24 results on '"Michael Bergler"'
Search Results
2. Ceramic Printing— Comparative Study of the Flexural Strength of 3D-Printed and Milled Zirconia
- Author
-
Francis K. Mante, Michael Bergler, Laura Torrecillas-Martinez, and Jonathan Korostoff
- Subjects
Universal testing machine ,3d printed ,Materials science ,Flexural strength ,visual_art ,Significant difference ,Load cycling ,visual_art.visual_art_medium ,Cubic zirconia ,General Medicine ,Ceramic ,Oral Surgery ,Composite material - Abstract
Purpose To determine and compare the mechanical properties of 3D-printed yttriastabilized zirconia to milled isostatic pressed yttria-stabilized zirconia, with the following hypotheses: (1) The flexural strength of 3D-printed yttria-stabilized zirconia is comparable to milled yttria-stabilized isostatic pressed zirconia; and (2) thermocycling and chewing simulation do not affect the flexural strength of 3D-printed yttria-stabilized zirconia. Materials and methods A total of 30 bars of an experimental 3D-printed 3 mol% yttriastabilized zirconia (LithaCon 3Y 230, Lithoz) and 10 bars of milled isostatic pressed zirconia (Prettau Zirconia, Zirkonzahn) were utilized. The printed zirconia bars were divided into three groups (n = 10 bars per group): (1) untreated (control); (2) thermocycled; and (3) tested after chewing simulation. A flexural strength test was performed on all samples using a three-point bend test in an Instron Universal testing machine. One-way analysis of variance on ranks was used to compare milled to printed zirconia. The effects of thermocycling and load cycling on 3D-printed zirconia were also determined. Results The flexural strength values for milled and printed zirconia were 936.3 ± 255.0 MPa and 855.4 ± 112.6 MPa, respectively. There was no statistically significant difference in flexural strength between the milled and printed zirconia (P = .178). No statistically significant differences were observed between the control 3D-printed zirconia group and the thermocycled (888.4 ± 59.3 MPa) or load-cycled printed zirconia (789.6 ± 133.8 MPa; P = .119). Conclusion Printed 3 mol% yttria-stabilized zirconia has comparable flexural strength to milled yttria-stabilized isostatic pressed zirconia. The thermocycling and chewing simulation used in this study did not significantly alter the flexural strength of the printed 3 mol% yttria-stabilized zirconia. These results indicate a promising role for 3D printing in the fabrication of zirconia restorations. Additional studies are needed to explore the full potential of this technology.
- Published
- 2022
- Full Text
- View/download PDF
3. Room temperature deposition of freestanding BaTiO3 films: temperature-induced irreversible structural and chemical relaxation
- Author
-
Udo Eckstein, Neamul H. Khansur, Michael Bergler, Daisuke Urushihara, Toru Asaka, Ken-ichi Kakimoto, Matej Sadl, Mirela Dragomir, Hana Uršič, Dominique de Ligny, and Kyle G. Webber
- Subjects
Mechanics of Materials ,Mechanical Engineering ,General Materials Science - Abstract
The room temperature aerosol deposition method is especially promising for the rapid deposition of ceramic thick films, making it interesting for functional components in energy, mobility, and telecommunications applications. Despite this, a number of challenges remain, such as an enhanced electrical conductivity and internal residual stresses in as-deposited films. In this work, a novel technique that integrates a sacrificial water-soluble buffer layer was used to fabricate freestanding ceramic thick films, which allows for direct observation of the film without influence of the substrate or prior thermal treatment. Here, the temperature-dependent chemical and structural relaxation phenomena in freestanding BaTiO3 films were directly investigated by characterizing the thermal expansion properties and temperature-dependent crystal structure as a function of oxygen partial pressure, where a clear nonlinear, hysteretic contraction was observed during heating, which is understood to be influenced by lattice defects. As such, aliovalent doping and atmosphere-dependent annealing experiments were used to demonstrate the influence of local chemical redistribution and oxygen vacancies on the thermal expansion, leading to insight into the origin of the high room temperature conductivity of as-deposited films as well as greater insight into the influence of the induced chemical, structural, and microstructural changes in room temperature deposited functional ceramic thick films. Graphical abstract
- Published
- 2022
- Full Text
- View/download PDF
4. Accuracy of Dental and Industrial 3D Printers
- Author
-
Eva Anadioti, Brittany Kane, Yu Zhang, Michael Bergler, Francis Mante, and Markus B. Blatz
- Subjects
Stereolithography ,Polymers ,Printing, Three-Dimensional ,Computer-Aided Design ,General Dentistry ,Article - Abstract
