2. Intraindividueller Vergleich von Dezentrierung, Verkippung und Wellenfront einer trifokalen und einer EDOF-monofokalen Intraokularlinse
- Author
-
Danzinger, V, Schartmüller, D, Schwarzenbacher, L, Röggla, V, Abela-Formanek, C, Menapace, R, Leydolt, C, Danzinger, V, Schartmüller, D, Schwarzenbacher, L, Röggla, V, Abela-Formanek, C, Menapace, R, and Leydolt, C
- Published
- 2023
3. Intraindividuelle Korrelation von Dezentrierung und Verkippung zwischen der kristallinen Linse und einer monofokalen hydrophoben Acryl-Intraokularlinse
- Author
-
Lisy, M, Schartmüller, D, Röggla, V, Schwarzenbacher, L, Abela-Formanek, C, Leydolt, C, Menapace, R, Lisy, M, Schartmüller, D, Röggla, V, Schwarzenbacher, L, Abela-Formanek, C, Leydolt, C, and Menapace, R
- Published
- 2023
4. Rotationsstabilität einer neuen hydrophoben Acryl-Intraokularlinsenplattform
- Author
-
Schartmüller, D, Röggla, V, Schwarzenbacher, L, Leydolt, C, Menapace, R, Schartmüller, D, Röggla, V, Schwarzenbacher, L, Leydolt, C, and Menapace, R
- Published
- 2023
5. Nachstarentwicklung mit zwei hydrophoben Acryl-Intraokularlinsen: Vivinex XY1 vs. Clareon CNA0T0 3-Jahres-Ergebnisse einer randomisierten Studie
- Author
-
Schartmüller, D, Leydolt, C, Schwarzenbacher, L, Röggla, V, Danzinger, V, Lisy, M, Abela-Formanek, C, Menapace, R, Schartmüller, D, Leydolt, C, Schwarzenbacher, L, Röggla, V, Danzinger, V, Lisy, M, Abela-Formanek, C, and Menapace, R
- Published
- 2023
6. Einfluss eines Kapselspannringes auf die postoperative Rotationstabilität einer Plattenhaptik-Intraokularlinse: eine intraindividuelle Vergleichsstudie
- Author
-
Schartmüller, D, Röggla, V, Schwarzenbacher, L, Abela-Formanek, C, Leydolt, C, Menapace, R, Schartmüller, D, Röggla, V, Schwarzenbacher, L, Abela-Formanek, C, Leydolt, C, and Menapace, R
- Published
- 2022
7. Femto-AK-Resultate nach Finite-Elemente-Methode-Operationsplanung
- Author
-
Schwarzenbacher, L, Schartmüller, D, Röggla, V, Abela-Formanek, C, Leydolt, C, Menapace, R, Schwarzenbacher, L, Schartmüller, D, Röggla, V, Abela-Formanek, C, Leydolt, C, and Menapace, R
- Published
- 2022
8. Femto-AK-Resultate nach Finite-Elemente-Methode-Operationsplanung
- Author
-
Schwarzenbacher, Luca, Schartm��ller, D., R��ggla, V., Abela-Formanek, C., Leydolt, C., and Menapace, R.
- Subjects
ddc: 610 ,Medicine and health - Abstract
Hintergrund: Ein unkorrigierter kornealer Astigmatismus von einer Dioptrie oder dar��ber hinaus reduziert die unkorrigierte Sehsch��rfe deutlich. Besonders stark nehmen dies Patienten nach erfolgter Kataraktoperation wahr. Korneale Astigmatismen zwischen 1 und 2 Dioptrien betreffen in etwa ein [zum vollst��ndigen Text gelangen Sie ��ber die oben angegebene URL]
- Published
- 2022
- Full Text
- View/download PDF
9. Astigmatismus-Korrektur mit dem Femtosekundenlaser
- Author
-
Menapace, RM, Schwarzenbacher, L, Schartmüller, D, Roeggla, V, Meyer, E, and Leydolt, C
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Fragestellung: Studium der Reduktion des Astigmatismus und der optischen Qualität der Hornhaut durch femtosekundenlaser (FSL) -assistierte Bogeninzisionen unter Berücksichtigung des refraktiven Gesamtastigmatismus und der Aberrationen höheren Ordnung über ein Jahr. Design: Prospektive[zum vollständigen Text gelangen Sie über die oben angegebene URL], 35. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, interventionelle und refraktive Chirurgie
- Published
- 2021
- Full Text
- View/download PDF
10. Myopie: Prävention und Progressionshemmung
- Author
-
Leydolt, C. and Findl, O.
- Published
- 2007
- Full Text
- View/download PDF
11. Rotationsstabilität einer asphärischen, hydrophoben Intraokularlinse: Acrysof SN60WF
- Author
-
Schartmüller, Daniel, Schriefl, S., Leydolt, C., and Menapace, R.
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Hintergrund: Ziel dieser prospektiv randomisierten Studie war es die Rotationsstabilität einer asphärischen, hydrophoben, Acryl- Intraokularlinse 4-6 Monate postoperativ zu erheben. Methoden: 121 Augen von 63 Patienten erhielten im Zuge der Kataraktoperation eine Acrysof SN60WF Intraokularlinse.[zum vollständigen Text gelangen Sie über die oben angegebene URL], 31. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)
- Published
- 2017
12. Prostaglandinspiegel bei Femtosekundenlaser-assistierter Kataraktchirurgie
- Author
-
Schwarzenbacher, Luca, Schartmüller, D., Leydolt, C., Funk, M., and Menapace, R.
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Hintergrund: Bei der Femtosekunden Laser-assistierten Kataraktchirurgie (FLACS) kommt es zum Anstieg des Prostaglandinspiegels in der Vorderkammer durch Mikroexplosionen im Gewebe. Herkömmliche Femtosekunden-Laser arbeiten mit einer höheren Laserpuls-Energie und einer geringeren Frequenz als[zum vollständigen Text gelangen Sie über die oben angegebene URL], 31. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)
- Published
- 2017
- Full Text
- View/download PDF
13. Prostaglandinspiegel bei Femtosekundenlaser-assistierter Kataraktchirurgie
- Author
-
Schwarzenbacher, L, Schartmüller, D, Leydolt, C, Funk, M, Menapace, R, Schwarzenbacher, L, Schartmüller, D, Leydolt, C, Funk, M, and Menapace, R
- Published
- 2017
14. Rotationsstabilität einer asphärischen, hydrophoben Intraokularlinse: Acrysof SN60WF
- Author
-
Schartmüller, D, Schriefl, S, Leydolt, C, Menapace, R, Schartmüller, D, Schriefl, S, Leydolt, C, and Menapace, R
- Published
- 2017
15. Einfluss eines Kapselspannringes auf die Rotation einer Kunstlinse
- Author
-
Schriefl, Sabine, Schartmüller, D., Leydolt, C., and Menapace, R.
