermined boundaries. The existing literature just touches this question and generally gives undefined, incomplete and somewhere inaccurate answers. In this paper, results of detailed theoretical investigation of a transition process in the OP after an input voltage Heaviside step change are given.
- Published
- 2015
- Full Text
- View/download PDF
15. Optimalna rezolucija stohastičkih embedid sistema
- Author
-
Pejić, Dragan, Pejić, Dragan, Radonjić, Aleksandar, Vujičić, Vladimir, Pejić, Dragan, Pejić, Dragan, Radonjić, Aleksandar, and Vujičić, Vladimir
- Abstract
U radu se elabolira primena stohastičke digitalne merne metode (SDMM) u embedid sistemima. U literaturi je dokazano da je optimalna rezolucija SDMM trobitna i da je optimalni brojni sistem za primenu u obradi takođe trobitni. Ove činjenice su motivisale autore da analiziraju optimalne rezolucije stohastičke A/D konverzije, stohastičke obrade i stohastičke D/A konverzije.
- Published
- 2021
16. Kongres metrologa 2022 - Naučni odbor
- Author
-
Ogrizović, Vukan, Mišković, Zoran, Sovilj, Platon, Damjanović, Srđan, Naumović-Vuković, Dragana, Gabrić, Ognjen, Pejić, Dragan, Urekar, Marjan, Ogrizović, Vukan, Mišković, Zoran, Sovilj, Platon, Damjanović, Srđan, Naumović-Vuković, Dragana, Gabrić, Ognjen, Pejić, Dragan, and Urekar, Marjan
- Abstract
Društvo metrologa je formirano u cilju objedinjavanja aktivnosti svih metrologa, pružanju pomoći prilikom njihovog rada i međusobne razmene iskustava. Misija Društva metrologa je da okuplja i podstiče stručnjake koji se bave metrologijom, ili srodnim disciplinama, da međusobno razvijaju kreativnu inicijativu za njen dalji razvoj i unapređenje, prati razvoj metrologije i ukazuje na tokove, zbivanja i promene u ovoj oblasti i da se povezuje sa sličnim naučnim, stručnim i drugim organizacijama, domaćim ili međunarodnim, radi promocije metrologije. Osnovni ciljevi Društva: Okupljanje stručnjaka iz oblasti metrologije Praćenje razvoja metrologije Priprema standarda od značaja za struku Sarađivanje kod izrade propisa iz oblasti metrologije Izdavanje publikacija i časopisa iz oblasti metrologije Organizovanje simpozijuma o mernoj opremi
- Published
- 2022
17. Geothermal heat exchanger with coaxial flow of fluids
- Author
-
Pejić Dragan M., Stojiljković Dragan T., Stojiljković Staniša T., Đurović-Petrović Maja, and Mitić Nebojša
- Subjects
geothermal energy ,heat exchanger ,coaxial flow ,Chemical technology ,TP1-1185 - Abstract
The paper deals with a heat exchanger with coaxial flow. Two coaxial pipes of the secondary part were placed directly into a geothermal boring in such a way that geothermal water flows around the outer pipe. Starting from the energy balance of the exchanger formed in this way and the assumption of a study-state operating regime, a mathematical model was formulated. On the basis of the model, the secondary circle output temperature was determined as a function of the exchanger geometry, the coefficient of heat passing through the heat exchange areas, the average mass isobaric specific heats of fluid and mass flows. The input temperature of the exchanger secondary circle and the temperature of the geothermal water at the exit of the boring were taken as known values. Also, an analysis of changes in certain factors influencing the secondary water temperature was carried out. The parameters (flow temperature) of the deep boring B-4 in Sijarinska Spa, Serbia were used. The theoretical results obtained indicate the great potential of this boring and the possible application of such an exchanger.
- Published
- 2005
- Full Text
- View/download PDF
18. Idejni projekat generatora analognog diskretnog uniformnog šuma
- Author
-
Vujičić, Bojan, Radonjić, Aleksandar, Pejić, Dragan, and Vujičić, Vladimir
- Subjects
noise generators ,random number generator ,stochastic digital measurement method ,D/A conversion - Abstract
U radu ce predlaže ideja generatora analognog diskretnog uniformnog šuma (GADUŠ) za primenu u stohastičkoj digitalnoj mernoj metodi. Predloženim rešenjem, za razliku od standardnog, koje koristi generator slučajnih brojeva i precizni i tačni digitalno-analogni konvertor (DAK), se prevazilazi problem ograničene rezolucije DAK-a i njegov uzak propusni opseg. The paper proposes the idea of an analog discrete uniform noise generator for application in the stochastic digital measurement method. The proposed solution, unlike the standard one, which uses a random number generator and a precise and accurate digital-to-analog converter (DAK), overcomes the problem of limited DAK resolution and its narrow bandwidth.
- Published
- 2021
19. Stochastic digital DFT processor and its application to measurement of reactive power and energy
- Author
-
Pejić, Dragan, Pejić, Dragan, Naumović Vuković, Dragana, Vujičić, Bojan, Radonjić, Aleksandar, Sovilj, Platon, Vujičić, Vladimir, Pejić, Dragan, Pejić, Dragan, Naumović Vuković, Dragana, Vujičić, Bojan, Radonjić, Aleksandar, Sovilj, Platon, and Vujičić, Vladimir
- Abstract
In this paper we present the model of digital stochastic DFT processor. Compared to the classical DFT/FFT processors, the proposed model has two advantages: first, it is much simpler and cheaper to implement, and second, it allows us to compute individual DFT components either in isolation or in parallel. In order to prove the validity of our model, we have simulated the measurement of reactive power and energy. In addition, we have conducted several experiments under field and laboratory conditions. The obtained results have shown that reactive power and energy can be measured with an accuracy of several ppm. © 2018 Elsevier Ltd
- Published
- 2018
20. Stochastic two-bit on-line temperature measurement with RTD Pt-100 sensor operating in a nonlinear mode
- Author
-
Sovilj, Platon, Vujičić, Bojan, Pejić, Dragan, Radonjić, Aleksandar, and Vujičić, Vladimir
- Subjects
Pt-100 sensors ,two-bit stochastic digital measurement ,calibration ,temperature measurement - Abstract
The paper proposes a method and device for on-line temperature measurement with Pt-100 sensor operating in a nonlinear mode. The sensor measures the temperature in range of 00C to 2000C, whereas the measured data are processed by applying a two-bit stochastic digital measurement method. The proposal is theoretically analyzed and tested experimentally. It is shown that the accuracy of the method depends on the accuracy of the sensor. At a sampling frequency of 1 MHz, the maximum accuracy is reached in 17.5 sec. and is equal to 0.015% of full scale (FS). On the other hand, when the measurement time interval is 0.1 sec. (the shortest measurement interval), the accuracy is equal to 0.1% of FS. Therefore, the proposed device can be used for both calibration and measurement purposes.
- Published
- 2020
21. Metoda merenja snage i energije vetra zasnovana na merenju na intervalu
- Author
-
Sovilj, Platon, Pejić, Dragan, Pilipović, Stevan, Kovačević, Dragan, Mitrović, Zoran, Urekar, Marjan, Ličina, Boris, Sovilj, Platon, Pejić, Dragan, Pilipović, Stevan, Kovačević, Dragan, Mitrović, Zoran, Urekar, Marjan, and Ličina, Boris
- Abstract
U disertaciji je prikazan i predložen novi metod merenja snage i energije vetra koji se bazira na stohastičkoj digitalnoj mernoj metodi (SDMM), umesto do sada korišćene standardne sempling metode (SSM). Standard za merenje brzine vetra predstavlja anemometar sa šoljicama, koji na svom izlazu daje sinusni napon čija su amplituda i frekvencija linearno zavisne od brzine vetra. Kako su snaga i energija vetra proporcionalne trećem stepenu brzine vetra, u tu svrhu se primenjuje generalizovan hardver namenjen za računanje proizvoda tri ulazna signala. Zbog niskog frekvencijskog opsega ulaznog signala izvršeno je značajno pojednostavljenje hardvera mernog uređaja. Teorijskom analizom, simulacijom, a potom i eksperimentom potvrđena je hipoteza istraživanja, da se SDMM uspešno može koristiti za merenje snage i energije vetra., In this dissertation а new wind power and energy measurement method, based on Stochastic Digital Measurement Method (SDMM), was elaborated and proposed, to replace the commonly used Standard Sampling Method (SSM). The standard for wind speed measurement is a cup anemometer that provides a sinusoidal voltage on its output, having the amplitude and frequency linearly dependent of the wind speed. Since the wind power and energy are proportional to the third degree of the wind speed, the general case hardware has been designed for the product calculation over three input signals. The low frequency range of the input signal allows for a significant simplification of the measuring instrument hardware. By theoretical analysis and simulation, and consequently through an experiment the hypothesis of this research was confirmed - that SDMM can be successfully used to measure wind power and energy.
