1. Assessment of a Bayesian Vitrea CT Perfusion Analysis to Predict Final Infarct and Penumbra Volumes in Patients with Acute Ischemic Stroke: A Comparison with RAPID
- Author
-
Ciprian N. Ionita, Alexander R. Podgorsak, Ryan A. Rava, Adnan H. Siddiqui, Yiemeng Hoi, Maxim Mokin, Kenneth V. Snyder, Jason M Davies, Jillian L. Senko, Muhammad Waqas, M.M. Shiraz Bhurwani, Elad I. Levy, and Ariana B. Allman
- Subjects
Adult ,Male ,Perfusion Imaging ,Perfusion scanning ,Neuroimaging ,Fluid-attenuated inversion recovery ,030218 nuclear medicine & medical imaging ,Brain Ischemia ,03 medical and health sciences ,0302 clinical medicine ,Image Interpretation, Computer-Assisted ,Medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,In patient ,cardiovascular diseases ,Endovascular treatment ,Acute ischemic stroke ,Aged ,Retrospective Studies ,Aged, 80 and over ,business.industry ,Penumbra ,Adult Brain ,Bayes Theorem ,Middle Aged ,Stroke ,Diffusion Magnetic Resonance Imaging ,Infarct volume ,Female ,Neurology (clinical) ,Nuclear medicine ,business ,Tomography, X-Ray Computed ,Perfusion ,030217 neurology & neurosurgery ,Algorithms - Abstract
BACKGROUND AND PURPOSE: Brain CTP is used to estimate infarct and penumbra volumes to determine endovascular treatment eligibility for patients with acute ischemic stroke. We aimed to assess the accuracy of a Bayesian CTP algorithm in determining penumbra and final infarct volumes. MATERIALS AND METHODS: Data were retrospectively collected for 105 patients with acute ischemic stroke (55 patients with successful recanalization [TICI 2b/2c/3] and large-vessel occlusions and 50 patients without interventions). Final infarct volumes were calculated using DWI and FLAIR 24 hours following CTP imaging. RAPID and the Vitrea Bayesian CTP algorithm (with 3 different settings) predicted infarct and penumbra volumes for comparison with final infarct volumes to assess software performance. Vitrea settings used different combinations of perfusion maps (MTT, TTP, CBV, CBF, delay time) for infarct and penumbra quantification. Patients with and without interventions were included for assessment of predicted infarct and penumbra volumes, respectively. RESULTS: RAPID and Vitrea default setting had the most accurate final infarct volume prediction in patients with interventions ([Spearman correlation coefficient, mean infarct difference] default versus FLAIR: [0.77, 4.1 mL], default versus DWI: [0.72, 4.7 mL], RAPID versus FLAIR: [0.75, 7.5 mL], RAPID versus DWI: [0.75, 6.9 mL]). Default Vitrea and RAPID were the most and least accurate in determining final infarct volume for patients without an intervention, respectively (default versus FLAIR: [0.76, –0.4 mL], default versus DWI: [0.71, –2.6 mL], RAPID versus FLAIR: [0.68, −49.3 mL], RAPID versus DWI: [0.65, –51.5 mL]). CONCLUSIONS: Compared with RAPID, the Vitrea default setting was noninferior for patients with interventions and superior in penumbra estimation for patients without interventions as indicated by mean infarct differences and correlations with final infarct volumes.
- Published
- 2020