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Hintergrund: Ziel dieser Studie war die Beobachtung des Einflusses eines Kapselspannringes (HumanOptics CTR 13/11) auf die Rotation einer single-piece Kunstlinse mit offenen Schlaufenhaptiken aus hydrophilem Akryl (Human Optics Aspira-aA, ehemals MC 6125 AS). Methoden: Nach dem Ende der Operation[zum vollständigen Text gelangen Sie über die oben angegebene URL], 30. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)
- Published
- 2016
16. Vergleich zwischen Acryl- und Silikon-Intraokularlinsen: Nachstarentstehung 4 Jahre postoperativ
- Author
-
Schartmüller, D, Leydolt, C, Schriefl, S, Menapace, R, Schartmüller, D, Leydolt, C, Schriefl, S, and Menapace, R
- Published
- 2016
17. Einfluss eines Kapselspannringes auf die Rotation einer Kunstlinse
- Author
-
Schriefl, S, Schartmüller, D, Leydolt, C, Menapace, R, Schriefl, S, Schartmüller, D, Leydolt, C, and Menapace, R
- Published
- 2016
18. Vergleich des Materialeffektes von hydophobem Akryl bzw. Silikon bei 3 stückigen Kunstlinsen auf die Nachstarbildung
- Author
-
Schriefl, SM, Leydolt, C, Stifter, E, and Menapace, RM
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Fragestellung: Vergleich der Tendenz zur Nachstarentwicklung und der Frequenz der Nd:YAG Behandlungen bei zwei unterschiedlichen IOLs: Einer dreiteiligen Linse mit einer Optik aus hydrophobem Akryl und C-Schlaufen Haptiken aus PMMA (KSXS) und einer dreiteiligen Linse mit einer Optik aus Silikon und [for full text, please go to the a.m. URL], 28. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)
- Published
- 2014
- Full Text
- View/download PDF
19. Vergleich von Nachstar- und YAG- Kapsulotomie-Rate zwischen der Tecnis ZCB00 und Acrysof SA60AT einstückigen hydrophoben Acryl-Intraokularlinsen
- Author
-
Leydolt, C, Kriechbaum, K, Schriefl, S, Pachala, M, and Menapace, R
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Fragestellung: Ziel dieser prospektiven randomisierten Studie war ein Vergleich von Inzidenz und Intensität des Nachstars zwischen zwei ähnlichen ein-stückigen hydrophoben Acryl-Intraokularlinsen (IOLs), mit unterschiedlichen Materialeigenschaften und Linsenkanten-Designs über einen[for full text, please go to the a.m. URL], 27. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation, Interventionelle und Refraktive Chirurgie (DGII)
- Published
- 2013
- Full Text
- View/download PDF
20. Three-dimensional imaging and volumetry of retinal nerve fibre layer and ganglion cell layer using high resolution optical coherence tomography in patients with glaucoma
- Author
-
Hirn, C, Vass, C, Geitzenauer, W, Simader, C, Ahlers, C, Aue, A, Leydolt, C, and Schmidt-Erfurth, U
- Subjects
ddc: 610 - Published
- 2006
21. Prospektive Vergleichsstudie der Nachstarentwicklung zwischen zwei unterschiedlichen Mikroinzisionslinsen - Langzeitergebnisse
- Author
-
Schriefl, SM, Leydolt, C, Stifter, E, Menapace, R, Schriefl, SM, Leydolt, C, Stifter, E, and Menapace, R
- Published
- 2013
22. Dreidimensionale Bildgebung und Volumetrie der retinalen Nervenfaserschicht und Ganglienzellschicht mittels hochauflösender, schnellscannender optischer Kohärenztomographie bei Patienten mit Glaukom
- Author
-
Hirn, C, Vass, C, Geitzenauer, W, Simader, C, Ahlers, C, Aue, A, Leydolt, C, Schmidt-Erfurth, U, Hirn, C, Vass, C, Geitzenauer, W, Simader, C, Ahlers, C, Aue, A, Leydolt, C, and Schmidt-Erfurth, U
- Published
- 2006
23. Effects of change in intraocular pressure on axial eye length and lens position
- Author
-
Leydolt, C, primary, Findl, O, additional, and Drexler, W, additional
- Published
- 2007
- Full Text
- View/download PDF
24. Effects of change in intraocular pressure on axial eye length and lens position.
- Author
-
Leydolt, C., Findl, O., and Drexler, W.
- Subjects
- *
PREDICATE calculus , *BIOMETRIC research , *VISUAL accommodation , *OPTICAL measurements , *INTRAOCULAR pressure , *EYE diseases , *ETIOLOGY of diseases - Abstract
PurposeTo quantify the biometric changes of ocular dimensions with mechanical elevation of intraocular pressure (IOP) in vivo, to get a better understanding of the elastic properties of the human ocular structures that may play a role in the pathogenesis of various diseases such as myopia or glaucoma.MethodsChanges in IOP were induced by a suction cup in 18 eyes under cycloplegia. Axial eye length (AEL) and anterior chamber depth (ACD) were measured with non-invasive laser interferometry during elevation of the IOP 10 and 20 mmHg over baseline values and after a 10-min resting period.ResultsIOP elevation of 10 and 20 mmHg respectively caused a significant increase of AEL of 23 μm (95% confidence interval: 14–34 μm) and 39 μm (confidence interval (CI): 28–51 μm). After mechanical oculopression, which resulted in an IOP reduction of –5.1 mmHg (CI: −6.3 to −4.0 mmHg) vsbaseline, a significant shortening of −7 μm (CI: −13 to 0 μm) was observed. The change in AEL correlated with the change in IOP (r=0.66, P=0.005). Furthermore, a significant increase in ACD of 30 μm (CI: 24–36 μm) was detected with IOP reduction after oculopression, but no change was seen during IOP elevation.ConclusionsBiometric changes of the human eye as a response to IOP changes were assessed in vivo. The correlation between change in AEL and IOP found emphasizes the need of in vivoocular rigidity measurements in the human eye.Eye (2008) 22, 657–661; doi:10.1038/sj.eye.6702709; published online 19 January 2007 [ABSTRACT FROM AUTHOR]
- Published
- 2008
- Full Text
- View/download PDF
25. Assessing Postoperative Toric Intraocular Lens Rotation: A Comparative Analysis.
- Author
-
Lisy M, Danzinger V, Schranz M, Mahnert N, Abela-Formanek C, Leydolt C, Menapace R, and Schartmüller D
- Abstract
Purpose: To investigate the accuracy of three distinct postoperative toric intraocular lens (TIOL) rotational stability measurement methods., Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Austria., Design: Single-center, prospective, interventional clinical trial., Methods: 128 eyes of 81 patients with age-related cataract received a hydrophobic acrylic TIOL Clareon CNW0T3-9. To evaluate rotational stability, three distinct assessment methods were used: (Rotix) comparing the TIOL axis at the end of surgery (EoS) to 1 week (1w) and 6 months (6m) postoperatively using reference vessels at the sclera, (Slit-lamp) comparing the intended axis (IA) with the axis at 1w and 6m using slit-lamp photography using the horizontal axis as a reference and (Casia) comparing the IA with the axis at 1w and 6m using the axis determination tool of a swept-source anterior segment optical coherence tomographer (Casia 2)., Results: Mean absolute rotation from EoS/IA to 6m differed significantly among Rotix (1.33± 1.99° [0.01;19.80]), Casia (2.88± 2.64° [0.00; 19.00]), and Slit-lamp (4.38± 3.38° [0.02;19.38]), as indicated by Friedman's test (X2=71.852, p<0.001). Bland-Altman coefficients (CoR) of repeatability indicated the closest agreement of results between Casia and Rotix, with a CoR of ±3.95°, followed by Slit-lamp and Casia (±6.82°), and lastly, between the Slit-lamp and Rotix (±7.19°)., Conclusion: When assessing true TIOL rotational stability, it is imperative to use fixed anatomical landmarks as reference and establish a baseline at the end of surgery. When assessing TIOL rotation along the horizontal axis, considering cyclorotation of the eye is crucial and must not be underestimated., (Copyright © 2024 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.)
- Published
- 2024
- Full Text
- View/download PDF
26. Fellow-Eye Comparison of Monocular Visual Outcomes Following Monofocal Extended Depth-of-Focus (EDOF) and Trifocal EDOF Intraocular Lens Implantation.
- Author
-
Danzinger V, Schartmüller D, Lisy M, Schranz M, Schwarzenbacher L, Abela-Formanek C, Menapace R, and Leydolt C
- Subjects
- Humans, Prospective Studies, Male, Female, Aged, Surveys and Questionnaires, Middle Aged, Multifocal Intraocular Lenses, Prosthesis Design, Contrast Sensitivity physiology, Glare, Aged, 80 and over, Visual Acuity physiology, Lens Implantation, Intraocular, Depth Perception physiology, Vision, Monocular physiology, Phacoemulsification, Pseudophakia physiopathology, Lenses, Intraocular
- Abstract
Purpose: To compare intraindividual monocular visual performance of a monofocal extended depth-of-focus (EDOF) and a trifocal EDOF intraocular lens (IOL) following bilateral cataract surgery., Design: Single-center, prospective, fellow-eye comparison clinical trial., Methods: All patients received uneventful bilateral cataract surgery with implantation of the monofocal EDOF Isopure IOL in the dominant eye and the trifocal EDOF FineVision Triumf IOL in the nondominant eye. Intraindividual monocular comparison included visual acuity at various distances, defocus curves, internal total higher-order aberration (HOA), spherical aberration (SA) Z(4.0), IOL decentration, and tilt. Additionally, subjective outcomes were evaluated using Halo and Glare simulation and the Seven-Item Visual-Functioning Index questionnaire., Results: In total, 25 patients (50 eyes) were included. Intraindividual monocular best-corrected distance visual acuity, distance-corrected intermediate visual acuity, and best-corrected near visual acuity were comparable (P > .05). However, monocular contrast acuity (P = .019), distance-corrected near visual acuity (P < .001), and defocus curves at defocus levels of 0.0 D (P = .005) and between -1.5 and -4.0 D (P < .001) differed significantly. At 5 mm, internal HOA and SA Z(4.0) were significantly different (P < .001) and comparable at 3-mm pupil diameter, as were IOL tilt and decentration (P > .05)., Conclusion: In this combined fellow-eye comparison, near vision was significantly better with the trifocal EDOF IOL. The monofocal EDOF IOL demonstrated similar distance and intermediate visual performance as the trifocal EDOF IOL. Overall, low values of photic phenomena and visual impairment were observed., (Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
27. Posterior capsule opacification with two similar-design hydrophobic acrylic intraocular lenses: 3-year results of a randomized controlled trial.
