17 results on '"McNamara EA"'
Search Results
2. Some Lessons Learned for Kidney Failure Patients in the COVID-19 Pandemic.
- Author
-
Kliger AS, Silberzweig J, McNamara EA, and Stark S
- Subjects
- Humans, Renal Insufficiency therapy, Pandemics, Renal Dialysis, COVID-19 epidemiology, COVID-19 complications, SARS-CoV-2
- Published
- 2023
- Full Text
- View/download PDF
3. Genetic counseling for women with 45,X/46,XX mosaicism: Towards more personalized management.
- Author
-
Snyder EA, San Roman AK, Piña-Aguilar RE, Steeves MA, McNamara EA, Souter I, Hayes FJ, Levitsky LL, and Lin AE
- Subjects
- 46, XX Disorders of Sex Development diagnosis, Cells, Cultured, Female, Genetic Testing standards, Humans, Karyotyping standards, Precision Medicine standards, Turner Syndrome diagnosis, 46, XX Disorders of Sex Development genetics, Genetic Testing methods, Karyotyping methods, Mosaicism, Phenotype, Precision Medicine methods, Turner Syndrome genetics
- Abstract
Despite numerous clinical series, consistent karyotype-phenotype correlations for Turner syndrome have not been established, although a lower level of 45,X is generally thought to be associated with a milder phenotype. This limits personalized counseling for women with 45,X/46,XX mosaicism. To better understand the phenotypic spectrum associated with various levels of 45,X/46,XX mosaicism, we compared patients evaluated in the Massachusetts General Hospital Turner Syndrome Clinic to determine if cardiac, renal, and thyroid abnormalities correlated with the percentage of 45,X cells present in a peripheral blood karyotype. of the 118 patients included in the study, 78 (66%) patients had non-mosaic 45,X and 40 (34%) patients had varying levels of 45,X/46,XX mosaicism. Patients with ≤70% 45,X compared with those with >70% 45,X had a significantly lower frequency of cardiac and renal anomalies. The presence of hypothyroidism was somewhat lower for the ≤70% 45,X group, but was not statistically significant. Supplemental tissue testing on another tissue type, typically buccal mucosa, was often useful in counseling patients with 45,X mosaicism. Given the modest sample size of patients with varying levels of mosaicism and the variability of Turner syndrome abnormalities, we hope this preliminary study will inspire a multicenter collaboration, which may lead to modification of clinical guidelines. Because several patients with ≤70% 45,X were ascertained from perinatal care referrals, we still advise women with 45,X mosaicism pursuing pregnancy to receive standard Turner syndrome cardiac surveillance. There is an opportunity to personalize counseling and surveillance for patients based on percentage of 45,X cells on chromosome analysis., (Copyright © 2021 Elsevier Masson SAS. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
4. Effect of Positioning of the Region of Interest on Bone Density of the Hip.
- Author
-
Feit A, Levin N, McNamara EA, Sinha P, Whittaker LG, Malabanan AO, and Rosen HN
- Subjects
- Aged, Female, Hip diagnostic imaging, Humans, Male, Middle Aged, Absorptiometry, Photon methods, Bone Density, Femur diagnostic imaging, Image Processing, Computer-Assisted methods
- Abstract
Background: Large changes in positioning of the global region of interest (ROI) influence the measurement of bone mineral density (BMD) in the hip and forearm regions. However, it is unknown whether minor shifts in the positioning of the bottom of the global hip ROI affect the measurement of total hip BMD., Methods: The hip BMDs of 40 clinical densitometry patients were analyzed at baseline with the bottom of the global hip ROI positioned as usual, 10 mm distal to the base of the lesser trochanter (position 0). Then the hip was reanalyzed by shifting the bottom of the global hip ROI 1 mm proximally 10 times (positions +1 through +10) and then by shifting the bottom of the global hip ROI 1 mm distally 10 times (positions -1 through -10). The significance of the differences between mean values at the various distances from baseline was assessed using a Wilcoxon signed-rank test., Results: The mean total hip area, bone mineral content and BMD decreased as the bottom of the global hip ROI was shifted proximally; the decrease was significant when shifted by even 1 mm (p < 0.001). The mean total hip area, bone mineral content and BMD increased as the bottom of the global hip ROI was shifted distally; the increase was significant when shifted by even 1 mm (p < 0.001). The change in BMD with each 1 mm shift was uniform across the range studied from positions +10 through -10, and was approx 0.54%/mm. When the least significant change was based on 40 pairs of measurements, where each pair was comprised of the baseline scan and the same scan at -1 position, the least significant change was 0.01 g/cm
2 ., Conclusions: The BMD of the total hip is sensitive to even minor changes in the positioning of the bottom of the global hip ROI. Although a 1 mm change in the bottom of the global hip ROI positioning would make little difference in the reported T-score, it could easily affect the determination of significance in changes in BMD over time., (Copyright © 2019 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)- Published
- 2020
- Full Text
- View/download PDF
5. Further Delineation of Liver Involvement in Girls and Women with Turner Syndrome: Case Report of a 2-Year-Old with Liver Dysfunction and Review of Patients Followed in the MassGeneral Hospital Turner Syndrome Clinic.
