18 results on '"Martinez-Moreno B"'
Search Results
2. SAFETY AND FEASIBILITY OF LUMEN-APOSSING METAL STENTS REMOVALS. RESULTS FROM A PROSPECTIVE NATIONWIDE REGISTRY
- Author
-
Bazaga, S., additional, Garcia-Alonso, F.J., additional, Aparicio Tormo, J.R., additional, Martinez Moreno, B., additional, Sanchiz, V., additional, Suria, C., additional, Garcia-Sumalla, A., additional, Gornals, J.B, additional, Loras, C., additional, Chavarría, C., additional, García-Fernandez, F.J., additional, Terán, Á., additional, Vazquez-Sequeiros, E., additional, Pedraza Sanz, R., additional, Pérez-Carazo, L., additional, Súbtil, J.C., additional, Pérez-Millan, A., additional, Uceda Porta, F., additional, Busto Bea, V., additional, de la Serna-Higuera, C., additional, Pinto García, I., additional, Colán-Hernández, J., additional, Huertas, C., additional, Vilella Martorell, A., additional, Guardiola-Arévalo, A., additional, Castro Urda, J.L., additional, Nuñez-Otero, J., additional, Sánchez-Hernández, E., additional, Gonzalez-Huix, F., additional, de la Morena, F., additional, Villanueva Pavón, R., additional, Couto-Worner, I., additional, Guarner-Argente, C., additional, and Perez-Miranda, M., additional
- Published
- 2022
- Full Text
- View/download PDF
3. Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: A systematic review and meta-analysis
- Author
-
Guzman-Calderon E, Chacaltana A, Diaz R, Li B, Martinez-Moreno B, and Aparicio J
- Subjects
plastic stents ,pancreatic fluid collection ,endoscopic ultrasound ,lumen apposing metal stent - Abstract
Background/Aims Peripancreatic fluid collections (PFCs) result from acute or chronic pancreatic inflammation that suffers a rupture of its ducts. Currently, there exists three options for drainage or debridement of pancreatic pseudocysts and walled-off necrosis (WON). The traditional procedure is drainage by placing double pigtail plastic stents (DPPS); lumen-apposing metal stent (LAMS) has a biflanged design with a wide lumen that avoids occlusion with necrotic tissue, which is more common with DPPS and reduces the possibility of migration. We performed a systematic review and meta-analyses head-to-head, including only studies that compare the two main techniques to drainage of PFCs: LAMS vs DPPS. Methods We conducted a systematic review in different databases, such as PubMed, OVID, Medline, and Cochrane Databases. This meta-analysis considers studies published from 2014 to 2020, including only studies that compare the two main techniques to drainage of PFCs: LAMS vs DPPS. Results Thirteen studies were included in the meta-analyses. Only one of all studies was a randomized controlled trial. These studies comprise 1584 patients; 68.2% were male, and 31.8% were female. Six hundred sixty-three patients (41.9%) were treated with LAMS, and 921 (58.1%) were treated with DPPS. Six studies included only WON in their analysis, two included only pancreatic pseudocysts, and five studies included both pancreatic pseudocysts and WON. The technical success was similar in patients treated with LAMS and DPPS (97.6% vs 97.5%, respectively, P = .986, RR = 1.00 [95% CI 0.93-1.08]). The clinical success was similar in both groups (LAMS: 90.1% vs DPPS: 84.2%, P = .139, RR = 1.063 [95% CI 0.98-1.15]). Patients treated with LAMS had a lower complication rate than the DPPS groups, with a significant statistical difference (LAMS: 16.0% vs DPPS: 20.2%, P = .009, RR = 0.746 [95% CI 0.60-0.93]). Bleeding was the most common complication in the LAMS group (33 patients, [5.0%]), whereas infection was the most common complication in the DPPS group (56 patients, [6.1%]). The LAMS migration rate was lower than in the DPPS (0.9% vs 2.2%, respectively, P = .05). The mortality rate was similar in both groups, 0.6% in the LAMS group (four patients) and 0.4% in the DPPS group (four patients; P = .640). Conclusion The PFCs drainage is an indication when persistent symptoms or PFCs-related complications exist. EUS guided drainage with LAMS has similar technical and clinical success to DPPS drainage for the management of PFCs. The technical and clinical success rates are high in both groups. However, LAMS drainage has a lower adverse events rate than DPPS drainage. More randomized controlled trials are needed to confirm the real advantage of LAMS drainage over DPPS drainage.