- Author
-
Leydolt C, Schartmüller D, Schwarzenbacher L, Prenner V, Danzinger V, Lisy M, Abela-Formanek C, and Menapace R
- Abstract
Purpose: To compare intraindividually the incidence and intensity of posterior capsule opacification (PCO) and Nd:YAG capsulotomy rates between two similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) differing slightly in their particular material, optic surface and sharp posterior edge design over a period of 3 years., Setting: Department of Opthalmology, Medical University Vienna., Design: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison., Methods: 100 patients randomly received a Vivinex XY1 IOL in one eye and a Clareon CNA0T0 IOL in the fellow eye. The amount of PCO (score: 0 - 10) was assessed subjectively and objectively with digital retroillumination picturs using automated image analysis software (AQUA). Best-corrected distance visual acuity (CDVA) as well as the presence of glistenings, subjective visual symptoms and Nd:YAG laser capsulotomy rate were noted., Results: 67 of 100 patients were available for the 3-years follow-up examination. The objective PCO score of the Vivinex XY1 IOLs was 1.0 ± 1.0 compared to the PCO score of 1.5 ± 1.2 for the Clareon CNA0T0 IOLs (p < 0.001). 7.5% of patients had a neodymium:yttrium-aluminium-garnet (Nd:YAG) capsulotomy in the Vivinex XY1 eye, and 9.0% had a capsulotomy in the Clareon CNA0T0 eye (p = 1.0)., Conclusion: Both hydrophobic acrylic IOLs showed low PCO and YAG rates with a small but significant favor of the Vivinex XY1 IOL compared to the Clareon CNA0T0 IOL. The interaction of various factors such as hydrophobic material, smooth optic surface and sharp posterior optic edge is the major key for PCO prevention., (Copyright © 2024 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of ASCRS and ESCRS.)
- Published
- 2024
- Full Text
- View/download PDF
28. Long-term impact of low-energy femtosecond laser and manual cataract surgery on macular layer thickness: A prospective randomized study.
- Author
-
Schwarzenbacher L, Schmidt-Erfurth U, Schartmüller D, Röggla V, Leydolt C, Menapace R, and Reiter GS
- Subjects
- Humans, Prospective Studies, Female, Male, Aged, Follow-Up Studies, Middle Aged, Time Factors, Macular Edema etiology, Macular Edema diagnosis, Macular Edema surgery, Aged, 80 and over, Visual Acuity, Tomography, Optical Coherence methods, Cataract Extraction methods, Laser Therapy methods, Macula Lutea diagnostic imaging, Macula Lutea pathology
- Abstract
Purpose: To evaluate change in retinal layers 18 months after femtosecond laser-assisted cataract surgery (LCS) and manual cataract surgery (MCS) in a representative age-related cataract population using artificial intelligence (AI)-based automated retinal layer segmentation., Methods: This was a prospective, randomized and intraindividual-controlled study including 60 patients at the Medical University of Vienna, Austria. Bilateral same-day LCS and MCS were performed in a randomized sequence. To provide insight into the development of cystoid macular oedema (CME), retinal layer thickness was measured pre-operatively and up to 18 months post-operatively in the central 1 mm, 3 mm and 6 mm., Results: Fifty-six patients completed all follow-up visits. LCS compared to MCS did not impact any of the investigated retinal layers at any follow-up visit (p > 0.05). For the central 1 mm, a significant increase in total retinal thickness (TRT) was seen after 1 week followed by an elevated plateau thereafter. For the 3 mm and 6 mm, TRT increased only after 3 weeks and 6 weeks and decreased again until 18 months. TRT remained significantly increased compared to pre-operative thickness (p < 0.001). Visual acuity remained unaffected by the macular thickening and no case of CME was observed. Inner nuclear layer (INL) and outer nuclear layer (ONL) were the main causative layers for the total TRT increase. Photoreceptors (PR) declined 1 week after surgery but regained pre-operative values 18 months after surgery., Conclusion: Low-energy femtosecond laser pre-treatment did not influence thickness of the retinal layers in any topographic zone compared to manual high fluidic phacoemulsification. TRT did not return to pre-operative values 18 months after surgery. The causative layers for subclinical development of CME were successfully identified., (© 2024 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.)
- Published
- 2024
- Full Text
- View/download PDF
29. Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens.
- Author
-
Schartmüller D, Lisy M, Mahnert N, Schranz M, Danzinger V, Schwarzenbacher L, Pieh S, Abela-Formanek C, Leydolt C, and Menapace R
- Abstract
Purpose: To assess rotational stability and refractive outcomes of a new toric hydrophobic acrylic intraocular lens (IOL)., Design: Single-center, prospective, interventional clinical trial., Methods: A total of 130 eyes of 82 patients with age-related cataract and total corneal astigmatism of greater than 1.0 diopters (D) received a hydrophobic acrylic toric IOL Clareon CNW0T3-9. Baseline measurement for rotational stability evaluation was performed at the end of surgery (EOS), with the patient still supine on the operating table, using non-movable vessels as reference landmarks. Postoperative retroillumination pictures were taken at 1 h, 1 week, 1 month and 4-6 months postoperatively. Subjective manifest refraction was assessed at the 6 months follow-up visit., Results: Final results were obtained in 126 eyes of 80 patients. Mean absolute rotation from EOS to 6 months was 1.33 ± 2.00 [0.01, 19.80] degrees. Rotational stability values from EOS to 1 h, 1 h to 1 week, 1 week to 1 month and 1 month to 6 months were 0.86 ± 0.82 [0.00, 3.90], 1.06 ± 1.94 [0.00, 19.45], 0.47 ± 0.42 [0.00, 2.03] and 0.38 ± 0.40 [0.00, 2.56] degrees. Mean preoperative corneal astigmatism was 1.78 ± 0.83 [1.00, 4.76] D which changed to a mean postoperative refractive astigmatism of 0.33 ± 0.27 [0.00, 1.25] D at 6 months., Conclusion: The Clareon toric IOL presented very good rotational stability with a mean absolute rotation below 1.4° from EOS to 6 months. Only two IOLs rotated more than 5° with none of them requiring repositioning surgery. Refractive outcomes were satisfying with a mean residual refractive astigmatism below 0.50 D., Trial Registration: Registered at Clinicaltrials.gov NCT03803852 ; on May 17, 2022., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
30. Intraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform.
- Author
-
Danzinger V, Schartmüller D, Lisy M, Schranz M, Schwarzenbacher L, Abela-Formanek C, Menapace R, and Leydolt C
- Subjects
- Humans, Lens Implantation, Intraocular, Prospective Studies, Visual Acuity, Prosthesis Design, Patient Satisfaction, Diabetic Retinopathy, Lenses, Intraocular, Phacoemulsification
- Abstract
Purpose: To compare intraindividual differences in visual performance of a monofocal and enhanced monofocal intraocular lens (IOL) of the same platform., Design: Prospective, interventional, fellow-eye comparison clinical study., Methods: In total, 55 patients (110 eyes) with bilateral age-related cataract were enrolled. All patients received a monofocal ZCB00 IOL in the dominant and an enhanced monofocal Eyhance ICB00 IOL in the nondominant eye. After 2 to 4 months, monocular best-corrected distant visual acuity (BCDVA), distance-corrected intermediate visual acuity (DCIVA), distance-corrected near visual acuity (DCNVA), contrast visual acuity, monocular defocus curves, internal higher-order aberrations (HOAs) and spherical aberrations (SA), decentration, and tilt were compared., Results: The monocular mean BCDVA, DCIVA at 80 cm and 66 cm, and DCNVA were -0.03 ± 0.07, 0.24 ± 0.12, 0.32 ± 0.13, and 0.50 ± 0.13 logarithm of the minimum angle of resolution for the enhanced ICB00 and -0.06 ± 0.06 (P = .014), 0.30 ± 0.11 (P = .005), 0.38 ± 0.12 (P = .004), and 0.55 ± 0.14 (P = .034) logarithm of the minimum angle of resolution for the ZCB00, respectively. Internal HOAs (P = .001) and negative SA (P < .001) were increased with the ICB00 at 3 mm and comparable at 5 mm (P > .05). Contrast acuity, tilt, and decentration were similar (P > .05)., Conclusions: Significantly increased monocular DCIVA at 80 cm and 66 cm and DCNVA at 40 cm were observed with the enhanced ICB00 IOL, and the ZCB00 IOL demonstrated better BCDVA. This would result in a mean gain of 2 to 3 Early Treatment of Diabetic Retinopathy Study letters at near and intermediate distance. Monocular defocus curves displayed highest differences of 5 Early Treatment of Diabetic Retinopathy Study letters at -1.25 diopters (D) and -1.50 D levels of defocus and a depth of focus of 1.23 D for the ICB00 IOL and 0.94 D for the ZCB00 IOL. Decentration, tilt, and HOAs were generally low., (Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
31. Influence of a Capsular Tension Ring on Capsular Bag Behavior of a Plate Haptic Intraocular Lens: An Intraindividual Randomized Trial.
- Author
-
Schartmüller D, Röggla V, Schwarzenbacher L, Meyer EL, Abela-Formanek C, Leydolt C, and Menapace R
- Subjects
- Humans, Lens Implantation, Intraocular methods, Haptic Technology, Phacoemulsification methods, Lenses, Intraocular, Lens Capsule, Crystalline surgery, Cataract
- Abstract
Purpose: To evaluate the influence of a capsular tension ring (CTR) on rotational stability, decentration, tilt, and axial stability of an 11.0-mm plate haptic intraocular lens (IOL)., Design: Intraindividual, randomized, double-masked, controlled clinical trial., Participants: Patients scheduled for sequential same-day bilateral cataract surgery., Methods: All patients were randomized to receive a CTR and a plate haptic IOL in one eye and a plate haptic IOL in the fellow eye only. Intraocular lens axis assessment was performed at the end of surgery, 1 hour, 1 week, 1 month, and 6 months using a high-precision evaluation method. Decentration and tilt of the crystalline and pseudophakic lenses were assessed before surgery and at 1 week and 6 months using an anterior segment OCT., Main Outcome Measures: Rotational stability from the end of surgery to 6 months and at all follow-up visits, decentration and tilt at 6 months, and differences in axial shift between 1 week and 6 months., Results: One hundred thirty eyes of 65 patients were included in the study. Absolute rotation from the end of surgery to 6 months was 2.8 ± 3.9° and 3.2 ± 5.3° for the CTR and control groups, respectively (P = 0.613). Intraocular lens decentration and IOL tilt at 6 months were 0.29 ± 0.1 mm and 0.24 ± 0.1 mm and 6.7 ± 2.8° and 5.6 ± 1.6° for the CTR and control groups, respectively (P = 0.058; P < 0.01). A posterior IOL shift of 0.31 ± 0.31 mm and 0.19 ± 0.14 mm was observed in the CTR and control groups, respectively., Conclusions: Concomitant implantation of a CTR and a plate haptic IOL did not improve the overall rotational stability of the IOL compared with the control group. Against expectations, higher values of decentration, tilt, and axial shift were observed in the CTR group. The simultaneous use of a CTR and a plate haptic IOL in the absence of zonular weakness at the time of cataract surgery should be considered with caution., Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article., (Copyright © 2023 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
32. Clinical prospective intra-individual comparison after mix-and-match implantation of a monofocal EDOF and a diffractive trifocal IOL.
- Author
-
Danzinger V, Schartmüller D, Schwarzenbacher L, Röggla V, Abela-Formanek C, Menapace R, and Leydolt C
- Subjects
- Humans, Lens Implantation, Intraocular, Vision, Binocular, Prospective Studies, Prosthesis Design, Patient Satisfaction, Refraction, Ocular, Pseudophakia, Lenses, Intraocular, Phacoemulsification
- Abstract
Objectives: To assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL., Methods: The monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator., Results: 50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of -1.5D to -4.0D (p < 0.01), the monofocal EDOF IOL was better at -0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained., Conclusion: Excellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low., (© 2023. The Author(s), under exclusive licence to The Royal College of Ophthalmologists.)
- Published
- 2024
- Full Text
- View/download PDF
33. Best fit formula approach in delayed sequential bilateral cataract surgery.
- Author
-
Röggla V, Langenbucher A, Leydolt C, Schartmüller D, Schwarzenbacher L, Hoffmann P, and Menapace R
- Subjects
- Humans, Lens Implantation, Intraocular, Refraction, Ocular, Retrospective Studies, Biometry, Optics and Photonics, Axial Length, Eye, Lenses, Intraocular, Cataract complications, Phacoemulsification
- Abstract
Background: We evaluated whether the best-fit intraocular lens (IOL) power formula for the first operated eye (BF1) was also the most accurate formula for the second eye., Methods: This was a retrospective study of 152 patients who underwent uncomplicated delayed bilateral cataract surgery with a minimum delay of 3 weeks using only one 1-piece IOL (HOYA, Vivinex) at the Medical University of Vienna, Austria. Seven different formulae (Barrett Universal II, Castrop, Haigis, Hoffer Q, Holladay 1, Kane, and SRK/T) were investigated to test the formula selection approach with regard to the calculated mean and median absolute prediction errors (MAE/MedAE)., Results: The mean intraindividual difference in axial length was 0.2 mm (±0.3 mm). BF1 coincided with the best-fit formula for the second eye (BF2) in 56% of patients (p < 0.05). Using BF1 for the second eye led to a lower MedAE (0.22 dioptre, D) than using a formula at random (0.33 D) and was less accurate than using the best-fit formula for each eye separately (0.1 D). The MedAEs of all formulae were generally low, ranging from 0.28 to 0.35 D., Conclusion: Using BF1 for the second eye led to a lower MedAE than the random selection of a formula. Therefore, BF1 can be used for the second eye if the surgeon is unsure of the choice of formula., (© 2023 The Authors. Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.)
- Published
- 2023
- Full Text
- View/download PDF
34. Rotational Stability, Decentration, and Tilt of a New Hydrophobic Acrylic Intraocular Lens Platform.
- Author
-
Röggla V, Schartmüller D, Schwarzenbacher L, Leydolt C, and Menapace R
- Subjects
- Humans, Lens Implantation, Intraocular, Prospective Studies, Fibrosis, Phacoemulsification, Lenses, Intraocular, Cataract
- Abstract
Purpose: To evaluate rotational stability, decentration and tilt of the monofocal intraocular lens (IOL) Nanex (NC1-SP; HOYA Surgical Optics)., Design: Prospective interventional case series., Methods: The study was performed at the Department of Ophthalmology, Medical University of Vienna. The study population comprised 130 eyes of 68 patients with age-related cataract who underwent cataract surgery with implantation of a Nanex IOL. Baseline image for rotational stability evaluation was obtained at the end of surgery (EoS) and compared to retroillumination images taken at 1 hour, 1 week, 1 month, and 6 months after surgery. Axis alignment was assessed using nonmovable landmarks on the sclera and the optic-haptic junctions of the IOL. Anterior segment OCT images were performed to evaluate decentration and tilt. The main outcome measure was absolute rotation from EoS to 6 months postoperatively., Results: Median IOL rotation of all eyes from EoS to 6 months was 1.9° (interquartile range 0.1°-37.5°). Ten eyes (9.71%) rotated more than 5° and 2 eyes (1.94%), more than 10°. IOL rotation did not correlate with axial eye length (Spearman r = -0.042, P = .46), crystalline lens thickness (Spearman r = 0.134, P = .19), and crystalline lens equatorial diameter (Spearman r = 0.101, P = .325). IOL rotation positively correlated with anterior fibrosis severity (Spearman r = 0.321, P = .002). Preoperative decentration (0.2 ± 0.12 mm) and tilt (5.7 ± 1.6°) did not change significantly after surgery (0.22 ± 0.12 mm and 5.62 ± 1.49°, respectively)., Conclusion: The investigated IOL presented good rotational stability and low decentration and tilt values. Nevertheless, anterior capsule fibrosis development led to a higher tendency of IOL rotation after 1 week., (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
