2. Extraction du butylhydroxytoluène à partir de dispositifs médicaux invasifs utilisés en néonatologie
- Author
-
Basle, Y. Le, Sautou, V., Mailhot-Jensen, B., Institut de Chimie de Clermont-Ferrand (ICCF), Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université Clermont Auvergne (UCA)-Institut national polytechnique Clermont Auvergne (INP Clermont Auvergne), and Université Clermont Auvergne (UCA)-Université Clermont Auvergne (UCA)
- Subjects
[CHIM]Chemical Sciences - Abstract
International audience
- Published
- 2022
3. Development and application of a protocol for extractables profiling from central venous catheters in neonates.
- Author
-
Le Basle Y, Pinguet J, Bouattour Y, Chennell P, Sautou V, and Mailhot-Jensen B
- Subjects
- Humans, Infant, Newborn, Silicones chemistry, Solvents chemistry, Catheterization, Peripheral methods, Sonication methods, Polyurethanes chemistry, Central Venous Catheters, Gas Chromatography-Mass Spectrometry methods
- Abstract
Peripherally inserted central catheters (PICC-lines) used in neonatology are made of thermoplastic polyurethane (TPU) or silicone. These materials usually contain substances that may leach into drug vehicles or blood. In this extractables study, we determined the optimal extraction conditions using TPU films containing defined amounts of butylhydroxytoluene (BHT) and then applied them on unused and explanted PICC-lines. Maceration and sonication tests were carried out with hexane, acetone and water as the extraction solvents. The analyses were performed using gas and liquid chromatography coupled with mass spectrometry detectors, as well as inductive coupled plasma optical emission spectroscopy to detect a wide range of extractables. We selected a limited list of substances to be sought from the usual adjuvants and monomers, related to their carcinogenic, mutagenic or reprotoxic properties and/or existence in endocrine disruptors lists. The TPU-film experiments showed that acetone was slightly better than hexane, and maceration better than sonication. When applied to PICC-lines, the extraction methods were almost similar but acetone was clearly better than hexane for TPU. From the 48 peaks initially observed in GC-MS, we ended up with 37 peaks to follow in TPU PICC-lines, among which were those of BHT and 4,4'-Methylenebis(cyclohexyl isocyanate) isomers. For silicone PICC-lines, out of 41 peaks initially observed in GC-MS, we followed 20 peaks, most of them being identified as cyclosiloxanes. Barium was the main inorganic element extracted for both PICC-lines. For TPU PICC-lines, the inter-batch variability was higher than for intra-batch, but in silicone devices both were similar. When compared to new PICC-lines, explanted TPU PICC-lines extracted peaks had a lower area under the curve (AUC), while the AUCs of the peaks were higher for the majority of silicone PICC-lines extract compounds. No identified substances were detected above their toxicological threshold, but isocyanates and cyclosiloxanes toxicity was mostly studied for other exposition routes than intravenous. The methods defined in this study were efficient in producing extractable profiles from both PICC-lines., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
4. Critical Drug Loss Induced by Silicone and Polyurethane Implantable Catheters in a Simulated Infusion Setup with Three Model Drugs.
- Author
-
Tokhadzé N, Chennell P, Pereira B, Mailhot-Jensen B, and Sautou V
- Abstract
Silicone and polyurethane are biocompatible materials used for the manufacture of implantable catheters, but are known to induce drug loss by sorption, causing potentially important clinical consequences. Despite this, their impact on the drugs infused through them is rarely studied, or they are studied individually and not part of a complete infusion setup. The aim of this work was to experimentally investigate the drug loss that these devices can cause, on their own and within a complete infusion setup. Paracetamol, diazepam, and insulin were chosen as models to assess drug sorption. Four commonly used silicone and polyurethane catheters were studied independently and as part of two different setups composed of a syringe, an extension set, and silicone or polyurethane implantable catheter. Simulated infusion through the catheter alone or through the complete setup were tested, at flowrates of 1 mL/h and 10 mL/h. Drug concentrations were monitored by liquid chromatography, and the silicone and polyurethane materials were characterized by ATR-IR spectroscopy and Zeta surface potential measurements. The losses observed with the complete setups followed the same trend as the losses induced individually by the most sorptive device of the setup. With the complete setups, no loss of paracetamol was observed, but diazepam and insulin maximum losses were respectively of 96.4 ± 0.9% and 54.0 ± 5.6%, when using a polyurethane catheter. Overall, catheters were shown to be the cause of some extremely high drug losses that could not be countered by optimizing the extension set in the setup.