- Published
- 2022
4. Classification, outcomes, and management of misdeployed stents during EUS-guided gastroenterostomy
- Author
-
Ghandour B, Bejjani M, Irani SS, Sharaiha RZ, Kowalski TE, Pleskow DK, Do-Cong Pham K, Anderloni AA, Martinez-Moreno B, Khara HS, D'Souza LS, Lajin M, Paranandi B, Subtil JC, Fabbri C, Weber T, Barthet M, and Khashab MA
- Abstract
BACKGROUND AND AIMS: Stent misdeployment (SM) has hindered the dissemination of EUS-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction (GOO) management. We aimed to provide a classification system for SM during EUS-GE and study clinical outcomes and management accordingly. METHODS: This is a retrospective study involving 16 tertiary care centers (8 in the United States, 8 in Europe) from March 2015 to December 2020. Patients who developed SM during EUS-GE for GOO were included. We propose classifying SM into 4 types. The primary outcome was rate and severity of SM (per American Society for Gastrointestinal Endoscopy lexicon), whereas secondary outcomes were clinical outcomes and management of dislodgement according to the SM classification type, in addition to salvage management of GOO after SM. RESULTS: From 467 EUS-GEs performed for GOO during the study period, SM occurred in 46 patients (9.85%). Most SMs (73.2%) occurred during the first 13 EUS-GE cases by the performing operators. SM was graded as mild (n = 28, 60.9%), moderate (n = 11, 23.9%), severe (n = 6, 13.0%), or fatal (n = 1, 2.2%), with 5 patients (10.9%) requiring surgical intervention. Type I SM was the most common (n = 29, 63.1%), followed by type II (n = 14, 30.4%), type IV (n = 2, 4.3%), and type III (n = 1, 2.2%). Type I SM was more frequently rated as mild compared with type II SM (75.9% vs 42.9%, P = .04) despite an equivalent rate of surgical repair (10.3% vs 7.1%, P = .7). Overall, 4 patients (8.7%) required an intensive care unit stay (median, 2.5 days). The median length of stay was 4 days after SM. CONCLUSIONS: Although SM is not infrequent during EUS-GE, most are type I, mild/moderate in severity, and can be managed endoscopically with a surgical intervention rate of approximately 11%.
- Published
- 2022
5. Per-oral pancreatoscopy-guided lithotripsy for the endoscopic management of pancreatolithiasis: A systematic review and meta-analysis
- Author
-
Guzman-Calderon E, Martinez-Moreno B, Casellas J, and Aparicio J
- Subjects
body regions ,pancreatolithiasis ,genetic structures ,lithotripsy ,per-oral pancreatoscopy - Abstract
Objective Pancreatic stones result from chronic pancreatitis and can occur in the main pancreatic duct, pancreatic branches or parenchyma. Although extracorporeal shock wave lithotripsy (ESWL) is considered the first-line treatment, per-oral pancreatoscopy (POP) has emerged as a useful method for treating pancreatic stones. The aim of this systematic review and meta-analysis was to determine the efficacy and safety of POP-guided lithotripsy, electrohydraulic lithotripsy (EHL) and laser lithotripsy (LL), in patients with pancreatolithiasis. Methods Literature review was conducted in PubMed, OVID, MEDLINE and Cochrane Library databases for studies published up to August 2020. Results Altogether 15 studies were analyzed, of which 11 were retrospective and four were prospective. The studies comprised 370 patients, of whom 66.4% were male. The patients underwent 218 EHL and 155 LL. The pooled technical and clinical success rate of the overall POP was 88.1% and 87.1%. For EHL-POP, the pooled technical success rate was 90.9% (95% CI 87.2%-95.2%) and the pooled clinical success rate was 89.8% (95% CI 87.2%-95.2%). While for LL-POP, the pooled technical and clinical success rate was 88.4% (95% CI 85.9%-95.1%) and 85.8% (95% CI 80.6%-91.6%). In total 43 adverse events occurred (12.1%; 95% CI 8.7%-15.5%). Conclusion POP-guided lithotripsy has a high rate of technical and clinical success for managing pancreatolithiasis with a low complication rate. Both EHL-POP and LL-POP achieve similar efficacy in the endoscopic therapy of pancreatolithiasis. Further large randomized controlled trials are needed to compare EHL-POP and LL-POP with ESWL and evaluate whether POP may replace ESWL as the first-line management of pancreatolithiasis.
