5 results on '"Lucaccini Paoli L"'
Search Results
2. Evaluation of time in tight range and the glycaemia risk index in adults with type 1 diabetes using an advanced hybrid closed loop system: A 1-year real-world assessment.
- Author
-
Rizzi A, Tartaglione L, Lucaccini Paoli L, Leo ML, Popolla V, Viti L, Barberio A, Di Leo M, Pontecorvi A, and Pitocco D
- Subjects
- Humans, Female, Male, Adult, Retrospective Studies, Middle Aged, Glycated Hemoglobin analysis, Time Factors, Hypoglycemia blood, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 drug therapy, Blood Glucose analysis, Insulin Infusion Systems, Insulin administration & dosage, Insulin therapeutic use, Blood Glucose Self-Monitoring methods, Blood Glucose Self-Monitoring instrumentation, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use, Glycemic Control methods
- Abstract
Aim: To assess the long-term glycaemic outcomes, with additional metrics, in adults with type 1 diabetes (T1D) using the Tandem t:slim X2 with Control-IQ technology advanced hybrid closed-loop (AHCL) system., Methods: This was a single-centre, retrospective study involving 56 T1D patients who transitioned to the Tandem t:slim X2 with Control-IQ system. The primary and secondary endpoints consisted of variations in time in tight range (TiTR; 70-140 mg/dL) and the glycaemia risk index (GRI), respectively. Additional standardized continuous glucose monitoring (CGM) metrics, mean sensor glucose, coefficient of variation, the glucose management indicator (GMI), HbA1c and insulin daily dose, were also evaluated. Variables were measured at baseline and at 15 days, 3 months, 6 months and 1 year after Tandem t:slim X2 Control-IQ initiation. Glucose outcomes are expressed as mean (standard deviation)., Results: Use of Tandem t:slim X2 with Control-IQ over 1 year was associated with an increase in mean TiTR, from 38.11% (17.05%) to 43.10% (13.20%) (P = .059), and with a decline in the GRI, from 41.03 (25.48) to 28.55 (16.27) (P = .008). CGM metrics, including time in range and time above range, showed consistent improvements. Mean sensor glucose, the GMI and HbA1c decreased significantly over time. After an initial increase, insulin daily dose remained stable throughout the 12 months., Conclusions: The results highlight the sustained effectiveness of Tandem t:slim X2 with Control-IQ in improving glycaemic outcomes over 1 year and support the use of this technology for the management of T1D., (© 2024 John Wiley & Sons Ltd.)
- Published
- 2024
- Full Text
- View/download PDF
3. Unmet needs in the treatment of type 1 diabetes: why is it so difficult to achieve an improvement in metabolic control?
- Author
-
Mazzotta FA, Lucaccini Paoli L, Rizzi A, Tartaglione L, Leo ML, Popolla V, Barberio A, Viti L, Di Leo M, Pontecorvi A, and Pitocco D
- Subjects
- Humans, Hypoglycemic Agents therapeutic use, Hypoglycemia prevention & control, Blood Glucose metabolism, Insulin Infusion Systems, Quality of Life, Glycated Hemoglobin metabolism, Glycated Hemoglobin analysis, Diabetes Mellitus, Type 1 drug therapy, Diabetes Mellitus, Type 1 metabolism, Insulin Resistance physiology, Insulin therapeutic use, Glycemic Control methods
- Abstract
The development of advanced diabetes technology has permitted persons with type 1 diabetes mellitus to improve metabolic control significantly, particularly with the development of advanced hybrid closed-loop systems which have improved the quality of life by reducing hypoglycemia, decreasing macroangiopathy and microangiopathy-related complications, ameliorating HbA1c and improving glycemic variability. Despite the progression made over the past few decades, there is still significant margin for improvement to be made in terms of attaining appropriate metabolic control. Various factors are responsible for poor glycemic control including inappropriate carbohydrate counting, repeated bouts of hypoglycemia, hypoglycemia unawareness, cutaneous manifestations due to localized insulin use and prolonged use of diabetes technology, psychosocial comorbidities such as eating disorders or 'diabulimia', the coexistence of insulin resistance among people with type 1 diabetes and the inability to mirror physiological endogenous pancreatic insulin secretion appropriately. Hence, the aim of this review is to highlight and overcome the barriers in attaining appropriate metabolic control among people with type 1 diabetes by driving research into adjunctive treatment for coexistent insulin resistance and developing new advanced diabetic technologies to preserve β cell function and mirror as much as possible endogenous pancreatic functions., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