35. Automatic segmentation of intraocular lens, the retrolental space and Berger's space using deep learning.
- Author
-
Schwarzenbacher L, Seeböck P, Schartmüller D, Leydolt C, Menapace R, and Schmidt-Erfurth U
- Subjects
- Humans, Lens Implantation, Intraocular, Artificial Intelligence, Cross-Sectional Studies, Tomography, Optical Coherence methods, Deep Learning, Lenses, Intraocular
- Abstract
Purpose: To develop and validate a deep learning model to automatically segment three structures using an anterior segment optical coherence tomography (AS-OCT): The intraocular lens (IOL), the retrolental space (IOL to the posterior lens capsule) and Berger's space (BS; posterior capsule to the anterior hyaloid membrane)., Methods: An artificial intelligence (AI) approach based on a deep learning model to automatically segment the IOL, the retrolental space, and BS in AS-OCT, was trained using annotations from an experienced clinician. The training, validation and test set consisted of 92 cross-sectional OCT slices, acquired in 47 visits from 41 eyes. Annotations from a second experienced clinician in the test set were additionally evaluated to conduct an inter-reader variability analysis., Results: The AI model achieved a Precision/Recall/Dice score of 0.97/0.90/0.93 for IOL, 0.54/0.65/0.55 for retrolental space, and 0.72/0.58/0.59 for BS. For inter-reader variability, Precision/Recall/Dice values were 0.98/0.98/0.98 for IOL, 0.74/0.59/0.62 for retrolental space, and 0.58/0.57/0.57 for BS. No statistical differences were observed between the automated algorithm and the inter-reader variability for BS segmentation., Conclusion: The deep learning model allows for fully automatic segmentation of all investigated structures, achieving human-level performance in BS segmentation. We, therefore, expect promising applications of the algorithm with particular interest in BS in automated big data analysis and real-time intra-operative support in ophthalmology, particularly in conjunction with primary posterior capsulotomy in femtosecond laser-assisted cataract surgery., (© 2022 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.)
- Published
- 2022
- Full Text
- View/download PDF
36. Similarity of eyes in a cataractous population-How reliable is the biometry of the fellow eye for lens power calculation?
- Author
-
Langenbucher A, Szentmáry N, Cayless A, Röggla V, Leydolt C, Wendelstein J, and Hoffmann P
- Subjects
- Axial Length, Eye, Biometry methods, Cornea, Humans, Refraction, Ocular, Cataract, Lens, Crystalline, Lenses, Intraocular
- Abstract
Background: In some situations it is necessary to use biometry from the fellow eye for lens power calculation prior to cataract surgery. The purpose of this study was to analyse the lateral differences in biometric measurements and their impact on the lens power calculation., Methods: The analysis was based on a large dataset of 19,472 measurements of 9736 patients prior to cataract surgery with complete biometric data of both left and right eyes extracted from the IOLMaster 700. After randomly indexing the left or right eye as primary (P) and secondary (S), the differences between S and P eye were recorded and analysed (Keratometry (RSEQ), total keratometry (TRSEQ) and back surface power (BRSEQ)), axial length AL, corneal thickness CCT, anterior chamber depth ACD, lens thickness LT). Lens power was calculated with the Castrop formula for all P and S eyes, and the refraction was predicted using both the P and S eye biometry for the lens power calculation., Results: Lateral differences (S-P, 90% confidence interval) ranged between -0.64 to 0.63 dpt / -0.67 to 0.66 dpt / -0.12 to 0.12 dpt for RSEQ / TRSEQ / BRSEQ. The respective difference in AL / CCT / ACD / LT ranged between -0.46 to 0.43 mm / -0.01 to 0.01 mm / -0.20 to 0.20 mm / -0.13 to 0.14 mm. The resulting difference in lens power and predicted refraction ranged between -2.02 to 2.00 dpt and -1.36 to 1.30 dpt where the biometry of the S eye is used instead of the P eye. The AL and RSEQ were identified as the most critical parameters where the biometry of the fellow eye is used., Conclusion: Despite a strong similarity of both eyes, intraocular lens power calculation with fellow eye biometry could yield different results for the lens power and finally for the predicted refraction. In 10% of cases, the lens power derived from the S eye deviates by 2 dpt or more, resulting in a refraction deviation of 1.36 dpt or more., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2022
- Full Text
- View/download PDF
37. Prostaglandin Release After Low-Energy Femtosecond Laser-Assisted Cataract Surgery Without Anti-Inflammatory Drug Premedication.
- Author
-
Schwarzenbacher L, Schartmüller D, Leydolt C, and Menapace R
- Subjects
- Anti-Inflammatory Agents, Non-Steroidal therapeutic use, Humans, Lasers, Premedication, Prospective Studies, Prostaglandins, Prostaglandins E, Cataract drug therapy, Cataract Extraction, Laser Therapy, Phacoemulsification
- Abstract
Purpose: To compare prostaglandin E2 (PGE-2) levels in the aqueous and pupil diameter in patients undergoing low-pulse energy femtosecond laser-assisted cataract surgery (LCS) without non-steroidal anti-inflammatory (NSAID) pretreatment with either fragmentation or capsulotomy performed first., Design: Prospective, randomized, fellow-eye controlled comparison., Methods: This study was undertaken at the Department of Ophthalmology, Medical University of Vienna. The population consisted of 140 eyes of 70 patients with bilateral age-related cataract. Bilateral same-day LCS with either anterior capsulotomy before lens fragmentation (Caps-First) in one eye or vice versa (Frag-First) in a random sequence were performed. Aqueous was tapped 5 minutes after LCS and PGE-2 concentration was analyzed. Pupil diameters were recorded immediately before and after femtosecond laser pretreatment. The main outcome measure was PGE-2 concentrations in picograms/milliliter and pupil diameter in millimeters., Results: Mean PGE-2 concentrations were 42.0 ± 63.7 pg/mL in the Caps-First group versus 71.8 ± 160.7 pg/mL with the Frag-First group (P = .186). Mean pupil diameters before and after pretreatment were 7.6 ± 0.8 mm and 7.6 ± 0.8 mm, respectively (P = .871). Mean PGE-2 concentrations and pupil diameters did not show any significant difference between time points or groups., Conclusions: Low-energy femtosecond laser pretreatment did not increase PGE-2 levels in the absence of NSAID pretreatment. This was independent of whether capsulotomy or fragmentation was performed first. Moreover, no pupillary miosis was observed., (Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
38. Ultrasound energy consumption and macular changes with manual and femtolaser-assisted high-fluidics cataract surgery: a prospective randomized comparison.
- Author
-
Menapace R, Schartmüller D, Röggla V, Reiter GS, Leydolt C, and Schwarzenbacher L
- Subjects
- Aged, Double-Blind Method, Female, Humans, Macula Lutea diagnostic imaging, Male, Middle Aged, Prospective Studies, Tomography, Optical Coherence, Ultrasonography, Laser Therapy methods, Macula Lutea pathology, Phacoemulsification methods
- Abstract
Purpose: The purpose of the study was to compare ultrasound (US) consumption and central macular thickness (CMT) and volume changes with manual and femtosecond laser (FSL)-assisted cataract nucleus workup., Methods: Sixty patients scheduled for immediate sequential bilateral surgery underwent a prospective randomized intraindividual comparison of nucleus sector fragmentation performed manually in one eye and with low-energy FSL assistance in the partner eye, followed by high-fluidics phacoaspiration with a maximum US power of 30%. Ultrasound (US) energy consumption and macular thickness and volume were compared as measured by intraoperative effective phacoemulsification time (EPT) and high-resolution spectral domain optical coherence tomography pre- and 1 week, 3 weeks and 6 weeks postoperatively. Results are presented as means ± SD or medians [min; max]., Results: Fifty-two patients completed the full follow-up. For the manual and FSL-assisted groups, nuclear hardness was almost identical with a mean LOCS III grade of 2.44 ± 1.08 and 2.50 ± 1.00 (p = 0.371). Median EPT was 1.40 [0.2; 8.3] and 1.25 [0.2; 9.4] seconds. Median preoperative CMT was 276.50 [263.25; 289.75] µm and 276.00 [262.00; 290.00] µm. Median postoperative CMT was 278.00 [260.50; 288.00] versus 275.50 [264.00; 290.50] µm at 1 week, 279.50 [266.75; 292.25] versus 280.00 [266.50; 294.50] µm at 3 weeks and 280.50 [268.00, 293.75] versus 279.50 [264.75; 295.25] µm at 6 weeks. Differences in CMT and total macular volume between the groups were not statistically significant at any point in time., Conclusion: Femtosecond laser (FSL) prefragmentation of the nucleus into six sectors did not reduce US energy consumption compared with manual splitting of the nucleus into four quadrants in this particular surgical setting. Sectorial FSL-prechopping with the low-energy FSL used had no additional impact on postoperative macular thickness and volume., (© 2021 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.)