- Author
-
Jafri RZ, McNamara EA, Snyder EA, Shah U, Singh I, Hayes FJ, Lin AE, and Levitsky LL
- Subjects
- Adolescent, Adult, Child, Child, Preschool, Female, Follow-Up Studies, Humans, Liver Function Tests, Estrogen Replacement Therapy, Liver Diseases blood, Liver Diseases pathology, Liver Diseases therapy, Turner Syndrome blood, Turner Syndrome pathology, Turner Syndrome therapy
- Abstract
Background: Liver function test (LFT) abnormalities, which may reflect underlying pathophysiology, are a well-known feature of Turner syndrome. Less frequently, liver findings may include vascular changes and, rarely, severe liver disease. Although previous studies on children and adolescents suggest a frequency of LFT abnormalities of up to 60%, less is known about the age at onset and natural history., Methods: We report a now 19-year-old young woman with Turner syndrome mosaicism with elevated transaminase levels first detected at the age of 2 years. We also present a retrospective analysis of 179 girls and women followed in the MassGeneral Hospital Turner Syndrome Clinic., Results: In the index case, the severity of liver function test abnormalities fluctuated without complete resolution from 2 to 18 years of age. In the full cohort of 179 patients, when lab results were available, elevated ALT levels occurred in 16 (11%) subjects of all ages, and in 5 (10%) patients ≤18 years of age. Significant and persistent ALT elevations occurred in 2 patients <10 years of age., Conclusion: The updated Clinical Practice Guidelines for the care of girls and women with Turner syndrome recommend annual liver function tests throughout the lifespan, starting at the age of 10 years. Based on our data showing persistent elevation of at least one liver enzyme, we recommend a prospective and more comprehensive study of liver function in younger patients with Turner syndrome. An improved estimate of prevalence could better inform age-adjusted guidelines., (© 2019 S. Karger AG, Basel.)
- Published
- 2019
- Full Text
- View/download PDF
6. Dual diagnoses in 152 patients with Turner syndrome: Knowledge of the second condition may lead to modification of treatment and/or surveillance.
- Author
-
Jones KL, McNamara EA, Longoni M, Miller DE, Rohanizadegan M, Newman LA, Hayes F, Levitsky LL, Herrington BL, and Lin AE
- Subjects
- Adult, Child, Child, Preschool, Female, Humans, Turner Syndrome complications, Population Surveillance, Turner Syndrome diagnosis, Turner Syndrome therapy
- Abstract
Turner syndrome is a sex chromosome abnormality in which a female has a single X chromosome or structurally deficient second sex chromosome. The phenotypic spectrum is broad, and atypical features prompt discussion of whether the known features of Turner syndrome should be further expanded. With the advent of clinical whole exome sequencing, there has been increased realization that some patients with genetic disorders carry a second genetic disorder, leading us to hypothesize that a "dual diagnosis" may be more common than suspected for Turner syndrome. We report five new patients with Turner syndrome and a co-occurring genetic disorder including one patient with Li-Fraumeni syndrome, Li-Fraumeni and Noonan syndrome, mosaic trisomy 8, pathogenic variant in RERE, and blepharophimosis-ptosis-epicanthanus inversus syndrome. We also undertook an extensive literature review of 147 reports of patients with Turner syndrome and a second genetic condition. A total of 47 patients (31%) had trisomy 21, followed by 36 patients (24%) had one of 11 X-linked disorders. Notably, 80% of the 147 reported patients with a dual diagnosis had mosaicism for Turner syndrome, approximately twice the frequency in the general Turner syndrome population. This article demonstrates the potential for co-occurring syndromes in patients with Turner syndrome, prompting us to recommend a search for an additional genetic disorder in Turner patients with unusual features. Knowledge of the second condition may lead to modification of treatment and/or surveillance. We anticipate that increased awareness and improved diagnostic technologies will lead to the identification of more cases of Turner syndrome with a co-occurring genetic syndrome., (© 2018 Wiley Periodicals, Inc.)