PURPOSE: This in vitro study evaluated the dimensional accuracy of three 3D printers and one milling machine with their respective polymeric materials using a simplified geometrical model. MATERIALS AND METHODS: A simplified computer-aided design (CAD) model was created. The test samples were fabricated with three 3D printers: a dental desktop stereolithography (SLA) printer, an industrial SLA printer, and an industrial fused deposition modeling (FDM) printer, as well as a 5-axis milling machine. One polymer material was used per industrial printer and milling machine while two materials were used with the dental printer for a total of five study groups. Test specimens were then digitized using a laboratory scanner. The virtual outer caliper method was used to measure the linear dimensions of the digitized 3D printed and milled specimens in x-, y-, and z-axes, and compare them to the known values of the CAD model. Data were analyzed with Kruskal-Wallis one-way ANOVA on Ranks followed by the Tukey’s test. RESULTS: Milled specimens were not significantly different from the CAD model in any dimension (p > 0.05). All 3D printed specimens were significantly different from the CAD model in all dimensions (p = 0.01), except the dental SLA 3D printer with one of the polymers tested (Bis-GMA) which was not significantly different in two (x and z) dimensions (p = 0.4 and p = 0.12). CONCLUSIONS: The milling technology tested provided greater dimensional accuracy than the selected 3D printing. Printer, printing technology, and material selection affected the accuracy of the printed model.
- Published
- 2022
- Full Text
- View/download PDF
5. In situ combined stress‐ and temperature‐dependent Raman spectroscopy of Li‐doped (Na,K)NbO 3
- Author
-
Neamul H. Khansur, Udo R. Eckstein, Michael Bergler, Alexander Martin, Ke Wang, Jing‐Feng Li, Maria Rita Cicconi, Keiichi Hatano, Ken‐ichi Kakimoto, Dominique de Ligny, and Kyle G. Webber
- Subjects
Materials Chemistry ,Ceramics and Composites - Published
- 2021
- Full Text
- View/download PDF
6. Factors Affecting the Marginal Fit of CAD-CAM Restorations and Concepts to Improve Outcomes
- Author
-
Wael Isleem, Howard P. Fraiman, Michael Bergler, Alan M. Atlas, Nathaniel D. Lawson, and Ricardo Walter
- Subjects
0301 basic medicine ,business.industry ,Dentistry ,CAD ,030206 dentistry ,Ceramic crown ,Scientific evidence ,03 medical and health sciences ,030104 developmental biology ,0302 clinical medicine ,Immunology and Microbiology (miscellaneous) ,Oral and maxillofacial surgery ,Medicine ,Surgery ,Oral Surgery ,business ,Restorative dentistry - Abstract
With the advent of CAD-CAM technology, it is essential to examine factors that affect outcomes of restorations fabricated by the new methodologies. This report assesses and compares ceramic crown fabrication systems to determine what factors affect marginal fit and provide solutions for better outcomes. The review revealed key scientific evidence about what factors influence the marginal fit of CAD-CAM ceramic restorations. Solutions were recommended to help the clinician achieve greater long-term success when providing this treatment to their patients. The dental microscope enables the dental practitioner to achieve improved clinical outcomes in all phases of restorative dentistry, especially CAD-CAM restorations.
- Published
- 2019
- Full Text
- View/download PDF
7. Sr[Li2Al2O2N2]:Eu2+—A high performance red phosphor to brighten the future
- Author
-
Michael Krause, Thomas Höche, Simon Peschke, Ion Stoll, Christian Patzig, Hubert Huppertz, Gregor J. Hoerder, Philipp Pust, Markus Seibald, Philipp C. Schmid, Dominik Baumann, Stephan Reißaus, Thorsten Schröder, Tobias Tyborski, Dirk Johrendt, Lutz Berthold, Michael Bergler, and Publica
- Subjects
0301 basic medicine ,Multidisciplinary ,Materials science ,business.industry ,Science ,General Physics and Astronomy ,Phosphor ,02 engineering and technology ,General Chemistry ,Energy consumption ,021001 nanoscience & nanotechnology ,General Biochemistry, Genetics and Molecular Biology ,03 medical and health sciences ,Narrow band ,030104 developmental biology ,Optoelectronics ,lcsh:Q ,0210 nano-technology ,business ,Luminous efficacy ,lcsh:Science ,Diode ,Efficient energy use - Abstract
Innovative materials for phosphor converted white light-emitting diodes are in high demand owing to the huge potential of the light-emitting diode technology to reduce energy consumption worldwide. As the primary blue diode is already highly optimized, the conversion phosphors are of crucial importance for any further improvements. We report on the discovery of the high performance red phosphor Sr[Li2Al2O2N2]:Eu2+ meeting all requirements for a phosphor’s optical properties. It combines the optimal spectral position for a red phosphor, as defined in the 2016 Research & Development-plan of the United States government, with an exceptionally small spectral full width at half maximum and excellent thermal stability. A white mid-power phosphor-converted light-emitting diode prototype utilising Sr[Li2Al2O2N2]:Eu2+ shows an increase of 16% in luminous efficacy compared to currently available commercial high colour-rendering phosphor-converted light-emitting diodes, while retaining excellent high colour rendition. This phosphor enables a big leap in energy efficiency of white emitting phosphor-converted light-emitting-diodes. Developing innovative materials for reduced energy consumption in phosphor converted white light-emitting diodes remains a challenge. Here, the authors report a narrow band red-emitting oxonitride material with a highly symmetrical Sr2 + coordination for energy efficient white light-emitting diodes.