- Published
- 2021
- Full Text
- View/download PDF
6. Transpancreatic precut papillotomy versus double-guidewire technique in difficult biliary cannulation: a systematic review and meta-analysis
- Author
-
Guzman-Calderon E, Martinez-Moreno B, Casellas J, and Aparicio J
- Abstract
Background and study aims Approximately 11% of biliary cannulations are considered difficult. The double guidewire (DGW-T) and transpancreatic sphincterotomy (TPS) are two useful techniques when difficult cannulation exists and the main pancreatic duct is unintentionally accessed. We carried out a systematic review and meta-analysis to evaluate the effectiveness and security of both DGW-T and TPS techniques in difficult biliary cannulation. Methods We conducted a systematic review in different databases, such as PubMed, OVID, Medline, and Cochrane Databases. Were included all RCT which showed a comparison between TPS and DGW in difficult biliary cannulation. Endpoints computed were successful cannulation rate, median cannulation time, and adverse events rate. Results Four studies were selected (4 RCTs). These studies included 260 patients. The mean age was 64.79 +/- 12.99 years. Of the patients, 53.6% were men and 46.4% were women. The rate of successful cannulation was 93.3% in the TPS group and 79.4% in the DGW-T group (P = 0.420). The rate of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) was lower in patients who had undergone TPS than DGW-T (TPS: 8.9% vs DGW-T: 22.2%, P = 0.02). The mean cannulation time was 14.7 +/- 9.4 min in the TPS group and 15.1 +/- 7.4 min with DGW-T (P = 0.349). Conclusions TPS and DGW are two useful techniques in patients with difficult cannulation. They both have a high rate of successful cannulation; however, the PEP was higher with DGW-T than with TPS.
- Published
- 2021
7. Prospective and Multicenter Evaluation of the Impact Of Eus-Guided Gastroenterostomy (EUS-GE) On The Quality Of Life Of Patients With Malignant Gastric Outlet Obstruction (GOO)
- Author
-
Garcia Alonso, FJ, additional, Martín-Álvarez, V, additional, Chavarria, C, additional, Aparicio, JR, additional, Martinez-Moreno, B, additional, Subtil, JC, additional, Vila, JJ, additional, Busto Bea, V, additional, de la Serna-Higuera, C, additional, and Perez-Miranda, M, additional
- Published
- 2021
- Full Text
- View/download PDF
8. MULTICENTER RETROSPECTIVE CASE SERIES ASSESSING ADVERSE EVENTS ASSOCIATED TO THE INDWELL AND STENT RETRIEVAL OF LUMEN APPOSING METAL STENTS
- Author
-
Bazaga, S, additional, Yaiza Carbajo, A, additional, Javier García-Alonso, F, additional, Martí, D, additional, Sánchiz Soler, V, additional, Martinez Moreno, B, additional, Ramón Aparicio Tormo, J, additional, Pedraza Sanz, R, additional, Villanueva Hernández, R, additional, Vila Costas, J, additional, Vázquez Sequeiros, E, additional, Jordán Castro, A, additional, Jiménez Palacios, M, additional, and Pérez-Miranda, M, additional
- Published
- 2019
- Full Text
- View/download PDF
9. EUS-GUIDED RECANALIZATION OF ACOMPLETE STENOSIS OF THE BILIARY ANASTOMOSIS IN A PATIENT WITH WHIPPLE RESECTION
- Author
-
Martinez Moreno, B, additional, Roger Ibañez, M, additional, and Acevedo Piedra, G, additional
