3 results on '"Maike Gerdes"'
Search Results
2. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 2 - Acceleration Methods and Implications for Individual Regions
- Author
-
Benedikt Sundermann, Benoit Billebaut, Jochen Bauer, Catalin George Iacoban, Olga Alykova, Christoph Schülke, Maike Gerdes, Harald Kugel, Sojan Neduvakkattu, Holger Bösenberg, and Christian Mathys
- Subjects
Acceleration ,Brain ,Radiology, Nuclear Medicine and imaging ,Signal-To-Noise Ratio ,Magnetic Resonance Imaging - Abstract
Recently introduced MRI techniques facilitate accelerated examinations or increased resolution with the same duration. Further techniques offer homogeneous image quality in regions with anatomical transitions. The question arises whether and how these techniques can be adopted for routine diagnostic imaging.Narrative review with an educational focus based on current literature research and practical experiences of different professions involved (physicians, MRI technologists/radiographers, physics/biomedical engineering). Different hardware manufacturers are considered.Compressed sensing and simultaneous multi-slice imaging are novel acceleration techniques with different yet complimentary applications. They do not suffer from classical signal-to-noise-ratio penalties. Combining 3 D and acceleration techniques facilitates new broader examination protocols, particularly for clinical brain imaging. In further regions of the nervous systems mainly specific applications appear to benefit from recent technological improvements.· New acceleration techniques allow for faster or higher resolution examinations.. · New brain imaging approaches have evolved, including more universal examination protocols.. · Other regions of the nervous system are dominated by targeted applications of recently introduced MRI techniques..· Sundermann B, Billebaut B, Bauer J et al. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 2 - Acceleration Methods and Implications for Individual Regions. Fortschr Röntgenstr 2022; 194: 1195 - 1203. Neuere MR-Techniken ermöglichen unter anderem, Untersuchungen deutlich zu beschleunigen oder in gleicher Zeit höher aufgelöste Bilddaten aufzunehmen und Übergangsregionen mit homogener Bildqualität zu untersuchen. Es stellt sich die Frage nach der breiten Anwendbarkeit solcher Techniken in der Routinediagnostik. Narrative Übersichtsarbeit mit Fortbildungsschwerpunkt basierend auf aktueller Literaturrecherche und praktischen Erfahrungen verschiedener Berufsgruppen (ärztliches Personal, MTRA, MR-Physik/Technik) und mit Geräten unterschiedlicher Hersteller. Mit Compressed Sensing und simultaner Mehrschicht-Bildgebung stehen neue Beschleunigungsverfahren zur Verfügung, die sich in ihren Einsatzmöglichkeiten unterscheiden und ergänzen. Sie weisen keine klassischen Einschränkungen des Signal-Rausch-Verhältnisses auf. Die Kombination von verbesserten 3D- und Beschleunigungstechniken ermöglicht insbesondere bei der Bildgebung des Gehirns neue universelle Untersuchungsprotokolle, während in anderen Regionen des Nervensystems vor allem spezifische Indikation von neuen Methoden profitieren. · Neue Beschleunigungstechniken ermöglichen schnellere bzw. höher aufgelöste Untersuchungen.. · Für die Bildgebung des Gehirns ergeben sich grundlegend neue Ansätze in der Gestaltung von universelleren Untersuchungsprotokollen, während in anderen Regionen des Nervensystems aktuell Einzelanwendungen neuer Techniken dominieren..· Sundermann B, Billebaut B, Bauer J et al. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 2 – Acceleration Methods and Implications for Individual Regions. Fortschr Röntgenstr 2022; 194: 1195 – 1203.