- Published
- 2021
- Full Text
- View/download PDF
5. Preparation of ordered mesoporous and macroporous thermoplastic polyurethane surfaces for potential medical applications.
- Author
-
Chennell P, Feschet-Chassot E, Sautou V, and Mailhot-Jensen B
- Subjects
- Aluminum Oxide chemistry, Electrodes, Materials Testing, Particle Size, Porosity, Surface Properties, Biocompatible Materials chemistry, Polyurethanes chemistry
- Abstract
Thermoplastic polyurethanes are widely used in medical devices. In order to limit some of their shortfalls, like microbial attachment, surfaces modifications can be required. In this work, a two-step replication method was used to create ordered macroporous and mesoporous thermoplastic polyurethane surfaces using anodic aluminum oxide as master template. The intermediate mould materials that were tested were polystyrene and a polyacrylate resin with inorganic filler. All obtained surfaces were characterized by scanning electron microscopy. The initial anodic aluminum oxide surfaces possessed macro or mesopores, function of anodization conditions. The intermediate mould structure correctly replicated the pattern, but the polystyrene surface structures (pillars) were less resistant than the polyacrylate resin ones. The thermoplastic polyurethane pattern possessed macropores or mesopores of about 130 nm or 46 nm diameter and of about 300 nm or 99 nm interpore distances, respectively, in accordance with the initial pattern. Thermoplastic polyurethanes pore depth was however less than initial anodic aluminum oxide pore depth, linked to an incomplete replication during intermediate mould preparation (60 to 90% depth replication). The correct replication of the original pattern confirms that this novel fabrication method is a promising route for surface patterning of thermoplastic polyurethanes that could be used for medical applications.
- Published
- 2018
- Full Text
- View/download PDF
6. Fabrication of Acrylonitrile-Butadiene-Styrene Nanostructures with Anodic Alumina Oxide Templates, Characterization and Biofilm Development Test for Staphylococcus epidermidis.
- Author
-
Desrousseaux C, Cueff R, Aumeran C, Garrait G, Mailhot-Jensen B, Traoré O, and Sautou V
- Subjects
- Bacterial Adhesion drug effects, Biofilms growth & development, Catheters microbiology, Electrodes, Nanopores, Polymers chemistry, Staphylococcus epidermidis drug effects, Temperature, Acrylonitrile chemistry, Aluminum Oxide chemistry, Biofilms drug effects, Butadienes chemistry, Nanostructures chemistry, Polymers pharmacology, Staphylococcus epidermidis physiology, Styrene chemistry
- Abstract
Medical devices can be contaminated by microbial biofilm which causes nosocomial infections. One of the strategies for the prevention of such microbial adhesion is to modify the biomaterials by creating micro or nanofeatures on their surface. This study aimed (1) to nanostructure acrylonitrile-butadiene-styrene (ABS), a polymer composing connectors in perfusion devices, using Anodic Alumina Oxide templates, and to control the reproducibility of this process; (2) to characterize the physico-chemical properties of the nanostructured surfaces such as wettability using captive-bubble contact angle measurement technique; (3) to test the impact of nanostructures on Staphylococcus epidermidis biofilm development. Fabrication of Anodic Alumina Oxide molds was realized by double anodization in oxalic acid. This process was reproducible. The obtained molds present hexagonally arranged 50 nm diameter pores, with a 100 nm interpore distance and a length of 100 nm. Acrylonitrile-butadiene-styrene nanostructures were successfully prepared using a polymer solution and two melt wetting methods. For all methods, the nanopicots were obtained but inside each sample their length was different. One method was selected essentially for industrial purposes and for better reproducibility results. The flat ABS surface presents a slightly hydrophilic character, which remains roughly unchanged after nanostructuration, the increasing apparent wettability observed in that case being explained by roughness effects. Also, the nanostructuration of the polymer surface does not induce any significant effect on Staphylococcus epidermidis adhesion.
- Published
- 2015
- Full Text
- View/download PDF