- Published
- 2020
22. Нова метода за повећање ефективне резолуције стохастичких мерних инструмената високих перформанси
- Author
-
Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, Urekar, Marjan, Gazivoda, Nemanja, Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, Urekar, Marjan, and Gazivoda, Nemanja
- Abstract
Дисертација истражује утицај примене дитерског сигнала (дискретног аналогног униформног шума) генерисаног новом методом на повећање ефективне резолуције мерних инструмената базираних на стохастичкој дигиталној мерној методи. У дисертацији је дат преглед досадашњих решења базираних на стохастичкој дигиталној мерној методи у циљу сагледавања потребе и оправданости истраживања. Предложено решење представља комбинацију псеудослучајног и истински случајног генератора и као такво задржава најбоље особине из обе области. Дaт je прeдлoг нoве методе гeнeрисaњa шумa унифoрмнe рaспoдeлe aмплитудa. Умeстo уoбичajeнoг нaчинa гeнeрисaњa кoришћeњeм гeнeрaтoрa псeудoслучajних брojeвa и Д/А кoнвeртoрa, oвдe сe прeдлaжe гeнeрисaњe зaснoвaнo нa нeунифoрмнoм одабирању тeстeрaстoг или троугаоног нaпoнa. Oсим уштeдe збoг нeкoришћeњa Д/А кoнвeртoрa, дoбит je и мoгућнoст гeнeрисaњa нaпoнa из кoнтинуалнoг, умeстo дискрeтнoг скупa aмплитудa. Вeћинa дaнaшњих хaрдвeрских гeнeрaтoрa псeудoслучajнoг нaпoнa, сe бaзирa нa употреби микрoкoнтрoлeра и Д/A кoнвeртoра, пa je нa тaj нaчин рeзoлуциja гeнeрисaњa псeудoслучajнoг нaпoнa oгрaничeнa резолуцијом Д/A кoнвeрторa. Одабирањем тестерастог или троугаоног напона предложеном методом се остварује готово неограничена резолуција. Употреба овако генерисаног дитерског сигнала доводи до повећања ефективне резолуције код стохастичких мерних инстурмената. Симулацијом је одређена оптимална структура генератора на основу предложене методе. Експериментална мерења су изведена помоћу развијеног прототипа хардверског генератора., Disertacija istražuje uticaj primene diterskog signala (diskretnog analognog uniformnog šuma) generisanog novom metodom na povećanje efektivne rezolucije mernih instrumenata baziranih na stohastičkoj digitalnoj mernoj metodi. U disertaciji je dat pregled dosadašnjih rešenja baziranih na stohastičkoj digitalnoj mernoj metodi u cilju sagledavanja potrebe i opravdanosti istraživanja. Predloženo rešenje predstavlja kombinaciju pseudoslučajnog i istinski slučajnog generatora i kao takvo zadržava najbolje osobine iz obe oblasti. Dat je predlog nove metode generisanja šuma uniformne raspodele amplituda. Umesto uobičajenog načina generisanja korišćenjem generatora pseudoslučajnih brojeva i D/A konvertora, ovde se predlaže generisanje zasnovano na neuniformnom odabiranju testerastog ili trougaonog napona. Osim uštede zbog nekorišćenja D/A konvertora, dobit je i mogućnost generisanja napona iz kontinualnog, umesto diskretnog skupa amplituda. Većina današnjih hardverskih generatora pseudoslučajnog napona, se bazira na upotrebi mikrokontrolera i D/A konvertora, pa je na taj način rezolucija generisanja pseudoslučajnog napona ograničena rezolucijom D/A konvertora. Odabiranjem testerastog ili trougaonog napona predloženom metodom se ostvaruje gotovo neograničena rezolucija. Upotreba ovako generisanog diterskog signala dovodi do povećanja efektivne rezolucije kod stohastičkih mernih insturmenata. Simulacijom je određena optimalna struktura generatora na osnovu predložene metode. Eksperimentalna merenja su izvedena pomoću razvijenog prototipa hardverskog generatora., The dissertation investigates the impact of the application of the dithering signal (discrete analogue uniform noise) generated by the new method for increasing the effective resolution of measurement instruments based on the stochastic digital measurement method. The dissertation provides an overview of the existing solutions based on the stochastic digital measurement method in order to understand the need and justification of the research. The proposed solution represents a combination of a pseudorandom and truly random generator and as such holds the best features in both areas. А suggestion of a new way of generating the noise of the uniform distribution of amplitudes is presented. Instead of the usual way of generating using a pseudorandom number generator and a D/A converter, the generation based on the nonuniform sampling of sawtooth or triangle voltage is proposed. In addition to the savings due to the non-use of a D/A converter, the possibility of generating voltages from a continual instead of a discrete amplitude set is also obtained. Most of today's hardware pseudorandom voltage generators are based on the use of a microcontroller and D/A converter, so in this way the resolution of the pseudorandom voltage generation is limited by the resolution of the D/A converter. By sampling the sawtooth or triangle voltage using the proposed method, almost unlimited resolution is achieved. The use of this generated dither signal leads to an increase in effective resolution in stochastic measuring instruments. The simulation determined the optimal structure of the generator based on the proposed method. Experimental measurements were made using developed hardware.
- Published
- 2019
23. Stochastic embedded systems
- Author
-
Vujičić, Vladimir, Radonjić, Aleksandar, and Pejić, Dragan
- Subjects
stochasticity ,embedded systems - Abstract
Computing, analog-to-digital conversion and digital-to-analog conversion are the three most important functions in embedded systems. The last two may include stochasticity regardless of whether the computing is stochastic or not. The purpose of this paper is to specify and clarify the role of stochasticity in embedded systems.
- Published
- 2018
24. SIMULACIONI MODEL METODE ZA GENERISANJE ŠUMA DISKRETNOG U VREMENU I KONTINUALNOG PO VREDNOSTI
- Author
-
Knežević, Marko, primary and Pejić, Dragan, primary
- Published
- 2019
- Full Text
- View/download PDF
25. Мерење стабилности фреквенције у фреквенцијском домену
- Author
-
Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, Antić, Boris, Milanović, Ivica, Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, Antić, Boris, and Milanović, Ivica
- Abstract
Дисертација истражује најприхватљивије методе мерења стабилности фреквенције у фреквенцијском домену, односно мерење вредности величине „фазни шум“, приликом процеса еталонирања мерне опреме. Када се говори о мерној опреми која је предмет еталонирања, дисертација је, пре свега, окренута ка еталонирању врхунских комерцијалних стандарда (еталона) фреквенције. Приказана истраживања су била основ за покретање и реализацију истраживачко-развојног пројекта у оквиру Министарства одбране, који је имао за циљ оспособљавање метролошке лабораторије Техничког опитног центра Војске Србије за потпуно еталонирање мерне опреме из области времена и фреквенције. Различите методе мерења подразумевају и различите мерне могућности, као и врло широк спектар еталонске и мерне опреме која се користи при њиховој реализацији. У дисертацији се приказују различити начини мерења фазног шума и описују методе реализоване на основу доступне мерне опреме. Како се ради о методама упоредне анализе референтног и мереног сигнала, посебно критична позиција је одабир референце, односно референтног еталона. Истраживање је довело до закључака којима је предложен метод мерења потребне и довољне мерне несигурности као и начин реализације изабране методе, односно одабир еталонске мерне опреме. У циљу увођења мерне методе у употребу, извршена су и приказана мерења на различитим типовима и врстама мерне опреме. Валидација методе је остварена билатералним поређењем са Дирекцијом за мере и драгоцене метале, Група за време, фреквенцију и дистрибуцију времена. Да је могуће реализовати методу мерења фазног шума приликом еталонирања најквалитетнијих осцилатора је постављена хипотеза дисертације, која је истраживањем доказана и практично спроведена. Крајњи резултат истраживања је довео до увођења признате методе еталонирања фазног шума, први пут, Disertacija istražuje najprihvatljivije metode merenja stabilnosti frekvencije u frekvencijskom domenu, odnosno merenje vrednosti veličine „fazni šum“, prilikom procesa etaloniranja merne opreme. Kada se govori o mernoj opremi koja je predmet etaloniranja, disertacija je, pre svega, okrenuta ka etaloniranju vrhunskih komercijalnih standarda (etalona) frekvencije. Prikazana istraživanja su bila osnov za pokretanje i realizaciju istraživačko-razvojnog projekta u okviru Ministarstva odbrane, koji je imao za cilj osposobljavanje metrološke laboratorije Tehničkog opitnog centra Vojske Srbije za potpuno etaloniranje merne opreme iz oblasti vremena i frekvencije. Različite metode merenja podrazumevaju i različite merne mogućnosti, kao i vrlo širok spektar etalonske i merne opreme koja se koristi pri njihovoj realizaciji. U disertaciji se prikazuju različiti načini merenja faznog šuma i opisuju metode realizovane na osnovu dostupne merne opreme. Kako se radi o metodama uporedne analize referentnog i merenog signala, posebno kritična pozicija je odabir reference, odnosno referentnog etalona. Istraživanje je dovelo do zaključaka kojima je predložen metod merenja potrebne i dovoljne merne nesigurnosti kao i način realizacije izabrane metode, odnosno odabir etalonske merne opreme. U cilju uvođenja merne metode u upotrebu, izvršena su i prikazana merenja na različitim tipovima i vrstama merne opreme. Validacija metode je ostvarena bilateralnim poređenjem sa Direkcijom za mere i dragocene metale, Grupa za vreme, frekvenciju i distribuciju vremena. Da je moguće realizovati metodu merenja faznog šuma prilikom etaloniranja najkvalitetnijih oscilatora je postavljena hipoteza disertacije, koja je istraživanjem dokazana i praktično sprovedena. Krajnji rezultat istraživanja je doveo do uvođenja priznate metode etaloniranja faznog šuma, prvi put, The dissertation examines the most acceptable methods for measuring the frequency stability in the frequency domain, that is, measuring the value of the "phase noise", during the process of measuring equipment calibration. When it comes to measuring equipment as a subject of calibration, the dissertation is, first of all, oriented towards the calibration of the highest commercial frequency standards. The presented researches were the basis for initiation and realization of the research and development project within the Ministry of Defense, which was aimed at training the metrology laboratory of the Technical Test Center of the Serbian Army for complete calibration of measuring equipment in the area of time and frequency. Different measurement methods also involve different measurement possibilities, as well as a very wide range of calibration and measuring equipment used in their realization. Different methods of measuring phase noise are described in the dissertation and they describe realized methods based on available measuring equipment. As for methods of comparative analysis of the reference and measured signal, a particularly critical position is the selection of the reference, that is, the reference oscillator. The research led to conclusions suggesting the method of measuring the necessary and sufficient measurement uncertainty, as well as the method of realization of the chosen method, i.e. selection of the standard measuring equipment. In order to put the measurement method into practice, measurements were performed on different types of measuring equipment. Validation of the method was achieved by bilateral comparison with the Directorate of Measures and Precious Metals, Group for time, frequency and time dissemination. The possibility to realize the method of phase noise measurement during the calibration of the highest quality oscillators is a hypothesis of the dissertation that has been set up, and has been proven and practically carried out by the re
- Published
- 2018
26. Prilog optimizaciji performansi digitalnih merenja
- Author
-
Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, Jeličić, Zoran, Urekar, Marjan, Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, Jeličić, Zoran, and Urekar, Marjan
- Abstract
U tezi se razmatra kriterijum optimalnosti stohastičkog fleš A/D konvertora (SFADC) koji predstavlja osnovu stohastičke digitalne metode merenja (SDMM). Razvijen je matematički i simulacioni model višebitnog SFADC i određen optimum broja bita rezolucije. Napravljen je hardverski prototip 4-bitnog stohastičkog mernog instrumenta (SMI), koji je ispitan brojnim eksperimentima i upoređen sa teorijski određenim vrednostima performansi merenja. Hipoteza ove teze – da postoji optimalni broj bita rezolucije SMI pri kome se ostvaruje maksimalna dobit u preciznosti merenja po ceni dupliranja potrebnog hardvera – potpuno je potvrđena., The thesis considers the criterion of optimality of the stochastic flash A/D converter (SFADC), which is the basis of the stochastic digital measurement method (SDMM). The mathematical and simulation model of the multibit SFADC was developed and the optimal number of bits of resolution was determined. A hardware prototype of a 4-bit stochastic measuring instrument (SMI) was made, tested in numerous experiments and compared with theoretically determined measurement performance values. The hypothesis of this thesis - that there is an optimal number of SMI resolution bits in which the maximum benefit of the measurement precision is achieved at the price of duplication of the required hardware - is fully confirmed
- Published
- 2018
27. Метода мерења електроокулографског сигнала на интервалу са преклапањем временских прозора
- Author
-
Sovilj, Platon, Mitrović, Zoran, Radenković, Dragan, Lukač, Damir, Pejić, Dragan, Đorđević-Kozarov, Jelena, Sovilj, Platon, Mitrović, Zoran, Radenković, Dragan, Lukač, Damir, Pejić, Dragan, and Đorđević-Kozarov, Jelena
- Abstract
У тези је предложена метода мерења ЕОГ сигнала на интервалу са преклапањем временских прозора, која представља модификацију дигиталне стохастичке методе мерења (ДСММ). Хардвер којим се предложена метода може имплементирати заснован је на рачунарској платформи и микроконтролерској структури. Метода је испитана бројним симулацијама и експериментима. Хипотеза ове тезе – да модел мерења ЕОГ сигнала на интервалу са преклапањем временских прозора омогућава пројектовање ЕОГ мерног уређаја који је отпорнији на утицај шума него ЕОГ мерни уређаји засновани на класичном дигиталном мерењу – потпуно је потврђена., U tezi je predložena metoda merenja EOG signala na intervalu sa preklapanjem vremenskih prozora, koja predstavlja modifikaciju digitalne stohastičke metode merenja (DSMM). Hardver kojim se predložena metoda može implementirati zasnovan je na računarskoj platformi i mikrokontrolerskoj strukturi. Metoda je ispitana brojnim simulacijama i eksperimentima. Hipoteza ove teze – da model merenja EOG signala na intervalu sa preklapanjem vremenskih prozora omogućava projektovanje EOG mernog uređaja koji je otporniji na uticaj šuma nego EOG merni uređaji zasnovani na klasičnom digitalnom merenju – potpuno je potvrđena., EOG signal measurement method over an interval using overlapping time windows, which represents the modification of the digital stochastic measurement method (DSMM), has been proposed in this thesis. The hardware that can implement the proposed method is based on a computer platform and a microcontroller structure. The method has been tested with numerous simulations and experiments. Hypothesis of this thesis - the model of EOG signal measurement over an interval using overlapping time windows allows a design of EOG measuring device more resistant to the noise impact than the EOG measuring devices based on classical digital measurement - has been fully confirmed.
