1. Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it
- Author
-
Niehues SM, Unger JK, Malinowski M, Neymeyer J, Hamm B, and Stockmann M
- Subjects
liver volume ,Computed tomography ,volume assessment ,Medicine - Abstract
Abstract Purpose Volumetric assessment of the liver regularly yields discrepant results between pre- and intraoperatively determined volumes. Nevertheless, the main factor responsible for this discrepancy remains still unclear. The aim of this study was to systematically determine the difference between in vivo CT-volumetry and ex vivo volumetry in a pig animal model. Material and Methods Eleven pigs were studied. Liver density assessment, CT-volumetry and water displacement volumetry was performed after surgical removal of the complete liver. Known possible errors of volume determination like resection or segmentation borders were eliminated in this model. Regression analysis was performed and differences between CT-volumetry and water displacement determined. Results Median liver density was 1.07 g/ml. Regression analysis showed a high correlation of r2 = 0.985 between CT-volumetry and water displacement. CTvolumetry was found to be 13% higher than water displacement volumetry (p < 0.0001). Conclusion In this study the only relevant factor leading to the difference between in vivo CT-volumetry and ex vivo water displacement volumetry seems to be blood perfusion of the liver. The systematic difference of 13 percent has to be taken in account when dealing with those measures.
- Published
- 2010
- Full Text
- View/download PDF