7 results on '"Lauer AW"'
Search Results
2. TheraBracelet Stimulation During Task-Practice Therapy to Improve Upper Extremity Function After Stroke: A Pilot Randomized Controlled Study.
- Author
-
Seo NJ, Woodbury ML, Bonilha L, Ramakrishnan V, Kautz SA, Downey RJ, Dellenbach BHS, Lauer AW, Roark CM, Landers LE, Phillips SK, and Vatinno AA
- Subjects
- Arm physiopathology, Female, Hand physiopathology, Humans, Male, Middle Aged, Pilot Projects, Recovery of Function, Electric Stimulation Therapy, Stroke Rehabilitation methods, Task Performance and Analysis, Upper Extremity physiopathology
- Abstract
Background: Peripheral sensory stimulation has been used in conjunction with upper extremity movement therapy to increase therapy-induced motor gains in patients with stroke. The limitation is that existing sensory stimulation methods typically interfere with natural hand tasks and thus are administered prior to therapy, requiring patients' time commitment. To address this limitation, we developed TheraBracelet. This novel stimulation method provides subthreshold (ie, imperceptible) vibratory stimulation to the wrist and can be used during hand tasks/therapy without interfering with natural hand tasks., Objective: The objective was to determine the feasibility of using TheraBracelet during therapy to augment motor recovery after stroke., Design: The design was a triple-blinded pilot randomized controlled trial., Methods: Twelve chronic stroke survivors were assigned to the treatment or control group. All participants completed 2-hour task practice therapy sessions thrice weekly for 2 weeks. Both groups wore a small vibrator on the paretic wrist, which was turned on to provide TheraBracelet stimulation for the treatment group and turned off for the control group to provide sham stimulation. Outcome measures (Box and Block Test [BBT] and Wolf Motor Function Test [WMFT]) were obtained at baseline, 6 days after therapy, and at follow-up 19 days after therapy., Results: The intervention was feasible with no adverse events. The treatment group significantly improved their BBT scores after therapy and at follow-up compared with baseline, whereas the control group did not. For WMFT, the group × time interaction was short of achieving significance. Large effect sizes were obtained (BBT d = 1.43, WMFT d = 0.87). No indication of desensitization to TheraBracelet stimulation was observed., Limitations: The limitation was a small sample size., Conclusions: TheraBracelet could be a promising therapy adjuvant for upper extremity recovery after stroke., (© 2019 American Physical Therapy Association.)
- Published
- 2019
- Full Text
- View/download PDF
3. Use of imperceptible wrist vibration to modulate sensorimotor cortical activity.
- Author
-
Seo NJ, Lakshminarayanan K, Lauer AW, Ramakrishnan V, Schmit BD, Hanlon CA, George MS, Bonilha L, Downey RJ, DeVries W, and Nagy T
- Subjects
- Adult, Electromyography, Female, Humans, Male, Physical Stimulation, Vibration, Wrist physiology, Young Adult, Brain Waves physiology, Cortical Synchronization physiology, Electroencephalography methods, Muscle, Skeletal physiology, Sensorimotor Cortex physiology, Touch Perception physiology, Transcranial Magnetic Stimulation methods
- Abstract
Peripheral sensory stimulation has been used as a method to stimulate the sensorimotor cortex, with applications in neurorehabilitation. To improve delivery modality and usability, a new stimulation method has been developed in which imperceptible random-frequency vibration is applied to the wrist concurrently during hand activity. The objective of this study was to investigate effects of this new sensory stimulation on the sensorimotor cortex. Healthy adults were studied. In a transcranial magnetic stimulation (TMS) study, resting motor threshold, short-interval intracortical inhibition, and intracortical facilitation for the abductor pollicis brevis muscle were compared between vibration on vs. off, while subjects were at rest. In an electroencephalogram (EEG) study, alpha and beta power during rest and event-related desynchronization (ERD) for hand grip were compared between vibration on vs. off. Results showed that vibration decreased EEG power and decreased TMS short-interval intracortical inhibition (i.e., disinhibition) compared with no vibration at rest. Grip-related ERD was also greater during vibration, compared to no vibration. In conclusion, subthreshold random-frequency wrist vibration affected the release of intracortical inhibition and both resting and grip-related sensorimotor cortical activity. Such effects may have implications in rehabilitation.
- Published
- 2019
- Full Text
- View/download PDF
4. Evaluation of the effect scan pattern has on the trueness and precision of six intraoral digital impression systems.
- Author
-
Mennito AS, Evans ZP, Lauer AW, Patel RB, Ludlow ME, and Renne WG
- Subjects
- Computer-Aided Design, Dental Arch, Imaging, Three-Dimensional, Dental Impression Technique, Models, Dental
- Abstract
Objective: Clinicians have been slow to adopt digital impression technologies due possibly to perceived technique sensitivities involved in data acquisition. This research has two aims: determine whether scan pattern and sequence affects the accuracy of the three-dimensional (3D) model created from this digital impression and to compare the 5 imaging systems with regards to their scanning accuracy for sextant impressions., Materials and Methods: Six digital intraoral impression systems were used to scan a typodont sextant with optical properties similar to natural teeth. The impressions were taken using five different scan patterns and the resulting digital models were overlayed on a master digital model to determine the accuracy of each scanner performing each scan pattern. Furthermore, regardless of scan pattern, each digital impression system was evaluated for accuracy to the other systems in this same manner., Results: No differences of significance were noted in the accuracy of 3D models created using six distinct scan patterns with one exception involving the CEREC Omnicam. Planmeca Planscan was determined to be the truest scanner while 3Shape Trios was determined to be the most precise for sextant impression making., Conclusions: Scan pattern does not significantly affect the accuracy of the resulting digital model for sextant scanning., Clinical Significance: Companies who make digital impression systems often recommend a scan pattern specific for their system. However, every clinical scanning scenario is different and may require a different approach. Knowing how important scan pattern is with regards to accuracy would be helpful for guiding a growing number of practitioners who are utilizing this technology., (© 2018 Wiley Periodicals, Inc.)