- Published
- 2018
28. Prilog savremenom etaloniranju strujnih mernih transformatora
- Author
-
Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, Antić, Boris, Naumović-Vuković, Dragana, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, Antić, Boris, and Naumović-Vuković, Dragana
- Abstract
U ovoj doktorskoj disertaciji prikazana je koncepcija, realizacija i potvrda nove metode jednovremenog etaloniranja strujnih mernih transformatora sa dve različite merne aparature. Pregledom stručne literature ne postoji podatak da je ova metoda ranije primenjivana. U disertaciji su prikazane različite merne metode za ispitivanje i etaloniranje mernih transformatora koje imaju primenu u savremenoj praksi i koje podrazumevaju i različite merne mogućnosti. Takođe je i ekperimentalno potvrđeno jednovremeno ispitivanje i etaloniranje strujnih mernih transformatora sa nekoliko mernih aparatura koje su zasnovane na različitim metodama. Sprovedna istraživanja i eksperimentalni rezultati pokazuju i potvrđuju niz prednosti ovakvog načina etaloniranja. Detaljna analiza komponenti merne nesigurnosti pokazala je da se primenom ove metode postiže poboljšanje merne nesigurnost etaloniranja za skoro red veličine u odnosu na klasično pojedinačno etaloniranje sa dve različite merne aparature. Analiza uticajnih veličina na mernu nesigurnost pokazuje da se po ovoj novoj metodi etaloniranja eliminiše niz komponenti od kojih su najznačajnije: uticaj nejednakosti referentnih struja i ispitnog opterećenja. Istraživanja su takođe pokazala da jednovremena metoda osim što doprinosi podizanju tačnosti etaloniranja strujnih transformatora, ima primenu i u etaloniranju mernih aparatura za ispitivanje tačnosti mernih transformatora i interkonparaciji strujnih etalon transformatora. Kroz konkretne primere realizovane u praksi, razmotreni su i prikazani načini etaloniranja mernih aparatura za ispitivanje tačnosti ovom novom metodom. Interkomparacijom dva merna sistema visoke klase tačnosti Nacionalnog merološkog instituta Kanade (National Research Council Canada), od kojih je jedna razvijena u Elektrotehničkom Institutu "Nikola Tesla", pokazana je i prednost primene jednovremene metode u oblasti primarne metrologije strujnih mernih transformatora., The dissertation presents the concept, its realisation and verification of the new method of simultaneous comparison of the current transformers by two different measuring apparatus. It is shown by searching the literature, that this method has not been used before. In this dissertation different measuring methods for testing and calibration of current transformers, with their different measuring capabilities are presented. Most of them have been used in recent practice. Furthermore, the experimental verification of new simultaneous calibration method is presented. For this reason some measuring apparatus based on different measuring methods were used. Conducted research and experimental results confirmed a number of advantages of this calibration method. Detailed analysis of the components of the uncertainty of measurements shown that using simultaneous method uncertainty of measurements have been improved comparing to method with two individual calibration by different apparatus. In that case some of the measuring uncertainty components can be neglected. The most significant is component caused by variation of referent current and component caused by variation of burden. The research has also showed that simultaneous method can be used for calibration of measuring apparatus for current transformer accuracy testing and their inter-comparisons. The ways of calibration of apparatus for current transformer accuracy testing are considered and presented, through concrete examples realized in practice. A high-accuracy comparison of two NRC (National Research Council Canada) calibration systems were carried out by new simultaneous method. One measuring system is developed at Electrical Engineering institute Nicola Tesla, Belgrade. Accordingly the advantage of simultaneous method applied at the primary metrology of current transformer is verified.
- Published
- 2018
29. INTEGRACIJA E-SISTEMA ZA PODRSKU NASTAVI I SKOLSKIM PROCESIMA U SREDNJIM SKOLAMA REPUBLIKE SRPSKE
- Author
-
Pejić, Dragan, primary and Novaković, Nikola, additional
- Published
- 2017
- Full Text
- View/download PDF
30. Izražavanje merne nesigurnosti kapacitivnih razdelnika napona sa koncentrisanim parametrima u oblasti visokih frekvencija
- Author
-
Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, Antić, Boris, Kovačević, Uroš, Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, Antić, Boris, and Kovačević, Uroš
- Abstract
Ova disertacija sadrži analizu mogućnosti merenja brzih impulsnih napona i izražavanja odgovarajuće merne nesigurnosti. Dokazano je da je moguće izvršiti numeričku simulaciju odziva mernog sistema na impuls brzine porasta reda veličine pikosekunde. Izražena je merna nesigurnost kapacitivnog razdelnika napona Monte Karlo metodom. Prikazan je način konstruisanja kapacitivnog razdelnika napona sa talasovodnim prilagodnim otporom. Konstruisano je više tipova kapacitivnih razdelnika napona izuzetno dobrih karakteristika. Na osnovu dobijenih rezultata je odabran kapacitivni razdelnik napona najboljih karakteristika i izražena je njegova merna nesigurnost, This thesis contains an analysis of the possibilities for measurement of very fast pulse voltages and proper expression of measurement uncertainty. It has been proven that it is possible to perform numerical simulation to the response of the very fast pulse voltage with rise time at the order of picoseconds of the measuring system. Measurement uncertainty of capacitive voltage dividers is expressed by Monte Carlo method. The way of constructing capacitive voltage dividers with a waveguide resistance is shown in this thesis. The design of four types of capacitive voltage dividers with extremely good features are shown. Based on these results, capacitive voltage divider with best characteristics is selected and its measurement uncertainty is expressed.
- Published
- 2017
31. Detekcija nule A/D konvertorom niske rezolucije
- Author
-
Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Spasić-Jokić, Vesna, Pejić, Dragan, Vujičić, Bojan, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Spasić-Jokić, Vesna, Pejić, Dragan, and Vujičić, Bojan
- Abstract
U tezi je rešavan centralni problem – detekcija nule dvobitnom stohastičkom digitalnom mernom metodom (SDMM). Formulisane su dve metode detekcije nule primenom dvobitne SDMM. Po prvoj metodi dinamička rezerva je oko 100 dB a po drugoj ne manje od 160 dB. Obe metode su proverene teorijski, simulaciono i eksperimentalno. Pored rešenja centralnog problema, dato je i nekoliko rešenja problema koji su sa njim vezani. Hipoteza ove teze – „dvobitna SDMM je u opsegu 0 % - 10% FS bolja od standardne sempling metode (SSM)“ – je potpuno potvrđena u svim razmatranim slučajevima., The main goal of this thesis was null-detection using a two-bit stochastic digital measurement method (SDMM). Two methods of null-detection, using two-bit SDMM, were formulated. Using the first method around 100 dB of dynamic reserve was achieved and using the second one no less than 160 dB. Both methods were theoretically, using simulation and experimentally confirmed. In addition to the solution of the main problem, several other related problems were also solved. The hypothesis of this thesis – “two-bit SDMM in range from 0 % - 10 % FS is better than the standard sampling method (SSM)” has been fully confirmed in all considered cases.
- Published
- 2017
32. Accuracy improvement of the stochastic digital electrical energy meter
- Author
-
Urekar, Marjan, Urekar, Marjan, Pejić, Dragan, Vujičić, Vladimir, Avramov Zamurović, Svetlana, Urekar, Marjan, Urekar, Marjan, Pejić, Dragan, Vujičić, Vladimir, and Avramov Zamurović, Svetlana
- Abstract
The paper describes the problem and a solution for the elimination of the systematic error in a stochastic flash ADC caused by the offset present in fast voltage comparators, when measuring voltage RMS and active power and energy using the stochastic digital measurement method. By the means of simple periodical cross-switching of inverting and non-inverting inputs of used comparators and inverting their digital outputs, it is possible to suppress offset induced error for over 80 dB. Main condition for the method is that input signals (one for voltage RMS measurement, two for power and energy measurements) are stationary during at least two (or even number) of signal cycles. A prototype of a stochastic energy meter was built. It has the offset suppression method implemented, based on the solution proposed in the paper. The prototype was used for measurements in a laboratory, in an industrial plant and on a large power load. The measurement results confirm high accuracy of the instrument and validity of its aforementioned condition. The stochastic digital electrical energy meter prototype has 0.13% accuracy while the stochastic measurement instrument in its core has 0.007% accuracy. High precision and high accuracy of the stochastic instrument enables it to be used as a reference meter for calibration of energy meters at the national level. Full measurement results are presented.
