1. A Simulation-Free Replacement Solution for Radiation Therapy Immobilization Devices Using Computer Numerical Control (CNC) -Milled Polystyrene Molds
- Author
-
Samuel Hellman, PhD, Laszlo Voros, MS, Victoria Y. Yu, PhD, Dale M. Lovelock, PhD, Sean Berry, PhD, Lei Zhang, PhD, Margie Hunt, MS, Joseph O. Deasy, PhD, and Laura Cervino, PhD
- Subjects
Medical physics. Medical radiology. Nuclear medicine ,R895-920 ,Neoplasms. Tumors. Oncology. Including cancer and carcinogens ,RC254-282 - Abstract
Purpose: In radiation therapy (RT), if an immobilization device is lost or damaged, the patient may need to be brought back for resimulation, device fabrication, and treatment planning, causing additional imaging radiation exposure, inconvenience, cost, and delay. We describe a simulation-free method for replacing lost or damaged RT immobilization devices. Methods and Materials: Replacement immobilization devices were fabricated using existing simulation scans as design templates by computer numerical control (CNC) milling of molds made from extruded polystyrene (XPS). XPS material attenuation and bolusing properties were evaluated, a standard workflow was established, and 12 patients were treated. Setup reproducibility was analyzed postfacto using Dice similarity coefficient (DSC) and mean distance to agreement (MDA) calculations comparing onboard treatment imaging with computed tomography (CT) simulations. Results: Results showed that XPS foam material had less dosimetric impact (attenuation and bolusing) than materials used for our standard immobilization devices. The average direct cost to produce each replacement mold was $242.17, compared with over $2000 for standard resimulation. Hands-on time to manufacture was 86.3 minutes, whereas molds were delivered in as little as 4 hours and mostly within 24 hours, compared with a week or more required for standard resimulation. Each mold was optically scanned after production and was measured to be within 2-mm tolerance (pointwise displacement) of design input. All patients were successfully treated using the CNC-milled foam mold replacements, and pretreatment imaging verified satisfactory clinical setup reproduction for each case. The external body contours from the setup cone beam CT and the original CT simulation with matching superior-inferior extent were compared by calculating the DSC and MDA. DSC average was 0.966 (SD, 0.011), and MDA average was 2.694 mm (SD, 0.986). Conclusions: CNC milling of XPS foam is a quicker and more convenient solution than traditional resimulation for replacing lost or damaged RT immobilization devices. Satisfactory patient immobilization, low dosimetric impact compared with standard immobilization devices, and strong correlation of onboard contours with CT simulations are shown. We share our clinical experience, workflow, and manufacturing guide to help other clinicians who may want to adopt this solution.
- Published
- 2024
- Full Text
- View/download PDF