- Published
- 2018
- Full Text
- View/download PDF
7. Effect of Positioning of the ROI on BMD of the Forearm and Its Subregions.
- Author
-
Rosen EO, McNamara EA, Whittaker LG, Malabanan AO, and Rosen HN
- Subjects
- Aged, Female, Forearm physiology, Humans, Middle Aged, Absorptiometry, Photon methods, Bone Density physiology, Forearm diagnostic imaging, Patient Positioning
- Abstract
Inconsistent positioning of patients and region of interest (ROI) is known to influence the precision of bone mineral density (BMD) measurements in the spine and hip. However, it is unknown whether minor shifts in the positioning of the ROI along the shaft of the radius affect the measurement of forearm BMD and its subregions. The ultradistal (UD-), mid-, one-third, and total radius BMDs of 50 consecutive clinical densitometry patients were acquired. At baseline the distal end of the ROI was placed at the tip of the ulnar styloid as usual, and then the forearm was reanalyzed 10 more times, each time shifting the ROI 1 mm proximally. No corrections for multiple comparisons were necessary since the differences that were significant were significant at p < 0.001. The UD-radius BMD increased as the ROI was shifted proximally; the increase was significant when shifted even 1 mm proximally (p < 0.001). These same findings held true for the mid- and total radius bone density, though the percent increase with moving proximally was significantly greater for the UD radius than for the other subregions. However, there was no significant change in the one-third radius BMD when shifted proximally 1-10 mm. Minor proximal shifts of the forearm ROI substantially affect the BMD of the UD-, mid- and total radius, while having no effect on the one-third radius BMD. Since the one-third radius is the only forearm region usually reported, minor proximal shifts of the ROI should not influence forearm BMD results significantly., (Copyright © 2018 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
8. Direct Comparison of the Precision of the New Hologic Horizon Model With the Old Discovery Model.
- Author
-
Whittaker LG, McNamara EA, Vath S, Shaw E, Malabanan AO, Parker RA, and Rosen HN
- Subjects
- Absorptiometry, Photon methods, Aged, Clinical Competence, Forearm diagnostic imaging, Hip diagnostic imaging, Humans, Middle Aged, Spine diagnostic imaging, Statistics, Nonparametric, Absorptiometry, Photon instrumentation, Absorptiometry, Photon standards, Bone Density physiology
- Abstract
Previous publications suggested that the precision of the new Hologic Horizon densitometer might be better than that of the previous Discovery model, but these observations were confounded by not using the same participants and technologists on both densitometers. We sought to study this issue methodically by measuring in vivo precision in both densitometers using the same patients and technologists. Precision studies for the Horizon and Discovery models were done by acquiring spine, hip, and forearm bone mineral density twice on 30 participants. The set of 4 scans on each participant (2 on the Discovery, 2 on the Horizon) was acquired by the same technologist using the same scanning mode. The pairs of data were used to calculate the least significant change according to the International Society for Clinical Densitometry guidelines. The significance of the difference between least significant changes was assessed using a Wilcoxon signed-rank test of the difference between the mean square error of the absolute value of the differences between paired measurements on the Discovery (Δ-Discovery) and the mean square error of the absolute value of the differences between paired measurements on the Horizon (Δ-Horizon). At virtually all anatomic sites, there was a nonsignificant trend for the precision to be better for the Horizon than for the Discovery. As more vertebrae were excluded from analysis, the precision deteriorated on both densitometers. The precision between densitometers was almost identical when reporting only 1 vertebral body. (1) There was a nonsignificant trend for greater precision on the new Hologic Horizon compared with the older Discovery model. (2) The difference in precision of the spine bone mineral density between the Horizon and the Discovery models decreases as fewer vertebrae are included. (3) These findings are substantially similar to previously published results which had not controlled as well for confounding from using different subjects and technologists., (Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
9. Enhanced Precision of the New Hologic Horizon Model Compared With the Old Discovery Model Is Less Evident When Fewer Vertebrae Are Included in the Analysis.