- Published
- 2017
33. Use of integrative ADC for Electrochemical Impedance Spectroscopy of supercapacitor module under high interference conditions
- Author
-
Šaš, Milan, Vukajlović, Nikola, Pejić, Dragan, Milićević, Dragan, Novaković, Đorđe, and Gazivoda, Nemanja
- Abstract
This paper demonstrates the use of integrative analog-to-digital converter (IADC) based data acquisition for conducting Electrochemical Impedance Spectroscopy (EIS) procedure in order to obtain the frequency response of high voltage/current supercapacitor (SC) module under high interference conditions. Herein proposed approach presents the method to suppress the influence of voltage and current harmonics on measured data, thus ensuring insignificant errors in obtained results. Dedicated laboratory equipment for acquiring frequency response is usually only capable of testing low voltage/current SC cells. However, it is essential to be able to conduct EIS on high voltage/current SC with voltage/current levels, which are expected during exploitation. It is shown that by using the IADC together with the herein proposed data fitting method, noise is suppressed by factor of 44.2 dB compared to the sampling ADC, over the analyzed frequency range between 10 kHz and 20 kHz. In addition, it was shown that in case of herein treated SC cells the expanded uncertainty for magnitude and phase are less than 0.21 mΩ and 0.75°, respectively, which are at the level of declared reference instrument errors. Furthermore, in case of SC module, obtained results for expanded magnitude and phase uncertainty are less than 6 mΩ and 0.022°, respectively. It is concluded that herein proposed method offers the measurement capability at the level of used reference instrument for considered frequency range.
- Published
- 2024
- Full Text
- View/download PDF
34. Metoda merenja harmonika u realnoj distributivnoj mreži primenom A/D konvertora dvobitne rezolucije
- Author
-
Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Spasić-Jokić, Vesna, Pejić, Dragan, Beljić, Željko, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Spasić-Jokić, Vesna, Pejić, Dragan, and Beljić, Željko
- Abstract
U disertaciji je prikazano teorijsko i praktično istraživanje koje se odnosi na utvrđivanje potrebnih i dovoljnih uslova za merenje harmonika u realnoj elektrodistributivnoj mreži. Cilj istraživanja doktorske disertacije je formulisanje merne metode i na metodi baziranom hardveru - po mogućnosti minimalne rezolucije primenjenih A/D konvertora - praktično dvobitnih za merenje harmonika u realnoj elektrodistributivnoj mreži. Jednostavan hardver omogućuje jednostavna paralelna merenja, kao i mali broj izvora sistematske greške merenja, što je vrlo primenljivo u merenjima u realnoj distributivnoj mreži.Simulacionom analizom, a potom i eksperimentom potvrđena je hipoteza istraživanja., The dissertation shows the theoretical and practical research related to the determination of necessary and sufficient conditions for the measurement of harmonics in a real power grid. The aim of the PhD research is to formulate method and hardware based on the measurement method - preferably with minimal resolution of applied A/D converter - practically 2-bit, for harmonics measurement in a real power grid. Simple hardware allows simple parallel measurements, as well as a small number of systematic measurement error, which is applicable for measurement in the real power grid. Simulation analysis, followed by the experiment, confirmed the hypothesis of this research.
- Published
- 2016
35. Стохастичка метода мерења напона и струје на високом напону
- Author
-
Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, Antić, Boris, Čomić, Dušan, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, Antić, Boris, and Čomić, Dušan
- Abstract
У раду je обрађен проблем мерења високог напона и струје у несинусидалној високонапонској мрежи, стање технике, предлог решења које подразумева неконвенционални начин мерења ових величина, практично израђен прототип и извршена потребна мерења која су потврђена теоријски. Мерење напона у високонапонској мрежи се врши напонским мерним трансформатором без језгра и интегрисаним мерилом хармоника (IMH), а затим се стохастичком методом мере хармоници напона, смерови и протоци снаге, односно енергије. За мерења струје на високом напону предлаже се калем Роговског и стохастичка метода мерења. Стохастичка метода мерења је заснована на додавању дитерског случајног сигнала на мерени сигнал. Сметње и присуство виших хармоника у мрежном сигналу су, за ову методу, додатни дитерски сигнали који методи не смањују тачност мерења., U radu je obrađen problem merenja visokog napona i struje u nesinusidalnoj visokonaponskoj mreži, stanje tehnike, predlog rešenja koje podrazumeva nekonvencionalni način merenja ovih veličina, praktično izrađen prototip i izvršena potrebna merenja koja su potvrđena teorijski. Merenje napona u visokonaponskoj mreži se vrši naponskim mernim transformatorom bez jezgra i integrisanim merilom harmonika (IMH), a zatim se stohastičkom metodom mere harmonici napona, smerovi i protoci snage, odnosno energije. Za merenja struje na visokom naponu predlaže se kalem Rogovskog i stohastička metoda merenja. Stohastička metoda merenja je zasnovana na dodavanju diterskog slučajnog signala na mereni signal. Smetnje i prisustvo viših harmonika u mrežnom signalu su, za ovu metodu, dodatni diterski signali koji metodi ne smanjuju tačnost merenja., A problem of measurement of high voltage and current in non-sinusoidal grid is given in the thesis, along with the current state in the field, the proposed non-conventional measurement method for these values, the realized prototype and the necessary measurement results that are confirmed theoretically. Measurement of voltage in high-voltage grid is performed using the coreless high voltage transformer and the Integrated harmonic measurement device (IMH). The stochastic method is used to measure harmonics of voltage, direction and flow of power and energy. For current measurement at high voltage level a Rogowski coil along with the Stochastic measurement method is proposed. Stochastic measurement method is based on adding a arbitrary dither signal to the measured signal. Disturbances and pollution of the grid signal are, for this method, additional dither signals that do not lower the measurement accuracy.
- Published
- 2015
36. A Proposal of a Novel Method for Generating Discrete Analog Uniform Noise.
- Author
-
PEJIĆ, Dragan, GAZIVODA, Nemanja, LIČINA, Boris, UREKAR, Marjan, SOVILJ, Platon, and VUJIČIĆ, Bojan
- Subjects
DIGITAL-to-analog converters ,COMPUTER simulation ,PSEUDONOISE sequences (Digital communications) ,DISCRETE systems ,PROBABILITY density function - Abstract
This paper presents a proposal of a new way to generate analog noise, discrete in time, with uniform probability density function. Instead of the usual way of generating discrete analog uniform noise using a uniform pseudorandom number generator and a digital-to-analog converter, generating based on non-equidistant sampling of sawtooth voltage is suggested. The original hardware structure that implements this idea is suggested and its work is simulated. The simulations have confirmed the validity of the idea. The main gain is the unlimited resolution of the analog output of the uniform noise generator suggested. The resolution of standard uniform noise generators is limited by the resolution of the digital-to-analog converter used. [ABSTRACT FROM AUTHOR]
- Published
- 2018
- Full Text
- View/download PDF
37. Timing in ERP Measurement Software
- Author
-
Beljić, Željko, Sovilj, Platon, Pinter, Akos, Ković, Vanja, Pejić, Dragan, Beljić, Željko, Sovilj, Platon, Pinter, Akos, Ković, Vanja, and Pejić, Dragan
- Abstract
Measurement of event related potentials have significant role as a diagnostic method, as well as a method for researching cognitive functions of living beings. An important aspect of this measurement is timing. In this paper, one concept of structuring time intervals during the measurement is presented. Further, the implementation of this concept in measurement software is described, emphasizing algorithm in which stimuli events markers are being received directly from the software unit which controls starts of each stimuli presentation.
- Published
- 2013
38. Influence of Signal Stationarity on Digital Stochastic Measurement Implementation
- Author
-
Sovilj, Platon, primary, Vujičić, Vladimir, additional, Pjevalica, Nebojša, additional, Pejić, Dragan, additional, Urekar, Marjan, additional, and Župunski, Ivan, additional
- Published
- 2013
- Full Text
- View/download PDF
39. The method for extending the frequency range of the RF power sensor calibration
- Author
-
Spasojević, Neda, Mitrović, Zoran, Urekar, Marjan, Denić, Dragan, Sovilj, Platon, Pejić, Dragan, Antić, Boris, and Brkljač, Branko
- Subjects
RF snaga, senzor snage, etalon, termopretvarač, faktor etaloniranja, etaloniranje, merna nesigurnost ,РФ снага, сензор снаге, еталон, термопретварач, фактор еталонирања, еталонирање, мерна несигурност ,RF power, power sensor, standard, thermal converter, calibration factor, calibration, measurement uncertainty - Abstract
Teма дисертације је унапређен метод еталонирања радио-фреквенцијских (РФ) сензора снаге у фреквенцијском опсегу испод 10 МHz. Метод подразумева одређивање фактора еталонирања комерцијалних сензора средње снаге, као најбитније карактеристике која се проверава приликом њиховог еталонирања. Критичне тачке у реализацији метода су биле селекција одговарајућег еталона РФ снаге у опсегу ниских фреквенција и постизање прихватљиве мерне несигурности. С обзиром да је један од основних услова истраживања био да се развијени метод реализује применом мерне опреме којом располаже већина метролошких лабораторија из области РФ домена, што подразумева одсуство типичног еталона РФ снаге у поменутом опсегу, одабрани еталон је требало да задовољи различите услове по питању својих метролошких карактеристика. Међутим, изналажење одговарајућег еталона је био неопходан, али не и довољан услов за успешну реализацију метода. Формирање мерног ланца и успостављање таквог мерног поступка који ће обезбедити прихватљиву мерну несигурност, овом истраживању даје посебан значај. Дисертација обухвата анализу постојећих еталона РФ снаге и метода еталонирања сензора РФ снаге, развој новог метода, анализу мерне несигурности и постигнута побољшања метода са резултатима мерења. Побољшање метода се односи на вишеструко смањење мерне несигурности. Валидација метода еталонирања сензора је извршена у Техничком опитном центру Војске Србије, поређењем експерименталних резултата са познатим вредностима фактора еталонирања различитих типова сензора. Реализованим истраживањем успешно је потврђена дефинисана хипотеза дисертације да се може реализовати метод еталонирања сензора снаге у опсегу испод 10 MHz при одсуству одговарајућег еталона РФ снаге са прихватљивом мерном несигурношћу. Крајњи резултат истраживања јесте успостављена следивост РФ снаге у фреквенцијском опсегу испод 10 МHz, на основу које су проширене мерне могућности метролошке лабораторије Техничког опитног центра Војске Србије. Корисницима мерне опреме метод обезбеђује следивост РФ снаге у опсегу ниских фреквенција и смањење несигурности мерења РФ снаге сензорима и до седамдесет процената, корекцијом резултата мерења на основу добијених фактора еталонирања. Различите теоријске и практичне анализе, експериментални резултати и на основу њих донети закључци, спроведеном истраживању дају технички и научни значај за РФ метролологију у целини. Tema disertacije je unapređen metod etaloniranja radio-frekvencijskih (RF) senzora snage u frekvencijskom opsegu ispod 10 MHz. Metod podrazumeva određivanje faktora etaloniranja komercijalnih senzora srednje snage, kao najbitnije karakteristike koja se proverava prilikom njihovog etaloniranja. Kritične tačke u realizaciji metoda su bile selekcija odgovarajućeg etalona RF snage u opsegu niskih frekvencija i postizanje prihvatljive merne nesigurnosti. S obzirom da je jedan od osnovnih uslova istraživanja bio da se razvijeni metod realizuje primenom merne opreme kojom raspolaže većina metroloških laboratorija iz oblasti RF domena, što podrazumeva odsustvo tipičnog etalona RF snage u pomenutom opsegu, odabrani etalon je trebalo da zadovolji različite uslove po pitanju