498 results on '"PRÓTESES E IMPLANTES"'
Search Results
2. PLANEJAMENTO CIRÚRGICO POR MEIO DO FLUXO DIGITAL NA REABILITAÇÃO ORAL COM IMPLANTES OSSEOINTEGRÁVEIS - RELATO DE CASO CLÍNICO.
- Author
-
MIYAHIRA, ALEXANDRE, GRACIA NETO, EDSON, SOARES, WEVERTEON, CORREA MOMESSO, GUSTAVO ANTONIO, CASTRO PIMENTEL, ANGÉLICA, ROBERTO SENDYK, WILSON, and FONSECA MARÃO, HELOISA
- Abstract
The objective of this study is to present a clinical case of oral rehabilitation using digital workflow, encompassing the entire process from planning to treatment completion. The evolution of implantation techniques, incorporating intraorais scanners, tomographies, and digital planning software, has led to guided surgeries. These surgeries offer greater precision, reduced surgical time, and less discomfort for patients. The report describes surgical procedures performed on the maxilla and mandible. The use of surgical guides was crucial in guiding implant drilling, following a defined protocol of drills and guide sleeves. The fabrication of prostheses was based on intraoral scans, allowing for precise planning. The digital workflow provides a high level of predictability in the outcome of both surgical and prosthetic phases. Efficient and aesthetic outcomes, reduced surgical time, increased post-operative patient comfort, and shorter prosthetic fabrication time are distinct advantages of this technique. [ABSTRACT FROM AUTHOR]
- Published
- 2024
3. Ensino remoto emergencial realizado no projeto de extensão 'Restaurações Indiretas Dento e Implantossuportadas' durante a pandemia de COVID-19
- Author
-
Gabriela da Silva Chagas, Herbert Haueisen Sander, Walison Arthuso Vasconcellos, and Ricardo Rodrigues Vaz
- Subjects
ensino à distância ,isolamento social ,próteses e implantes ,educação a distância ,pandemia covid-19 ,Social Sciences ,Labor in politics. Political activity of the working class ,HD8031 - Abstract
Este trabalho relata atividades síncronas e assíncronas do Ensino Remoto Emergencial desenvolvidas no projeto de extensão “Restaurações Indiretas Dento e Implantossuportadas” utilizando a Plataforma Microsoft Teams. Esse projeto de extensão executa o tratamento clínico restaurador em dentes naturais e sobre implantes dentários em pacientes que buscam atendimento na Universidade Federal de Minas Gerais (UFMG). A prestação de serviço é realizada por alunos de graduação, monitores de pós-graduação e professores das áreas de Dentística e Prótese Dentária do Departamento de Odontologia Restauradora, que compreendem que o tratamento odontológico utilizando implantes dentários proporcionou aos indivíduos com ausência parcial ou total dos dentes o restabelecimento da saúde bucal, restaurando a função mastigatória e estética, oferecendo, assim, maior conforto e qualidade de vida. As atividades clínicas eram presenciais até 2019, entretanto, devido à pandemia de COVID-19, as atividades foram reestruturadas. Foram elaborados doze e-books com os temas relacionados à prótese, todos publicados na Câmara Brasileira do Livro. As atividades realizadas proporcionaram a divulgação de novas informações sobre saúde bucal para alunos e pacientes da Faculdade de Odontologia da UFMG, englobando o conceito da interação dialógica junto à sociedade.
- Published
- 2023
- Full Text
- View/download PDF
4. Prótese Nasal Para Uso Noturno
- Author
-
José Roberto Vidulich de Rezende
- Subjects
Próteses e Implantes ,Implantes Experimentais ,Face/anormalidades ,Nariz/cirurgia ,Neoplasms. Tumors. Oncology. Including cancer and carcinogens ,RC254-282 - Abstract
O Autor, neste trabalho, salienta os problemas inerentes à confecção de uma prótese facial, destacando aqueles referentes ao seu uso durante o período "noturno". Propõe método de confecção de prótese nasal de recobrimento em PVC resiliente, utilizando aparelho Omnivac IV, usado em prótese dental na construção de vários aparelhos. Após a descrição do método, conclui que este ofereceu uma série de vantagens. Os portadores destas próteses mostraram-se satisfeitos, e sob o ponto de vista do autor o único inconveniente é ser o material incolor.
- Published
- 2023
- Full Text
- View/download PDF
5. Comparação entre os resultados do implante de um segmento de arco longo versus dois segmentos de arco tradicional no tratamento de pacientes com ceratocone
- Author
-
Frederico Bicalho Dias da Silva, Nathalie Dalloul Daher, and Felipe Alves Botelho
- Subjects
Ceratocone ,Topografia da córnea ,Astigmatismo ,Refração ocular ,Próteses e implantes ,Ophthalmology ,RE1-994 - Abstract
RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.
- Published
- 2023
- Full Text
- View/download PDF
6. Associated short and regular implants for complete denture retention in an atrophic mandible: clinical follow-up.
- Author
-
da Silva Valente, Valdimar, Vilarinho Soares de Moura, Carmem Dolores, Leal de Moura, Walter, Lopes Mattos, Graça Maria, Materson da Silva, Antonio, Silva Costa, Cyrene Piazera, Pinheiro Neto, Sebastião Marinho, and de Jesus Tavarez, Rudys Rodolfo
- Subjects
- *
DENTAL implants , *DENTURES , *COMPLETE dentures , *EDENTULOUS mouth , *MENTAL foramen , *MANDIBLE , *BONE resorption , *DENTAL clinics - Abstract
Objective: to present the radiographic clinical follow-up of the prosthetic rehabilitation of a patient with an atrophic mandible, with the installation of short implants associated with an implant of regular length. Method: case report of a completely edentulous patient with an atrophic mandible and a 6-year radiographic clinical follow-up conducted at the dental clinic of the Federal University of Piauí, Teresina, from February 2011 to January 2020. After collecting sociodemographic data, health records, clinical radiographic examinations, and prosthetic surgical planning, four dental implants were installed between the mental foramina. After three months, mini-conical abutments and a fixed prosthesis screwed onto the implants were installed and monitored every six months for a period of six years. Results: the clinical evaluation revealed tissue stability without significant peri-implant changes after the follow-up period. Radiographically, bone resorption was not observed around the implant. Stability of the prosthesis and absence of prosthetic complications were observed during the follow-up period. Conclusion: short implants associated with regular-length implants can be placed in the anterior region of an atrophic mandible for rehabilitation with fixed complete dentures. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
7. Comparação entre os resultados do implante de um segmento de arco longo versus dois segmentos de arco tradicional no tratamento de pacientes com ceratocone.
- Author
-
Dias da Silva, Frederico Bicalho, Dalloul Daher, Nathalie, and Alves Botelho, Felipe
- Subjects
- *
ARC length , *VISUAL accommodation , *CORNEAL topography , *VISUAL acuity , *ASTIGMATISM , *CORNEA , *KERATOCONUS , *PROSTHETICS - Abstract
Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
8. Biofilme em parafusos ortopédicos prontos para uso adquiridos por meio de sistema de consiganação/comodato.
- Author
-
Pereira, Luiz Antônio, Lopes, Lillian Kelly de Oliveira, Costa, Dayane de Melo, Santos, Michelle Augusta dos, Boff, Isabella Marra de Queiroz, Leão-Vasconcelos, Lara Stefânia Netto de Oliveira, Vickery, Karen, and Tipple, Anaclara Ferreira Veiga
- Abstract
Copyright of Acta Paulista de Enfermagem is the property of Universidade Federal de Sao Paulo, Escola Paulista de Enfermagem and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
9. Biomechanics of implant-supported restorations.
- Author
-
de ANDRADE, Guilherme Schmitt, KALMAN, Les, LO GIUDICE, Roberto, ADOLFI, Dario, FEILZER, Albert J., and Mendes TRIBST, João Paulo
- Subjects
DENTAL implants ,DENTAL fillings ,BIOMECHANICS ,STRESS concentration ,PATIENT satisfaction - Abstract
Copyright of Brazilian Dental Science is the property of Brazilian Dental Science Journal-ICT-UNESP and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
10. Zircônia na odontologia: mini-revisão
- Author
-
Simone Kreve and Andréa Cândido dos Reis
- Subjects
cerâmica ,zircônio ,próteses e implantes ,Dentistry ,RK1-715 - Abstract
Objetivo: O objetivo deste estudo é fornecer ao cirurgião-dentista conhecimento sobre aspectos gerais da zircônia e abordar a introdução das diferentes gerações. Materiais e métodos: Foi realizada uma pesquisa eletrônica da literatura atual em inglês, incluindo artigos científicos publicados até 2019. Resultados: De acordo com os artigos selecionados, diferenças importantes foram encontradas em relação as novas composições da zircônia, sua microestrutura, diferenças no conteúdo da fase cúbica, e de ítria na fase tetragonal, levando a diferentes propriedades ópticas, mecânicas e de resistência ao envelhecimento. Conclusão: A zircônia é o material mais resistente disponível entre as cerâmicas, com diferenças mecânicas e ópticas entre os materiais disponíveis. A introdução das coroas monolíticas resolveu o problema de lascamento da porcelana de cobertura, mas foram necessárias modificações estruturais para fornecer adequada translucidez.
- Published
- 2021
- Full Text
- View/download PDF
11. Biomechanical behavior of implants with prosthetic connection of the morse (Cone) type, with different angulations at the implant-abutment interface in multiple dental prostheses: a finite element study.
- Author
-
SERPA, Michel Faivro Almeida, SOTTO-MAIOR, Bruno Salles, FRANCISCHONE, Carlos Eduardo, RIBEIRO, Mateus Antunes, and LIMA, Wellington
- Subjects
DENTURES ,STRESS concentration ,FINITE element method ,SHEARING force ,CONES ,COMPACT bone - Abstract
Copyright of RGO: Revista Gaúcha de Odontologia is the property of RGO: Revista Gaucha de Odontologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
12. Retention of cemented zirconia copings on TiBase abutments.
- Author
-
Santos-Neto, Oswaldo S., Gonçalves, Letícia M., Maia-Filho, Etevaldo M., Malheiros, Adriana S., Firoozmand, Leily M., Villis, Paulo C. M., Cardenas, Andres F. M., and Tavarez, Rudys R. J.