- Published
- 2019
8. Comparison of loupes versus microscope-enhanced CAD-CAM crown preparations: A microcomputed tomography analysis of marginal gaps
- Author
-
Alan M. Atlas, Sridhar Janyavula, Rami Elsabee, Emily Alper, Wael F. Isleem, Michael Bergler, and Frank C. Setzer
- Subjects
Oral Surgery - Abstract
Long-term restoration success depends on a precision marginal fit to prevent marginal leakage and caries. The successful fit of a computer-aided design and computer-aided manufactured (CAD-CAM) crown may be affected by different workflow variables, including preparation, scanning, crown design, milling, sintering, and cementation. Discrepancies in any of these steps may result in poor marginal and internal fit. Evidence suggests that tooth preparation may be the most important step in the workflow for a successful outcome. Compared with the traditional means of crown preparation using the naked eye or loupes, the dental operating microscope provides higher magnification and more direct illumination. However, the impact of high magnification during preparation on the marginal quality of CAD-CAM crowns is unclear.The purpose of this in vitro study was to compare marginal fits of CAD-CAM crowns fabricated after initial preparation with loupes and subsequent preparation refinement with either loupes or a microscope. The null hypothesis was that no significant difference would be found in the marginal gap between the preparations with loupes and those with a microscope.Mounted extracted molars (N=18) received initial crown preparations with a coarse grit, rounded shoulder, diamond rotary instrument with loupes of ×3.0 magnification. The teeth were then randomly divided into 2 groups and refined for an additional 2 minutes with fine grit, rounded shoulder, diamond rotary instruments with either loupes (LOUP) or a microscope up to ×10.0 magnification (DOM). The prepared teeth were scanned with an intraoral scanner to fabricate zirconia-reinforced lithium silicate crowns manufactured with a 4-axis milling machine, sintered in a dental furnace in accordance with the manufacturer's instructions, and cemented with self-adhesive resin cement. All teeth with crowns were mounted and scanned with a microcomputed tomography (μCT) system at 21-μm nominal voxel size. The resulting Digital Imaging and Communications in Medicine (DICOM) images were imported into a semiautomatic segmentation software program. Marginal and absolute gaps were measured at 24 consistent circumferential points per specimen. Absolute gaps were labeled, and the total volume was calculated. Paired and unpaired t tests were used for statistical analysis (α=.05).The mean marginal gap was 145.0 ±259.6 μm for LOUP and 35.6 ±110.6 μm for DOM, with a statistically significant difference (P.001). The mean gap volume for LOUP was 0.975 ±0.811 mmThis study demonstrated that the higher magnification used during tooth preparation played a significant role in the size of marginal gaps present around CAD-CAM crowns. Crown preparations finished by using fine grit diamond rotary instruments with a microscope at higher magnification than loupes resulted in a more precise marginal fit with smaller gaps.