svojih metroloških karakteristika. Međutim, iznalaženje odgovarajućeg etalona je bio neophodan, ali ne i dovoljan uslov za uspešnu realizaciju metoda. Formiranje mernog lanca i uspostavljanje takvog mernog postupka koji će obezbediti prihvatljivu mernu nesigurnost, ovom istraživanju daje poseban značaj. Disertacija obuhvata analizu postojećih etalona RF snage i metoda etaloniranja senzora RF snage, razvoj novog metoda, analizu merne nesigurnosti i postignuta poboljšanja metoda sa rezultatima merenja. Poboljšanje metoda se odnosi na višestruko smanjenje merne nesigurnosti. Validacija metoda etaloniranja senzora je izvršena u Tehničkom opitnom centru Vojske Srbije, poređenjem eksperimentalnih rezultata sa poznatim vrednostima faktora etaloniranja različitih tipova senzora. Realizovanim istraživanjem uspešno je potvrđena definisana hipoteza disertacije da se može realizovati metod etaloniranja senzora snage u opsegu ispod 10 MHz pri odsustvu odgovarajućeg etalona RF snage sa prihvatljivom mernom nesigurnošću. Krajnji rezultat istraživanja jeste uspostavljena sledivost RF snage u frekvencijskom opsegu ispod 10 MHz, na osnovu koje su proširene merne mogućnosti metrološke laboratorije Tehničkog opitnog centra Vojske Srbije. Korisnicima merne opreme metod obezbeđuje sledivost RF snage u opsegu niskih frekvencija i smanjenje nesigurnosti merenja RF snage senzorima i do sedamdeset procenata, korekcijom rezultata merenja na osnovu dobijenih faktora etaloniranja. Različite teorijske i praktične analize, eksperimentalni rezultati i na osnovu njih doneti zaključci, sprovedenom istraživanju daju tehnički i naučni značaj za RF metrolologiju u celini. The topic of this dissertation is an improved method for radio-frequency (RF) power sensor calibration within the frequency range below 10 MHz. The method involves the calibration factor determination of commercial RF power sensors, as the most important characteristic, which measures during their calibration. The critical points in the method realization were the selection of the appropriate RF power standard in the low-frequency range and the achievement of acceptable measurement uncertainty. Given that one of the basic conditions of the research was that the developed method be realized with measuring equipment available to most metrology laboratories in the field of RF domain, which implies the absence of a typical RF power standard in the mentioned range, the selected standard had to satisfy various conditions terms of its metrological characteristics. However, the selection of an appropriate standard was a requirement but not a sufficient condition for the successful method implementation. The forming of the measuring chain and the establishment of such a measurement procedure that provided acceptable measurement uncertainty, gave this research a special importance. The dissertation includes the analysis of the existing RF power standards and methods for RF power sensor calibration, the development of a new method, the analysis of a measurement uncertainty, improvement of the achieved method and experimental measurement results. The method improvement refers to the multiple reduction of measurement uncertainty. Validation of the method for power sensor calibration was performed at the Technical Test Center of Serbian Armed Forces, by comparing experimental results with known calibration factor values of different types of sensors. The possibility to realize the method for power sensor calibration in the range below 10 MHz in the absence of an appropriate RF power standard with acceptable measurement uncertainty is the hypothesis of the dissertation, which is confirmed by the successful realization of this research. The final result of the research is the established traceability of RF power in the frequency range below 10 MHz, which lead to the Technical Test Center of Serbian Armed Forces measuring capabilities expansion. The method ensures users the traceability of RF power within the low-frequency range and the reduction of the uncertainty of RF power measurements by sensors up to seventy percent, by applying the correction of measurement results using the obtained calibration factor values. Various theoretical and practical analyses, experimental results and derived conclusions, give the conducted research the technical and scientific importance for RF metrology as a whole.
- Published
- 2023
40. Prilog određivanju merne nesigurnosti u slučaju korelisanih veličina
- Author
-
Novaković, Đorđe, Pejić, Dragan, Sovilj, Platon, Denić, Dragan, Grbić, Tatjana, Medić, Slavica, and Urekar, Marjan
- Subjects
FOLD метода, Мерна несигурност, случаjне променљиве са униформном расподелом, Монте Карло метода ,FOLD method, uncertainty, uniformly distributed random variable, Monte Carlo method ,FOLD metoda, Merna nesigurnost, slučajne promenljive sa uniformnom raspodelom, Monte Karlo metoda - Abstract
У дисертациjи jе представљена нова FOLD метода за генерисање случаjних променљивих са дефинисаним коефициjентом корелациjе, као и њена примена у одређивању мерне несигурности Монте Карло методом. Извршено jе поређење развиjене FOLD методе и стандардно коришћене MVUD методе по времену извршавања, као и по одступању добиjеног од задатог коефициjента корелациjе. Показано jе да jе нова метода ефикасниjа по оба критериjума. Примена FOLD методе у метрологиjи дата jе кроз поређење мерне несигурности корелисаних величина одређене на основу препорука датих GUM-ом и Монте Карлометоде. Извршен jе експеримент за одређивање фактора дељења отпорничког делитеља., U disertaciji je predstavljena nova FOLD metoda za generisanje slučajnih promenljivih sa definisanim koeficijentom korelacije, kao i njena primena u određivanju merne nesigurnosti Monte Karlo metodom. Izvršeno je poređenje razvijene FOLD metode i standardno korišćene MVUD metode po vremenu izvršavanja, kao i po odstupanju dobijenog od zadatog koeficijenta korelacije. Pokazano je da je nova metoda efikasnija po oba kriterijuma. Primena FOLD metode u metrologiji data je kroz poređenje merne nesigurnosti korelisanih veličina određene na osnovu preporuka datih GUM-om i Monte Karlometode. Izvršen je eksperiment za određivanje faktora deljenja otporničkog delitelja., Тhe dissertation proposes a new FOLD method for generating random variables with aprescribed correlation coefficient, as well as its application in determining the measurement uncertainty using the Monte Carlo method. A comparison of the developed FOLD method and the standard MVUD method was performed according to the execution time, as well as the difference between the sample and the prescribed correlation coefficient. It has been shown that the new method is more efficient according to both criteria. The application of the FOLD method in the field of electrical measurement is given through the comparison of the measurement uncertainty of the correlated quantities determined on the basis of the recommendations given by the GUM and Monte Carlo methods. An experiment was performed to determine the ratio of the resistor divider.
- Published
- 2022
41. Metoda za merenje i korekciju nelinearnosti senzora mikrotalasne snage
- Author
-
Rakonjac, Predrag, Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, Antić, Boris, and Urekar, Marjan
- Subjects
Еталонирање сензора снаге, Корекција нелинеарности сензора снаге, Микроталасна снага, Мерна несигурност, Нелинеарност сензора снаге, Сензор микроталасне снаге, Фактор еталонирања ,Calibration factor, Microwave power, Measurement uncertainty, Nonlinearitycorrection of microwave power sensor, Power sensor, Power sensorcalibration, Power sensor nonlinearity ,Etaloniranje senzora snage, Korekcija nelinearnosti senzora snage, Mikrotalasna snaga, Merna nesigurnost, Nelinearnost senzora snage, Senzor mikrotalasne snage, Faktor etaloniranja - Abstract
У дисертацији је развијена и представљена унапређена метода и аутоматизовани мерни систем за еталонирање сензора микроталасне снаге која омогућава еталонирање сензора и истовремено одређивање нелинеарности сензора снаге, узимајући у обзир амплитудску и фреквенцијску зависност нелинеарности. Унапређена метода еталонирања заснива се на примени термисторског трансфер еталона високе линеарности и еталонирању сензора на више нивоа снаге. Процес еталонирања сензора снаге је у потпуности аутоматизован и унапређен применом аутоматизованог мерног система, РС рачунара и софтвера VEEpro. Извршени прорачун мерне несигурности еталонирања сензора и анализа буџета несигурности мерења снаге указују на то да унапређена метода еталонирања омогућава максималну корекцију нелинеарности сензора и доприноси значајном смањењу несигурности мерења микроталасне снаге. Тиме се битно унапређују мерне карактеристике сензора снаге без хардверске или софтверске дораде. Реализована валидација потврђује примењивост и високе перформансе унапређене методе еталонирања. Експериментални резултати мерења доказују постојање значајне зависности нелинеарности сензора од нивоа снаге, али и од фреквенције мерене микроталасне снаге. Тиме су потврђене главна и помоћна хипотеза докторске дисертације. Примена унапређене методе еталонирања може значајно унапредити мерне карактеристике микроталасних ватметара са сензорима снаге и утицати на промену постојећег начина мерења нелинеарности сензора снаге (на једној фреквенцији)., U disertaciji je razvijena i predstavljena unapređena metoda i automatizovani merni sistem za etaloniranje senzora mikrotalasne snage koja omogućava etaloniranje senzora i istovremeno određivanje nelinearnosti senzora snage, uzimajući u obzir amplitudsku i frekvencijsku zavisnost nelinearnosti. Unapređena metoda etaloniranja zasniva se na primeni termistorskog transfer etalona visoke linearnosti i etaloniranju senzora na više nivoa snage. Proces etaloniranja senzora snage je u potpunosti automatizovan i unapređen primenom automatizovanog mernog sistema, RS računara i softvera VEEpro. Izvršeni proračun merne nesigurnosti etaloniranja senzora i analiza budžeta nesigurnosti merenja snage ukazuju na to da unapređena metoda etaloniranja omogućava maksimalnu korekciju nelinearnosti senzora i doprinosi značajnom smanjenju nesigurnosti merenja mikrotalasne snage. Time se bitno unapređuju merne karakteristike senzora snage bez hardverske ili softverske dorade. Realizovana validacija potvrđuje primenjivost i visoke performanse unapređene metode etaloniranja. Eksperimentalni rezultati merenja dokazuju postojanje značajne zavisnosti nelinearnosti senzora od nivoa snage, ali i od frekvencije merene mikrotalasne snage. Time su potvrđene glavna i pomoćna hipoteza doktorske disertacije. Primena unapređene metode etaloniranja može značajno unaprediti merne karakteristike mikrotalasnih vatmetara sa senzorima snage i uticati na promenu postojećeg načina merenja nelinearnosti senzora snage (na jednoj frekvenciji)., This thesis introduces the developed, improved method and automated measuring system formicrowave power sensor calibration and simultaneous determination of power sensor nonlinearity,taking into account its dependence on amplitude and frequency. The novel calibration method isbased on the application of high-linearity thermistor power transfer standard and sensor calibrationat multiple power levels. The power sensor calibration process is fully automated and improved byapplying the automated measuring system, PC and VEEpro software. Performed calculation of thesensor calibration measurement uncertainty and the analysis of power measurement uncertaintybudget indicate that the new calibration method allows for the maximum correction of sensornonlinearity and contributes to significant reduction of the microwave power measurementuncertainty. This considerably improves power sensor measuring characteristics without hardwareor software upgrades. Performed validation confirms the applicability and high performance of theimproved calibration method. Experimental results prove the existence of significant dependence ofsensor nonlinearity on the power level, but also on the frequency of the measured microwavepower. This confirms main and auxiliary hypothesis of the thesis. The application of developedcalibration method can significantly improve power sensor and power meter measuringcharacteristics and change the currently used method for power sensor nonlinearity measurement(measurement at a single frequency).