- Published
- 2019
- Full Text
- View/download PDF
10. EUS-guided tissue acquisition in the study of the adrenal glands: Results of a nationwide multicenter study.
- Author
-
Martin-Cardona, A., Fernandez-Esparrach, G., Subtil, J. C., Iglesias-Garcia, J., Garcia-Guix, M., Barturen Barroso, A., Gimeno-Garcia, A. Z., Esteban, J. M., Pardo Balteiro, A., Velasco-Guardado, A., Vazquez-Sequeiros, E., Loras, C., Martinez-Moreno, B., Castellot, A., Huertas, C., Martinez-Lapiedra, M., Sanchez-Yague, A., Teran, A., Morales-Alvarado, V. J., and Betes, M.
- Subjects
ADRENAL glands ,CYTOLOGY ,POSITRON emission tomography ,PHYSICAL sciences ,TISSUES - Abstract
Background: There are limited data about the role of endoscopic ultrasound-guided tissue acquisition (EUS-TA), by fine needle aspiration (EUS-FNA) or biopsy (EUS-FNB), in the evaluation of the adrenal glands (AG). The primary aim was to assess the diagnostic yield and safety. The secondary aims were the malignancy predictors, and to create a predictive model of malignancy. Methods: This was a retrospective nationwide study involving all Spanish hospitals experienced in EUS-TA of AGs. Inclusion period was from April-2003 to April-2016. Inclusion criteria: all consecutive cases that underwent EUS-TA of AGs. EUS and cytopathology findings were evaluated. Statistical analyses: diagnostic accuracy of echoendoscopist's suspicion using cytology by EUS-TA, as gold standard; multivariate logistic regression model to predict tumor malignancy. Results: A total of 204 EUS-TA of AGs were evaluated. Primary tumor locations were lung70%, others19%, and unknown11%. AG samples were adequate for cytological diagnosis in 91%, and confirmed malignancy in 60%. Diagnostic accuracy of the endosonographer's suspicion was 68%. The most common technique was: a 22-G (65%) and cytological needle (75%) with suction-syringe (66%). No serious adverse events were described. The variables most associated with malignancy were size>30mm (OR2.27; 95%CI, 1.16–4.05), heterogeneous echo-pattern (OR2.11; 95%CI, 1.1–3.9), variegated AG shape (OR2.46; 95%CI, 1–6.24), and endosonographer suspicion (OR17.46; 95%CI, 6.2–58.5). The best variables for a predictive multivariate logistic model of malignancy were age, sex, echo-pattern, and AG-shape. Conclusions: EUS-TA of the AGs is a safe, minimally invasive procedure, allowing an excellent diagnostic yield. These results suggest the possibility of developing a pre-EUS procedure predictive malignancy model. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
11. Correlation of endoscopic ultrasound-guided portal pressure gradient measurements with hepatic venous pressure gradient: a prospective study.
- Author
-
Martinez-Moreno B, Martínez Martínez J, Herrera I, Guilabert L, Rodríguez-Soler M, Bellot P, Miralles C, Pascual S, Irúrzun J, Zapater P, Palazón-Azorín JM, Gil Guillén V, Jover R, and Aparicio JR
- Abstract
Background: Hepatic venous portal gradient (HVPG) measurement remains the gold standard for estimating portal pressure gradient (PPG). This study aimed to evaluate the correlation between endoscopic ultrasound (EUS)-guided PPG and HVPG in patients with chronic portal hypertension., Methods: Patients with chronic portal hypertension in whom HVPG assessment was clinically indicated were invited to undergo transjugular HVPG and EUS-PPG with a 22-G needle in separate sessions for comparison. Intraclass correlation coefficient (ICC) and the Bland-Altman method were used to evaluate the agreement between techniques., Results: 33 patients were included. No significant differences in technical success were observed: EUS-PPG (31/33, 93.9%) vs. HVPG (31/33, 93.9%). Overall, 30 patients who underwent successful EUS-PPG and HVPG were analyzed. Correlation between the two techniques showed an ICC of 0.82 (0.65-0.91). Four patients had major discrepancies (≥5 mmHg) between HVPG and EUS-PPG. No significant differences in adverse events were observed., Conclusions: The correlation between EUS-PPG and HVPG was almost perfect. EUS-PPG could be a safe and reliable method for direct PPG measurement in patients with cirrhosis and a valid alternative to HVPG., Competing Interests: The authors declare that they have no conflict of interest., (Thieme. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
12. Endoscopic ultrasound-guided gallbladder drainage with long-term lumen-apposing metal stent indwell: 1-year results from a prospective nationwide observational study.