- Published
- 2021
9. Coupling Raman, Brillouin and Nd
- Author
-
Michael, Bergler, Kristian, Cvecek, Ferdinand, Werr, Alexander, Veber, Julia, Schreiner, Udo R, Eckstein, Kyle G, Webber, Michael, Schmidt, and Dominique, de Ligny
- Subjects
uniaxial stress ,fictive temperature ,glass structure ,Raman spectroscopy ,Brillouin spectroscopy ,cooling rate ,window glass ,Article ,soda–lime silicate glass - Abstract
Evolution of spectroscopic properties of a soda–lime silicate glass with different thermal history and under applied uniaxial stress was investigated using Raman and Brillouin spectroscopies as well as Nd3+ photoluminescence techniques. Samples of soda–lime silicate with a cooling rate from 6 × 10−4 to 650 K/min were prepared either by controlled cooling from the melt using a differential scanning calorimeter or by a conventional annealing procedure. Uniaxial stress effects in a range from 0 to −1.3 GPa were investigated in situ by compression of the glass cylinders. The spectroscopic observations of rearrangements in the network structure were related to the set cooling rates or the applied uniaxial stress to calculate an interrelated set of calibrations. Comparing the results from Raman and Brillouin spectroscopy with Nd3+ photoluminescence analysis, we find a linear dependence that can be used to identify uniaxial stress and cooling rate in any given combination concurrently. The interrelated calibrations and linear dependence models are established and evaluated, and equations relating the change of glass network due to effects of cooling rate or uniaxial stress are given.
- Published
- 2021
10. A novel digital approach for fixed full-mouth implant-supported rehabilitations : a case report
- Author
-
Arturo Llobell, Jonathan Korostoff, Michael Bergler, Howard P. Fraiman, Caleb Cross, and Joseph P. Fiorellini
- Subjects
Orthodontics ,Fixed prosthesis ,Prosthetic Dentistry ,Rehabilitation ,Dentition ,Gingival tissue ,Computer science ,Technician ,medicine.medical_treatment ,Case Report ,CIENCIAS MÉDICAS [UNESCO] ,Prosthesis ,Entire dentition ,UNESCO::CIENCIAS MÉDICAS ,medicine ,General Dentistry ,Implant supported - Abstract
Successful rehabilitation of a patient's entire dentition with implant-supported fixed prostheses requires restoration of function, esthetics and comfort. To achieve this goal, the clinician and laboratory technician must work in concert with one another to navigate the multiple steps from the patient's initial evaluation to delivery of the final prostheses. Key to this is the ability of the clinician to provide the technician with detailed information regarding the patient's extra- and intraoral characteristics in a manner that can be easily and accurately transferred to the lab bench where it then serves as the foundation for reconstruction of the dentition. In recent years, the impressive evolution of digital technology in dentistry has dramatically facilitated this complex process. The aim of this case report is to illustrate how digital profiles of a patient's facial and intraoral features can be merged with one another and used to generate artificial teeth and gingival tissue of a full mouth implant supported rehabilitation via computer-aided design and computer-aided manufacturing (CAD/CAM) technology to successfully rehabilitate a patient that initially presented with a terminal dentition. Key words:Facial scan, Zirconia, Implant-supported rehabilitation, Implant-supported prosthesis, Fixed prosthesis, Oral rehabilitation.
- Published
- 2020
11. Correlation between mechanical and structural properties as a function of temperature within the TeO2–TiO2–ZnO ternary system
- Author
-
Maggy Dutreilh-Colas, Dominique de Ligny, Michael Bergler, J. de Clermont-Gallerande, Philippe Thomas, Tomokatsu Hayakawa, F. Célarié, Yann Gueguen, Institut de Recherche sur les CERamiques (IRCER), Institut des Procédés Appliqués aux Matériaux (IPAM), Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), Axe 3 : organisation structurale multiéchelle des matériaux (SPCTS-AXE3), Science des Procédés Céramiques et de Traitements de Surface (SPCTS), Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM)-Institut des Procédés Appliqués aux Matériaux (IPAM), Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM), Institut de Physique de Rennes (IPR), Université de Rennes 1 (UR1), Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Centre National de la Recherche Scientifique (CNRS), Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Nagoya Institute of Technology (NIT), Conseil Régional du Limousin, Pacific Institute for Climate Solutions, Department of Materials Science and Engineering, Nagoya Institute of Technology, IRCER - Axe 3 : organisation structurale multiéchelle des matériaux (IRCER-AXE3), Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Institut des Procédés Appliqués aux Matériaux (IPAM), Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut des Procédés Appliqués aux Matériaux (IPAM), Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut des Procédés Appliqués aux Matériaux (IPAM), and Université de Rennes (UR)-Centre National de la Recherche Scientifique (CNRS)
- Subjects
Optical fiber ,Materials science ,Thermodynamics ,02 engineering and technology ,Viscous liquid ,01 natural sciences ,law.invention ,[PHYS.MECA.MEMA]Physics [physics]/Mechanics [physics]/Mechanics of materials [physics.class-ph] ,symbols.namesake ,law ,0103 physical sciences ,Materials Chemistry ,ComputingMilieux_MISCELLANEOUS ,010302 applied physics ,[PHYS]Physics [physics] ,Ternary numeral system ,Relaxation (NMR) ,[CHIM.MATE]Chemical Sciences/Material chemistry ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,Electronic, Optical and Magnetic Materials ,Calorimeter ,Brillouin zone ,Ceramics and Composites ,symbols ,0210 nano-technology ,Glass transition ,Raman spectroscopy - Abstract
International audience; In situ Raman spectroscopy, Resonance Frequency and Damping Analysis (RFDA) setup and Associated Raman Brillouin Calorimeter (ARABICA) setup experiments as a function of temperature were conducted on the (100-x)TeO2-5TiO2-xZnO (x=15; 17.5; 20; 22.5; 25) glass system. Structural and mechanical properties showed non-conventional properties evolution as a function of ZnO content which are managed by the modification of ZnO polyhedra. Before glass transition temperature (Tg), the evolution of the Boson peak (BP) frequencies and the elastic properties are in accordance with the idea of the relaxation of the strains inside the glass; after Tg, their evolution shows the transition toward a viscous liquid. BP and mechanical properties study evidences that as nano-heterogeneous domains size increases at a faster rate, the mechanical properties will decrease at a slower rate. This point will be helpful for choosing appropriate composition for optical fiber shaping.