- Published
- 2022
42. Projektovanje, metrološka analiza i optimizacija solenoida u svrhu homogenizacije elektromagnetskog polja za biomedicinske eksperimente
- Author
-
Gajić, Slavica, Sovilj, Platon, Pejić, Dragan, Simić, Mitar, Ćirković, Saša, Kasaš-Lažetić, Karolina, and Urekar, Marjan
- Subjects
Bioengineering, Modeling, Metrological Analysis, Optimization, Solenoids, Electromagnetic Field ,Bioinženjering, projektovanje, metrološka analiza, optimizacija, solenoid, elektromagnetsko polje - Abstract
Jedan od doprinosa ove disertacije je projektovanje i optimizacijasolenoida u svrhu homogenizacije elektromagnetskog polja solenoida zabiomedicinske eksperimente. U radu je izvršena metrološka analizapredloženog rješenja, te se njegova uspješnost testirala numeričkim isimulacionim putem. Uvedeni su relativni odnosi dimenzija kojiomogućavaju primjenu predloženog rješenja u velikom broju aplikacijaza različite dimenzije eksperimentalne zapremine i zahtjevane nivoepolja. Takođe, izvršena je i hardverska realizacija prototipapredloženog rješenja, te je njegova efikasnost testirana i potvrđenaprilikom poređenja sa aktuelnim sistemima iz literature.
- Published
- 2021
43. Metoda merenja snage i energije vetra zasnovana na merenju na intervalu
- Author
-
Ličina, Boris, Sovilj, Platon, Pejić, Dragan, Pilipović, Stevan, Kovačević, Dragan, Mitrović, Zoran, and Urekar, Marjan
- Subjects
Stohastička merna metoda, Merenje snage vetra, Merenje energije vetra, Dvobitni AD konvertor, Anemometar sa šoljicama ,Anemometar sa šoljicama ,Wind energy measurement ,Merenje energije vetra ,Stochastic measurement method ,Stohastička merna metoda ,Wind power measurement ,Cup anemometer ,Dvobitni AD konvertor ,Two-bit AD converter ,Merenje snage vetra ,Stochastic measurement method, Wind power measurement, Wind energy measurement, Two-bit AD converter, Cup anemometer - Abstract
U disertaciji je prikazan i predložen novi metod merenja snagei energije vetra koji se bazira na stohastičkoj digitalnoj mernojmetodi (SDMM), umesto do sada korišćene standardne semplingmetode (SSM). Standard za merenje brzine vetra predstavljaanemometar sa šoljicama, koji na svom izlazu daje sinusni napončija su amplituda i frekvencija linearno zavisne od brzinevetra. Kako su snaga i energija vetra proporcionalne trećemstepenu brzine vetra, u tu svrhu se primenjuje generalizovanhardver namenjen za računanje proizvoda tri ulazna signala. Zbogniskog frekvencijskog opsega ulaznog signala izvršeno jeznačajno pojednostavljenje hardvera mernog uređaja. Teorijskomanalizom, simulacijom, a potom i eksperimentom potvrđena jehipoteza istraživanja, da se SDMM uspešno može koristiti zamerenje snage i energije vetra., In this dissertation а new wind power and energy measurementmethod, based on Stochastic Digital Measurement Method (SDMM),was elaborated and proposed, to replace the commonly used StandardSampling Method (SSM). The standard for wind speed measurement isa cup anemometer that provides a sinusoidal voltage on its output,having the amplitude and frequency linearly dependent of the windspeed. Since the wind power and energy are proportional to the thirddegree of the wind speed, the general case hardware has been designedfor the product calculation over three input signals. The low frequencyrange of the input signal allows for a significant simplification of themeasuring instrument hardware. By theoretical analysis andsimulation, and consequently through an experiment the hypothesis ofthis research was confirmed - that SDMM can be successfully used tomeasure wind power and energy.
- Published
- 2020
44. Nova metoda za povećanje efektivne rezolucije stohastičkih mernih instrumenata visokih performansi
- Author
-
Gazivoda, Nemanja, Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, and Urekar, Marjan
- Subjects
Стохастичка дигитална мерна метода ,pseudoslučajni generatori brojeva ,ефективна резолуција ,metoda ,diterski signali ,True Random Number Generators ,efektivna rezolucija ,мерна несигурност ,Method ,дитерски сигнали ,Dither signals ,Pseudorandom Number Generators ,Стохастичка дигитална мерна метода, дитерски сигнали, псеудослучајни генератори бројева, истински случајни генератори бројева, метода, ефективна резолуција,мерна несигурност ,Measurement Uncertainty ,Stochastic Digital Measurement Method ,istinski slučajni generatori brojeva ,псеудослучајни генератори бројева ,Stohastička digitalna merna metoda, diterski signali, pseudoslučajni generatori brojeva, istinski slučajni generatori brojeva, metoda, efektivna rezolucija,merna nesigurnost ,истински случајни генератори бројева ,Effective Resolution ,merna nesigurnost ,Stochastic Digital Measurement Method, Dither signals, Pseudorandom Number Generators, True Random Number Generators, Method, Effective Resolution, Measurement Uncertainty ,Stohastička digitalna merna metoda ,метода - Abstract
Дисертација истражује утицај примене дитерског сигнала (дискретног аналогног униформног шума) генерисаног новом методом на повећање ефективне резолуције мерних инструмената базираних на стохастичкој дигиталној мерној методи. У дисертацији је дат преглед досадашњих решења базираних на стохастичкој дигиталној мерној методи у циљу сагледавања потребе и оправданости истраживања. Предложено решење представља комбинацију псеудослучајног и истински случајног генератора и као такво задржава најбоље особине из обе области. Дaт je прeдлoг нoве методе гeнeрисaњa шумa унифoрмнe рaспoдeлe aмплитудa. Умeстo уoбичajeнoг нaчинa гeнeрисaњa кoришћeњeм гeнeрaтoрa псeудoслучajних брojeвa и Д/А кoнвeртoрa, oвдe сe прeдлaжe гeнeрисaњe зaснoвaнo нa нeунифoрмнoм одабирању тeстeрaстoг или троугаоног нaпoнa. Oсим уштeдe збoг нeкoришћeњa Д/А кoнвeртoрa, дoбит je и мoгућнoст гeнeрисaњa нaпoнa из кoнтинуалнoг, умeстo дискрeтнoг скупa aмплитудa. Вeћинa дaнaшњих хaрдвeрских гeнeрaтoрa псeудoслучajнoг нaпoнa, сe бaзирa нa употреби микрoкoнтрoлeра и Д/A кoнвeртoра, пa je нa тaj нaчин рeзoлуциja гeнeрисaњa псeудoслучajнoг нaпoнa oгрaничeнa резолуцијом Д/A кoнвeрторa. Одабирањем тестерастог или троугаоног напона предложеном методом се остварује готово неограничена резолуција. Употреба овако генерисаног дитерског сигнала доводи до повећања ефективне резолуције код стохастичких мерних инстурмената. Симулацијом је одређена оптимална структура генератора на основу предложене методе. Експериментална мерења су изведена помоћу развијеног прототипа хардверског генератора., Disertacija istražuje uticaj primene diterskog signala (diskretnog analognog uniformnog šuma) generisanog novom metodom na povećanje efektivne rezolucije mernih instrumenata baziranih na stohastičkoj digitalnoj mernoj metodi. U disertaciji je dat pregled dosadašnjih rešenja baziranih na stohastičkoj digitalnoj mernoj metodi u cilju sagledavanja potrebe i opravdanosti istraživanja. Predloženo rešenje predstavlja kombinaciju pseudoslučajnog i istinski slučajnog generatora i kao takvo zadržava najbolje osobine iz obe oblasti. Dat je predlog nove metode generisanja šuma uniformne raspodele amplituda. Umesto uobičajenog načina generisanja korišćenjem generatora pseudoslučajnih brojeva i D/A konvertora, ovde se predlaže generisanje zasnovano na neuniformnom odabiranju testerastog ili trougaonog napona. Osim uštede zbog nekorišćenja D/A konvertora, dobit je i mogućnost generisanja napona iz kontinualnog, umesto diskretnog skupa amplituda. Većina današnjih hardverskih generatora pseudoslučajnog napona, se bazira na upotrebi mikrokontrolera i D/A konvertora, pa je na taj način rezolucija generisanja pseudoslučajnog napona ograničena rezolucijom D/A konvertora. Odabiranjem testerastog ili trougaonog napona predloženom metodom se ostvaruje gotovo neograničena rezolucija. Upotreba ovako generisanog diterskog signala dovodi do povećanja efektivne rezolucije kod stohastičkih mernih insturmenata. Simulacijom je određena optimalna struktura generatora na osnovu predložene metode. Eksperimentalna merenja su izvedena pomoću razvijenog prototipa hardverskog generatora., The dissertation investigates the impact of the application of the dithering signal (discrete analogue uniform noise) generated by the new method for increasing the effective resolution of measurement instruments based on the stochastic digital measurement method. The dissertation provides an overview of the existing solutions based on the stochastic digital measurement method in order to understand the need and justification of the research. The proposed solution represents a combination of a pseudorandom and truly random generator and as such holds the best features in both areas. А suggestion of a new way of generating the noise of the uniform distribution of amplitudes is presented. Instead of the usual way of generating using a pseudorandom number generator and a D/A converter, the generation based on the nonuniform sampling of sawtooth or triangle voltage is proposed. In addition to the savings due to the non-use of a D/A converter, the possibility of generating voltages from a continual instead of a discrete amplitude set is also obtained. Most of today's hardware pseudorandom voltage generators are based on the use of a microcontroller and D/A converter, so in this way the resolution of the pseudorandom voltage generation is limited by the resolution of the D/A converter. By sampling the sawtooth or triangle voltage using the proposed method, almost unlimited resolution is achieved. The use of this generated dither signal leads to an increase in effective resolution in stochastic measuring instruments. The simulation determined the optimal structure of the generator based on the proposed method. Experimental measurements were made using developed hardware.