- Subjects
TWO-way analysis of variance ,TUKEY'S test ,ZIRCONIUM oxide ,TENSILE tests ,TENSILE strength - Abstract
Copyright of Acta Odontologica Latinoamericana: AOL is the property of Acta Odontologica Latinoamericana and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
13. Construct validity of the 2-minute walk test for patients with lower limb amputation using prosthesis.
- Author
-
Lavoura Balbi, Larissa, Zavatini Secco, Milena, Bregantin Pinheiro, Beatriz, Castro Pereira, Maira Stéfanie, Bavaresco Barros, Ana Regina, and de Cássia Registro Fonseca, Marisa
- Subjects
RESEARCH methodology evaluation ,FUNCTIONAL status ,CROSS-sectional method ,HEALTH surveys ,TERTIARY care ,MULTITRAIT multimethod techniques ,AMPUTEES ,QUESTIONNAIRES ,QUALITY of life ,DESCRIPTIVE statistics ,LEG amputation ,DATA analysis software - Abstract
Copyright of Fisioterapia e Pesquisa is the property of Universidade de Sao Paulo, Faculdade de Medicina and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
14. Utilização de membros protéticos fabricados a partir de impressão 3D para amputados
- Author
-
Thiago Domingues Stocco and Renan Alves Rodrigues
- Subjects
Amputação ,Próteses e Implantes ,Impressão Tridimensional ,Membros Artificiais ,Medicine ,Public aspects of medicine ,RA1-1270 - Abstract
Introdução: As próteses são definidas como dispositivos destinados a suprir a funcionalidade completa ou parcial de um membro ausente, de forma a prover independência ao indivíduo amputado, além de melhorar aspectos psicológicos e sociais. Portanto, a escolha da prótese adequada tem um papel fundamental no processo de reabilitação desses pacientes. Nesse contexto, a tecnologia de impressão tridimensional (3D) aplicada na área da saúde tem agregado novas possibilidades na fabricação de próteses. Objetivo: Analisar as evidências da utilização de próteses fabricadas utilizando a tecnologia de impressão 3D em amputados. Métodos: Trata-se de uma revisão de literatura de artigos científicos indexados nas bases de dados MEDLINE, SciELO e LILACS. A pesquisa foi realizada sem restrição de data ou idioma, com base na combinação das palavras-chave: amputação, próteses, impressão tridimensional e membros artificiais. Resultados: A análise foi desenvolvida utilizando 13 artigos que apresentaram como principais vantagens das próteses fabricadas em impressão 3D o baixo custo e menor tempo de fabricação, personalização, manutenção barata, próteses mais leves, modelos digitais de próteses disponíveis gratuitamente e possibilidade de agregar outros sistemas como polias e sistemas mioelétricos. As desvantagens incluem próteses com materiais menos duráveis, menos rígidos, com pouca estabilidade térmica, além de apresentarem baixa força de preensão manual e necessidade de mais profissionais qualificados para o processo de fabricação. Conclusão: As próteses desenvolvidas utilizando a tecnologia de impressão 3D melhoram a qualidade de vida em indivíduos com deficiência física, permitindo-os executar ações perdidas pela ausência do membro. Embora exista alguns obstáculos e desvantagens, a tecnologia de impressão 3D tem emergido como potencial ferramenta para construção de próteses personalizadas e mais acessíveis.
- Published
- 2020
- Full Text
- View/download PDF
15. Obturação protética palatina implantossuportada na reabilitação de sequela de carcinoma adenóide cístico: relato de caso
- Author
-
Paula Carolina de Souza Chandretti, Yuri de Lima Medeiros, Eduardo Machado Vilela, Gustavo Saggioro Oliveira, and João Paulo da Silva Sudré
- Subjects
Obturadores Palatinos ,Prótese Maxilofacial ,Próteses e Implantes ,Carcinoma Adenóide Cístico ,Reabilitação Bucal ,Medicine (General) ,R5-920 - Abstract
Introdução: O carcinoma adenoide cístico (CAC) é um tumor raro e apresenta alto potencial de metástase. Em situações na qual o tumor possui localização crítica, como no caso do palato, a remoção cirúrgica pode ser extremamente invasiva e mutilante, gerando sequelas que resultam em prejuízos funcionais e estéticos ao paciente. Objetivo: Relatar o caso clínico de confecção de prótese obturadora de palato implantossuportada para o tratamento de um paciente com comunicação buco-nasal decorrente da cirurgia de remoção de CAC. Relato de Caso: Paciente de 33 anos, sexo feminino, procurou atendimento odontológico 6 meses após a remoção cirúrgica de um CAC em região nasopalatal, para reabilitação de comunicação buco-nasal. Para correção desta comunicação, foi realizada a confecção de uma prótese obturadora imediata, implantossuportada, com o sistema Barra-Clip. Para isso, houve a instalação de implantes osseointegrados, convencional e zigomático, além de confecção de uma barra de metal para fixação da prótese. Com a prótese palatina confeccionada, realizou-se a captura de dois Clips com resina acrílica autopolimerizável. Após a confecção e instalação da prótese, a paciente foi acompanhada mensalmente durante seis meses. Conclusão: As próteses bucomaxilofaciais são eficazes na reabilitação das sequelas advindas do tratamento cirúrgico em pacientes oncológicos. A utilização de implantes osseointegrados e sistema Barra-Clip se mostram como boas alternativas para a confecção de pilares de sustentação desses dispositivos, conferindo estabilidade e retenção.
- Published
- 2020
- Full Text
- View/download PDF
16. Quality of Life of Children with Otitis Media and Impact of Insertion of Transtympanic Ventilation Tubes in a Portuguese Population
- Author
-
Ana Rita Lameiras, Deodato Silva, Assunção O´Neill, and Pedro Escada
- Subjects
Criança ,Inquéritos e Questionários ,Otite Média/cirurgia ,Portugal ,Próteses e Implantes ,Qualidade de Vida ,Medicine ,Medicine (General) ,R5-920 - Abstract
Introduction: Quality of life is an important measure for health-outcome evaluation. Although otitis media is one of the most common childhood diseases, its impact on Portuguese children’s quality of life is unknown. The aim of this study is to determine the quality of life of Portuguese children with chronic otitis media with effusion and/or recurrent acute otitis media and the short-term impact of transtympanic ventilation tubes, using the Portuguese version of the OM-6 questionnaire, a valid, reliable and sensitive instrument to evaluate the health-related quality of life in children with otitis media. Material and Methods: This study was conducted in a tertiary referral center, to where children are referred from primary care and hospital pediatric consultations. The Portuguese version of the OM-6 questionnaire was applied to children with chronic otitis media with effusion and/or recurrent acute otitis media. The instrument was re-administered at two months postoperatively to a group of children who underwent tympanostomy tube placement, to evaluate the change in quality of life with the surgical procedure. Results: The study involved a sample of 169 children, aged between 6 months and 12 years (mean: 4.20 ± 2.05 years). The average score in the survey was 3.3 ± 1.47, of a maximum of 7 (worst quality of life). The domains ‘caregiver concerns’, ‘hearing loss’ and ‘physical suffering’ had the highest scores. The domain ‘hearing loss’ was correlated with the domain ‘speech impairment’ (rs = 0.41; p < 0.001) and the domain ‘physical suffering’ correlated with the domain ‘activity limitation’ (rs = 0.47; p < 0.001). There was a correlation between the score on ‘hearing loss’ and the presence of conduction hearing loss (χ2 (6) = 24.662; p = 0.022). Children with chronic otitis media with effusion had lower scores on the domain ‘physical suffering’, while children with recurrent acute otitis media had lower scores in the domain ‘hearing loss’ and higher scores in the domain ‘emotional distress’. There was an improvement in the quality of life in all the dimensions studied by the questionnaire after surgery. The improvement was large in 55%, moderate in 15% and small in 10% of the cases. The presence of otorrhea postoperatively did not decrease the quality of life improvement achieved with surgery. Conclusion: Otitis media has a negative impact on Portuguese children quality of life. Tympanostomy tubes improve quality of life related to the middle ear in most children. The application of validated disease-specific questionnaires allows an enhanced understanding of the impact of otitis media on Portuguese children quality of life and of the success of therapeutic measures.
- Published
- 2018
- Full Text
- View/download PDF
17. DOES LIDOCAINE HAVE ANTIMICROBIAL EFFECTS AGAINST MAJOR PATHOGENS THAT INFECT WOUNDS? AN IN VITRO STUDY.
- Author
-
Carvalho Henriques, Bruno, Delfino Caldeira, Isadora, Schadeck Portelinha, Maria Júlia, Lopes Medina, Denis Aloísio, Talavera Martelli, Cesar Alberto, Cayres de Oliveira, Mayla Silva, de Carvalho Almeida, Mércia, Alencar Marques, Mariângela Esther, and Alborghetti Nai, Gisele
- Subjects
- *
DISC diffusion tests (Microbiology) , *LIDOCAINE , *LOCAL anesthetics , *ENTEROCOCCUS faecalis , *STAPHYLOCOCCUS epidermidis , *ENTEROCOCCUS - Abstract
Local anesthetics are commonly used in medicine and dentistry and have a low cost, but their action as a microbicidal agent is still controversial. This study aimed to evaluate the antimicrobial effects of lidocaine against bacteria that most commonly infect surgical wounds. We evaluated Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Proteus mirabilis and Enterococcus faecalis. The solutions tested were saline, chlorhexidine, lidocaine (solution and pure) and an antibiotic solution. The agar diffusion test was performed using Petri dishes. The agar plates were made in duplicate and incubated in an oven at 37°C for 48 h. Subsequently, the inhibition halos were measured. The plates tested with lidocaine (pure or solution) presented no inhibition halo. The antibiotic solution presented the largest inhibition halos for all the bacteria (p<0.05). Chlorhexidine formed an inhibition halo similar to that of the antibiotic solution for Escherichia coli (p>0.05). Lidocaine did not present an antimicrobial effect for any of the tested bacteria. However, the antibiotic solution and the chlorhexidine inhibited the growth of all bacteria. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
18. Prosthesis-socket volume imbalance and dermofat graft rehabilitation in patients with an anophthalmic socket.
- Author
-
Sendul, Selam Yekta, Dirim, Burcu, Atılgan, Cemile Ucgul, Demir, Mehmet, Demir, Semra Tiryaki, Olgun, Ali, Uzun, Saniye Uke, Karapapak, Murat, and Guven, Dilek
- Subjects
MEDICAL records ,BLEPHAROPLASTY ,REHABILITATION ,PROSTHETICS ,OPHTHALMOLOGISTS ,EYELIDS - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