- Published
- 2022
- Full Text
- View/download PDF
39. Accuracy of common IOL power formulas in 611 eyes based on axial length and corneal power ranges.
- Author
-
Röggla V, Langenbucher A, Leydolt C, Schartmüller D, Schwarzenbacher L, Abela-Formanek C, and Menapace R
- Subjects
- Axial Length, Eye, Biometry methods, Cornea, Humans, Lens Implantation, Intraocular, Optics and Photonics, Refraction, Ocular, Retrospective Studies, Lenses, Intraocular, Phacoemulsification methods
- Abstract
Aims: To provide clinical guidance on the use of intraocular lens (IOL) power calculation formulas according to the biometric parameters., Methods: 611 eyes that underwent cataract surgery were retrospectively analysed in subgroups according to the axial length (AL) and corneal power (K). The predicted residual refractive error was calculated and compared to evaluate the accuracy of the following formulas: Haigis, Hoffer Q, Holladay 1 and SRK/T. Furthermore, the percentages of eyes with ≤±0.25, ≤±0.5 and 1 dioptres (D) of the prediction error were recorded., Results: The Haigis formula showed the highest percentage of cases with ≤0.5 D in eyes with a short AL and steep K (90%), average AL and steep cornea (73.2%) but also in long eyes with a flat and average K (65% and 72.7%, respectively). The Hoffer Q formula delivered the lowest median absolute error (MedAE) in short eyes with an average K (0.30 D) and Holladay 1 in short eyes with a steep K (Holladay 1 0.24 D). SRK/T presented the highest percentage of cases with ≤0.5 D in average long eyes with a flat and average K (80.5% and 68.1%, respectively) and the lowest MedAE in long eyes with an average K (0.29 D)., Conclusion: Overall, the Haigis formula shows accurate results in most subgroups. However, attention must be paid to the axial eye length as well as the corneal power when choosing the appropriate formula to calculate an IOL power, especially in eyes with an unusual biometry., Competing Interests: Competing interests: None declared., (© Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.)
- Published
- 2021
- Full Text
- View/download PDF
40. Rotational Stability of Intraocular Lenses: A Standardized Method for More Accurate Measurements in Future Studies.
- Author
-
Schartmüller D, Schwarzenbacher L, Schriefl S, Röggla V, Steiner I, Abela-Formanek C, Leydolt C, and Menapace R
- Subjects
- Humans, Lens Implantation, Intraocular, Prospective Studies, Prosthesis Design, Refraction, Ocular, Reproducibility of Results, Rotation, Visual Acuity, Astigmatism surgery, Lenses, Intraocular, Phacoemulsification
- Abstract
Purpose: To assess the reliability and reproducibility of a new semiautomated evaluation method, "Rotix," for intraocular lens (IOL) rotation and to define a standardized evaluation method for future toric IOL studies., Design: Reliability and reproducibility study., Methods: Setting: Department of Ophthalmology, Medical University of Vienna., Patient Population: A dataset of 25 patients with 2 consecutive follow-up visits was created to test the intra- and interrater reliability. A data test set of 10 patients including 30 pictures taken 5 minutes apart was created to test the short-term reproducibility., Intervention: Evaluation of IOL rotational stability using nontoric implants in 25 × 2 consecutive follow-up visits. Two experienced graders performed axis evaluation 3 times in a randomized order. One experienced grader performed axis evaluation for the short-term reproducibility study. Reference landmarks at the end of operation were used to assess the IOL axis., Main Outcome Measures: Intra- and interrater reliability and short-term reproducibility of axis measurements., Results: Mean standard deviation for intrarater reliability was 0.16 degrees. The intraclass correlation coefficients were 0.97 for grader 1 and 0.96 for grader 2. A very high interrater correlation of 0.95 was found. The mean individual difference between grader 1 and grader 2 was 0.061 ± 0.28 degrees. Short-term reproducibility showed a mean standard deviation of 0.22 ± 0.14 degrees., Conclusion: The novel semiautomated evaluation method showed an accurate inter- and intrarater reliability. Short-term reproducibility was below 0.25 degrees. The method of using nonmovable reference landmarks showed reliable results and should be used as a standard in future toric IOL studies., (Copyright © 2021 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
41. Comparison of Axis Determination With Different Toric Intraocular Lens Power Calculation Methods.
- Author
-
Röggla V, Schartmüller D, Schwarzenbacher L, Chbib RA, Leydolt C, and Menapace R
- Subjects
- Cornea, Humans, Lens Implantation, Intraocular, Refraction, Ocular, Retrospective Studies, Astigmatism surgery, Lenses, Intraocular, Phacoemulsification
- Abstract
Purpose: To compare the axis position of the measured total corneal astigmatism (TCA) with the axis of the anterior keratometry and the calculated axis position of different toric intraocular lens (IOL) calculators., Methods: A total of 163 astigmatic eyes of 163 patients were retrospectively analyzed. The axis of the actual TCA, measured with anterior segment optical coherence tomography, was compared to the anterior keratometric value (Group I) and three different methods of TCA calculation for toric IOL power determination: Abulafia-Koch regression formula (Group II), Barrett Toric Calculator V2.0 (Group III), and Barrett Toric Calculator V2.0 including measured posterior keratometric value (Group IV). Eyes were assigned to three subgroups: with-the-rule, against-the-rule, and oblique astigmatism., Results: The mean deviation calculated from measured TCA was +0.56° (Group I), -0.32° (Group II), -0.37° (Group III), and -1.00° (Group IV). For with-the-rule astigmatism, the TCA axis agreed most with Group I (6.5% outliers > 5° deviation). For against-the-rule astigmatism, Group IV and Group II were closest to the measured TCA axis (1.5% and 3% outliers with > 5° deviation)., Conclusions: The means of the calculated axis were similar to the measured TCA, but the proportion of outliers with an axis deviation of greater than 5° showed remarkable differences. Isolated anterior keratometric value measurements showed the fewest outliers in with-the-rule astigmatism. In against-the-rule astigmatism, Abulafia-Koch calculation should be used for axis determination. [ J Refract Surg . 2021;37(9):642-647.] .
- Published
- 2021
- Full Text
- View/download PDF
42. Calculation of ocular magnification in phakic and pseudophakic eyes based on anterior segment OCT data.
- Author
-
Langenbucher A, Szentmáry N, Leydolt C, Cayless A, Schwarzenbacher L, Zsolt Nagy Z, and Menapace R
- Subjects
- Biometry, Humans, Refraction, Ocular, Tomography, Optical Coherence, Lens, Crystalline, Lenses, Intraocular
- Abstract
Purpose: The purpose of this study is to develop a straightforward mathematical concept for determination of object to image magnification in both phakic and pseudophakic eyes, based on biometric measures, refractometry and data from an anterior segment optical coherence tomography (OCT)., Methods: We have developed a strategy for calculating ocular magnification based on axial length measurement, phakic anterior chamber and lens thickness, keratometry and crystalline lens front and back surface curvatures for the phakic eye, and axial length measurement, anterior chamber and lens thickness, keratometry and intraocular lens power, refractive index and shape factor for the pseudophakic eye. Comparing the magnification of both eyes of one individual yields aniseikonia, while comparing the preoperative and postoperative situation of one eye provides the gain or loss in ocular magnification. The applicability of this strategy is shown using a clinical example and a small case series in 78 eyes of 39 patients before and after cataract surgery., Results: For the phakic eye, the refractive index of the crystalline lens was adjusted to balance the optical system. The pseudophakic eye is fully determined and we proposed three strategies for considering a potential mismatch of the data: (A) with spherical equivalent refraction, (B) with intraocular lens power and (C) with the shape factor of the lens. Magnification in the phakic eye was -0.00319 ± 0.00014 and with (A) was -0.00327 ± 0.00013, with (B) was -0.00323 ± 0.00014 and with (C) was -0.00326 ± 0.00013. With A/B/C, the magnification of the pseudophakic eye was on average 2.52 ± 2.83%/1.31 ± 2.84%/2.14 ± 2.80% larger compared with the phakic eye. Magnification changes were within a range of ±10%., Conclusions: On average, ocular magnification does not change greatly after cataract surgery with implantation of an artificial lens, but in some cases, the change could be up to ±10%. If the changes are not consistent between the left and right eyes, then this could lead to post-cataract aniseikonia., (© 2021 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.)