- Author
-
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Gornals JB, Loras C, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Súbtil JC, Pérez-Millan A, Uceda Porta F, Vila JJ, de la Serna-Higuera C, Couto-Worner I, Guarner-Argente C, and Perez-Miranda M
- Subjects
- Humans, Male, Aged, Aged, 80 and over, Female, Acute Disease, Prospective Studies, Treatment Outcome, Endosonography adverse effects, Endosonography methods, Drainage adverse effects, Drainage methods, Stents, Ultrasonography, Interventional, Pancreatitis epidemiology, Pancreatitis etiology, Cholecystitis, Acute, Neoplasms etiology
- Abstract
Background and Aim: This study aimed to determine safety and risk factors for adverse events (AEs) of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) with long-term indwell of lumen-apposing metal stents (LAMS)., Methods: This study is a multicenter prospective observational study on consecutive high surgical-risk patients requiring gallbladder drainage who underwent EUS-GBD with LAMS over 12 months. Centralized telephone follow-up interviews were conducted every 3 months for 1 year. Patients were censored at LAMS removal, cholecystectomy, or death. AE-free survival was determined using log-rank tests. Cumulative risks were estimated using life-table analysis., Results: Eighty-two patients were included (53.7% male, median [interquartile range] age of 84.6 [76.5-89.8] years, and 85.4% with acute cholecystitis). Technical success was achieved in 79 (96.3%), and clinical success in 73 (89%). No patient was lost to follow-up; 45 patients (54.9%) completed 1-year follow-up with in situ LAMS. Median (interquartile range) LAMS indwell time was 364 (47-367) days. Overall, 12 (14.6%) patients presented 14 AEs, including 5 (6.1%) recurrent biliary events (3 acute cholangitis, 1 mild acute pancreatitis, and 1 acute cholecystitis). Patients with pancreatobiliary malignancy had an increased risk of recurrent biliary events (33% vs 1.5%, P = 0.001). The overall 1-year cumulative risk of recurrent biliary events was 9.7% (4.1-21.8%). The 1-year risk of AEs and of severe AEs was 18.8% (11-31.2%) and 7.9% (3.3-18.2%), respectively. Pancreatobiliary malignancy was the single risk factor for recurrent biliary events; LAMS misdeployment was the strongest risk factor for AEs., Conclusions: Long-term LAMS indwell does not increase the risk of delayed AEs following EUS-GBD., (© 2023 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.)
- Published
- 2024
- Full Text
- View/download PDF
13. Long-term results after EUS gallbladder drainage in high-surgical-risk patients with acute cholecystitis: A 3-year follow-up registry.