19. Implant- and tooth-supported removable partial dentures: a case report.
- Author
-
de Oliveira MELO, Jéssyca Maria França and de Farias BARBOSA, Eduardo
- Subjects
REMOVABLE partial dentures ,DENTAL arch ,INCISORS ,DENTAL implants ,DENTURES - Abstract
Copyright of RGO: Revista Gaúcha de Odontologia is the property of RGO: Revista Gaucha de Odontologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
20. Post-mammoplasty symmastia augmentation with silicone implants: treatment with quilting sutures
- Author
-
PAVELECINI, MICHEL, FASOLIN, FELIPE BILHAR, ZANIN, EDUARDO MADALOSSO, GASPERIN, BRUNO DELLA MEA, FREITAS NETO, FLÁVIO MACIEL DE, POSSAMAI, LEONARDO MILANESI, WEBSTER, RONALDO SCHOLZE, and ELY, PEDRO BINS
- Subjects
Implantes de mama ,Mamoplastia ,Prostheses and implants ,Mama ,Mammary diseases ,Breast ,Próteses e implantes ,Mammoplasty ,Doenças mamárias ,Breast implants - Abstract
RESUMO Introdução: A mamoplastia de aumento é o procedimento cirúrgico estético mais realizado nos EUA e o segundo no Brasil. Simastia é uma de suas possíveis complicações. Esta é definida como o mal posicionamento medial dos implantes mamários, que cruzam a linha média, com perda do sulco intermamário. Métodos: Trabalho tipo série de casos. Duas pacientes foram submetidas à correção de simastia pósmamoplastia de aumento. A via de acesso utilizada foi a incisão inframamária prévia. A correção do sulco intermamário foi realizada por escarificação das superfícies anterior e posterior da cápsula, associada a pontos de adesão com fio monofilamentar não absorvível (4 linhas com 6 pontos cada, compreendendo uma faixa vertical de aproximadamente 4 cm de largura na região pré-esternal). Em um dos casos o implante foi recolocado imediatamente e, no outro, em procedimento realizado 3 meses após. Resultados: Obtivemos um novo sulco intermamário satisfatório, com adequado resultado estético em ambos os casos. Não se observou recorrência após 9 e 11 meses de observação. Conclusões: A abordagem com suturas de adesão para a redefinição do sulco intermamário foi efetiva para o tratamento da simastia pós-mamoplastia de aumento. ABSTRACT Introduction: Augmentation mammoplasty is the most commonly performed esthetic surgical procedure in the United States and second in Brazil. Symmastia is one of its possible complications. This is defined as incorrect medial positioning of the breast implants, which cross the midline, losing the intermammary sulcus. Methods: Work type, series of cases. Two patients underwent symmastia repair after breast augmentation. The access route used was the previous inframammary incision. The repair of the intermammary sulcus was performed by scarification of the anterior and posterior capsule surfaces, associated with adhesion suture with non-absorbable monofilament threat (4 lines with 6 points each, comprising a vertical band of approximately 4 cm wide in the presternal region). In one of the cases, the implant was immediately replaced, and in the other, the procedure was done 3 months later. Results: In both cases, we obtained a new satisfactory intermammary sulcus, with proper esthetic result. No recurrence was observed on follow-ups at 9 and 11 months. Conclusions: The approach with adhesion sutures to redefine the intermammary sulcus was effective in the treatment of symmastia after breast augmentation.
- Published
- 2023
21. Histological comparison between irradiated and non-irradiated breasts in breast reconstruction
- Author
-
BENEDIK, ALBERTO, DIAS, RONAN CAPUTI SILVA, CAMPOS, AMANDA COSTA, CASTRO, CAROLINA OLIVEIRA PARANAGUA, CAMMAROTA, MARCELA CAETANO, and DAHER, JOSÉ CARLOS
- Subjects
Radioterapia ,Radiotherapy ,Prostheses and implants ,Mama ,Neoplasias da mama ,Breast ,Adjuvant radiotherapy ,Próteses e implantes ,Breast neoplasms ,Radioterapia adjuvante - Abstract
RESUMO Introdução: O tratamento do câncer de mama inclui, além de terapias curativas, a reconstrução mamária. Entre as estratégias adjuvantes, a radioterapia fornece desfechos favoráveis em termos de redução da taxa de recorrência da doença. Esse estudo tem como objetivo comparar as diferenças histológicas entre mamas irradiadas e não irradiadas em um mesmo paciente. Métodos: Estudo prospectivo de coorte em pacientes submetidos à reconstrução mamária com prótese ou expansor sob retalho muscular de peitoral maior, comparando os padrões histológicos de pele, tecido celular subcutâneo, músculo peitoral maior e cápsula do implante, de mamas irradiadas e não irradiadas em amostras pareadas de um mesmo paciente. Todos os pacientes deveriam receber irradiação em apenas uma das mamas. A análise anatomopatológica foi comparada aos achados clínicos e aos aspectos macroscópicos do transoperatório. Resultados: O trabalho contou com um total de 7 pacientes, sendo a idade média de 52,15 anos. Os principais achados histológicos em pele e tecido celular subcutâneo da mama irradiada foram: hiperplasia epidérmica, achatamento da camada papilar, atrofia dos apêndices dérmicos, congestão vascular no tecido gorduroso, alta densidade das fibras de colágeno dérmico, hialinização das paredes vasculares, redução das fibras elásticas na derme profunda e alinhamento unidirecional das fibras de colágeno. Os principais achados histológicos de cápsula e músculo peitoral maior na mama irradiada foram: menor densidade de fibras elásticas, fibrose perivascular, metaplasia sinovial, sequestro de músculo esquelético na interface com a cápsula, hialinização capsular e fibroesclerose capsular. Conclusão: Encontramos alterações histológicas comuns nas mamas irradiadas em boa parte das pacientes, achados esses que são compatíveis com as alterações clínicas e macroscópicas observadas. Esse estudo apresenta-se como um piloto para o desenvolvimento de novos estudos que pesquisem os mecanismos fisiopatológicos relacionados às alterações histológicas descritas. ABSTRACT Introduction: The treatment of breast cancer includes not only curative therapies but also breast reconstruction. Radiotherapy, an adjuvant strategy, provides favorable outcomes by reducing the rate of recurrence of the disease. This study aimed to compare histological differences between irradiated and non-irradiated breasts in the same patient. Methods: This is a prospective cohort study of patients undergoing breast reconstruction with prosthesis or expander under pectoralis major muscle flap that compared histological skin patterns, subcutaneous cell tissue, pectoralis major muscle, and implant capsule of irradiated and non-irradiated breasts in paired samples of the same patient. All patients included in this study were irradiated in only one breast. The results of the anatomopathological analysis were compared to clinical findings and intraoperative macroscopic aspects. Results: The study included a total of 7 patients with a mean age of 52.15 years. The main histological findings in the skin and subcutaneous cellular tissue of the irradiated breast were as follows: epidermal hyperplasia, flattening of the papillary layer, atrophy of the skin appendages, vascular congestion in fatty tissue, high density of skin collagen fibers, hyalinization, and reduction of elastic fibers in the deep dermis and unidirectional alignment of collagen fibers. The main histological findings for the capsule and pectoralis major muscle in the irradiated breast were as follows: lower density of elastic fibrosis, perivascular fibrosis, synovial metaplasia, skeletal muscle sequestration at the interface with the capsule, capsular hyalinization, and capsular fribrosclerosis. Conclusion: We found common histological changes in irradiated breasts in most patients. These findings are compatible with the clinical and macroscopic changes observed. This study presents itself as a pilot for the development of further studies investigating the physiopathological mechanisms of the described histological changes.
- Published
- 2023
22. Immediate bilateral breast reconstruction after skin-sparing mastectomy: cross-sectional incision and implants in mixed plane
- Author
-
ANTONIO ROBERTO BOZOLA, ALEXANDRE CARONI BOZOLA, and ITALO BOZOLA FILHO
- Subjects
Mamoplastia ,Prostheses and implants ,Reconstructive surgical procedures ,Mammaplasty ,Mama ,Surgery ,Breast Neoplasms ,Neoplasias da mama ,Procedimentos cirúrgicos reconstrutivos ,Breast ,Próteses e implantes - Abstract
RESUMO Introdução: Complicações nas reconstruções imediatas de mamas pós-mastectomias preservadoras de pele são recorrentes. Os autores descrevem conduta para redução delas e melhoria do resultado anatômico/estético utilizando implantes. O objetivo é reduzir a incidência de necroses areolares, melhorar a projeção das mamas nas reconstruções com implantes submusculares, recuperar a sensibilidade parcial ou total e facilitar a simetrização. Método: A mastectomia é realizada com incisão transversal lateral, do bordo areolar à axila. A reparação com implantes incluídos em plano misto por divulsão do músculo peitoral, dividindo-o em duas porções na direção de suas fibras, associação da fáscia do músculo serrátil e tecido celular subcutâneo inferior/lateral, e/ou músculo peitoral menor na área superolateral. A incisão é suturada quando não há ptose mamária, ou superposta por desepidermização de um dos bordos, podendo incluir redução do diâmetro e relocação da aréola. Ou desepidermização fusiforme da pele periareolar e medialmente a ela. A mastectomia contralateral redutora de riscos teve procedimento semelhante, melhorando a simetria. Resultados: Foram operadas 106 pacientes (212 mamas) com resultados satisfatórios e complicações por infecção, posicionamento dos implantes na curva de aprendizado, e irregularidades de superfície. Conclusão: Reconstrução imediata das mamas pós-mastectomia preservadora de pele pelo método proposto é opção possível, obtendo boa simetrização e projeção das mamas, retorno da sensibilidade e ausência de necrose total de aréola. ABSTRACT Introduction: Complications in immediate breast reconstruction after skin-preserving mastectomies are recurrent. The authors describe conduct to reduce them and improve the anatomical/esthetic result using implants. The objective is to reduce the incidence of areolar necrosis, improve breast projection in reconstructions with submuscular implants, recover partial or total sensitivity, and facilitate symmetrization. Method: The mastectomy involves a lateral transverse incision from the areolar border to the armpit. Repair with implants included in a mixed plane by divulsion of the pectoral muscle, dividing it into two portions in the direction of its fibers, the association of the serratus muscle fascia and inferior/lateral subcutaneous tissue, and/or pectoralis minor muscle in the superolateral area. The incision is sutured when there is no breast ptosis or superimposed by de-epidermization of one of the borders, which may include a reduction in diameter and relocation of the areola. Or fusiform de-epidermization of the periareolar skin and medially to it. The contralateral risk-reducing mastectomy had a similar procedure, improving symmetry. Results: 106 patients (212 breasts) were operated on with satisfactory results and complications due to infection, positioning of the implants on the learning curve, and surface irregularities. Conclusion: Immediate breast reconstruction after skin-preserving mastectomy by the proposed method is a possible option, obtaining good breast symmetrization and projection, return of sensitivity, and absence of total necrosis of the areola.
- Published
- 2023
23. Remodelamento corneano: relato de um experimento com um vitrigel a base de colágeno tipo I para remodelamento de córneas porcinas
- Author
-
Marquezan, Maria Carolina, Freitas, Denise de, Majumdar, Shoumyo, Wang, Xiaokun, Elisseeff, Jennifer, Guyton, David L., Bower, Kraig Scot, Skurski, Zachary P., Chalita, Maria Regina, Belfort Jr, Rubens, and Jun, Albert S.
