1. Corneal thickness changes during corneal collagen cross-linking with UV-A irradiation and hypo-osmolar riboflavin in thin corneas.
- Author
-
Nassaralla BA, Vieira DM, Machado ML, Figueiredo MN, and Nassaralla JJ Jr
- Subjects
- Adolescent, Adult, Collagen drug effects, Collagen radiation effects, Corneal Pachymetry, Cross-Linking Reagents therapeutic use, Female, Humans, Keratoconus surgery, Male, Osmolar Concentration, Photochemotherapy, Photosensitizing Agents pharmacology, Photosensitizing Agents therapeutic use, Prospective Studies, Riboflavin therapeutic use, Time Factors, Treatment Outcome, Visual Acuity, Vitamin B Complex therapeutic use, Young Adult, Corneal Stroma drug effects, Corneal Stroma radiation effects, Cross-Linking Reagents pharmacology, Riboflavin pharmacology, Ultraviolet Therapy methods, Vitamin B Complex pharmacology
- Abstract
Purpose: To evaluate the thinnest corneal thickness changes during and after corneal collagen cross-linking treatment with ultraviolet-A irradiation, using hypo-osmolar riboflavin solution in thin corneas., Methods: Eighteen eyes of 18 patients were included in this study. After epithelium removal, iso-osmolar 0.1% riboflavin solution was instilled to the cornea every 3 minutes for 30 minutes. Hypo-osmolar 0.1% riboflavin solution was then applied every 20 seconds for 5 minutes or until the thinnest corneal thickness reached 400 µm. Ultraviolet-A irradiation was performed for 30 minutes. During irradiation, iso-osmolar 0.1% riboflavin drops were applied every 5 minutes. Ultrasound pachymetry was performed at approximately the thinnest point of the cornea preoperatively, after epithelial removal, after iso-osmolar riboflavin instillation, after hypo-osmolar riboflavin instillation, after ultraviolet-A irradiation, and at 1, 6 and 12 months after treatment., Results: Mean preoperative thinnest corneal thickness was 380 ± 11 µm. After epithelial removal it decreased to 341 ± 11 µm, and after 30 minutes of iso-osmolar 0.1% riboflavin drops, to 330 ± 7.6 µm. After hypo-osmolar 0.1% riboflavin drops, mean thinnest corneal thickness increased to 418 ± 11 µm. After UVA irradiation, it was 384 ± 10 µm. At 1, 6 and 12 months after treatment, it was 372 ± 10 µm, 381 ± 12.7, and 379 ± 15 µm, respectively. No intraoperative, early postoperative, or late postoperative complications were noted., Conclusions: Hypo-osmolar 0.1% riboflavin solution seems to be effective for swelling thin corneas. The swelling effect is transient and short acting. Corneal thickness should be monitored throughout the procedure. Larger sample sizes and longer follow-up are required in order to make meaningful conclusions regarding safety.
- Published
- 2013
- Full Text
- View/download PDF