- Abstract
Purpose: We propose a tumor tracking framework for 2D cine MRI based on a pair of deep learning (DL) models relying on patient-specific (PS) training., Methods and Materials: The chosen DL models are: 1) an image registration transformer and 2) an auto-segmentation convolutional neural network (CNN). We collected over 1,400,000 cine MRI frames from 219 patients treated on a 0.35 T MRI-linac plus 7,500 frames from additional 35 patients which were manually labelled and subdivided into fine-tuning, validation, and testing sets. The transformer was first trained on the unlabeled data (without segmentations). We then continued training (with segmentations) either on the fine-tuning set or for PS models based on eight randomly selected frames from the first 5 s of each patient's cine MRI. The PS auto-segmentation CNN was trained from scratch with the same eight frames for each patient, without pre-training. Furthermore, we implemented B-spline image registration as a conventional model, as well as different baselines. Output segmentations of all models were compared on the testing set using the Dice similarity coefficient (DSC), the 50% and 95% Hausdorff distance (HD
50% /HD95% ), and the root-mean-square-error of the target centroid in superior-inferior direction (RMSESI )., Results: The PS transformer and CNN significantly outperformed all other models, achieving a median (inter-quartile range) DSC of 0.92 (0.03)/0.90 (0.04), HD50% of 1.0 (0.1)/1.0 (0.4) mm, HD95% of 3.1 (1.9)/3.8 (2.0) mm and RMSESI of 0.7 (0.4)/0.9 (1.0) mm on the testing set. Their inference time was about 36/8 ms per frame and PS fine-tuning required 3 min for labelling and 8/4 min for training. The transformer was better than the CNN in 9/12 patients, the CNN better in 1/12 patients and the two PS models achieved the same performance on the remaining 2/12 testing patients., Conclusion: For targets in the thorax, abdomen and pelvis, we found two PS DL models to provide accurate real-time target localization during MRI-guided radiotherapy., Competing Interests: Declaration of competing interest The Department of Radiation Oncology of the of LMU University Hospital has research agreements with Brainlab and Elekta., (Copyright © 2024. Published by Elsevier Inc.)- Published
- 2024
- Full Text
- View/download PDF