- Subjects
Corneal stroma ,Swine ,Corneal surgery ,Proteses e implantes ,Animais ,Suínos ,Substância própria ,Materiais bio-compatíveis ,laser ,Cornea ,Córnea ,Prostheses and implants ,Lasers de excimer ,Animals ,Corneal topography ,Biocompatible materials ,Lasers excimer ,Cirurgia da córnea a laser - Abstract
Purpose: This study aimed to report an experiment designed to determine anatomical changes in porcine corneas following placement of a novel polymer implant into the cornea. Methods: An ex vivo porcine eye model was used. A novel type I collagen-based vitrigel implant (6 mm in diameter) was shaped with an excimer laser on the posterior surface to create three planoconcave shapes. Implants were inserted into a manually dissected stromal pocket at a depth of approximately 200 μm. Three treatment groups were defined: group A (n=3), maximal ablation depth 70 μm; Group B (n=3), maximal ablation depth 64 μm; and group C (n=3), maximal ablation depth 104 μm, with a central hole. A control group (D, n=3) was included, in which a stromal pocket was created but biomaterial was not inserted. Eyes were evaluated by optical coherence tomography (OCT) and corneal tomography. Results: Corneal tomography showed a trend for a decreased mean keratometry in all four groups. Optical coherence tomography showed corneas with implants placed within the anterior stroma and visible flattening, whereas the corneas in the control group did not qualitatively change shape. Conclusions: The novel planoconcave biomaterial implant described herein could reshape the cornea in an ex vivo model, resulting in the flattening of the cornea. Further studies are needed using in vivo animal models to confirm such findings. RESUMO Objetivo: Relatar um experimento projetado para determinar alterações anatômicas em córneas porcinas após a colocação de um novo implante de polímero na córnea. Métodos: Foi utilizado olho de porco ex vivo. Um novo agente modelador biocompatível, de colágeno tipo 1, com 6mm de diâmetro foi moldado com excimer laser em sua face posterior, para criar três formatos planocôncavos. Os implantes foram inseridos dentro de um bolsão, dissecado manualmente, a 200 micrômetros (μm). Foram definidos três grupos de tratamento: grupo A (n=3), teve a profundidade máxima de ablação de 70 μm; o grupo B (n=3), profundidade máxima de ablação de 64 μm; e o grupo C (n=3), profundidade máxima de ablação de 104 μm, com buraco central. O grupo controle, D (n=3), foi incluído, com a criação do bolsão estromal, porém sem inserir o material. A avaliação desses olhos foi realizada por tomografia de coerência óptica (OCT) e por tomografia corneana. Resultados: A tomografia corneana mostrou uma tendência para diminuição da ceratometria média em todos os 4 grupos. A tomografia de coerência óptica mostrou córneas com implantes localizados no estroma anterior e aplanamento visível, enquanto as córneas não mudaram qualitativamente o formato no grupo controle. Conclusões: O novo implante de biomaterial planocôncavo descrito aqui foi capaz de remodelar a córnea em modelo de animal ex vivo, resultando no aplanamento corneano. Novos estudos são necessários usando modelos animais in vivo para confirmar tais achados.
- Published
- 2023
24. Endoprótese de tíbia proximal - protocolo de reabilitação.
- Author
-
de Brito Quessada, Ana Elisa, Aparecida Brumate Ramos, Katerine, dos Santos Alves, Vera Lúcia, Sadao Yonamine, Eduardo, and Cardoso Martinez, Emília
- Subjects
TIBIA surgery ,ARTIFICIAL limbs ,LIMB salvage ,MEDICAL protocols ,ORTHOPEDIC surgery ,OSTEOSARCOMA ,PHYSICAL therapy ,QUALITY of life ,SURVIVAL ,SYSTEMATIC reviews ,REHABILITATION - Abstract
Copyright of Fisioterapia Brasil is the property of Atlantica Editora and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
25. Pelvic migration of the helical blade after treatment of transtrochanteric fracture using a proximal femoral nail
- Author
-
Pedro Luciano Teixeira Gomes, Luís Sá Castelo, António Lemos Lopes, Marta Maio, Adélia Miranda, and António Marques Dias
- Subjects
Fraturas do fêmur ,Próteses e implantes ,Pinos ortopédicos ,Idoso ,Medicine ,Orthopedic surgery ,RD701-811 - Abstract
ABSTRACT Proximal femoral nails with a helical blade are a new generation of implants used for treating transtrochanteric fractures. The blade design provides rotational and angular stability for the fracture. Despite greater biomechanical resistance, they sometimes present complications. In the literature, there are some reports of cases of perforation of the femoral head caused by helical blades. Here, a clinical case of medial migration of the helical blade through the femoral head and acetabulum into the pelvic cavity is presented.
- Published
- 2016
- Full Text
- View/download PDF
26. Nanoskin: uso para reposição de volume na cavidade anoftálmica
- Author
-
Natalia Mussi, Maria Julia de Barros Orsolini, Claudia Helena Pellizon, Carla Adriene da Silva, Silvana Artioli Schellini, Gabriel Molina de Olyveira, and Pierre Basmaji
- Subjects
Anoftalmia/terapia ,Materiais biocompatíveis ,Celulose/metabolismo ,Próteses e implantes ,Enucleação ocular ,Evisceração do olho ,Coelhos ,Ophthalmology ,RE1-994 - Abstract
RESUMO Objetivo: Avaliar a biocompatibilidade da Nanoskin para reposição de volume em cavidades enucleadas ou evisceradas de coelhos. Métodos: Estudo experimental, utilizando implantes de Nanoskin (Innovatecs®, São Carlos, Brasil), celulose bacteriana produzida pela bactéria Acetobacter xylinum tendo como substrato o chá-verde. Implantes de 10mm de diâmetro/5mm de espessura foram colocados em cavidades enucleadas (G1) ou evisceradas (G2) de 21 coelhos, avaliados clinicamente todos os dias, sacrificados aos 7, 30 e 90 dias após a cirurgia. O material foi removido e preparado para exame de microscopia óptica. Resultados: Sinais flogísticos discretos no pósoperatório imediato, não tendo sido evidenciados sinais infecciosos ou extrusão de nenhum implante. Houve aparente redução do volume ao longo do período experimental. Histologicamente ambos os grupos foram muito semelhantes, apresentando aos 7 dias células inflamatórias (predominantemente monócitos e neutrófilos), rede de fibrina e hemácias. A Nanoskin apresentava-se como pequenas esferas, de cor rósea, com pequenos espaços entre elas, permeados por escassas células inflamatórias. As células inflamatórias se modificaram ao longo de período experimental, sendo possível observar aos 30 dias células gigantes multinucleadas e fibroblastos maduros permeando o implante. Aos 90 dias, a estrutura do implante apresentava-se desorganizada, amorfa, com restos necróticos e com áreas ovoides, revestidas por fina membrana rósea, que pareciam se agrupar, vazias ou preenchidas por material acelular, róseo ou acinzentado. Conclusão: A Nanoskin provocou reação inflamatória que levou à reabsorção e redução do volume do implante. Novas formulações devem ser estudadas a fim de ter um produto que seja permanente para reparo da cavidade anoftálmica.
- Published
- 2016
- Full Text
- View/download PDF
27. Biofilme em parafusos ortopédicos prontos para uso adquiridos por meio de sistema de consiganação/comodato
- Author
-
Luiz Antônio Pereira, Lillian Kelly de Oliveira Lopes, Dayane de Melo Costa, Michelle Augusta dos Santos, Isabella Marra de Queiroz Boff, Lara Stefânia Netto de Oliveira Leão-Vasconcelos, Karen Vickery, and Anaclara Ferreira Veiga Tipple
- Subjects
Advanced and Specialized Nursing ,Anti-infecciosos ,Procedimientos ortopédicos ,Bacteria ,Parafusos ósseos ,Sterilization ,Orthopedic procedures ,Procedimentos ortopédicos ,Prótesis e implantes ,Esterilização ,Medical–Surgical Nursing ,Esterilización ,Biopelículas ,Prostheses and implants ,Biofilms ,Anti-infective agents ,Tornillos óseos ,Próteses e implantes ,Antiinfecciosos ,Bacterias ,Bone screws ,Biofilmes - Abstract
Resumo Objetivo Avaliar a integridade da superfície e as condições microbiológicas de parafusos prontos para uso em bandejas ortopédicas após múltiplos processamentos. Métodos Após o processamento completo, as bandejas utilizadas em cirurgias de pequenos fragmentos, fornecidas por meio de sistema de consignação/comodato em um hospital brasileiro, foram selecionadas aleatoriamente durante quatro meses. Os parafusos mais utilizados (números 14, 16 e 18 – Grupo 1) e menos utilizados (números 10 e 38 – Grupo 2), portanto, os mais e menos expostos a agentes biológicos, químicos e físicos, foram aleatoriamente removidos e submetidos a inspeção visual (n=126), seguido de cultura bacteriana (n=6 parafusos/bandeja, 9 bandejas), teste de proteínas (n=6 parafusos/bandeja, 9 bandejas) e Microscopia Eletrônica de Varredura (MEV) (n=2 parafusos/bandeja, 9 bandejas). As culturas positivas foram submetidas a métodos automatizados de identificação bacteriana e suscetibilidade antimicrobiana. Resultados Foram detectadas ranhuras em 8,7% dos parafusos, predominantemente no Grupo 2 (8/11). Proteína residual foi detectada em 96,3%, e não houve diferença estatisticamente significativa na quantidade de proteína entre os grupos (P=0,07). Crescimento bacteriano foi identificado em 3/54 parafusos. Danos na superfície e presença de sujidade foram visualizados em todos os parafusos submetidos a MEV. Formação de biofilmes extensos foi detectada em oito parafusos, três do Grupo 1 e cinco do Grupo 2. Conclusão Recuperação de bactérias viáveis, acúmulo de biofilme e danos na superfície foram detectados nos parafusos prontos para uso. Os parafusos costumam permanecer nas bandejas cirúrgicas e serem submetidos a múltiplos processamento, sendo expostos a contaminação e danos repetidas vezes. Esses achados apontam para a necessidade de discutir e repensar a forma como esses implantes de uso único são atualmente disponibilizados para cirurgias. Resumen Objetivo Evaluar la integridad de la superficie y las condiciones microbiológicas de tornillos listos para uso en bandejas ortopédicas después de múltiples procesamientos. Métodos Después del procesamiento completo, fueron seleccionadas aleatoriamente durante cuatro meses las bandejas utilizadas en cirugías de pequeños fragmentos, proporcionadas mediante el sistema de consignación/comodato en un hospital brasileño. Los tornillos más utilizados (números 14, 16 y 18 – Grupo 1) y menos utilizados (números 10 y 38 – Grupo 2), por lo tanto, los más y menos expuestos a agentes biológicos, químicos y físicos, fueron quitados aleatoriamente y sometidos a inspección visual (n=126), seguido de cultivo bacteriano (n=6 tornillos/bandeja, 9 bandejas), prueba de proteínas (n=6 tornillos/bandeja, 9 bandejas) y microscopía electrónica de barrido (MEB) (n=2 tornillos/bandeja, 9 bandejas). Los cultivos positivos fueron sometidos a métodos automatizados de identificación bacteriana y susceptibilidad antimicrobiana. Resultados Se detectaron ranuras en el 8,7 % de los tornillos, predominantemente en el Grupo 2 (8/11). Se detectó proteína residual en el 96,3 % y no se encontró diferencia estadísticamente significativa en la cantidad de proteína entre los grupos (P=0,07). En 3/54 tornillos se identificó crecimiento bacteriano. Se visualizaron daños en la superficie y presencia de suciedad en todos los tornillos sometidos a MEB. En ocho tornillos se detectó la formación de biopelículas, tres del Grupo 1 y cinco del Grupo 2. Conclusión Se detectó recuperación de bacterias viables, acumulación de biopelícula y daños en la superficie en los tornillos listos para uso. Los tornillos suelen permanecer en las bandejas quirúrgicas y son sometidos a múltiples procesamientos, donde están expuestos a contaminación y daños repetidas veces. Estos descubrimientos señalan la necesidad de discutir y repensar la forma como estos implantes de uso único se ponen a disposición para cirugía actualmente. Abstract Objective Assess the surface integrity and microbiological conditions of patient-ready screws in orthopaedic trays that had been multiply reprocessed. Methods After full reprocessing, clinical trays used for small fragment surgery provided through a loaner system to a Brazilian hospital were randomly selected during four months. The most (numbers 14, 16 and 18 – Group 1) and least (numbers 10 and 38 – Group 2) frequently implanted screws, therefore, the ones estimated to be the most and least exposed to biological, chemical and physical agents, were randomly removed and subjected to visual inspection (n=126), followed by bacterial culture (n=6 screws/tray, 9 trays), protein test (n=6 screws/tray, 9 trays) and Scanning Electron Microscopy (SEM) (n=2 screws/tray, 9 trays). Positive cultures were subjected to automated bacterial identification and antimicrobial susceptibility tests. Results Grooves were detected on 8.7% screws, predominantly in Group 2 (8/11). Residual protein was detected on 96,3%, and there was no statistically significant difference in the amount of protein between the groups (P=0.07). Bacterial growth was identified in 3/54 screws. Surface damage and soil were visualized on all screws subjected to SEM. Extensive biofilms were detected on eight screws, three from Group 1 and five from Group 2. Conclusion Recovery of bacteria, biofilm accumulation and surface damage were detected on patient-ready screws. Screws frequently remain in surgical trays for multiple reprocessing; thus they are repeatedly exposed to contamination and damage. These findings point to the need to discuss and review the way these single-use implants are currently made available for surgeries.