- Author
-
Martinez-Moreno B, López-Roldán G, Martínez-Sempere J, de-Madaria E, Jover R, and Aparicio JR
- Abstract
Background and study aims Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) has become the favorite drainage option for high surgical-risk patients with acute cholecystitis. However, data on long-term outcomes regarding efficacy and security over 1 year are scarce. Patients and methods We performed a retrospective review of a prospectively maintained database to analyze the 3-year long-term outcomes of EUS-GBD with lumen apposing metal stents (LAMS) in high-surgical-risk patients with acute cholecystitis. Results Fifty patients with acute cholecystitis who underwent EUS-GBD with LAMS and 3-year follow-up or until death were included in this study. No endoscopic revisions were scheduled unless an adverse event (AE) or suspected LAMS dysfunction occurred. AEs occurred in 18%, 20%, and 26% of patients in the first, second, and third years, respectively. Thirteen patients developed at least one AE, and six presented with a second AE during follow-up. Recurrence of cholecystitis occurred in two patients (4%). Seven stent migrations (14%) occurred but all were asymptomatic. Symptomatic LAMS-related AEs (LAMS-RAEs) (37.5%) were related to gastric location of the stent compared with duodenal location (66.7% vs. 12.5%, P = 0.03). No stent-related bleeding or stent-related mortality was observed. Conclusions EUS-GBD with LAMS without scheduled removal is an effective and safe long-term treatment in high-surgical-risk patients with acute cholecystitis. Late LAMS-RAEs tend to be more asymptomatic over time. Symptomatic LAMS-RAEs are associated with gastric location, and overall, AEs tend to recur., Competing Interests: Conflict of Interest Belén Martínez-Moreno and José Ramón Aparicio are Boston Scientific consultants. The rest of the authors have nothing to declare., (The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).)
- Published
- 2023
- Full Text
- View/download PDF
14. Correction: Endoscopic removal of lumen-apposing metal stents - risk factors for stent embedment, complex removals, and adverse events: analysis from a multicenter prospective case series.
- Author
-
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Suria C, Garcia-Sumalla A, Gornals JB, Chavarría C, Loras C, García-Fernandez FJ, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Pérez-Carazo L, Súbtil JC, Pérez-Millan A, Uceda Porta F, Busto Bea V, de la Serna-Higuera C, Pinto Garcia I, Colán-Hernández J, Huertas C, Guarner-Argente C, and Perez-Miranda M
- Abstract
Competing Interests: Disclosure The authors report no conflicts of interest in this work.
- Published
- 2023
- Full Text
- View/download PDF
15. Endoscopic removal of lumen-apposing metal stents - risk factors for stent embedment, complex removals, and adverse events: analysis from a multicenter prospective case series.
- Author
-
Bazaga S, García-Alonso FJ, Aparicio Tormo JR, Martinez Moreno B, Sanchiz V, Suria C, Garcia-Sumalla A, Gornals JB, Chavarría C, Loras C, García-Fernandez FJ, Terán Á, Vazquez-Sequeiros E, Pedraza Sanz R, Pérez-Carazo L, Súbtil JC, Pérez-Millan A, Uceda Porta F, Busto Bea V, de la Serna-Higuera C, Pinto Garcia I, Colán-Hernández J, Huertas C, Guarner-Argente C, and Perez-Miranda M
- Subjects
- Humans, Retrospective Studies, Risk Factors, Drainage adverse effects, Endosonography, Stents adverse effects, Endoscopy, Gastrointestinal adverse effects
- Abstract
Background: Removing lumen-apposing metal stents (LAMSs) may be difficult and even harmful, but these features have seldom been analyzed. We aimed to generate a comprehensive assessment of the feasibility and safety of LAMS retrieval procedures., Methods: A prospective multicenter case series including all technically successfully deployed LAMSs between January 2019 and January 2020 that underwent endoscopic stent removal. All retrieval-related data were prospectively recorded using standardized telephone questionnaires as part of centralized follow-up that ended after stent removal had been performed. Multivariable logistic regression models assessed the potential risk factors for complex removal., Results: For the 407 LAMSs included, removal was attempted in 158 (38.8 %) after an indwell time of 46.5 days (interquartile range [IQR] 31-70). The median (IQR) removal time was 2 (1-4) minutes. Removal was labelled as complex in 13 procedures (8.2 %), although advanced endoscopic maneuvers were required in only two (1.3 %). Complex removal risk factors were stent embedment (relative risk [RR] 5.84, 95 %CI 2.14-15.89; P = 0.001), over-the-wire deployment (RR 4.66, 95 %CI 1.60-13.56; P = 0.01), and longer indwell times (RR 1.14, 95 %CI 1.03-1.27; P = 0.01). Partial and complete embedment were observed in 14 (8.9 %) and five cases (3.2 %), respectively. The embedment rate during the first 6 weeks was 3.1 % (2/65), reaching 15.9 % (10/63) during the following 6 weeks ( P = 0.02). The adverse event rate was 5.1 %, including seven gastrointestinal bleeds (5 mild, 2 moderate)., Conclusions: LAMS removal is a safe procedure, mostly requiring basic endoscopic techniques attainable in conventional endoscopy rooms. Referral to advanced endoscopy units should be considered for stents with known embedment or long indwell times, which may require more technically demanding procedures., Competing Interests: M. Perez-Miranda is a consultant for Boston Scientific, Olympus, Medtronic, and M.I.Tech. The remaining authors declare that they have no conflict of interest., (Thieme. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
16. Prospective multicenter assessment of the impact of EUS-guided gastroenterostomy on patient quality of life in unresectable malignant gastric outlet obstruction.
