1. Critical Appraisal of Paediatric Embryonal Cancers Treated with Image-guided Intensity-modulated Proton Therapy
- Author
-
D.S. Sharma, N.M. Padanthaiyil, G. Krishnan, M. Arjunan, A.K. Reddy, S. Mahammood, S. Gayen, R. Thiyagarajan, U. Gaikwad, R.T. Sudarsan, S. Chilukuri, and R. Jalali
- Subjects
Oncology ,Radiology, Nuclear Medicine and imaging - Abstract
To carry out a comprehensive critical appraisal of image-guided intensity-modulated proton therapy practice for craniospinal irradiation (CSI).An image-guided intensity-modulated proton therapy database of 45 consecutive paediatric patients with central nervous system embryonal malignancies treated between January 2019 and April 2022 were critically appraised for demography, diagnosis, treatment planning strategy and treatment delivery accuracy.Most patients (median age: 7.5 years; male:female ratio: 34:11) had medulloblastoma (56%), followed by recurrent ependymoma (19%), pinealoblastoma (5%), germ cell (5%) and others (15%). The dose to the planning target volume-craniospinal (PTV-CS; length 39.06-79.59 cm) varied from 21 to 35 GyRBE, whereas the combined median dose to craniospinal and boost was 54 GyRBE. In all patients, the 95% isodose line covered the cribriform plate completely and optic nerves mostly, with a median V95% of 100% and 82.96%, keeping Dmax to the lens3.9 GyRBE. In skeletally immature patients (88.38%), the anterior vertebral body was completely covered in 18.18% and underdosed in 70.15% of the cases, resulting in a median Dmean of 10.11 GyRBE to the oesophagus. Lateral spine coverage was maintained on the edges of the vertebral body in 52.2%, whereas it extended beyond in 48.8%. The median V98% for clinical target volumes and V95% for PTVs of the brain, spine and craniospinal were97%, with excellent conformity (0.89) and homogeneity (0.07) indices for PTV-CS. All neurological organs at risk received a median Dmax ranging from 36 to 44 GyRBE from the combined CSI and boost regimens. Analysis of patient-specific quality assurance results revealed that 545 (97.67%) planar dosage verification had gamma (3% at 3 mm) values95%. The online patient set-up verification showed translational and rotational deviation within 2 mm and 0.5° in 88-94% and 97% of the cases. Systematic and random error were within 0.90 mm and 1.71 mm in translation and 0.1° and 0.2° in rotation.A change in practice pattern was observed. The findings from our comprehensive critical appraisal add to the growing library of CSI practice and may serve as a reference for inter-institutional comparison.
- Published
- 2022