- Published
- 2023
28. O avanço das confecções de facetas laminadas no uso odontológico / The advancement of laminate veneer fabrications in dentistry
- Author
-
Malta, Ermeson Allisson de Morais, Lima, Zenira Guiomar de, Santos, Victor Raphael, Santos, Islyane de Albuquerque, Ramalho, Natália Cristiane de Souza, Amorim, Marvellany Vieira de Melo, Hilário, Juniélyson Souza, and Mendonça, Izabel Cristina Gomes de
- Subjects
restaurações intracoronárias ,Porcelana dentária ,próteses e implantes ,General Medicine - Abstract
A odontologia vem passando por um processo de evolução ao que se refere aos materiais. Desde o século XVIII, existiam confecções de elementos dentais feitos à base de porcelana, juntamente com outro constituinte que era o marfim. As primeiras coroas inlays de cerâmicas feldspáticas fundidas foram introduzidas na odontologia por Land em 1886, sendo esse um material muito utilizado em restaurações indiretas. Em meados do final do século XIV, teve o surgimento de novas formas de manuseio da cerâmica a partir da inovação com o forno elétrico, com confecção de coroas totalmente cerâmicas sobre lâmina de platina. Os estudos e os avanços sobre as confecções de facetas laminadas nos últimos anos tiveram um crescimento considerável, sendo um dos principais alvos da odontologia moderna. Materiais e técnicas como: Cerâmicas reforçadas; Dissilicato de lítio; Alumina infiltrada por vidro; Zircônia infiltrada por vidro Zircônia; Estratificação e CAD/CAM tem demonstrado eficácia e comprovações em sua utilização. O objetivo desse trabalho é efetuar uma revisão narrativa sobre o progresso das facetas laminadas utilizadas pelos Cirurgiões-dentistas (CD’s), visando colaborar com a escolha e recomendação dos materiais cerâmicos.
- Published
- 2021
29. Evaluación de la Calidad de Vida en pacientes rehabilitados de cáncer de cabeza y cuello: aplicación del Análisis Factorial Confirmatorio para la validación de constructo
- Author
-
Ferreira, Léslie Piccolotto, Santos, Patrícia Rocha dos, Tozzo, Ana Paula da Silva, Araujo, Andre Luiz Lopes de, Freitas , Giséli Pereira de, Raignieri, Jéssica, Martins, Marcella Ferrari, Silva, Rosy Neves da, Cirillo , Paulo Iakowski, and Peres, Stela Verzinhasse
- Subjects
Quality of life ,Neoplasias de cabeza y cuello ,Prostheses and implants ,Qualidade de vida ,Prótesis e implantes ,Oncology ,Neoplasias de cabeça e pescoço ,Oncologia ,Calidad de vida ,Próteses e implantes ,Head and neck neoplasms ,Oncología - Abstract
Objective: To apply the Confirmatory Factor Analysis (CFA) technique in a quality of life instrument (WHOQOL-bref), validated for the Portuguese language of Brazil, in patients with maxillofacial prosthesis. Method: exploratory study with retrospective collection of 193 patients with maxillofacial prosthesis seen at Fundação Oncocentro de São Paulo, SP, from 2016 to 2019. Demographic data (gender, age over 18 years, federative unit and date of birth) were included to characterize the sample. lifestyle (alcohol and tobacco consumption) and clinics. Medical records with more than 70% of the variables without information were excluded. The WHOQOL-bref instrument was filled in after indicating the prosthesis. Cronbach's alpha was applied to assess internal consistency and Confirmatory Factor Analysis for construct validity. Results: the instrument showed excellent internal consistency regarding its overall score (alpha = 0.82). For Confirmatory Factor Analysis, the parameters showed the feasibility of the analysis (higher = 0.50). Conclusion: the analysis showed that the WHOQOL-bref instrument can be applied to assess quality of life in patients with maxillofacial prosthesis. The use of this instrument allows the comparison of quality of life between different pathologies, as well as evaluation and monitoring of therapeutic processes. Objetivo: Aplicar la técnica de Análisis Factorial Confirmatorio (AFC) en un instrumento de calidad de vida (WHOQOL-bref), validado para el idioma portugués de Brasil, en pacientes con prótesis maxilofacial. Método: estudio exploratorio con colección retrospectiva de 193 pacientes con prótesis maxilofacial, de ambos sexos, mayores de 18 años, atendidos en Fundação Oncocentro de São Paulo, SP, en el período de 2016 a 2019. El instrumento WHOQOL-bref se completó después de que se indicó la prótesis. Se aplicó el alfa de Cronbach para evaluar la consistencia interna y el Análisis Factorial Confirmatorio para la validez de constructo. Resultados: el instrumento mostró una excelente consistencia interna con respecto a su puntuación global (alfa = 0,82). Para el Análisis Factorial Confirmatorio, los parámetros mostraron la viabilidad del análisis (mayor = 0,50). Conclusión: el análisis mostró que el instrumento WHOQOL-bref se puede aplicar para evaluar la calidad de vida en pacientes con prótesis maxilofacial. El uso de este instrumento permite la comparación de la calidad de vida entre diferentes patologías, así como la evaluación y seguimiento de procesos terapéuticos. Objetivo: Avaliar a QV de pacientes em uso de prótese bucomaxilofacial, bem como a confiabilidade e a validade dos constructos do WHOQOL-bref. Método: estudo transversal com 193 pacientes, de ambos os sexos, acima de 18 anos, atendidos na Fundação Oncocentro de São Paulo, SP, no periodo de 2016 a 2019. O teste de Mann-Whitney foi aplicado para avalair a diferença entre as variáveis demográficas e clínicas versus os domínios do WHOQOL-bref. Na análise de validação foram aplicados os testes de alfa de Cronbach e a Análise Fatorial Confirmatória. Resultados: Houve diferença entre os sexos para os domínios Psicológico e Ambiental (p
- Published
- 2022
30. Detecção de microrganismos em dispositivos ortopédicos sonicados clínicos usando cultura convencional e qPCR
- Author
-
Ribeiro,Victoria Stadler Tasca, Cieslinski,Juliette, Bertol,Julia, Schumacher,Ana Laura, Telles,João Paulo, and Tuon,Felipe Francisco
- Subjects
sonication ,spectrometry ,qPCR ,espectrometria de massas por ionização e dessorção a laser assistida por matriz ,matrix-sssisted laser desorption-ionization ,prostheses and implants ,sonicação ,próteses e implantes ,mass ,infecções ,infections - Abstract
Objective To evaluate the sensitivity and specificity of the quantitative real-time polymerase chain reaction (qPCR) for 16S rDNA gene screening using sonicated fluid from orthopedic implants. Methods A retrospective study was conducted on 73 sonicated fluids obtained from patients with infection associated with orthopedic implants. The samples were subjected to conventional culture and molecular testing using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and qPCR for 16S rDNA. The cycle threshold values were used to define a cut-off of the qPCR of the 16S rDNA for negative and positive cultures. Results No statistical differences were observed between the positive and negative culture groups based on the time from the first surgery to infection (p= 0.958), age (p =0.269), or general comorbidities. Nevertheless, a statistical difference was found between the mean duration of antibiotic use before device removal (3.41 versus 0.94; p =0.016). Bacterial DNA was identified in every sample from the sonicated fluids. The median cycle thresholds of the positive and negative cultures were of 25.6 and 27.3 respectively (p< 0.001). As a diagnostic tool, a cycle threshold cut-off of 26.89 demonstrated an area under the curve of the receiver operating characteristic of 0.877 (p≤ 0.001). Conclusion The presence of antimicrobial agents for more than 72 hours decreased culture positivity, but did not influence the qPCR results. Despite this, amplification of the 16S rDNA may overestimate infection diagnosis. Resumo Objetivo Avaliar a sensibilidade e a especificidade da reação em cadeia de polimerase em tempo real quantitativa (quantitative real-time polymerase chain reaction, qPCR, em inglês) para a triagem do gene rDNA 16S, com a utilização do fluido sonicado de implantes ortopédicos. Métodos Um estudo retrospectivo foi realizado em 73 fluidos sonicados obtidos de pacientes com infecção associada aos implantes ortopédicos. As amostras foram submetidas a cultura convencional e a teste molecular utilizando ionização e dessorção a laser assistida por matriz com espectrometria de massa por tempo de voo (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, MALDI-TOF MS, em inglês) e qPCR para o gene rDNA 16S. Os valores limiares do ciclo foram usados para definir um ponto de corte para a qPCR do gene rDNA 16S para culturas negativas e positivas. Resultados Não foram observadas diferenças estatísticas entre os grupos de cultura positiva e negativa com base no tempo desde a primeira cirurgia até a infecção (p= 0,958), na idade (p= 0,269), ou nas comorbidades em geral. No entanto, uma diferença estatística foi encontrada entre a duração média do uso de antibióticos antes da remoção do dispositivo (3,41 versus 0,94; p= 0,016). O DNA bacteriano foi identificado em todas as amostras dos fluidos sonicados. Os limiares do ciclo médio de culturas positivas e negativas foram de 25,6 e 27,3, respectivamente (p< 0,001). Como uma ferramenta de diagnóstico, um corte do limite do ciclo de 26,89 demonstrou uma área sob a curva da característica de operação do receptor de 0,877 (p ≤ 0,001). Conclusão A presença de agentes antimicrobianos por mais de 72 horas diminuiu a positividade da cultura, mas não influenciou os resultados da qPCR. Apesar disso, a amplificação do rDNA 16S pode sobrestimar o diagnóstico de infecção.
- Published
- 2022
31. Atuação de equipe multiprofissional no atendimento à pessoa amputada: contextualizando serviços e protocolos hospitalares.