- Author
-
McNamara EA, Kilim HP, Malabanan AO, Whittaker LG, and Rosen HN
- Subjects
- Absorptiometry, Photon standards, Adult, Aged, Female, Humans, Male, Middle Aged, Practice Guidelines as Topic, Reproducibility of Results, Absorptiometry, Photon instrumentation, Bone Density, Lumbar Vertebrae diagnostic imaging
- Abstract
The International Society for Clinical Densitometry guidelines recommend using locally derived precision data for spine bone mineral densities (BMDs), but do not specify whether data derived from L1-L4 spines correctly reflect the precision for spines reporting fewer than 4 vertebrae. Our experience suggested that the decrease in precision with successively fewer vertebrae is progressive as more vertebrae are excluded and that the precision for the newer Horizon Hologic model might be better than that for the previous model, and we sought to quantify. Precision studies were performed on Hologic densitometers by acquiring spine BMD in fast array mode twice on 30 patients, according to International Society for Clinical Densitometry guidelines. This was done 10 different times on various Discovery densitometers, and once on a Horizon densitometer. When 1 vertebral body was excluded from analysis, there was no significant deterioration in precision. When 2 vertebrae were excluded, there was a nonsignificant trend to poorer precision, and when 3 vertebrae were excluded, there was significantly worse precision. When 3 or 4 vertebrae were reported, the precision of the spine BMD measurement was significantly better on the Hologic Horizon than on the Discovery, but the difference in precision between densitometers narrowed and was no longer significant when 1 or 2 vertebrae were reported. The results suggest that (1) the measurement of in vivo spine BMD on the new Hologic Horizon densitometer is significantly more precise than on the older Discovery model; (2) the difference in precision between the Horizon and Discovery models decreases as fewer vertebrae are included; (3) the measurement of spine BMD is less precise as more vertebrae are excluded, but still quite reasonable even when only 1 vertebral body is included; and (4) when 3 vertebrae are reported, L1-L4 precision data can reasonably be used to report significance of changes in BMD. When 1 or 2 vertebrae are reported, precision data for 1 or 2 vertebrae, respectively, should be used, because the exclusion of 2-3 vertebrae significantly worsens precision., (Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
10. Cleaning practices in the hospital setting: Are high-touch surfaces in isolation and standard precaution patient rooms cleaned to the same standard?
- Author
-
Zelikoff AJ, Dellit TH, Lynch J, McNamara EA, and Makarewicz VA
- Subjects
- Health Services Research, Hospitals, Humans, Disinfection methods, Environmental Microbiology, Housekeeping, Hospital methods, Patients' Rooms
- Abstract
The purpose of this quality improvement project was to identify differences in cleaning practices between isolation rooms and standard precaution rooms in the hospital setting. An ultravoilet marking system was used to evaluate high-touch surfaces throughout the patient environment. Results reveal the importance of refining training systems to reflect staff perceptions and improve evaluation processes across systems in an effort to reduce health care-associated infections., (Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