- Published
- 2020
- Full Text
- View/download PDF
12. Corrigendum: Cooling rate calibration and mapping of ultra-short pulsed laser modifications in fused silica by Raman and Brillouin spectroscopy
- Author
-
Michael Bergler, Kristian Cvecek, Ferdinand Werr, Martin Brehl, Dominique de Ligny, and Michael Schmidt
- Subjects
Industrial and Manufacturing Engineering - Published
- 2020
- Full Text
- View/download PDF
13. Surface Probing of Ultra‐Short‐Pulse Laser Filament Cut Window Glass and the Impact on the Separation Behavior
- Author
-
Ludger Müllers, Michael Bergler, Ferdinand Werr, Martin Brehl, Dominique de Ligny, Dirk Werner, Eppelt Urs, and Alexander Veber
- Subjects
Surface (mathematics) ,Materials science ,business.industry ,Laser cutting ,Separation (aeronautics) ,Window (computing) ,Condensed Matter Physics ,Laser ,law.invention ,Protein filament ,Optics ,law ,General Materials Science ,business ,Ultra short pulse - Published
- 2020
- Full Text
- View/download PDF
14. Glass Machining and In-situ Metrology: recovery of spatio-temporal phase distribution from 2-dimensional interference fringe movement caused by irradiation of glass with ultra-short laser pulses at high pulse repetition rates
- Author
-
Kristian Cvecek, Johannes Heberle, Michael Bergler, Isamu Miyamoto, Dominique De Ligny, and Michael Schmidt
- Published
- 2019
- Full Text
- View/download PDF
15. Sr[Li
- Author
-
Gregor J, Hoerder, Markus, Seibald, Dominik, Baumann, Thorsten, Schröder, Simon, Peschke, Philipp C, Schmid, Tobias, Tyborski, Philipp, Pust, Ion, Stoll, Michael, Bergler, Christian, Patzig, Stephan, Reißaus, Michael, Krause, Lutz, Berthold, Thomas, Höche, Dirk, Johrendt, and Hubert, Huppertz
- Subjects
Inorganic LEDs ,Solid-state chemistry ,Article - Abstract
Innovative materials for phosphor converted white light-emitting diodes are in high demand owing to the huge potential of the light-emitting diode technology to reduce energy consumption worldwide. As the primary blue diode is already highly optimized, the conversion phosphors are of crucial importance for any further improvements. We report on the discovery of the high performance red phosphor Sr[Li2Al2O2N2]:Eu2+ meeting all requirements for a phosphor’s optical properties. It combines the optimal spectral position for a red phosphor, as defined in the 2016 Research & Development-plan of the United States government, with an exceptionally small spectral full width at half maximum and excellent thermal stability. A white mid-power phosphor-converted light-emitting diode prototype utilising Sr[Li2Al2O2N2]:Eu2+ shows an increase of 16% in luminous efficacy compared to currently available commercial high colour-rendering phosphor-converted light-emitting diodes, while retaining excellent high colour rendition. This phosphor enables a big leap in energy efficiency of white emitting phosphor-converted light-emitting-diodes., Developing innovative materials for reduced energy consumption in phosphor converted white light-emitting diodes remains a challenge. Here, the authors report a narrow band red-emitting oxonitride material with a highly symmetrical Sr2 + coordination for energy efficient white light-emitting diodes.