- Published
- 2019
45. Prilog savremenom etaloniranju strujnih mernih transformatora
- Author
-
Naumović-Vuković, Dragana, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, and Antić, Boris
- Subjects
intercompaison ,jednovremenauporedna metoda etaloniranja ,međulaboratorijsko poređenje ,simultaneous method ,measuring system ,calibration ,interkomparacija ,uncertainty of measurement ,merna aparatura ,strujni transformator ,two stagecurrent transformer ,Current transformer ,merni sistem ,merna nesigurnost ,standard current transformer ,current comparator ,etaloniranje - Abstract
U ovoj doktorskoj disertaciji prikazana je koncepcija, realizacija i potvrda nove metode jednovremenog etaloniranja strujnih mernih transformatora sa dve različite merne aparature. Pregledom stručne literature ne postoji podatak da je ova metoda ranije primenjivana. U disertaciji su prikazane različite merne metode za ispitivanje i etaloniranje mernih transformatora koje imaju primenu u savremenoj praksi i koje podrazumevaju i različite merne mogućnosti. Takođe je i ekperimentalno potvrđeno jednovremeno ispitivanje i etaloniranje strujnih mernih transformatora sa nekoliko mernih aparatura koje su zasnovane na različitim metodama. Sprovedna istraživanja i eksperimentalni rezultati pokazuju i potvrđuju niz prednosti ovakvog načina etaloniranja. Detaljna analiza komponenti merne nesigurnosti pokazala je da se primenom ove metode postiže poboljšanje merne nesigurnost etaloniranja za skoro red veličine u odnosu na klasično pojedinačno etaloniranje sa dve različite merne aparature. Analiza uticajnih veličina na mernu nesigurnost pokazuje da se po ovoj novoj metodi etaloniranja eliminiše niz komponenti od kojih su najznačajnije: uticaj nejednakosti referentnih struja i ispitnog opterećenja. Istraživanja su takođe pokazala da jednovremena metoda osim što doprinosi podizanju tačnosti etaloniranja strujnih transformatora, ima primenu i u etaloniranju mernih aparatura za ispitivanje tačnosti mernih transformatora i interkonparaciji strujnih etalon transformatora. Kroz konkretne primere realizovane u praksi, razmotreni su i prikazani načini etaloniranja mernih aparatura za ispitivanje tačnosti ovom novom metodom. Interkomparacijom dva merna sistema visoke klase tačnosti Nacionalnog merološkog instituta Kanade (National Research Council Canada), od kojih je jedna razvijena u Elektrotehničkom Institutu "Nikola Tesla", pokazana je i prednost primene jednovremene metode u oblasti primarne metrologije strujnih mernih transformatora. The dissertation presents the concept, its realisation and verification of the new method of simultaneous comparison of the current transformers by two different measuring apparatus. It is shown by searching the literature, that this method has not been used before. In this dissertation different measuring methods for testing and calibration of current transformers, with their different measuring capabilities are presented. Most of them have been used in recent practice. Furthermore, the experimental verification of new simultaneous calibration method is presented. For this reason some measuring apparatus based on different measuring methods were used. Conducted research and experimental results confirmed a number of advantages of this calibration method. Detailed analysis of the components of the uncertainty of measurements shown that using simultaneous method uncertainty of measurements have been improved comparing to method with two individual calibration by different apparatus. In that case some of the measuring uncertainty components can be neglected. The most significant is component caused by variation of referent current and component caused by variation of burden. The research has also showed that simultaneous method can be used for calibration of measuring apparatus for current transformer accuracy testing and their inter-comparisons. The ways of calibration of apparatus for current transformer accuracy testing are considered and presented, through concrete examples realized in practice. A high-accuracy comparison of two NRC (National Research Council Canada) calibration systems were carried out by new simultaneous method. One measuring system is developed at Electrical Engineering institute Nicola Tesla, Belgrade. Accordingly the advantage of simultaneous method applied at the primary metrology of current transformer is verified.
- Published
- 2018
46. The Recent Contribution to Calibration of Current Transformers Language of
- Author
-
Naumović, Vuković Dragana, Mitrović, Zoran, Sovilj, Platon, Kovačević, Dragan, Pejić, Dragan, and Antić, Boris
- Subjects
Current transformer, standard current transformer, current comparator, two stagecurrent transformer, measuring system, calibration, uncertainty of measurement,simultaneous method, intercompaison ,strujni transformator, etaloniranje,merna aparatura, merni sistem, jednovremenauporedna metoda etaloniranja, merna nesigurnost, interkomparacija,međulaboratorijsko poređenje - Abstract
U ovoj doktorskoj disertaciji prikazana je koncepcija, realizacija i potvrda nove metodejednovremenog etaloniranja strujnih mernih transformatora sa dve različite merneaparature. Pregledom stručne literature ne postoji podatak da je ova metoda ranijeprimenjivana. U disertaciji su prikazane različite merne metode za ispitivanje ietaloniranje mernih transformatora koje imaju primenu u savremenoj praksi i kojepodrazumevaju i različite merne mogućnosti. Takođe je i ekperimentalno potvrđenojednovremeno ispitivanje i etaloniranje strujnih mernih transformatora sa nekolikomernih aparatura koje su zasnovane na različitim metodama. Sprovedna istraživanja ieksperimentalni rezultati pokazuju i potvrđuju niz prednosti ovakvog načinaetaloniranja. Detaljna analiza komponenti merne nesigurnosti pokazala je da seprimenom ove metode postiže poboljšanje merne nesigurnost etaloniranja za skoro redveličine u odnosu na klasično pojedinačno etaloniranje sa dve različite merneaparature. Analiza uticajnih veličina na mernu nesigurnost pokazuje da se po ovoj novojmetodi etaloniranja eliminiše niz komponenti od kojih su najznačajnije: uticajnejednakosti referentnih struja i ispitnog opterećenja. Istraživanja su takođe pokazalada jednovremena metoda osim što doprinosi podizanju tačnosti etaloniranja strujnihtransformatora, ima primenu i u etaloniranju mernih aparatura za ispitivanje tačnostimernih transformatora i interkonparaciji strujnih etalon transformatora. Krozkonkretne primere realizovane u praksi, razmotreni su i prikazani načini etaloniranjamernih aparatura za ispitivanje tačnosti ovom novom metodom. Interkomparacijom dvamerna sistema visoke klase tačnosti Nacionalnog merološkog instituta Kanade(National Research Council Canada), od kojih je jedna razvijena u ElektrotehničkomInstitutu "Nikola Tesla", pokazana je i prednost primene jednovremene metode u oblastiprimarne metrologije strujnih mernih transformatora., The dissertation presents the concept, its realisation and verification of the new methodof simultaneous comparison of the current transformers by two different measuringapparatus. It is shown by searching the literature, that this method has not been usedbefore. In this dissertation different measuring methods for testing and calibration ofcurrent transformers, with their different measuring capabilities are presented. Most ofthem have been used in recent practice. Furthermore, the experimental verification ofnew simultaneous calibration method is presented. For this reason some measuringapparatus based on different measuring methods were used. Conducted research andexperimental results confirmed a number of advantages of this calibration method.Detailed analysis of the components of the uncertainty of measurements shown thatusing simultaneous method uncertainty of measurements have been improvedcomparing to method with two individual calibration by different apparatus. In that casesome of the measuring uncertainty components can be neglected. The most significantis component caused by variation of referent current and component caused by variationof burden. The research has also showed that simultaneous method can be used forcalibration of measuring apparatus for current transformer accuracy testing and theirinter-comparisons. The ways of calibration of apparatus for current transformer accuracytesting are considered and presented, through concrete examples realized in practice.A high-accuracy comparison of two NRC (National Research Council Canada)calibration systems were carried out by new simultaneous method. One measuringsystem is developed at Electrical Engineering institute Nicola Tesla, Belgrade.Accordingly the advantage of simultaneous method applied at the primary metrology ofcurrent transformer is verified.