- Published
- 2021
- Full Text
- View/download PDF
43. Influence of lens opacities and cataract severity on quantitative fundus autofluorescence as a secondary outcome of a randomized clinical trial.
- Author
-
Reiter GS, Schwarzenbacher L, Schartmüller D, Röggla V, Leydolt C, Menapace R, Schmidt-Erfurth U, and Sacu S
- Subjects
- Aged, Aged, 80 and over, Female, Fluorescence, Humans, Male, Middle Aged, Phacoemulsification, Tomography, Optical Coherence, Cataract pathology, Cataract Extraction, Lens, Crystalline pathology, Optical Imaging
- Abstract
The aim of this study is to investigate the impact of age-related lens opacities and advanced cataract, quantified by LOCS III grading, on quantitative autofluorescence (qAF) measurements in patients before and after cataract surgery. Images from a randomized controlled trial evaluating the impact of femtosecond-laser assisted cataract surgery (FLACS) on retinal thickness were analyzed post-hoc. One-hundred and twenty eyes from 60 consecutive patients with age-related cataract were included and assessed with qAF and optical coherence tomography (OCT) before, 1, 3 and 6 weeks after cataract surgery (randomized 1:1 to FLACS or phacoemulsification). LOCS III grading was performed before surgery. Pre- to post-surgical qAF values, as well as the impact of LOCS III gradings, surgery technique, gender, axial length and age on post-surgery qAF values was investigated using generalized linear mixed models. For this analysis, 106 eyes from 53 patients were usable. No difference in qAF was found between FLACS and phacoemulsification (p > 0.05) and results were pooled for the total cohort. Mean pre-surgical qAF was 89.45 ± 44.9 qAF units, with a significant mean increase of 178.4-191.6% after surgery (p < 0.001). No significant difference was found between the three follow-up visits after surgery (p > 0.05). Higher LOCS III cortical opacity quantifications were associated with a significantly greater increase in qAF after surgery (estimate: 98.56, p = 0.006) and nuclear opacities showed a trend toward an increased change (estimate: 48.8, p = 0.095). Considerable interactions were identified between baseline qAF and cortical opacities, nuclear opacities and posterior subcapsular opacities, as well as nuclear opacities and cortical opacities (p = 0.012, p = 0.064 and p = 0.069, respectively). Quantitative autofluorescence signals are significantly reconstituted after cataract surgery and LOCS III gradings are well associated with post-surgical qAF values. Careful consideration of age-related lens opacities is vital for the correct interpretation of qAF, especially in retinal diseases affecting the elderly.ClinicalTrials.gov Identifier: NCT03465124.
- Published
- 2021
- Full Text
- View/download PDF
44. One-Year Results of Arcuate Keratotomy in Patients With Low to Moderate Corneal Astigmatism Using a Low-Pulse-Energy Femtosecond Laser.
- Author
-
Schwarzenbacher L, Schartmüller D, Röggla V, Meyer E, Leydolt C, and Menapace R
- Subjects
- Aged, Aged, 80 and over, Astigmatism physiopathology, Cataract Extraction, Corneal Topography, Female, Fourier Analysis, Humans, Laser Therapy methods, Lens Implantation, Intraocular, Male, Middle Aged, Prospective Studies, Pseudophakia physiopathology, Refraction, Ocular physiology, Slit Lamp Microscopy, Tomography, Optical Coherence, Tonometry, Ocular, Visual Acuity physiology, Astigmatism surgery, Cornea surgery, Corneal Surgery, Laser methods
- Abstract
Purpose: To investigate corneal astigmatism (CA) reduction and corneal optical quality after surface-penetrating femtosecond laser arcuate keratotomies (Femto AK) considering anterior (CA
ant ) and posterior corneal curvature (CApost ), total corneal refractive power astigmatism (CAtot ), and corneal higher-order aberrations (HOAs) through 1 year., Design: Prospective interventional case series., Methods: Setting: Department of Ophthalmology, Medical University of Vienna. PatientPopulation: Forty-three eyes of 43 patients with age-related cataract and CAtot between 1 and 3 diopters (D)., Intervention: Paired keratotomies were created with a low-energy femtosecond laser (LDV Z8; Ziemer Ophthalmic Systems, Port, Switzerland) and combined with an astigmatic neutral manual posterior-limbal cataract incision. CA and HOAs measurements were obtained preoperatively and after 1 month, 3 months, and 1 year. MainOutcomeMeasure: Change of CA and HOAs after low-energy Femto AK through 1 year., Results: Mean preoperative CAant and CAtot (1.62 ± 0.49 D and 1.58 ± 0.44 D) were significantly reduced, to 0.66 ± 0.38 and 0.50 ± 0.30 D (P < .001) 1 year after surgery, respectively. CApost showed no significant change, from 0.31 ± 0.19 D preoperatively to 0.31 ± 0.13 D (P = .732) at the 1-year follow-up period. Astigmatism as calculated by vector astigmatism analysis stayed stable at 1 month, 3 months, and 1 year. Corneal wavefront HOAs significantly improved at 1 month, 3 months, and 1 year., Conclusions: Paired surface-penetrating keratotomies created by a low-energy femtosecond laser showed efficient and stable CA reduction within 1 year after surgery. The optical quality of the cornea was preserved with lower HOAs than preoperatively., (Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.)- Published
- 2021
- Full Text
- View/download PDF
45. Reply to Comment on: Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial.
- Author
-
Leydolt C and Menapace R
- Subjects
- Humans, Lens Implantation, Intraocular, Capsule Opacification etiology, Capsule Opacification surgery, Lenses, Intraocular
- Published
- 2021
- Full Text
- View/download PDF
46. Rotational Stability of a New Hydrophobic Acrylic IOL With Modified C-loop Haptics.
- Author
-
Schartmüller D, Röggla V, Schwarzenbacher L, Leydolt C, and Menapace R
- Subjects
- Humans, Hydrophobic and Hydrophilic Interactions, Lens Implantation, Intraocular, Postoperative Period, Prosthesis Design, Rotation, Lenses, Intraocular, Phacoemulsification
- Abstract
Purpose: To assess rotational stability, axial stability, decentration, and tilt of the Rayner RAO800C single-piece hydrophobic acrylic intraocular lens (IOL) (Rayner Intraocular Lenses Ltd) from end of surgery to 4 to 7 months postoperatively., Methods: Surgeries were performed at the Department of Ophthalmology at the Medical University of Vienna. A total of 130 eyes of 68 patients received an aspheric hydrophobic Rayner RAO0800C IOL. IOLs were randomly implanted to the 0 ± 10, 45 ± 10, 90 ± 10, or 135 ± 10 degree axis. Baseline measurement was performed with the patient still supine on the operating table. Axis alignment after 1 hour, 1 week, 1 month, and 4 months was evaluated by retroillumination pictures. Postoperative IOL decentration, tilt, and aqueous depth at 4 months were assessed using an anterior segment swept-source optical coherence tomography., Results: Absolute median IOL rotation from end of surgery to 4 months was 2.4 degrees (range: 0.0 to 85.0 degrees). Median IOL rotation from end of surgery to 1 hour, 1 hour to 1 week, 1 week to 1 month, and 1 month to 4 months was 1.6 (range: 0.0 to 86.2), 1.1 (range: 0.0 to 28.8), 0.6 (range: 0.0 to 5.2), and 0.7 (range: 0.0 to 2.6) degrees. Respective proportions of IOLs rotating more than 5, 10, and 20 degrees from end of surgery to 4 months were 23.9%, 11.0%, and 6.4%. Horizontal and vertical decentration at 4 months was -0.09 ± 0.14 and 0.09 ± 0.14 mm, respectively. Horizontal and vertical tilt at 4 months was -4.78 ± 1.36 and -1.58 ± 1.10 degrees, respectively. A posterior axial shift of 0.052 ± 0.055 mm was observed from 1 week to 4 months., Conclusions: Although median IOL rotation appeared to be low, a significant proportion of IOLs rotated postoperatively. Decentration and tilt values were generally low. A minimal posterior optic shift was observed after 1 week. [J Refract Surg. 2021;37(2):112-118.]., (Copyright 2021, SLACK Incorporated.)