11. Effect of Clothing on Measurement of Bone Mineral Density.
- Author
-
McNamara EA, Feldman AZ, Malabanan AO, Abate EG, Whittaker LG, Yano-Litwin A, Dorazio J, and Rosen HN
- Subjects
- Humans, Phantoms, Imaging, Reference Standards, Reproducibility of Results, Absorptiometry, Photon methods, Absorptiometry, Photon standards, Bone Density, Clothing, Diagnostic Errors prevention & control
- Abstract
It is unknown whether allowing patients to have BMD (bone mineral density) studies acquired while wearing radiolucent clothing adlib contributes appreciably to the measurement error seen. To examine this question, a spine phantom was scanned 30 times without any clothing, while draped with a gown, and while draped with heavy winter clothing. The effect on mean BMD and on SD (standard deviation) was assessed. The effect of clothing on mean or SD of the area was not significant. The effect of clothing on mean and SD for BMD was small but significant and was around 1.6% for the mean. However, the effect on BMD precision was much more clinically important. Without clothing the spine phantom had an least significant change of 0.0077 gm/cm(2), while when introducing variability of clothing the least significant change rose as high as 0.0305 gm/cm(2). We conclude that, adding clothing to the spine phantom had a small but statistically significant effect on the mean BMD and on variance of the measurement. It is unlikely that the effect on mean BMD has any clinical significance, but the effect on the reproducibility (precision) of the result is likely clinically significant., (Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
12. Utility of Reviewing Radiology Studies in Electronic Medical Records When Preparing Bone Mineral Density Reports.
- Author
-
McNamara EA, Malabanan AO, Abate EG, Whittaker LG, Yano-Litwin A, and Rosen HN
- Subjects
- Female, Hip diagnostic imaging, Humans, Lumbar Vertebrae diagnostic imaging, Male, Quality Indicators, Health Care, Radiography, Abdominal statistics & numerical data, Radiography, Thoracic statistics & numerical data, Time Management, Tomography, X-Ray Computed statistics & numerical data, United States, Absorptiometry, Photon methods, Absorptiometry, Photon statistics & numerical data, Bone Density, Electronic Health Records statistics & numerical data, Medical Record Linkage methods, Medical Record Linkage standards
- Abstract
We quantitated how often review of recent radiology studies provides information useful to the densitometrist. While preparing bone mineral density (BMD) reports on 1012 consecutive patients, radiology reports in electronic medical records (EMRs) for the previous 5 years at potentially relevant sites (lumbar spine X-rays, abdominal computed tomography (CT) scans, and so forth) were reviewed. When a study was found, it received a grade according to how relevant findings were to the BMD report: "1" for studies that were irrelevant, "2" for those that confirmed the impression formed from review of the BMD images, "3" for those that clarified the impression that was unclear after reviewing the BMD images, and "4" for those that revealed new relevant data when no abnormality was noted on review of the BMD images. A total of 562 patients (55.5%) had a radiologic study at a site of potential interest within the past 5 years. Fifty-three patients (5.2% of all patients) had a grade 4 study, 88 patients (8.7% of all patients) had a grade 3 study, and 185 patients (18.3% of all patients) had a grade 2 study. Two hundred sixty-four patients (25.8%) had a grade 2 or 3 study, and 299 (29.5%) had a grade 2-4 study. The radiographic study that was most likely to be found in patients' EMR was chest X-ray (34.7% of all patients), but it was also the one that was least likely to have any relevance to the reader; only 10.5% of the total chest X-rays were graded 2-4. The next most likely studies to be found in patients' EMR were abdominal CT scans (18.0% of all patients) and lumbar spine X-rays (14.4% of all patients), but these studies were much more likely to be useful to the reader, as 62.6% of abdominal CT scans and 78.1% of lumbar spine X-rays were graded 2-4. The likelihood of a patient having radiologic examinations in the EMR at sites potentially relevant to the BMD reader is high, but the likelihood that these clarify abnormalities noted on BMD is only moderate. Review of the EMR is unlikely to be relevant when the dual-energy X-ray absorptiometry images are normal., (Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
13. Inconsistency in filling in the bottom of the spine bone map affects reported spine bone mineral density.
- Author
-
Malabanan AO, Whittaker LG, McNamara EA, and Rosen HN
- Subjects
- Absorptiometry, Photon, Bone Density
- Abstract
Objective: We hypothesized that variability from year to year in how much of the bone map was filled in at the bottom of the spine region of interest (ROI) contributes substantially to variability in measurement of spine bone mineral density (BMD)., Methods: A total of 110 spine BMDs with defects in the bone mapping at the bottom were reanalyzed, with the only change being manually drawing a straight line across the bottom of the ROI and filling in the bone map., Results: The mean (SD) change in area, bone mineral content, and BMD for total spine when the bottom of the bone map was filled in was 0.919 (0.411) cm2, 0.201 (0.121) g, and -0.0098 (0.0043) g/cm2, respectively, and all changes were significant (P<.0001). The largest individual change in total spine BMD with reanalysis was 0.0238 g/cm2, close to the least significant change (LSC) of 0.026 g/cm2 in our center. To quantify variability due to this change in analysis, we calculated an LSC(fill), in which the pairs of scans consisted of the same scan before and after filling in the bottom of the spine bone map, without any other change. The LSC(fill) attributable just to the reanalysis of missing bone map at the bottom of the spine was 0.021 g/cm2, suggesting substantial variance due to variability in mapping the bottom of the spine., Conclusion: When there is a noticeable defect in the bottom of the spine bone map, filling this defect in consistently eliminates a significant source of variability in analysis of spine BMDs and might allow us to achieve smaller LSCs.
