1. A Comparative Analysis of Two Commonly Used FDA-Approved Immunoassays for Fentanyl Detection.
- Author
-
Lam KHB, Menlyadiev M, Buggs V, Parnprome S, Pesce A, Suhandynata RT, Fitzgerald RL, Song L, and Metushi IG
- Subjects
- Humans, Immunoassay methods, Immunoassay standards, Chromatography, Liquid methods, Analgesics, Opioid urine, Analgesics, Opioid analysis, United States, United States Food and Drug Administration, Sensitivity and Specificity, Fentanyl urine, Fentanyl analysis, Tandem Mass Spectrometry methods, Substance Abuse Detection methods
- Abstract
Background: Given the opioid epidemic, fentanyl screening in urine has become increasingly important. Immunoassays remain the most common screening methodology due to the high throughput and ease of integration into automated chemistry systems. The fentanyl ARK II from Ark Diagnostics is a widely used immunoassay, while a novel fentanyl assay called FEN2 by Lin-Zhi has become available on the Roche platform. Here, we evaluate and compare their performance., Methods: Four hundred and thirty-four urine samples were analyzed for fentanyl across the Lin-Zhi FEN2 and ARK II assays on the Cobas c502 platform. Samples were analyzed immediately upon request for drug of abuse screening or frozen for subsequent analysis. For confirmation testing, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with a limit of detection of 1 ng/mL for fentanyl/norfentanyl was used. Any sample with either fentanyl or norfentanyl above the LC-MS/MS cutoff was deemed positive., Results: The ARK II had 11 false negatives and 7 false positives, while the Lin-Zhi FEN2 had 12 false negatives and 2 false positives. This resulted in ARK II having a sensitivity and specificity of 90.4% and 97.8% respectively, while Lin-Zhi FEN2 had a sensitivity and specificity of 89.5% and 99.4%., Conclusions: Both the ARK II and Lin-Zhi FEN2 immunoassays detected fentanyl well. Overall, the Lin-Zhi assay had slightly better specificity than ARK II, in our data set. While some discrepant results were observed between the 2 immunoassay systems, most occurred near the immunoassay detection cutoffs., (© Association for Diagnostics & Laboratory Medicine 2024. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.)
- Published
- 2024
- Full Text
- View/download PDF