- Published
- 2022
3. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 1-3D Acquisitions, Dixon Techniques and Artefact Reduction
- Author
-
Benedikt Sundermann, Benoit Billebaut, Jochen Bauer, Catalin George Iacoban, Olga Alykova, Christoph Schülke, Maike Gerdes, Harald Kugel, Sojan Neduvakkattu, Holger Bösenberg, and Christian Mathys
- Subjects
Imaging, Three-Dimensional ,Image Interpretation, Computer-Assisted ,Contrast Media ,Humans ,Radiology, Nuclear Medicine and imaging ,Artifacts ,Image Enhancement ,Magnetic Resonance Imaging - Abstract
Recently introduced MRI techniques offer improved image quality and facilitate examinations of patients even when artefacts are expected. They pave the way for novel diagnostic imaging strategies in neuroradiology. These methods include improved 3D imaging, movement and metal artefact reduction techniques as well as Dixon techniques.Narrative review with an educational focus based on current literature research and practical experiences of different professions involved (physicians, MRI technologists/radiographers, physics/biomedical engineering). Different hardware manufacturers are considered.3D FLAIR is an example of a versatile 3D Turbo Spin Echo sequence with broad applicability in routine brain protocols. It facilitates detection of smaller lesions and more precise measurements for follow-up imaging. It also offers high sensitivity for extracerebral lesions. 3D techniques are increasingly adopted for imaging arterial vessel walls, cerebrospinal fluid spaces and peripheral nerves. Improved hybrid-radial acquisitions are available for movement artefact reduction in a broad application spectrum. Novel susceptibility artefact reduction techniques for targeted application supplement previously established metal artefact reduction sequences. Most of these techniques can be further adapted to achieve the desired diagnostic performances. Dixon techniques allow for homogeneous fat suppression in transition areas and calculation of different image contrasts based on a single acquisition.· 3D FLAIR can replace 2 D FLAIR for most brain imaging applications and can be a cornerstone of more precise and more widely applicable protocols.. · Further 3D TSE sequences are increasingly replacing 2D TSE sequences for specific applications.. · Improvement of artefact reduction techniques increase the potential for effective diagnostic MRI exams despite movement or near metal implants.. · Dixon techniques facilitate homogeneous fat suppression and simultaneous acquisition of multiple contrasts..· Sundermann B, Billebaut B, Bauer J et al. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 1-3D Acquisitions, Dixon Techniques and Artefact Reduction. Fortschr Röntgenstr 2022; 194: 1100 - 1108. Neuere MR-Techniken ermöglichen es, gestiegene Anforderungen an Bildqualität zu erfüllen, Patienten trotz zu erwartender Artefakte zu untersuchen und neue Untersuchungsstrategien in der Neuroradiologie zu entwickeln. Dies sind unter anderem verbesserte 3D-Techniken, Methoden zur Verminderung von Bewegungs- und Metall-Artefakten und Dixon-Techniken. Narrative Übersichtsarbeit mit Fortbildungsschwerpunkt basierend auf aktueller Literaturrecherche und praktischen Erfahrungen verschiedener Berufsgruppen (ärztliches Personal, MTRA, MR-Physik/Technik) und mit Geräten unterschiedlicher Hersteller. Unter den 3D-Turbo-Spin-Echo-Techniken fällt insbesondere die 3D FLAIR-Sequenz durch vielfältige Einsatzmöglichkeiten in Routineprotokollen auf. Neben der Erkennbarkeit kleinerer Läsionen ermöglicht sie eine präzisere Verlaufsbeurteilung und eine gute Erkennbarkeit auch extrazerebraler Läsionen. 3D-Sequenzen sind zunehmend etabliert zur Beurteilung arterieller Gefäßwände, der Liquorräume und peripherer Nerven. Weiterentwickelte hybrid-radiale Sequenzen ermöglichen ein breiteres Anwendungsspektrum zur Vermeidung von Bewegungsartefakten. Für die Verringerung von Suszeptibilitätsartefakten stehen nun mehrere unterschiedliche Optionen zur Verfügung, die möglichst gezielt eingesetzt werden sollten. Die neuen Techniken ermöglichen zum Teil gezielte Anpassungen zur Erzielung der gewünschten diagnostischen Aussagefähigkeit. Dixon-Techniken ermöglichen es, über eine homogene Fettsättigung in Übergangsregionen hinaus, mit einer Messung mehrere Bildkontraste zu erzielen. · 3D FLAIR des Gehirns kann 2 D FLAIR meist ersetzen und ermöglicht genauere und breiter einsetzbare Untersuchungsprotokolle.. · Andere 3D-TSE-Sequenzen ersetzen für bestimmte Indikationen zunehmend 2D-TSE-Sequenzen.. · Die Weiterentwicklung von Artefaktreduktionstechniken vergrößert bei Bewegungsunruhe und bei Implantaten kontinuierlich das Potenzial für diagnostisch aussagefähige Untersuchungen.. · Dixon ermöglicht homogene Fettsättigung und erzielt gleichzeitig mehrere Bildkontraste..· Sundermann B, Billebaut B, Bauer J et al. Practical Aspects of novel MRI Techniques in Neuroradiology: Part 1–3D Acquisitions, Dixon Techniques and Artefact Reduction. Fortschr Röntgenstr 2022; 194: 1100 – 1109.
- Published
- 2022
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.