- Published
- 2014
- Full Text
- View/download PDF
14. Lifting Disabled Patients onto the Densitometer with a Ceiling Lift: Effect of the Sling on Measurement of BMD.
- Author
-
Whittaker LG, McNamara EA, Malabanan AO, and Rosen HN
- Subjects
- Humans, Absorptiometry, Photon, Bone Density, Persons with Disabilities, Moving and Lifting Patients methods
- Abstract
Objective: Lifting disabled patients onto a densitometer manually is dangerous for both the patient and the densitometry staff; using a ceiling lift is the preferred method of transfer. This system requires the use of a sling underneath the patient. Unless extra time is taken for its removal, the sling remains underneath the patient as bone mineral density (BMD) is measured. The aim of this study was to determine whether leaving this sling in place during scan acquisition affects the BMD measurement., Methods: Measurements were taken of a spine phantom 30 times by itself, 30 times with a standard sling underneath the spine phantom, and 16 times with a disposable sling underneath the spine phantom., Results: We found that mean BMD was significantly different versus the phantom alone when a sling was used, due to differences in area, bone mineral content, or both. The disposable sling affected the mean BMD to a much greater extent than did the standard sling (+1.9% vs. -0.41%; P for the difference between slings <.001). The standard sling did not increase the variance in the BMD measurement compared with the spine phantom alone, whereas the disposable sling did increase the variance in the BMD measurements., Conclusion: Commercially available ceiling-lift slings affect BMD measurements of spine phantoms. This effect is expected to persist when BMD is measured in patients and suggests that when lifting a patient onto the densitometer using these slings, it is best to take the time to remove the sling from under the patient after transfer and before scanning.
- Published
- 2014
- Full Text
- View/download PDF
15. Reduction in Clostridium difficile infections among neurosurgical patients associated with discontinuation of antimicrobial prophylaxis for the duration of external ventricular drain placement.
- Author
-
Dellit TH, Chan JD, Fulton C, Pergamit RF, McNamara EA, Kim LJ, Ellenbogen RG, and Lynch JB
- Subjects
- Anti-Bacterial Agents administration & dosage, Anti-Bacterial Agents therapeutic use, Cefazolin administration & dosage, Cefazolin therapeutic use, Clostridium Infections prevention & control, Controlled Before-After Studies, Cross Infection prevention & control, Drug Administration Schedule, Humans, Neurosurgical Procedures adverse effects, Antibiotic Prophylaxis, Clostridioides difficile, Clostridium Infections epidemiology, Cross Infection epidemiology, Drainage methods, Neurosurgical Procedures methods
- Published
- 2014
- Full Text
- View/download PDF
16. Metaphyseal and diaphyseal bone loss in the tibia following transient muscle paralysis are spatiotemporally distinct resorption events.