- Published
- 2018
47. Merenje stabilnosti frekvencije u frekvencijskom domenu
- Author
-
Milanović, Ivica, Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, and Antić, Boris
- Subjects
noise ,Fazni šum, Lisonova jednačina, oscilator, etaloniranje, metoda, frekvencija,faza, šum, stabilnost, nestabilnost, vremenski domen, frekvencijski domen ,metoda ,vremenski domen ,фреквенција ,временски домен ,frequency domain ,шум ,стабилност ,еталонирање ,Leeson`s equation ,stabilnost ,oscilator ,Фазни шум, Лисонова једначина, осцилатор, еталонирање, метода, фреквенција,фаза, шум, стабилност, нестабилност, временски домен, фреквенцијски домен ,oscillator ,осцилатор ,phase ,фаза ,Лисонова једначина ,метода ,time domain ,Phase noise ,faza ,нестабилност ,фреквенцијски домен ,stability ,calibration ,Fazni šum ,Lisonova jednačina ,nestabilnost ,instability ,Фазни шум ,frekvencijski domen ,frequency ,method ,šum ,frekvencija ,etaloniranje ,Phase noise, Leeson`s equation, oscillator, calibration, method, frequency, phase,noise, stability, instability, time domain, frequency domain - Abstract
Дисертација истражује најприхватљивије методе мерења стабилности фреквенције уфреквенцијском домену, односно мерење вредности величине „фазни шум“, приликомпроцеса еталонирања мерне опреме. Када се говори о мерној опреми која је предмететалонирања, дисертација је, пре свега, окренута ка еталонирању врхунскихкомерцијалних стандарда (еталона) фреквенције. Приказана истраживања су била основза покретање и реализацију истраживачко-развојног пројекта у оквиру Министарстваодбране, који је имао за циљ оспособљавање метролошке лабораторије Техничкогопитног центра Војске Србије за потпуно еталонирање мерне опреме из областивремена и фреквенције. Различите методе мерења подразумевају и различите мернемогућности, као и врло широк спектар еталонске и мерне опреме која се користи прињиховој реализацији. У дисертацији се приказују различити начини мерења фазног шумаи описују методе реализоване на основу доступне мерне опреме. Како се ради ометодама упоредне анализе референтног и мереног сигнала, посебно критична позицијаје одабир референце, односно референтног еталона. Истраживање је довело дозакључака којима је предложен метод мерења потребне и довољне мерне несигурностикао и начин реализације изабране методе, односно одабир еталонске мерне опреме. Уциљу увођења мерне методе у употребу, извршена су и приказана мерења наразличитим типовима и врстама мерне опреме. Валидација методе је остваренабилатералним поређењем са Дирекцијом за мере и драгоцене метале, Група за време,фреквенцију и дистрибуцију времена. Да је могуће реализовати методу мерења фазногшума приликом еталонирања најквалитетнијих осцилатора је постављена хипотезадисертације, која је истраживањем доказана и практично спроведена. Крајњи резултатистраживања је довео до увођења признате методе еталонирања фазног шума, први пут, Disertacija istražuje najprihvatljivije metode merenja stabilnosti frekvencije ufrekvencijskom domenu, odnosno merenje vrednosti veličine „fazni šum“, prilikomprocesa etaloniranja merne opreme. Kada se govori o mernoj opremi koja je predmetetaloniranja, disertacija je, pre svega, okrenuta ka etaloniranju vrhunskihkomercijalnih standarda (etalona) frekvencije. Prikazana istraživanja su bila osnovza pokretanje i realizaciju istraživačko-razvojnog projekta u okviru Ministarstvaodbrane, koji je imao za cilj osposobljavanje metrološke laboratorije Tehničkogopitnog centra Vojske Srbije za potpuno etaloniranje merne opreme iz oblastivremena i frekvencije. Različite metode merenja podrazumevaju i različite mernemogućnosti, kao i vrlo širok spektar etalonske i merne opreme koja se koristi prinjihovoj realizaciji. U disertaciji se prikazuju različiti načini merenja faznog šumai opisuju metode realizovane na osnovu dostupne merne opreme. Kako se radi ometodama uporedne analize referentnog i merenog signala, posebno kritična pozicijaje odabir reference, odnosno referentnog etalona. Istraživanje je dovelo dozaključaka kojima je predložen metod merenja potrebne i dovoljne merne nesigurnostikao i način realizacije izabrane metode, odnosno odabir etalonske merne opreme. Ucilju uvođenja merne metode u upotrebu, izvršena su i prikazana merenja narazličitim tipovima i vrstama merne opreme. Validacija metode je ostvarenabilateralnim poređenjem sa Direkcijom za mere i dragocene metale, Grupa za vreme,frekvenciju i distribuciju vremena. Da je moguće realizovati metodu merenja faznogšuma prilikom etaloniranja najkvalitetnijih oscilatora je postavljena hipotezadisertacije, koja je istraživanjem dokazana i praktično sprovedena. Krajnji rezultatistraživanja je doveo do uvođenja priznate metode etaloniranja faznog šuma, prvi put, The dissertation examines the most acceptable methods for measuring the frequency stabilityin the frequency domain, that is, measuring the value of the "phase noise", during the processof measuring equipment calibration. When it comes to measuring equipment as a subject ofcalibration, the dissertation is, first of all, oriented towards the calibration of the highestcommercial frequency standards. The presented researches were the basis for initiation andrealization of the research and development project within the Ministry of Defense, which wasaimed at training the metrology laboratory of the Technical Test Center of the Serbian Armyfor complete calibration of measuring equipment in the area of time and frequency. Differentmeasurement methods also involve different measurement possibilities, as well as a very widerange of calibration and measuring equipment used in their realization. Different methods ofmeasuring phase noise are described in the dissertation and they describe realized methodsbased on available measuring equipment. As for methods of comparative analysis of thereference and measured signal, a particularly critical position is the selection of the reference,that is, the reference oscillator. The research led to conclusions suggesting the method ofmeasuring the necessary and sufficient measurement uncertainty, as well as the method ofrealization of the chosen method, i.e. selection of the standard measuring equipment. In orderto put the measurement method into practice, measurements were performed on differenttypes of measuring equipment. Validation of the method was achieved by bilateralcomparison with the Directorate of Measures and Precious Metals, Group for time, frequencyand time dissemination. The possibility to realize the method of phase noise measurementduring the calibration of the highest quality oscillators is a hypothesis of the dissertation thathas been set up, and has been proven and practically carried out by the research. The finalresult of the research led to the introduction of a recognized calibration method of the phasenoise, for the first time in the Republic of Serbia.
- Published
- 2018
48. Prilog optimizaciji performansi digitalnih merenja
- Author
-
Urekar, Marjan, Pejić, Dragan, Sovilj, Platon, Kovačević, Dragan, Mitrović, Zoran, and Jeličić, Zoran
- Subjects
stohastički merni instrument ,stohastička digitalna merna metoda ,stochastic measurement instrument ,stochastic digital measurement method, stochastic measurement instrument, stochastic flash A/D converter, dither, precision, measurement uncertainty ,preciznost ,stohastička digitalna merna metoda, stohastički merni instrument, stohastički fleš A/D konvertor, diter, preciznost, merna nesigurnost ,diter ,dither ,measurement uncertainty ,precision ,merna nesigurnost ,stochastic digital measurement method ,stohastički fleš A/D konvertor ,stochastic flash A/D converter - Abstract
U tezi se razmatra kriterijum optimalnosti stohastičkog fleš A/D konvertora (SFADC) koji predstavlja osnovu stohastičke digitalne metode merenja (SDMM). Razvijen je matematički i simulacioni model višebitnog SFADC i određen optimum broja bita rezolucije. Napravljen je hardverski prototip 4-bitnog stohastičkog mernog instrumenta (SMI), koji je ispitan brojnim eksperimentima i upoređen sa teorijski određenim vrednostima performansi merenja. Hipoteza ove teze – da postoji optimalni broj bita rezolucije SMI pri kome se ostvaruje maksimalna dobit u preciznosti merenja po ceni dupliranja potrebnog hardvera – potpuno je potvrđena., The thesis considers the criterion of optimality of the stochastic flash A/D converter (SFADC), which is the basis of the stochastic digital measurement method (SDMM). The mathematical and simulation model of the multibit SFADC was developed and the optimal number of bits of resolution was determined. A hardware prototype of a 4-bit stochastic measuring instrument (SMI) was made, tested in numerous experiments and compared with theoretically determined measurement performance values. The hypothesis of this thesis - that there is an optimal number of SMI resolution bits in which the maximum benefit of the measurement precision is achieved at the price of duplication of the required hardware - is fully confirmed
- Published
- 2018
49. Metoda merenja elektrookulografskog signala na intervalu sa preklapanjem vremenskih prozora
- Author
-
Đorđević-Kozarov, Jelena, Sovilj, Platon, Mitrović, Zoran, Radenković, Dragan, Lukač, Damir, and Pejić, Dragan
- Subjects
симулациони модел ,simulation model ,Modified digital stochastic measurement method ,Modified digital stochastic measurement method, electrooculography, simulation model, computer based instrument ,instrument baziran na računarskoj platformi ,computer based instrument ,електроокулографија ,elektrookulografija ,Modifikovana digitalna stohastička merna metoda ,Модификована дигитална стохастичка мерна метода ,electrooculography ,Модификована дигитална стохастичка мерна метода, електроокулографија, симулациони модел, инструмент базиран на рачунарској платформи ,Modifikovana digitalna stohastička merna metoda, elektrookulografija, simulacioni model, instrument baziran na računarskoj platformi ,инструмент базиран на рачунарској платформи ,simulacioni model - Abstract
У тези је предложена метода мерења ЕОГ сигнала на интервалу сапреклапањем временских прозора, која представља модификацијудигиталне стохастичке методе мерења (ДСММ). Хардвер којим сепредложена метода може имплементирати заснован је на рачунарскојплатформи и микроконтролерској структури. Метода је испитана бројнимсимулацијама и експериментима. Хипотеза ове тезе – да модел мерењаЕОГ сигнала на интервалу са преклапањем временских прозораомогућава пројектовање ЕОГ мерног уређаја који је отпорнији на утицајшума него ЕОГ мерни уређаји засновани на класичном дигиталноммерењу – потпуно је потврђена., U tezi je predložena metoda merenja EOG signala na intervalu sapreklapanjem vremenskih prozora, koja predstavlja modifikacijudigitalne stohastičke metode merenja (DSMM). Hardver kojim sepredložena metoda može implementirati zasnovan je na računarskojplatformi i mikrokontrolerskoj strukturi. Metoda je ispitana brojnimsimulacijama i eksperimentima. Hipoteza ove teze – da model merenjaEOG signala na intervalu sa preklapanjem vremenskih prozoraomogućava projektovanje EOG mernog uređaja koji je otporniji na uticajšuma nego EOG merni uređaji zasnovani na klasičnom digitalnommerenju – potpuno je potvrđena., EOG signal measurement method over an interval using overlapping timewindows, which represents the modification of the digital stochasticmeasurement method (DSMM), has been proposed in this thesis. Thehardware that can implement the proposed method is based on a computerplatform and a microcontroller structure. The method has been tested withnumerous simulations and experiments. Hypothesis of this thesis - the modelof EOG signal measurement over an interval using overlapping time windowsallows a design of EOG measuring device more resistant to the noise impactthan the EOG measuring devices based on classical digital measurement -has been fully confirmed.
- Published
- 2018
50. Izražavanje merne nesigurnosti kapacitivnih razdelnika napona sa koncentrisanim parametrima u oblasti visokih frekvencija
- Author
-
Kovačević, Uroš, Mitrović, Zoran, Sovilj, Platon, Denić, Dragan, Pejić, Dragan, and Antić, Boris
- Subjects
merenje brzih impulsnih napona ,Kerr electro-optic efect ,Kerov elektrooptički efekat ,measurement of fast pulsed voltageimpulse ,voltage dividers ,Expression of measurement uncertainty ,razdelnici napona ,Expression of measurement uncertainty, measurement of fast pulsed voltageimpulse, Kerr electro-optic efect, voltage dividers ,Izražavanje merne nesigurnosti ,Izražavanje merne nesigurnosti, merenje brzih impulsnih napona,Kerov elektrooptički efekat, razdelnici napona - Abstract
Ova disertacija sadrži analizu mogućnosti merenja brzih impulsnihnapona i izražavanja odgovarajuće merne nesigurnosti. Dokazano je daje moguće izvršiti numeričku simulaciju odziva mernog sistema naimpuls brzine porasta reda veličine pikosekunde. Izražena je mernanesigurnost kapacitivnog razdelnika napona Monte Karlo metodom.Prikazan je način konstruisanja kapacitivnog razdelnika napona satalasovodnim prilagodnim otporom. Konstruisano je više tipovakapacitivnih razdelnika napona izuzetno dobrih karakteristika. Naosnovu dobijenih rezultata je odabran kapacitivni razdelnik naponanajboljih karakteristika i izražena je njegova merna nesigurnost, This thesis contains an analysis of the possibilities for measurement of veryfast pulse voltages and proper expression of measurement uncertainty. It hasbeen proven that it is possible to perform numerical simulation to theresponse of the very fast pulse voltage with rise time at the order ofpicoseconds of the measuring system. Measurement uncertainty ofcapacitive voltage dividers is expressed by Monte Carlo method. The way ofconstructing capacitive voltage dividers with a waveguide resistance isshown in this thesis. The design of four types of capacitive voltage dividerswith extremely good features are shown. Based on these results, capacitivevoltage divider with best characteristics is selected and its measurementuncertainty is expressed.
- Published
- 2017
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.