- Published
- 2021
- Full Text
- View/download PDF
47. Influence of Artificial Tears on Keratometric Measurements in Cataract Patients.
- Author
-
Röggla V, Leydolt C, Schartmüller D, Schwarzenbacher L, Meyer E, Abela-Formanek C, and Menapace R
- Subjects
- Administration, Ophthalmic, Aged, Aged, 80 and over, Astigmatism physiopathology, Biometry instrumentation, Cross-Over Studies, Dry Eye Syndromes physiopathology, Female, Humans, Lubricant Eye Drops chemistry, Male, Middle Aged, Ophthalmic Solutions, Phacoemulsification, Prospective Studies, Reproducibility of Results, Viscosity, Cataract complications, Cornea pathology, Diagnostic Techniques, Ophthalmological instrumentation, Dry Eye Syndromes drug therapy, Lubricant Eye Drops administration & dosage
- Abstract
Purpose: To assess the influence of artificial tears of different viscosity on K-readings prior to cataract surgery., Design: Prospective randomized crossover, before-and-after clinical study., Methods: Setting: Department of Ophthalmology, Medical University of Vienna., Patient Population: A total of 123 eyes of 80 patients prior to cataract surgery were assigned to 2 groups based on normal and dry eyes., Intervention: Two native baseline keratometries were followed by instillation of either high- or low-viscosity eye drops. Keratometry was repeated 30 seconds, 2 minutes, and 5 minutes after instillation., Main Outcome Measures: Influence of eye drops of different viscosity in normal and dry eyes on short time K-readings., Results: Repeatability between native baseline measurements was high (standard deviation = 0.02 mm in normal and in dry eyes). In normal and dry eyes, a statistically significant increase in measurement variability after instillation of both low-viscosity and high-viscosity eye drops was observed (P < .01). Measurement variability was most pronounced between baseline measurement and 30 seconds and diminished over time. Variability of K-readings appeared higher in dry eyes compared with normal eyes. Astigmatism changed more than 0.5 diopters in 13.2% of normal eyes and 34.4% in dry eyes using eye drops of high viscosity., Conclusion: Tear film-stabilizing eye drops prior to keratometry measurements influenced K-readings significantly, especially in dry eyes. A time period of more than 5 minutes should be allowed to pass after instillation of eye drops. The higher the viscosity of the eye drops, the stronger the influence and the longer its persistence., (Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
48. Comparison of Long-Term Rotational Stability of Three Commonly Implanted Intraocular Lenses.
- Author
-
Schartmüller D, Schwarzenbacher L, Meyer EL, Schriefl S, Leydolt C, and Menapace R
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Phacoemulsification, Postoperative Period, Prospective Studies, Prosthesis Design, Pseudophakia physiopathology, Acrylic Resins, Lenses, Intraocular, Pseudophakia surgery, Refraction, Ocular physiology, Visual Acuity
- Abstract
Purpose: To compare rotational stability and its influencing factors in 3 different widely used hydrophobic acrylic intraocular lenses (IOLs) from the end of surgery (EoS) to 4-7 months (6 months) in over 380 eyes., Design: Prospective interventional comparative clinical study., Methods: Setting: Department of Ophthalmology, Medical University of Vienna., Patient Population: A total of 381 eyes of 199 patients with age-related cataract received an IOL Acrysof SN60WF, Tecnis ZCB00, or Envista MX60 in a consecutive order., Intervention: Implantation of an Acrysof, Tecnis, or Envista IOL randomized to the 0 ± 10, 45 ± 10, 90 ± 10, or 135 ± 10° axis in 1 or both eyes. Baseline measurement was performed with patients supine still on the operating table. Postoperative follow-ups were conducted after 1 hour, 1 week, 1 month, and 6 months., Main Outcome Measures: Difference of absolute rotation from the EoS to 6 months., Results: Absolute rotations from the EoS to 6 months were 1.65 ± 2.1, 2.65 ± 4.1, and 3.18 ± 5.8° for the Acrysof, Tecnis, and Envista group, respectively. Rotational stability was statistically significantly superior in the Acrysof compared with the Envista group (P = .014), but not compared with the Tecnis group (P = .10). No significant difference was found between the Tecnis and Envista groups (P = .761). Maximum values of 15.8, 38.6, and 44.9° were observed for the Acrysof, Tecnis, and Envista group, respectively., Conclusion: The Acrysof IOL showed the least amount of absolute rotation compared with the Tecnis and Envista IOLs. Outliers possibly requiring secondary intervention were observed in all groups. The amount of rotation was greatest during the first postoperative hour., (Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
49. Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial.
- Author
-
Leydolt C, Schartmüller D, Schwarzenbacher L, Röggla V, Schriefl S, and Menapace R
- Subjects
- Aged, Austria epidemiology, Capsule Opacification diagnosis, Capsule Opacification epidemiology, Double-Blind Method, Female, Follow-Up Studies, Humans, Incidence, Laser Therapy adverse effects, Lens Capsule, Crystalline surgery, Male, Postoperative Complications diagnosis, Postoperative Complications etiology, Prospective Studies, Prosthesis Design, Prosthesis Failure, Time Factors, Acrylic Resins adverse effects, Capsule Opacification etiology, Lens Capsule, Crystalline pathology, Lenses, Intraocular adverse effects, Phacoemulsification adverse effects, Postoperative Complications epidemiology
- Abstract
Purpose: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium-yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years., Design: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison., Methods: Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria., Patient Population: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WF IOL in the other eye., Observation Procedures: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA)., Main Outcome Measure: PCO score (scale, 0-10)., Results: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 ± 0.8 compared to the PCO score of 1.4 ± 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23)., Conclusion: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development., (Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
50. Intraindividual comparison of cytokine and prostaglandin levels with and without low-energy, high-frequency femtosecond laser cataract pretreatment after single-dose topical NSAID application.
- Author
-
Schwarzenbacher L, Schartmüller D, Leydolt C, and Menapace R
- Subjects
- Anti-Inflammatory Agents, Non-Steroidal, Cytokines, Humans, Lasers, Prospective Studies, Prostaglandins, Cataract, Cataract Extraction, Laser Therapy, Phacoemulsification
- Abstract
Purpose: To investigate interleukin (IL)-1β, IL-6, and total prostaglandin (PG) levels in the anterior chamber in patients undergoing low pulse energy femtosecond laser-assisted cataract surgery., Methods: Forty patients undergoing immediate sequential cataract surgery received randomized low-energy femtosecond laser pretreatment in 1 eye and conventional phacoemulsification in the other. Aqueous humor was collected precisely 5 minutes after femtosecond laser pretreatment and before conventional phacoemulsification from all 80 eyes. IL-1β, IL-6, and total PG (including PGE1, PGE2; PGF1a, PGF2a) levels were analyzed using enzyme-linked immunoassay kits. One drop of ketorolac 0.5% was administered 30 minutes preoperatively., Results: Mean concentrations of IL-1β, IL-6, and total PG were 0.87, 0.67, and 32.19 pg/mL in the femto group compared with 0.10 (P = .36), 0.78 (P = .79), and 19.66 pg/mL (P < .05) in the nonfemto group. Levels of IL-1β and IL-6 were not statistically significantly different when compared between groups. There was a small but statistically significant increase of PG levels in the femto group. There were no statistically significant correlations between levels of 1β, IL-6, or total PG and suction time or lens density (P > .05)., Conclusions: Low pulse energy femtosecond laser pretreatment did not trigger any additional IL and only a small but statistically significant increase of PG release in the anterior chamber after a single-dose of topical nonsteroidal antiinflammatory drug administered 30 minutes before the start of cataract surgery. The findings indicated that the minor inflammatory reaction was due to the lower pulse energy concept applied by the femtosecond laser.
- Published
- 2020
- Full Text
- View/download PDF