- Author
-
Kons dos Santos, Bárbara, Tonon da Luz, Soraia Cristina, dos Santos, Kadine Bender, da Silva Honório, Gesilani Júlia, and de Oliveira Farias, Gelcemar
- Subjects
AMPUTATION ,AMPUTEES ,HEALTH care teams ,INTERVIEWING ,RESEARCH methodology ,MEDICAL protocols ,MEDICAL referrals ,POSTOPERATIVE care ,PREOPERATIVE care ,SURGICAL dressings ,QUALITATIVE research ,REHABILITATION - Abstract
Copyright of Brazilian Journal of Occupational Therapy / Cadernos Brasileiros de Terapia Ocupacional is the property of Cadernos de Terapia Ocupacional da UFSCar and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
32. Implant-Supported Fixed Partial Prostheses With Different Prosthetic Materials: A Three-Dimensional Finite Element Stress Analysis.
- Author
-
Arinc, Hakan
- Subjects
PROSTHETICS ,COMPACT bone ,DENTAL implants ,ZIRCONIUM oxide ,FINITE element method - Abstract
Copyright of Implant Dentistry is the property of Lippincott Williams & Wilkins and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
33. Efficacy of the Canabrava Ring (pupil expansion device) in cataract surgery for eyes with small pupils: the first 30 cases.
- Author
-
Canabrava, Sérgio, Henriques Rezende, Pedro, Coutinho Eliazar, Glauber, Barbosa de Figueiredo, Sophia, Fernandes Resende, Arthur, Duarte Batista, Wagner, and Diniz-Filho, Alberto
- Subjects
CATARACT surgery ,MIOSIS ,PHACOEMULSIFICATION ,INTRAOCULAR lenses ,VISUAL acuity - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
34. Evaluation of Failed Implants by Metallographic and Energy Dispersive X-ray Analysis.
- Author
-
de Alcântara Pinto, Clarice Maia Soares, Goulart, Douglas Rangel, Asprino, Luciana, Olate, Sérgio, and de Moraes, Márcio
- Subjects
DENTAL implants ,ENERGY dispersive X-ray spectroscopy ,METALLOGRAPHY ,TITANIUM ,OSSEOINTEGRATION ,THERAPEUTICS - Abstract
Copyright of Implant Dentistry is the property of Lippincott Williams & Wilkins and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
35. Sumário da prevenção da trombose venosa profunda na artroplastia total do joelho.
- Author
-
Cesar Gali, Julio and da Silva, Phelipe Augusto Cintra
- Abstract
The authors report a succinct update of the main deep vein thrombosis prevention methods after total knee arthroplasty, divided into mechanical and pharmacological. They relate the main drugs used, their dosage and comparative risks and benefits. [ABSTRACT FROM AUTHOR]
- Published
- 2018
- Full Text
- View/download PDF
36. Zirconia in Dentistry: mini-review
- Author
-
Andréa Cândido dos Reis and Simone Kreve
- Subjects
Ceramics ,Zirconium ,Prostheses and implants ,Physics ,cerâmica ,zircônio ,Odontologia ,Materiais Odontológicos ,Dentistry ,próteses e implantes ,RK1-715 ,Cerâmica ,Zircônio ,Próteses e implantes ,Microbiology ,Humanities ,Mini review - Abstract
Objetivo: O objetivo deste estudo é fornecer ao cirurgião-dentista conhecimento sobre aspectos gerais da zircônia e abordar a introdução das diferentes gerações. Materiais e métodos: Foi realizada uma pesquisa eletrônica da literatura atual em inglês, incluindo artigos científicos publicados até 2019. Resultados: De acordo com os artigos selecionados, diferenças importantes foram encontradas em relação as novas composições da zircônia, sua microestrutura, diferenças no conteúdo da fase cúbica, e de ítria na fase tetragonal, levando a diferentes propriedades ópticas, mecânicas e de resistência ao envelhecimento. Conclusão: A zircônia é o material mais resistente disponível entre as cerâmicas, com diferenças mecânicas e ópticas entre os materiais disponíveis. A introdução das coroas monolíticas resolveu o problema de lascamento da porcelana de cobertura, mas foram necessárias modificações estruturais para fornecer adequada translucidez., Purpose: This study aims to provide knowledge to clinicians about general aspects of zirconia and to approach the introduction of different zirconia generations. Methods: An electronic search of the English current literature was conducted including scientific articles published up to 2019. Results: According to the selected articles, important differences were found in terms of the novel compositions of zirconia, microstructures among the materials, differences in cubic phase content and yttria in the tetragonal phase, leading to different optical, mechanical and aging resistance properties. Conclusion: Zirconia is the most resistant material available among ceramics with mechanical and optical differences on available materials. The introduction of the monolithic crowns solving the veneering delamination but structural modifications were necessary to provide adequate translucency.
- Published
- 2021
37. Biomechanical behavior of implants with prosthetic connection of the morse (Cone) type, with different angulations at the implant-abutment interface in multiple dental prostheses: a finite element study
- Author
-
Michel Faivro Almeida SERPA, Bruno Salles SOTTO-MAIOR, Carlos Eduardo FRANCISCHONE, Mateus Antunes RIBEIRO, and Wellington LIMA
- Subjects
Implantação dentária ,Dental implantation ,Finite element analysis ,Análise de elementos finitos ,Próteses e implantes ,Prostheses and implant ,General Dentistry - Abstract
Objective: Evaluate the biomechanical behavior of the influence of different internal angles of conical prosthetic connections in fixed partial prostheses of three elements, through the tridimensional finite element method. Methods: Two different models of segment of the posterior portion of the mandible, with two implants with conical connections at angulations of 11.5 and 16 degrees. Afterwards, and occlusal load of 180N was used, and divided into 2 points of application on the premolar, and 400N divided into 5 points of application on the molar. Data were acquired as the tensile, compressive and shear stresses on cortical and medullary bone, and von Mises stresses on implants and prosthetic components of two implants in both in three-unit fixed partial prosthesis. In the quantitative analysis, both in cortical and medullary bone, the tension peaks in tensile, compression, and shear forces were higher for the CM16 group. Results: When analyzing qualitatively, the cortical and medullary bones presented a greater stress around the implant platform with a higher incidence in the implant in the molar region. In the von Misses analysis in both groups, the tensions were concentrated in the cervical region of the implants, in the first threads, in the premolar and molar regions. Regarding prosthetic pillars, the stress concentration was located in the region of contact with the implant. Conclusion: The increased angulation of conicity of the internal conical connections represents a determinant factor to increase in stress concentration in the implants, prosthetic components and adjacent structures, such as the cortical and medullary bone. RESUMO Objetivo: Avaliar a influência das diferentes angulações internas de conexões protéticas cônicas em próteses parciais fixas de três elementos, em relação a distribuição de tensões no osso cortical e medular adjacente, também como nos implantes e componentes protéticos através do método dos elementos finitos. Métodos: Foram analisados de forma quantitativa e qualitativa, através do método de elementos finitos, as tensões de tração, compressão e cisalhamento no osso cortical e medular, e tensões de von Misses nos implantes e componentes protéticos de dois implantes, um com conexão cônica de 11.5 graus e o outro de 16 graus. Ambos em prótese múltipla de três elementos. Resultados: Na análise quantitativa, tanto no osso cortical quanto no medular, os picos de tensão nas forças de tração, compressão, e de cisalhamento foram maiores para o grupo CM16, se comparado ao CM11,5, exceto a força de cisalhamento do osso cortical, que obteve valores muito próximos em ambos os grupos. Ao se analisar qualitativamente, os ossos corticais e medulares apresentaram um maior stress ao redor da plataforma dos implantes com incidência maior no implante na região do molar. Na análise von Misses em ambos os grupos, as tensões concentraram-se na região cervical dos implantes, nas primeiras roscas, nas regiões de pré-molar e molar. No que diz respeito aos pilares protéticos, a concentração de tensões foi localizada na região de contato com o implante. Conclusão: Podemos concluir que conforme o ângulo da interface implante-pilar aumenta, ocorre uma incidência maior de tensões em todas as áreas envolvidas nesse estudo.
- Published
- 2022
38. Diferentes sistemas de implantes dentales: una revisión descriptiva de la literatura
- Author
-
Moreira, Guilherme Matos, Peres, Gustavo de Mattos, and Reis , Tais Alves dos
- Subjects
Implantes dentales ,Health teaching ,Dental implants ,Implantes dentários ,Odontología ,Ensino em saúde ,Odontologia ,Prótesis e implantes ,Mouth rehabilitation ,Rehabilitación bucal ,Enseñanza en salud ,Prostheses and implants ,Dentistry ,Próteses e implantes ,Reabilitação bucal - Abstract
Every day the search for a harmonious and beautiful smile increases, and this harmony ends up being affected by the absence of one or more teeth, a few decades ago the only options for dental surgeons to rehabilitate these patients was through the manufacture of total or partial dentures, however Since the end of the 60's when Bränemark introduced the osseointegrated implants to the world, these options have expanded, initially the implants had an external hexagon connection system, with the advancement of technology and the development of new research to improve the implants, implants with internal hexagon, Cone Morse and finally the Grand Morse, it is extremely important that implantodontists know each system so that they know when they can be indicated as well as their advantages and disadvantages. This work aims to create an information cluster which will help both dental academics and professionals in the field about dental implant systems with connections such as External Hexagon, Internal Hexagon, Morse Cone and Grand Morse. A descriptive narrative literature review was carried out on the subject in question, using as a bibliographic basis scientific articles presented in Portuguese, English and French, available in databases such as VHL salud, Scielo and Pubmed. After analyzing all the material used as a bibliographic basis for the accomplishment of this work, it is concluded that all types of implants with their different types of connection mentioned in this work are efficient within their indications. Cada día se incrementa la búsqueda de una sonrisa armoniosa y bella, y esta armonía termina viéndose afectada por la ausencia de uno o más dientes, hace algunas décadas las únicas opciones que tenían los cirujanos dentistas para rehabilitar a estos pacientes era a través de la fabricación de dientes totales o parciales. prótesis dentales, sin embargo Desde finales de los años 60 cuando Bränemark introdujo los implantes osteointegrados al mundo, estas opciones se han ampliado, inicialmente los implantes tenían un sistema de conexión de hexágono externo, con el avance de la tecnología el desarrollo de nuevas investigaciones para mejorar los implantes, implantes con hexágono interno, Cono Morse y finalmente el Gran Morse, es sumamente importante que los implantodontistas conozcan cada sistema para que sepan cuándo pueden estar indicados así como ventajas y desventajas. Este trabajo tiene como objetivo crear un clúster de información que ayude tanto a los académicos dentales como a los profesionales en el campo sobre los sistemas de implantes dentales con conexiones como External Hexagon, Internal Hexagon, Morse Cone Grand Morse. Se realizó una revisión bibliográfica narrativa descriptiva sobre el tema en cuestión, utilizando como base bibliográfica artículos científicos presentados en portugués, inglés y francés, disponibles en bases de datos como BVS salud, Scielo y Pubmed. Luego de analizar todo el material utilizado como base bibliográfica para la realización de este trabajo, se concluye que todos los tipos de implantes con sus diferentes tipos de conexión mencionados en este trabajo son eficientes dentro de sus indicaciones. A cada dia a procura por um sorriso harmônico e bonito aumenta, e está harmonia acaba sendo afetada pela ausência de um ou mais dentes, a algumas décadas as únicas opções para os cirurgiões dentistas reabilitarem esses pacientes era através da confecção de próteses totais ou parciais porém desde o final da década de 60 quando Bränemark apresentou ao mundo os implantes ósseointegraveis essa opções ampliaram, inicialmente os implantes possuíam um sistema de conexão de hexágono externo, com o avanço da tecnologia e o desenvolvimento de novas pesquisas para melhorar os implantes surgiram os implantes com hexágono interno, Cone Morse e por último os Grand Morse, é extremamente importante que os implantodontistas conheçam cada sistema para que saibam quando podem ser indicados bem como suas vantagens e desvantagens. Este trabalho objetiva a criação de um aglomerado informacional o qual auxiliara tanto acadêmicos de odontologia quanto profissionais da área acerca dos sistemas de implantes dentários com conexões do tipo hexágono Externo, hexágono Interno, Cone Morse, e Grand Morse. Foi realizada uma revisão da literatura narrativa descritiva acerca do tema em questão, utilizando como base bibliográfica artigos científicos apresentados nas línguas portuguesa, inglesa e francesa, disponíveis em bases de dado como BVS salud, Scielo e Pubmed. Após analisar todo o material utilizado como base bibliográfica para a realização deste trabalho, conclui-se que todos os tipos de implantes com seus diferentes tipos de conexão citados neste trabalho, são eficientes dentro de suas indicações.