- Published
- 2018
16. Effect of thermally induced structural disorder on the chemical durability of International Simple Glass
- Author
-
Dominique de Ligny, Alexander Veber, Michael Bergler, Hong Li, Frédéric Angeli, Thibault Charpentier, Patrick Jollivet, Stéphane Gin, Laboratoire d'Etudes du Comportement à Long Terme des matériaux de conditionnement (LCLT), Département de recherche sur les Procédés et Matériaux pour les Environnements complexes (DPME), CEA-Direction des Energies (ex-Direction de l'Energie Nucléaire) (CEA-DES (ex-DEN)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-CEA-Direction des Energies (ex-Direction de l'Energie Nucléaire) (CEA-DES (ex-DEN)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA), Laboratoire Structure et Dynamique par Résonance Magnétique (LCF) (LSDRM), Nanosciences et Innovation pour les Matériaux, la Biomédecine et l'Energie (ex SIS2M) (NIMBE UMR 3685), Institut Rayonnement Matière de Saclay (IRAMIS), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Institut Rayonnement Matière de Saclay (IRAMIS), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), Institute of Ceramics and Glass, Nippon Electric Glass, CEA, ORANO and EDF, Département de recherche sur les technologies pour l'enrichissement, le démantèlement et les déchets (DE2D), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)-Institut Rayonnement Matière de Saclay (IRAMIS), and Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)-Institut de Chimie du CNRS (INC)
- Subjects
Materials science ,Materials Science (miscellaneous) ,Oxide ,Context (language use) ,02 engineering and technology ,01 natural sciences ,chemistry.chemical_compound ,symbols.namesake ,0103 physical sciences ,Materials Chemistry ,lcsh:TA401-492 ,010302 applied physics ,Quenching ,Aqueous solution ,Borosilicate glass ,[CHIM.MATE]Chemical Sciences/Material chemistry ,021001 nanoscience & nanotechnology ,Durability ,Silicate ,chemistry ,Chemical engineering ,13. Climate action ,Chemistry (miscellaneous) ,Ceramics and Composites ,symbols ,lcsh:Materials of engineering and construction. Mechanics of materials ,0210 nano-technology ,Raman spectroscopy - Abstract
While the influence of silicate oxide glass composition on its chemical durability is increasingly known, the contribution of structure only is less well understood, yet is crucial for an accurate description of aqueous alteration mechanisms. The effect of structural disorder can be investigated by varying the thermal history of the glass. Furthermore, the structural changes generated by self-irradiation in nuclear glasses can be compared with those induced by fast quenching. In the context of deep geological disposal of vitreous matrices, it is then challenging to address the structural impact on glass durability. Here, a borosilicate glass, the International Simple Glass, was fiberized to obtain a rapidly quenched sample. The quenching rate and fictive temperature were evaluated from in situ Raman and Brillouin spectroscopies. Multinuclear nuclear magnetic resonance was used to obtain insight into the effect of quenching on the pristine and altered glass structure. Higher bond angle distribution and lower mixing of alkalis were observed in the fast quenched glass. Some of AlO4 groups are then Ca-compensated, while a part of BO4 is transformed into BO3 units. The structural modifications increase the hydrolysis of the silicate network occurring in the forward rate regime at 90 °C by a factor of 1.4–1.8 depending on the pH value. Residual rate regime is similarly affected, more significantly at the beginning of the experiments conducted in silica saturated solutions. These findings prove that the reactivity of glass remains controlled by its structure under the various alteration regimes. The structural changes induced by the rapid quenching of borosilicate glasses and their effects on chemical durability have been studied. Understanding how, and how fast, borosilicate glasses degrade is of great importance because they are often used as containment matrices for the disposal of radioactive waste. However, understanding how glass structure affects durability can be troublesome because both structural and compositional factors must be accounted for and are difficult to deconvolute. Now, a team, led by Frederic Angeli at the CEA, Marcoule, France, have shown, using various spectroscopic techniques, how the effects of structural disorder can be investigated by varying the thermal history of a glass. The results show that this methodology can be used to investigate radiation damage in nuclear glasses, the effects of which are similar to those of quenching.