- Author
-
Garcia-Alonso FJ, Chavarria C, Subtil JC, Aparicio JR, Busto Bea V, Martinez-Moreno B, Vila JJ, Martín-Álvarez V, Sanchez-Delgado L, de la Serna-Higuera C, and Perez-Miranda M
- Subjects
- Male, Humans, Aged, Female, Quality of Life, Prospective Studies, Stents, Retrospective Studies, Gastroenterostomy methods, Gastric Outlet Obstruction etiology, Gastric Outlet Obstruction surgery, Adenocarcinoma surgery
- Abstract
Background and Aims: EUS-guided gastroenterostomy (EUS-GE) is increasingly used for malignant gastric outlet obstruction (GOO) in inoperable patients. However, the impact of EUS-GE on patient quality of life (QoL) has not been evaluated prospectively., Methods: Consecutive patients with unresectable malignant GOO who underwent EUS-GE between August 2019 and May 2021 at 4 Spanish centers were prospectively assessed using the European Organization for Research and Treatment of Cancer QoL Questionnaire Core 30 at baseline and 1 month after the procedure. Centralized follow-up by telephone calls was undertaken. The Gastric Outlet Obstruction Scoring System (GOOSS) was used to assess oral intake, defining clinical success as a GOOSS ≥2. Differences between baseline and 30-day QoL scores were assessed using a linear mixed model., Results: Sixty-four patients were enrolled, 33 (51.6%) men, with a median age of 77.3 years (interquartile range, 65.5-86.5). The most common diagnoses were pancreatic (35.9%) and gastric (31.3%) adenocarcinoma. Thirty-seven patients (57.9%) presented a 2/3 baseline Eastern Cooperative Oncology Group performance status score. Oral intake was restarted within 48 hours in 61 patients (95.3%), and the median postprocedure hospital stay was 3.5 days (interquartile range, 2-5). The 30-day clinical success rate was 83.3%. A clinically significant increase of 21.6 points (95% confidence interval, 11.5-31.7) in the global health status scale was documented, with significant improvements in nausea and vomiting, pain, constipation, and appetite loss., Conclusions: EUS-GE relieves GOO symptoms in patients with unresectable malignancy, allowing rapid oral intake and hospital discharge. It also provides a clinically relevant increase in QoL scores at 30 days from baseline. (Clinical trial registration number: NCT04660695.)., (Copyright © 2023 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
17. Intracystic Glucose and Carcinoembryonic Antigen in Differentiating Histologically Confirmed Pancreatic Mucinous Neoplastic Cysts.