4. The development and evolution of insulin pumps: from early beginnings to future prospects.
- Author
-
Mazzotta FA, Lucaccini Paoli L, Rizzi A, Tartaglione L, Leo ML, Cristallo F, Popolla V, DI Leo M, Pontecorvi A, and Pitocco D
- Subjects
- Humans, History, 20th Century, Hypoglycemic Agents history, Hypoglycemic Agents administration & dosage, Hypoglycemic Agents therapeutic use, History, 21st Century, Blood Glucose Self-Monitoring history, Blood Glucose Self-Monitoring instrumentation, Insulin Infusion Systems history, Diabetes Mellitus, Type 1 drug therapy, Pancreas, Artificial history, Insulin administration & dosage, Insulin history, Insulin therapeutic use
- Abstract
Diabetes technology has proliferated extensively over the past few decades with vast ameliorations in glucose monitoring and in insulin delivery systems. From a treatment based on daily insulin injections, we have moved to increasingly advanced technologies. Despite such advancements which have allowed better glycemic control, decreased diabetes-related complications, and improved the quality of life among diabetic patients, it has left many individuals unsatisfied with the current rate of commercial artificial pancreas development, stemming the need for further research into novel technologies. Accordingly, the Juvenile Diabetes Research Foundation has marked three generations for the development of an artificial pancreas comprising historical landmarks and future prospects which aim to produce an advanced technological system that attempts to mimic the endogenous pancreas, eliminating the need for user input. This review presents a synopsis of the development and evolution of insulin pumps, starting with the earliest technologies available such as continuous subcutaneous insulin infusion and continuous glucose monitoring as separate components, to currently available integrated advanced closed-loop hybrid systems and possible future technologies. The aim of the review is to provide insight of the advantages and limitations of past and currently available insulin pumps with the hope of driving research into novel technologies that attempt to mimic endogenous pancreatic function as closely as possible.
- Published
- 2024
- Full Text
- View/download PDF
5. How Much Do Young Italians Know About COVID-19 and What Are Their Attitudes Toward SARS-CoV-2? Results of a Cross-Sectional Study.
- Author
-
La Torre G, Lia L, Dorelli B, Marte M, Chiappetta M, Faticoni A, Lucaccini Paoli L, Grassucci D, Gelardini M, and Ardizzone C
- Subjects
- Adolescent, Adult, Child, Cross-Sectional Studies, Female, Humans, Italy epidemiology, Male, Pandemics, Pneumonia, Viral virology, SARS-CoV-2, Surveys and Questionnaires, COVID-19 epidemiology, Health Knowledge, Attitudes, Practice, Pneumonia, Viral epidemiology
- Abstract
Objectives: At the end of 2019, an outbreak of novel coronavirus pneumonia, called severe acute respiratory syndrome coronavirus 1 (SARS-CoV-2), was first identified in Wuhan, Hubei Province, China. It subsequently spread throughout China and elsewhere, becoming a global health emergency. In February 2020, the World Health Organization (WHO) designated the disease coronavirus disease 2019 (COVID-19). The objective of this study was to investigate the degree of knowledge of young Italians about COVID-19 and their current attitudes toward the SARS-CoV-2 and to determine if there were prejudices emerging toward Chinese., Methods: An online survey was conducted on February 3, 4, 5, 2020, with the collaboration of Italian website "Skuola.net". Young people had the opportunity to participate by answering an ad hoc questionnaire created to investigate knowledge and attitudes about the new coronavirus, using a link published on the homepage., Results: A total of 5234 responses were received, of which 3262 were females and 1972 were males. Most of the participants showed generally moderate knowledge about COVID-19. Male students, middle school students, and those who do not attend school, should increase awareness of the disease; less than half of responders say that their attitudes toward the Chinese population has worsened in the last period., Conclusions: Global awareness of this emerging infection should be increased, due to its virulence, the significant risk of mortality, and the ability of the virus to spread very quickly within the community.
- Published
- 2021
- Full Text
- View/download PDF