- Published
- 2018
- Full Text
- View/download PDF
17. Zirconia Abutments for Single-Tooth Implants—Rationale and Clinical Guidelines
- Author
-
Michael S. Block, Michael Bergler, Stefan Holst, and Markus B. Blatz
- Subjects
Adult ,Abutment ,Dentistry ,Dental Abutments ,Dental Implants, Single-Tooth ,Dental porcelain ,Maxilla ,Dental Prosthesis Design ,Humans ,Medicine ,Cementation ,Crowns ,business.industry ,Dental prosthesis ,Single tooth ,Dental Porcelain ,Incisor ,Otorhinolaryngology ,Practice Guidelines as Topic ,Computer-Aided Design ,Female ,Surgery ,Dental Prosthesis, Implant-Supported ,Zirconium ,Implant ,Oral Surgery ,business ,Single tooth implant - Abstract
Clinical success of an endosseous implant to replace a single tooth is not only defined by its survival. Esthetic parameters have become integral aspects in defining success and failure. All-ceramic abutments have started to play a major role in achieving an esthetically successful result. The material itself, however, is not the exclusive determinant for esthetic success. It is the appropriate design and proper handling of the material and the abutment that enables the clinician to achieve esthetic outcomes that were not possible with traditional metal alloys. This article explores the rationale for using zirconia for prosthetic implant components, explains specific material properties, and discusses strategies and guidelines for the design and successful clinical implementation of CAD/CAM-fabricated zirconia implant abutments.
- Published
- 2009
- Full Text
- View/download PDF
18. Clinical application of a new self-adhesive resin cement for zirconium-oxide ceramic crowns
- Author
-
Markus B, Blatz and Michael, Bergler
- Subjects
Incisor ,Young Adult ,Crowns ,Dental Prosthesis Design ,Dental Cements ,Humans ,Female ,Zirconium ,Esthetics, Dental - Published
- 2014
19. Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling
- Author
-
Markus B, Blatz, Michael, Bergler, Fusun, Ozer, Stefan, Holst, Jin-Ho, Phark, and Gerard J, Chiche
- Subjects
Dental Stress Analysis ,Time Factors ,Potassium Compounds ,Surface Properties ,Dental Bonding ,Metal Ceramic Alloys ,Temperature ,Sodium Chloride ,Dental Porcelain ,Dental Materials ,Dental Veneers ,Gold Alloys ,Humans ,Aluminum Silicates ,Yttrium ,Stress, Mechanical ,Zirconium ,Shear Strength - Abstract
To evaluate the bond strength of recently developed feldspathic veneering ceramics to zirconium-oxide ceramic core material (Y-TZP). In addition, the effect of thermocycling on the bond strength was investigated.90 square Lava framework Y-TZP specimens were randomly assigned to three groups (n = 30) and veneered with one of the three zirconia veneering ceramics Cerabien ZR (CZR), GC Initial (GCI), or Lava Ceram (LC). 30 additional metal-ceramic specimens served as the control (VO). 15 specimens per group were stored in a saline solution for 3 days. To test the durability of the bond, 15 specimens per group were thermocycled for 10,000 cycles between 5 degrees to 60 degrees C with a 15-second dwell time. Shear strength was tested with an Instron universal testing system. A two-way ANOVA model and Tukey's HSD were applied for statistical analyses (alpha = 0.05).The different material combinations revealed significantly different shear bond strength values (CZRGCILCVO). All veneering ceramic/zirconia combinations showed significantly higher bond strength than the metal-ceramic control VO. Bond strength values were not affected by thermocycling, except for CZR, which had significantly higher bond strength after thermocycling. Microscopic evaluation of failure modes revealed 100% cohesive failures in the veneering ceramic for all specimens.
- Published
- 2011
20. CAD/CAM and telescopic technology: design options for implant-supported overdentures
- Author
-
Michael, Bergler, Stefan, Holst, Markus B, Blatz, Stephan, Eitner, and Manfred, Wichmann
- Subjects
Models, Anatomic ,Crowns ,Dental Implantation, Endosseous ,Maxillary Sinus ,Middle Aged ,Denture, Overlay ,Dental Porcelain ,Dental Prosthesis Design ,Surgery, Computer-Assisted ,Computer-Aided Design ,Humans ,Female ,Dental Prosthesis, Implant-Supported ,Zirconium ,Oral Surgical Procedures, Preprosthetic ,Dental Alloys - Abstract
There are many options with respect to materials, construction methods, and design concepts for the technical implementation of implant-supported dental prostheses. Different methods of anchorage can be used to attach removable superstructures to implants. Telescopic crowns make it possible to fabricate inexpensive superstructures with precise and passive fit. Computer-aided design/computer-assisted manufacture (CAD/CAM) technology allows copings to be fabricated from materials such as zirconia or titanium. Moreover, CAD/CAM crown copings can serve as a base for fabricating customized ceramic replacement teeth. Different veneering techniques, such as pressed-on ceramics for zirconia cores, ensure a fast and economic work process. With the use of electroforming it is possible to manufacture highly precise secondary structures that ensure passive seating of the prosthesis in a stable position. This article demonstrates a restorative treatment option using current techniques with the aim of rehabilitation with an esthetic and functional implant-supported removable denture.