- Author
-
Smith ZL, Satyavada S, Simons-Linares R, Mok SRS, Martinez Moreno B, Aparicio JR, and Chahal P
- Subjects
- Carcinoembryonic Antigen, Cohort Studies, Cyst Fluid, Endoscopic Ultrasound-Guided Fine Needle Aspiration, Glucose, Humans, Pancreatic Cyst diagnosis, Pancreatic Cyst pathology, Pancreatic Neoplasms diagnosis, Pancreatic Neoplasms pathology
- Abstract
Introduction: Differentiating mucinous neoplastic pancreatic cysts (MNPC) from cysts without malignant potential can be challenging. Guidelines recommend using fluid carcinoembryonic antigen (CEA) to differentiate MNPC; however, its sensitivity and specificity vary widely. Intracystic glucose concentration has shown promise in differentiating MNPC, but data are limited to frozen specimens and cohorts of patients without histologic diagnoses. This study aimed to compare glucose and CEA concentrations in differentiating MNPC using fresh fluid obtained from cysts with confirmatory histologic diagnoses., Methods: This multicenter cohort study consisted of patients undergoing endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for pancreatic cysts during January 2013-May 2020. Patients were included if the cyst exhibited a histologic diagnosis and if both CEA and glucose were analyzed from fresh fluid. Receiver operating curve (ROC) characteristics were analyzed, and various diagnostic parameters were compared., Results: Ninety-three patients, of whom 59 presented with MNPC, met the eligibility criteria. The area under the receiver operating curve (AUROC) was 0.96 for glucose and 0.81 for CEA (difference 0.145, P = 0.003). A CEA concentration of ≥192 ng/mL had sensitivity of 62.7% and specificity of 88.2% in differentiating MNPC, whereas glucose concentration of ≤25 mg/dL had sensitivity and specificity of 88.1% and 91.2%, respectively., Discussion: Intracystic glucose is superior to CEA concentration for differentiating MNPC when analyzed from freshly obtained fluid of cysts with histologic diagnoses. The advantage of glucose is augmented by its low cost and ease of implementation, and therefore, its widespread adoption should come without barriers. Glucose has supplanted CEA as the best fluid biomarker in differentiating MNPC., (Copyright © 2021 by The American College of Gastroenterology.)
- Published
- 2022
- Full Text
- View/download PDF
18. Endoscopic ultrasound-guided, through-the-needle forceps biopsy for diagnosis of pancreatic cystic lesions: a systematic review.
- Author
-
Guzmán-Calderón E, Martinez-Moreno B, Casellas JA, de Madaria E, and Aparicio JR
- Abstract
Background and study aims Pancreatic cystic lesions (PCL), are a heterogeneous group of cystic lesions. Some patients with PCLs have a significantly higher overall risk of pancreatic cancer and the only test that can differentiate benign and malignnat PCL is fine-needle aspiration plus cytological analysis, but its sensitivity is very low. Through-the-needle direct intracystic biopsy is a technique that allows acquisition of targeted tissue from PCLs and it may improve the diagnostic yield for them. The aim of this study was to review articles about endoscopic ultrasound (EUS)-guided through-the-needle intracystic biopsy for targeted tissue acquisition and diagnosis of PCLs. Methods A systematic review of computerized bibliographic databases was carried out for studies of EUS-guided through-the-needle forceps biopsy (EUS-TTNB) of PCLs. The percentages and their 95 % confidence intervals (CIs) were calculated for all the considered endpoints (technical success, adequate specimens, adverse events (AEs), and overall diagnosis). Results Overall, eight studies with a total of 423 patients were identified. Pooled technical success was 95.6 % of the cases (399/423), (95 % CI, 93.2 %-97.3 %). Technical failure rate was 5.1 % (24 cases). Frequency of adequate specimens was 82.2 %, (95 % CI, 78.5 %-85.8 %). Adverse events were reported in seven of the eight studies. Forty-two total adverse events were reported (10.1 %) (95 % CI, 7.3 %-13.6 %). The overall ability to provide a specific diagnosis with EUS-TTNB for diagnosis of pancreatic cystic lesions was 74.6 % (313 cases), (95 % CI: 70.2 %-78.7 %). The most frequent diagnoses found with EUS-TTNB were mucinous cystic neoplasms (MCN) in 96 cases (30.6 %), IPMN in 80 cases (25.5 %), and serous cystoadenoma neoplasm (SCN) in 48 cases (15.3 %). Conclusions Through-the-needle forceps biopsy appears to be effective and safe, with few AE for diagnosis of pancreatic cystic lesions. This technique had acceptable rates of technical and clinical success and an excellent safety profile. TTNB is associated with a high tissue acquisition yield and provided additional diagnostic yield for mucinous pancreatic lesions. TTNB may be a useful adjunctive tool for EUS-guided assessment of PCLs., Competing Interests: Competing interests The authors declare that they have no conflict of interest.
- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.