- Published
- 2018
- Full Text
- View/download PDF
5. Delayed grip relaxation and altered modulation of intracortical inhibition with aging.
- Author
-
Motawar B, Stinear JW, Lauer AW, Ramakrishnan V, and Seo NJ
- Subjects
- Adolescent, Adult, Aged, Electromyography methods, Female, H-Reflex physiology, Humans, Male, Motor Cortex physiology, Time Factors, Young Adult, Aging physiology, Evoked Potentials, Motor physiology, Hand Strength physiology, Muscle Relaxation physiology
- Abstract
Grip relaxation is a voluntary action that requires an increase in short-interval intracortical inhibition (SICI) in healthy young adults, rather than a simple termination of excitatory drive. The way aging affects this voluntary inhibitory action and timing of grip relaxation is currently unknown. The objective of this study was to examine aging-related delays in grip relaxation and SICI modulation for the flexor digitorum superficialis muscle during grip relaxation. The main finding was that young adults increased SICI to relax their grips, whereas older adults did not increase SICI with a prolonged grip relaxation time (p < 0.05 for both SICI modulation and grip relaxation time). A secondary experiment showed that both young and older adults did not change H reflex excitability during grip relaxation. Our data suggest that grip relaxation is mediated by increased cortical inhibitory output in young adults, and aging-related impairment in increasing cortical inhibitory output may hamper timely cessation of muscle activity. Our data also suggest a lesser role of the spinal circuits in grip muscle relaxation. This knowledge may contribute to understanding of aging-related movement deterioration and development of interventions for improving modulation of SICI to improve muscle relaxation and movement coordination.
- Published
- 2016
- Full Text
- View/download PDF
6. Effect of imperceptible vibratory noise applied to wrist skin on fingertip touch evoked potentials - an EEG study.
- Author
-
Seo NJ, Lakshminarayanan K, Bonilha L, Lauer AW, and Schmit BD
- Abstract
Random vibration applied to skin can change the sense of touch. Specifically, low amplitude white-noise vibration can improve fingertip touch perception. In fact, fingertip touch sensation can improve even when imperceptible random vibration is applied to other remote upper extremity areas such as wrist, dorsum of the hand, or forearm. As such, vibration can be used to manipulate sensory feedback and improve dexterity, particularly during neurological rehabilitation. Nonetheless, the neurological bases for remote vibration enhanced sensory feedback are yet poorly understood. This study examined how imperceptible random vibration applied to the wrist changes cortical activity for fingertip sensation. We measured somatosensory evoked potentials to assess peak-to-peak response to light touch of the index fingertip with applied wrist vibration versus without. We observed increased peak-to-peak somatosensory evoked potentials with wrist vibration, especially with increased amplitude of the later component for the somatosensory, motor, and premotor cortex with wrist vibration. These findings corroborate an enhanced cortical-level sensory response motivated by vibration. It is possible that the cortical modulation observed here is the result of the establishment of transient networks for improved perception., (© 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.)
- Published
- 2015
- Full Text
- View/download PDF
7. Application of vibration to wrist and hand skin affects fingertip tactile sensation.
- Author
-
Lakshminarayanan K, Lauer AW, Ramakrishnan V, Webster JG, and Seo NJ
- Abstract
A recent study showed that fingertip pads' tactile sensation can improve by applying imperceptible white-noise vibration to the skin at the wrist or dorsum of the hand in stroke patients. This study further examined this behavior by investigating the effect of both imperceptible and perceptible white-noise vibration applied to different locations within the distal upper extremity on the fingertip pads' tactile sensation in healthy adults. In 12 healthy adults, white-noise vibration was applied to one of four locations (dorsum hand by the second knuckle, thenar and hypothenar areas, and volar wrist) at one of four intensities (zero, 60%, 80%, and 120% of the sensory threshold for each vibration location), while the fingertip sensation, the smallest vibratory signal that could be perceived on the thumb and index fingertip pads, was assessed. Vibration intensities significantly affected the fingertip sensation (P < 0.01) in a similar manner for all four vibration locations. Specifically, vibration at 60% of the sensory threshold improved the thumb and index fingertip tactile sensation (P < 0.01), while vibration at 120% of the sensory threshold degraded the thumb and index fingertip tactile sensation (P < 0.01) and the 80% vibration did not significantly change the fingertip sensation (P > 0.01), all compared with the zero vibration condition. This effect with vibration intensity conforms to the stochastic resonance behavior. Nonspecificity to the vibration location suggests the white-noise vibration affects higher level neuronal processing for fingertip sensing. Further studies are needed to elucidate the neural pathways for distal upper extremity vibration to impact fingertip pad tactile sensation., (© 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.)
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.