- Published
- 2009
21. Influence of impression material and time on the 3-dimensional accuracy of implant impressions
- Author
-
Stefan, Holst, Markus B, Blatz, Michael, Bergler, Matthias, Goellner, and Manfred, Wichmann
- Subjects
Dental Implants ,Dental Impression Technique ,Time Factors ,Dental Prosthesis Design ,Siloxanes ,Dental Impression Materials ,Polyvinyls ,Models, Dental ,Statistics, Nonparametric ,Ethers - Abstract
To investigate, in vitro, the effect of time on the 3-dimensional accuracy of open-tray implant impression copings made of polyvinyl siloxane and polyether impression materials.Reference models with 4 internal connection implants were fabricated. Four sets of 71 direct impressions were made with square impression copings using an open-tray technique. One set of impressions was made with polyether material (material A) and each of 3 polyvinyl siloxane materials (materials B, C, and D). Three-dimensional changes in spatial orientation of the implant analogs were measured over 48 hours using an optical measurement device. Deviation values were summed over 4 points and averaged per impression. Global differences were tested with a nonparametric Kruskal-Wallis test followed by pairwise comparisons using the Mann-Whitney U test.The mean dimensional accuracy of implant impressions significantly differed over time (P.001). Materials A and B were found to produce comparable results, For materials C and D there was a significant increase in deviations, with a maximum increase at 2 hours. Deviations for material C were comparable to materials A and B at 48 hours. Baseline values were not maintained by any material.Within the limits of this in vitro study, it can be concluded that time cannot be neglected as a factor affecting the accuracy of implant master casts.
- Published
- 2007
22. Zahnärztliche Implantologie unter schwierigen Umständen
- Author
-
Eleftherios Vairaktaris, Andreas Schlegel, Peter Kessler, Emeka Nkenke, Stephan Rupprecht, Jörg Wiltfang, Michael Bergler, Stefan Schultze-Mosgau, Friedrich Wilhelm Neukam, and Manfred Wichmann
- Published
- 2007
- Full Text
- View/download PDF
23. Application of interim fixed reference points to maintain the occlusal vertical dimension: a technique for immediate loading protocols in the edentulous mandible
- Author
-
Manfred Wichmann, Markus B. Blatz, Stefan Holst, and Michael Bergler
- Subjects
Dental Implants ,Vertical dimension of occlusion ,Dental Articulators ,Dental Impression Technique ,Computer science ,business.industry ,Implant dentistry ,Bone Screws ,Dental Implantation, Endosseous ,Edentulous mandible ,Acrylic Resins ,Dentistry ,Vertical Dimension ,Mandible ,Models, Dental ,Jaw Relation Record ,Immediate loading ,Interim ,Humans ,Jaw, Edentulous ,Oral Surgery ,business ,Denture Design ,Edentulous patient - Abstract
This article describes a technique for the clinical insertion and use of specially designed screws as fixed intraoral reference and attachment points in implant dentistry. After insertion, these screws serve to stabilize radiographic and surgical templates in the completely edentulous patient. This approach provides the advantage of guiding maintenance of the correct occlusal vertical dimension and ensuring accuracy and stability during subsequent phases of treatment.
- Published
- 2006
24. Implant-supported prosthetic treatment in cases with hard- and soft-tissue defects
- Author
-
Stefan, Holst, Markus B, Blatz, Michael, Bergler, Manfred, Wichmann, and Stephan, Eitner
- Subjects
Male ,Soft Tissue Injuries ,Gingiva ,Maxilla ,Humans ,Jaw, Edentulous ,Female ,Dental Prosthesis, Implant-Supported - Abstract
Tooth loss due to trauma or periodontal disease is often associated with extensive deficiencies of the supporting hard and soft tissues and atrophy of the alveolar ridges. The functional and esthetic predictability of an implant-supported prosthetic restoration in patients with extensive tissue augmentation is guarded, even when lost tissues were restored at an early stage by local ridge augmentation. The prosthetic reconstruction of major tissue defects is especially difficult, as lost structures of the alveolar ridge must be replaced by the restoration, which is expected to provide optimal function and esthetics, yet allow for optimal oral hygiene. This article presents prosthetic solutions for replacing missing hard and soft tissues with implant-supported fixed and removable restorations in cases of severe tissue deficiencies.
- Published
- 2005
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.