- Author
-
Ausk BJ, Huber P, Srinivasan S, Bain SD, Kwon RY, McNamara EA, Poliachik SL, Sybrowsky CL, and Gross TS
- Subjects
- Animals, Bone Resorption diagnostic imaging, Diaphyses diagnostic imaging, Mice, Muscle, Skeletal diagnostic imaging, Paralysis diagnostic imaging, Tibia diagnostic imaging, Time Factors, X-Ray Microtomography, Bone Resorption complications, Bone Resorption physiopathology, Diaphyses physiopathology, Muscle, Skeletal physiopathology, Paralysis complications, Paralysis physiopathology, Tibia physiopathology
- Abstract
When the skeleton is catabolically challenged, there is great variability in the timing and extent of bone resorption observed at cancellous and cortical bone sites. It remains unclear whether this resorptive heterogeneity, which is often evident within a single bone, arises from increased permissiveness of specific sites to bone resorption or localized resorptive events of varied robustness. To explore this question, we used the mouse model of calf paralysis induced bone loss, which results in metaphyseal and diaphyseal bone resorption of different timing and magnitude. Given this phenotypic pattern of resorption, we hypothesized that bone loss in the proximal tibia metaphysis and diaphysis occurs through resorption events that are spatially and temporally distinct. To test this hypothesis, we undertook three complimentary in vivo/μCT imaging studies. Specifically, we defined spatiotemporal variations in endocortical bone resorption during the 3weeks following calf paralysis, applied a novel image registration approach to determine the location where bone resorption initiates within the proximal tibia metaphysis, and explored the role of varied basal osteoclast activity on the magnitude of bone loss initiation in the metaphysis using μCT based bone resorption parameters. A differential response of metaphyseal and diaphyseal bone resorption was observed throughout each study. Acute endocortical bone loss following muscle paralysis occurred almost exclusively within the metaphyseal compartment (96.5% of total endocortical bone loss within 6days). Using our trabecular image registration approach, we further resolved the initiation of metaphyseal bone loss to a focused region of significant basal osteoclast function (0.03mm(3)) adjacent to the growth plate. This correlative observation of paralysis induced bone loss mediated by basal growth plate cell dynamics was supported by the acute metaphyseal osteoclastic response of 5-week vs. 13-month-old mice. Specifically, μCT based bone resorption rates normalized to initial trabecular surface (BRRBS) were 3.7-fold greater in young vs. aged mice (2.27±0.27μm(3)/μm(2)/day vs. 0.60±0.44μm(3)/μm(2)/day). In contrast to the focused bone loss initiation in the metaphysis, diaphyseal bone loss initiated homogeneously throughout the long axis of the tibia predominantly in the second week following paralysis (81.3% of diaphyseal endocortical expansion between days 6 and 13). The timing and homogenous nature are consistent with de novo osteoclastogenesis mediating the diaphyseal resorption. Taken together, our data suggests that tibial metaphyseal and diaphyseal bone loss induced by transient calf paralysis are spatially and temporally discrete events. In a broader context, these findings are an essential first step toward clarifying the timing and origins of multiple resorptive events that would require targeting to fully inhibit bone loss following neuromuscular trauma., (© 2013.)
- Published
- 2013
- Full Text
- View/download PDF
17. Bowel function of healthy men consuming liquid diets with and without dietary fiber.
- Author
-
Slavin JL, Nelson NL, McNamara EA, and Cashmere K
- Subjects
- Adult, Defecation, Humans, Male, Time Factors, Dietary Fiber administration & dosage, Feces, Food, Formulated, Gastrointestinal Motility
- Abstract
The importance of the level of dietary fiber intake on bowel function was measured in 16 healthy young males consuming self-selected and liquid enteral diets. Subjects consumed liquid Ensure as their sole nutrient source plus 0 (diet a), 30 (diet c), and 60 (diet d) g/day soy fiber, a fiber source high in hemicellulose that was added to the Ensure. Further, to examine whether heat processing affects the physiologic action of fiber, subjects consumed Enrich, an enteral formula similar to Ensure, which contains 30 g of the same soy fiber (diet b). The four diets were consumed in randomized order each for 10 days. Daily wet stool weight averaged 144.6 g on the self-selected diet and decreased significantly to 67.3 g when Ensure was consumed alone. Average stool weights on diets (b), (c), and (d) were 114.6, 100.2, and 150.3 g/day, respectively. Average fecal dry weights for the four diets were 19.1, 28.7, 25.0, and 30.3 g/day for (a-d), respectively. Gastrointestinal transit time, as measured with radiopaque pellets, was longest on the Ensure diet, 72.4 hr, and approximately 2 days on the fiber-supplemented diets and the self-selected diet. Thus, soy fiber's physiologic effect on laxation was not changed by heat processing. Also, although stool weights were larger on higher fiber intakes, transit rates were similar on all the fiber-containing diets.
- Published
- 1985
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.