- Published
- 2022
39. Evaluation of the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty
- Author
-
Victor Magalhães Callado, Osamu de Sandes Kimura, Diogo de Carvalho Leal, Pedro Guilme Teixeira de Sousa Filho, Marco Bernardo Cury Fernandes, and Emílio Henrique Carvalho de Almendra Freitas
- Subjects
Artroplastia de quadril ,Cunha de metal trabeculado ,Próteses e implantes ,Defeitos ósseos acetabulares ,Medicine ,Orthopedic surgery ,RD701-811 - Abstract
Objective:this study aimed to evaluate the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty.Methods:twenty-three cases with minimum grading of Paprosky II-B that were operated between July 2008 and February 2013 were evaluated. These cases were evaluated based on radiographs before the operation, immediately after the operation and later on after the operation. Loss of fixation was defined as a change in the abduction angle of the component greater than 10° or any mobilization greater than 6 mm.Results:it was found that there was 100% fixation of the acetabula after a mean of 29.5 months. One case underwent removal of the implanted components due to infection.Conclusions:there is still no consensus regarding the best option for reconstructing hips with bone loss. However, revision using a trabecular metal wedge has presented excellent short-and medium-term results. This qualifies it as an important tool for achieving a fixed and stable acetabular component.
- Published
- 2014
- Full Text
- View/download PDF
40. Reverse arthroplasty of the shoulder for treating rotator cuff arthropathy
- Author
-
Marcus Vinicius Galvão Amaral, José Leonardo Rocha de Faria, Gláucio Siqueira, Marcio Cohen, Bruno Brandão, Rickson Moraes, Martim Monteiro, and Geraldo Motta
- Subjects
Artroplastia ,Ombro ,Artropatias ,Bainha rotadora ,Próteses e implantes ,Medicine ,Orthopedic surgery ,RD701-811 - Abstract
OBJECTIVE: to present a retrospective analysis on the clinical-functional results and complications among patients with rotator cuff arthropathy (RCA) who underwent reverse arthroplasty of the shoulder.METHODS: patients with a diagnosis of RCA associated with pseudoparalysis of anterior elevation who underwent reverse arthroplasty of the shoulder with a minimum follow-up of one year were selected.RESULTS: preoperative information was gathered from our shoulder and elbow arthroplasty register, comprising age, sex, laterality, history of previous procedures, Constant's functional scores and the preoperative range of motion as described in the protocol of the American Academy of Shoulder and Elbow Surgery (ASES). After a mean follow-up of 44 months, 17 patients (94%) were satisfied with the result from the procedure.CONCLUSION: reverse arthroplasty for treating RCA in patients with pseudoparalysis of the shoulder was shown to be effective in achieving a statistically significant improvement in range of motion regarding anterior flexion and abduction. However, in this series, there was no improvement in range of motion regarding external and internal rotation. Reverse arthroplasty is a procedure that reestablishes shoulder joint function in patients who previously did not present any therapeutic possibilities.
- Published
- 2014
- Full Text
- View/download PDF
41. Use of a trabecular metal cone made of tantalum, to treat bone defects during revision knee arthroplasty
- Author
-
Alan de Paula Mozella, Ricardo Reiniger Olivero, and Hugo Alexandre de Araújo Barros Cobra
- Subjects
Artroplastia do joelho ,Próteses e implantes ,Tântalo ,Osteointegração ,Medicine ,Orthopedic surgery ,RD701-811 - Abstract
OBJECTIVES: the aim of this study was to evaluate the surgical technique and determine the initial results, with a minimum follow-up of two years, from total knee arthroplasty revisions in which trabecular metal cones made of tantalum were used at the Knee Surgery Center of the National Institute of Traumatology and Orthopedics (INTO) or at the authors' private clinic between July 2008 and December 2010.METHODS: ten patients were included in the study prospectively, through clinical and radiographic evaluations.RESULTS: seven patients presented evolution without complications relating to the tantalum cones used. Five of these patients said that they did not have any pain and all of them were able to walk without needing crutches. In all the cases, we observed that osseointegration of the tantalum cones had occurred. No migration or loosening of the implants was observed, nor was osteolysis.CONCLUSION: use of trabecular metal cones made of tantalum for treating AORI type II or II bone defects was capable of providing efficient structural support to the prosthetic revision implants, in evaluations with a short follow-up.
- Published
- 2014
- Full Text
- View/download PDF
42. Aspectos clínicos do implante vestibular em humanos
- Author
-
Pimentel, Bianca Nunes and Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
- Subjects
Prostheses and implants ,Vestibular diseases ,Vestibulo-ocular reflex ,Eletric Stimulation ,Próteses e implantes ,Estimulação elétrica ,Doenças vestibulares ,Reflexo vestíbulo-ocular ,Ciências da Saúde ,Otorrinolaringologia ,Fonoaudiologia - Abstract
Objective: analyze the results obtained in the international literature on the Vestibular Implant, considering the advances regarding surgery and recovery of implanted subjects. Material and Methods: The electronic search was carried out in Portal of Journals CAPES, in March 2020. The descriptors with the following search strategy were vestibular implant* OR vestibular prosth* OR (electrical stimulation AND vestibular). The selection criteria were studies on vestibular implant surgery, with human beings, in the last ten years, only articles, in English language, peer-reviewed.Results: Of the 14 selected articles, the majority cited the modified cochlear implants in vestibular implants or hybrid. The most indicated cases are bilateral vestibular loss. About surgical approaches, it can be intralabyrinthine, with insertion of the electrode in the semicircular channel or extralabyrinthine, in which the electrode takes the information directly to the nerves.Conclusion: The studies report the partial restoration of the vestibulo-ocular reflex electrically evoked that resembles the natural reflex, favoring dynamic visual skills and head movements. There is also reference to other vestibular reflexes, which generate controlled postural responses, as well as vestibular sensations, but still highly variable among the subjects. Objetivo: analisar os resultados obtidos na literatura internacional sobre o Implante Vestibular, considerando os avanços alcançados quanto à cirurgia e recuperação de sujeitos implantados.Materiais e Métodos: A busca eletrônica foi realizada no Portal de periódicos da CAPES, em março de 2020. Foram utilizados os descritores com a seguinte estratégia de busca: Vestibular implant* OR Vestibular prosth* OR (electrical stimulation AND vestibular). Os critérios de seleção foram: estudos sobre a cirurgia do implante vestibular, com seres humanos, nos últimos dez anos, material tipo artigo, no idioma Inglês, revisado por pares.Resultados: Dos 14 artigos selecionados, a maioria citou o implante vestibular modifi cado de implantes cocleares ou híbridos. É indicado, principalmente, nos casos de perda da hipofunção vestibular bilateral. Quanto às abordagens cirúrgicas destacam-se a intralabiríntica, com inserção do eletrodo no canal semicircular ou extralabiríntica, na qual o eletrodo leva a informação diretamente aos nervos.Conclusão: Os estudos relatam a restauração parcial do reflexo vestíbulo-ocular evocado eletricamente o qual se aproxima do reflexo natural, favorecendo as habilidades visuais dinâmicas e os movimentos de cabeça. Também há referência aos outros reflexos vestibulares, os quais geram respostas posturais controladas, bem como sensações vestibulares, porém ainda altamente variáveis entre os sujeitos.
- Published
- 2022
43. Avaliação dos dados da requisição médica e do questionário prévio ao exame de ressonância magnética da mama em pacientes portadoras de implantes de silicone.
- Author
-
Anger, Jaime, Eduardo Elias, Pablo, de Camargo Moraes, Paula, and Hamerschlak, Nelson
- Abstract
Objective: To analyze the quality and quantity of data in the questionnaires and in request forms for magnetic resonance imaging. Methods: This retrospective study was conducted with data from 300 medical records. The research used the following data from the questionnaires: patient age, reason for the magnetic resonance imaging, reason for placing the breast implant, report of any signs or symptoms, time elapsed since surgery to place the current breast implant, replacement implant surgery, chemotherapy, and/or radiation therapy treatments. From the magnetic resonance imaging request forms, information about the breast implant, the implant placement surgery, patient clinical information and ordering physician specialty were verified. Results: The mean age of patients was 48.8 years, and the mean time elapsed since breast implant surgery was 5 years. A total of 60% of women in the sample were submitted to aesthetic surgery, while 23.7% were submitted to chemotherapy and/or radiation therapy. In the request forms, 23.7% of physicians added some piece of information about the patient, whereas 2.3% of them informed the type of implant and 5.2% informed about the surgery. Conclusion: The amount of information in the magnetic resonance imaging request forms is very limited, and this may hinder quality of radiological reports. Institutional and technological measures should be implemented to encourage the requesting physicians and radiologists to share information. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF
44. Expansão maxilar em duas etapas usando barreira de polipropileno: relato de caso.
- Author
-
Medina Llantoy, Paul Christian and Ticona Humani, Nohemi Amelia
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2017
- Full Text
- View/download PDF
45. Avaliação audiométrica após estapedotomia com prótese de titânio do tipo Fisch Audiometric evaluation after stapedotomy with Fisch titanium prosthesis
- Author
-
Andre Luiz de Ataide, Gerson Linck Bichinho, and Tatiana Mauad Patruni
- Subjects
otosclerose ,próteses e implantes ,substituição ossicular ,titânio ,ossicular replacement ,otosclerosis ,prostheses and implants ,titanium ,Otorhinolaryngology ,RF1-547 - Abstract
Otosclerose é uma doença que provoca fixação do estribo, levando à perda auditiva tipicamente condutiva, corrigida com aparelhos auditivos ou cirurgia de estapedotomia, substituindo o estribo doente por uma prótese. O material mais recentemente utilizado é o titânio e no Brasil há apenas duas próteses comercialmente disponíveis. A prótese de pistão tipo Fisch, da Storz, não possui resultados relatados na literatura. OBJETIVO: Estudo retrospectivo avaliando resultado auditivo após estapedotomia com uso desta prótese. MÉTODO: Usando critérios da Academia Americana de Otorrinolaringologia, comparou-se o gap nas audiometrias pré e pós-operatórias, avaliando-se melhora auditiva. RESULTADOS: O gap pós-operatório em baixas frequências teve média de 12,9 dB, em altas frequências de 5,2 dB (média 9,1 dB), mediana 8,8 dB, mínimo 1,3 dB e máximo 21,6 dB, desvio padrão 5,7 e p < 0,001. Dividindo o resultado conforme o gap pós-operatório a cada 10 dB, em 25 pacientes (75,8%) foi < ou igual a 10 dB, em 32 pacientes (96,9%) foi < ou igual a 20 dB, em 100% dos casos foi < ou igual a 30 dB. CONCLUSÃO: Prótese de pistão tipo Fisch apresenta resultados compatíveis com a literatura, podendo ser usada com segurança como mais uma boa opção para estapedotomia.Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis. OBJECTIVE: This retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation. METHOD: The criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests. RESULTS: The mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under. CONCLUSION: The Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy procedures.
- Published
- 2013
46. Prospective randomized study after the use of drains in total knee arthroplasty with implant
- Author
-
Rogério Franco de Araujo Goes, Anselmo Fernandes da Silva, Fábio Soares Lyra, Fabricio Bolpato Loures, Idemar Monteiro Da Palma, Hugo Alexandre de Araujo de Barros Cobra, and Pedro José Labronici
- Subjects
Artroplastia total do joelho ,Canal de drenagem ,Próteses e implantes ,Medicine ,Orthopedic surgery ,RD701-811 - Abstract
OBJECTIVE: to compare the laboratorial results of opening suction drainage 6 hours and 12 hours after total knee arthroplasty surgery. METHODS: prospective and randomized study in 88 patients undergoing with total knee arthroplasty in two groups: in one group the opening suction drainage was performed 6 hours (n = 45) after the surgery and in the other 12 hours (n = 43) after the surgery. RESULTS : the outcome was a significant fall in the three laboratorial variables (hemoglobin, red blood cells and hematocrit) between the pre and post-operative in the total sample and in the six and 12 hour opening suction drainage groups. In the group with opening suction drainage after 12 hours, the drainage volume was significantly lower than in the group with opening suction drainage after 6 hours (p = 0.0003). However, no significant difference was observed in the absolute delta of the laboratorial variables between the two groups. CONCLUSION: the opening suction drainage in six and 12 hours did not show significant difference from the laboratorial values although the volume of the blood drained was higher in the opening suction drainage in six hours.
- Published
- 2013
- Full Text
- View/download PDF
47. Implantes extraorais em pacientes irradiados Extraoral implants in irradiated pacients
- Author
-
Joaquim Augusto Piras de Oliveira, Márcio Abrahão, and Luciano Lauria Dib
- Subjects
próteses e implantes ,radioterapia ,osseointegration ,implants ,radiotherapy ,Otorhinolaryngology ,RF1-547 - Abstract
O objetivo deste trabalho foi avaliar o resultado da osseointegração de implantes extraorais lemento de suporte e retenção de próteses nas reabilitações de deformidades faciais. MÉTODO: Estudo retrospectivo de prontuários de 59 indivíduos operados de câncer, submetidos a 164 implantes para retenção de prótese facial. RESULTADOS: Dos 59 indivíduos, 14 foram previamente irradiados e receberam 42 implantes. Quarenta e cinco indivíduos não foram irradiados e receberam 122 implantes. Do total de 164 implantes, oito não osseointegraram, dos quais dois foram instalados em osso previamente irradiados. O resultado representou o sucesso de 116 (95,1%) implantes osseointegrados nos indivíduos não irradiados. E sucesso de 40 (95,3%) implantes osseointegrados em ossos irradiados. CONCLUSÃO: Concluiu-se que o uso de implantes extraorais é uma técnica segura e eficaz como suporte e retenção para próteses faciais em indivíduos com deformidades nessa região. A radioterapia não impede a osseointegração.The aim of this study is to analyze the success of extraoral osseointegrated implants used to support designed to rehabilitate craniofacial deformities. METHOD: This study was based on the retrospective assessment of charts from 59 patients submitted to cancer surgery and who received 164 extraoral implants to contain facial prosthesis. RESULTS: Among 164 implants, 42 were fixed in previously irradiated regions. Eight of the implants did not have osseointegration; and from these, two were fixed in irradiated bone. The result show 116 (95.1%) successfully osseointegrated implants in non-irradiated sites. The success rate among 42 implants fixed in previously irradiated bones was 40 (95.3%) osseointegrated implants. CONCLUSION: The use of extraoral craniofacial implants represents a safe and effective approach to treat facial deformities as a support for the rehabilitation prosthesis. Radiotherapy treatment does not prevent osseointegration.
- Published
- 2013
48. Avaliação do implante coclear Digisonic® SP: evolução dos pacientes e sistema de fixação com parafusos de titânio Evaluation of the Digisonic® SP cochlear implant: patient outcomes and fixation system with titanium screws
- Author
-
Guilherme Machado de Carvalho, Alexandre Caixeta Guimarães, Fabiana Danieli, Lúcia Cristina Beltrame Onuki, Jorge Rizzato Paschoal, Walter Adriano Bianchini, and Arthur Menino Castilho
- Subjects
eletrodos implantados ,implante coclear ,perda auditiva neurossensorial ,próteses e implantes ,surdez ,cochlear implantation ,deafness ,electrodes ,implanted ,hearing loss sensorineural ,prostheses and implants ,Otorhinolaryngology ,RF1-547 - Abstract
O implante coclear para pacientes com disacusia grave/profunda revolucionou o modo com que estes interagem com o meio ambiente. A Neurelec desenvolveu um sistema que permite fixação com uso de dois simples parafusos de titânio, sem necessidade de broqueamento do osso do crânio do paciente. Este artigo teve o objetivo de descrever uma casuística de pacientes submetidos a implante coclear com o Digisonic® SP, para mostrar os resultados cirúrgicos e detalhes do procedimento. MÉTODO: Estudo retrospectivo que avaliou os pacientes, no período de 18 meses, submetidos a implante coclear com o Digisonic® SP. Todos os pacientes eram pós-linguais. Coleta dos dados realizada por meio da análise dos prontuários dos pacientes, além de questionário padronizado aplicado nos cirurgiões que realizaram o procedimento. RESULTADOS: Os seis casos implantados com o Digisonic® SP foram realizados por cirurgiões experientes e o tempo cirúrgico variou de 95 a 203 minutos (média de 135 minutos), que é menor do que o descrito com outras formas de fixação. Não houve nenhum tipo de complicação e o ganho auditivo foi satisfatório. CONCLUSÃO: O implante Digisonic® SP desenvolvido pela Neurelec apresentou bons resultados audiológicos em adultos, tempo de cirurgia menor e não ocorreram complicações cirúrgicas ou pós-operatórias.Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. OBJECTIVE: To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. METHOD: This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. RESULTS: The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. CONCLUSION: The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.
- Published
- 2012
- Full Text
- View/download PDF
49. Histopathological reaction over prosthesis surface covered with silicone and polyurethane foam implanted in rats Reação histopatológica sobre a superfície de próteses cobertas por espuma de silicone e poliuretano implantadas em ratos
- Author
-
Jorge Wagenführ-Júnior, Jurandir Marcondes Ribas Filho, Marcelo Mazza do Nascimento, Fernanda Marcondes Ribas, Marcus Vinícius Wanka, and Andressa de Lima Godoi
- Subjects
Próteses e Implantes ,Poliuretanos ,Silicones ,Ratos ,Prostheses and Implants ,Polyurethanes ,Rats ,Surgery ,RD1-811 - Abstract
PURPOSES: To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. METHODS: Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. RESULTS: There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). CONCLUSIONS: Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen than that of the silicone foam implants.OBJETIVOS: Avaliar, em relação ao uso de próteses, se a espuma de poliuretano apresenta maior reação de corpo estranho no organismo ao ser comparada com a espuma de silicone. Se há diferenças na vascularização das cápsulas formada ao redor das duas espumas implantadas. Se as cápsulas dos implantes de espuma de poliuretano apresentam quantidade maior de fibras colágenas ao serem comparadas com as da espuma de silicone. MÉTODOS: Utilizou-se 64 ratos albinos da linhagem Wistar, distribuídos em dois grupos de 34, grupo espuma de poliuretano e grupo espuma de silicone e receberam implantes discóides subcutâneos em seu dorso. Foram analisadas as cápsulas peri-implante com 28 dias, dois, três e seis meses após a introdução. A análise microscópica com H&E considerou as variáveis: inflamação aguda, inflamação crônica, reação de corpo estranho e neoformação vascular. A análise da coloração com picrosirius-red usando ImageProPlus considerou o número de vasos e colágeno tipo I e tipo III. RESULTADOS: Em relação à inflamação aguda e crônica, não foram encontradas diferenças estatísticas nos dois grupos. Todos os animais do grupo poliuretano, em todos os momentos, apresentaram reação de corpo estranho moderada ou intensa e foi encontrada diferença estatística significativa (p=0,046) ao serem comparados com o grupo silicone, cuja reação era ausente ou discreta aos dois meses. A neoformação vascular apresentou diferenças significativas nos dois grupos, aos 28 dias (p=0,0002); o grupo poliuretano com H&E apresentava quantidade maior de vasos neoformados e o mesmo ocorrendo com o picrosirius, cujo número de vasos era maior que no grupo silicone (p=0,001). A área de colágeno em todos os momentos foi maior no grupo poliuretano, sendo significativa com 28 dias (p=0,001) e com dois meses (p=0,030). CONCLUSÕES: A espuma de poliuretano apresentou maior reação de corpo estranho no organismo do que a espuma de silicone. A quantidade de vasos foi maior na cápsula da espuma de poliuretano com 28 dias após o implante. Aos 28 dias as cápsulas dos implantes de espuma de poliuretano apresentaram quantidade significativamente maior de colágeno do que as de espuma de silicone.
- Published
- 2012
- Full Text
- View/download PDF
50. Ceratoprótese de Boston
- Author
-
Sérgio Kwitko and Andressa Prestes Stolz
- Subjects
Doenças da córnea ,Próteses e implantes ,Implantação de próteses ,Ophthalmology ,RE1-994 - Abstract
Uma breve revisão de resultados e complicações da ceratoprótese (KPro) de Dohlman-Doane tipo 1. A KProDohlman-Doane é atualmente uma boa opção em casos graves de cegueira corneana, para os quais o transplante penetrante de córnea não apresenta bom prognóstico. As evoluções no design da KPro e as melhorias no procedimento cirúrgico, aliados a obtenção de condições favoráveis da superfície ocular pré-operatórias, garantem bons resultados da KPro em doenças não autoimunes. As principais complicações da KPro são membrana inflamatória retroprotética de fibrina, glaucoma, necrose corneana, vitreíte e infecção (ceratite e endoftalmite). Acompanhamento constante com exames pós-operatórios periódicos é necessário para monitorar e prevenir complicações sérias.
- Published
- 2012
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.