10 results on '"Krainak DM"'
Search Results
2. Quantitative Brain Amyloid PET.
- Author
-
Jagust WJ, Mattay VS, Krainak DM, Wang SJ, Weidner LD, Hofling AA, Koo H, Hsieh P, Kuo PH, Farrar G, and Marzella L
- Subjects
- Humans, Alzheimer Disease diagnostic imaging, Alzheimer Disease metabolism, Positron-Emission Tomography methods, Brain diagnostic imaging, Brain metabolism, Amyloid metabolism
- Abstract
Since the development of amyloid tracers for PET imaging, there has been interest in quantifying amyloid burden in the brains of patients with Alzheimer disease. Quantitative amyloid PET imaging is poised to become a valuable approach in disease staging, theranostics, monitoring, and as an outcome measure for interventional studies. Yet, there are significant challenges and hurdles to overcome before it can be implemented into widespread clinical practice. On November 17, 2022, the U.S. Food and Drug Administration, Society of Nuclear Medicine and Molecular Imaging, and Medical Imaging and Technology Alliance cosponsored a public workshop comprising experts from academia, industry, and government agencies to discuss the role of quantitative brain amyloid PET imaging in staging, prognosis, and longitudinal assessment of Alzheimer disease. The workshop discussed a range of topics, including available radiopharmaceuticals for amyloid imaging; the methodology, metrics, and analytic validity of quantitative amyloid PET imaging; its use in disease staging, prognosis, and monitoring of progression; and challenges facing the field. This report provides a high-level summary of the presentations and the discussion., (© 2024 by the Society of Nuclear Medicine and Molecular Imaging.)
- Published
- 2024
- Full Text
- View/download PDF
3. US regulatory considerations for low field magnetic resonance imaging systems.
- Author
-
Krainak DM, Zeng R, Li N, Woods TO, and Delfino JG
- Subjects
- United States, United States Food and Drug Administration, Artificial Intelligence, Magnetic Resonance Imaging
- Abstract
Although there has been a resurgence of interest in low field magnetic resonance imaging (MRI) systems in recent years, low field MRI is not a new concept. FDA has a long history of evaluating the safety and effectiveness of MRI systems encompassing a wide range of field strengths. Many systems seeking marketing authorization today include new technological features (such as artificial intelligence), but this does not fundamentally change the regulatory paradigm for MR systems. In this review, we discuss some of the US regulatory considerations for low field magnetic resonance imaging (MRI) systems, including applicability of existing laws and regulations and how the U.S. Food and Drug Administration (FDA) evaluates low field MRI systems for market authorization. We also discuss regulatory considerations in the review of low field MRI systems incorporating novel AI technology. We foresee that MRI systems of all field strengths intended for general diagnostic use will continue to be evaluated for marketing clearance by the metric of substantial equivalence set forth in the premarket notification pathway., (© 2023. This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply.)
- Published
- 2023
- Full Text
- View/download PDF
4. US FDA public meeting: identification of concepts and terminology for multicomponent biomarkers.
- Author
-
Agyeman AS, Bandukwala A, Bouri K, Hawes J, Krainak DM, Lababidi S, Mattes WB, Mishina EV, Turfle P, Wang SJ, and Thekkudan T
- Abstract
The US FDA convened a virtual public workshop with the goals of obtaining feedback on the terminology needed for effective communication of multicomponent biomarkers and discussing the diverse use of biomarkers observed across the FDA and identifying common issues. The workshop included keynote and background presentations addressing the stated goals, followed by a series of case studies highlighting FDA-wide and external experience regarding the use of multicomponent biomarkers, which provided context for panel discussions focused on common themes, challenges and preferred terminology. The final panel discussion integrated the main concepts from the keynote, background presentations and case studies, laying a preliminary foundation to build consensus around the use and terminology of multicomponent biomarkers.
- Published
- 2023
- Full Text
- View/download PDF
5. Interrater Reliability of National Institutes of Health Traumatic Brain Injury Imaging Common Data Elements for Brain Magnetic Resonance Imaging in Mild Traumatic Brain Injury.
- Author
-
Rincon SP, Mukherjee P, Levin HS, Temkin NR, Mac Donald CL, Krainak DM, Sun X, Jain S, Taylor SR, Markowitz AJ, Kumar A, Manley GT, and Yuh EL
- Subjects
- Adolescent, Adult, Aged, Artifacts, Biomarkers, Brain Contusion diagnostic imaging, Common Data Elements, Diffuse Axonal Injury diagnostic imaging, Female, Humans, Male, Middle Aged, Observer Variation, Reproducibility of Results, United States, Young Adult, Brain Concussion diagnostic imaging, Brain Injuries, Traumatic diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
The National Institutes of Health/National Institute of Neurological Disorders and Stroke (NIH-NINDS) Traumatic Brain Injury (TBI) Imaging Common Data Elements (CDEs) are standardized definitions for pathological intracranial lesions based on their appearance on neuroimaging studies. The NIH-NINDS TBI Imaging CDEs were designed to be as consistent as possible with the U.S. Food and Drug Administration (FDA) definition of biomarkers as "an indicator of normal biological processes, pathogenic processes, or biological responses to an exposure or intervention." However, the FDA qualification process for biomarkers requires proof of reliable biomarker test measurements. We determined the interrater reliability of TBI Imaging CDEs on subacute brain magnetic resonance imaging (MRI) performed on 517 mild TBI patients presenting to 11 U.S. level 1 trauma centers. Three U.S. board-certified neuroradiologists independently evaluated brain MRI performed 2 weeks post-injury for the following CDEs: traumatic axonal injury (TAI), diffuse axonal injury (DAI), and brain contusion. We found very high interrater agreement for brain contusion, with prevalence- and bias-adjusted kappa (PABAK) values for pairs of readers from 0.92 [95% confidence interval, 0.88-0.95] to 0.94 [0.90-0.96]. We found intermediate agreement for TAI and DAI, with PABAK values of 0.74-0.78 [0.70-0.82]. The near-perfect agreement for subacute brain contusion is likely attributable to the high conspicuity and distinctive appearance of these lesions on T1-weighted images. Interrater agreement for TAI and DAI was lower, because signal void in small vascular structures, and artifactual foci of signal void, can be difficult to distinguish from the punctate round or linear areas of slight hemorrhage that are a common hallmark of TAI/DAI on MRI.
- Published
- 2021
- Full Text
- View/download PDF
6. MRI-related FDA adverse event reports: A 10-yr review.
- Author
-
Delfino JG, Krainak DM, Flesher SA, and Miller DL
- Subjects
- Humans, United States, United States Food and Drug Administration legislation & jurisprudence, Magnetic Resonance Imaging adverse effects, Research Report, United States Food and Drug Administration statistics & numerical data
- Abstract
Purpose: To provide an overview of the types of adverse events reported to the US Food and Drug Administration (US FDA) for magnetic resonance (MR) systems over a 10-yr period., Methods: Two reviewers independently reviewed adverse events reported to FDA for MR systems from 1 January 2008 to 31 December 2017 and manually categorized events into eight event types. Thermal events were further subcategorized by probable cause. Objects that became projectiles were also categorized., Results: FDA received 1568 adverse event reports for MR systems between 1 January 2008 and 31 December 2017. This analysis included 1548 reports. Thermal events were the most commonly reported serious injury (59% of analyzed reports). Mechanical events - defined as slips, falls, crush injuries, broken bones, and cuts; musculoskeletal injuries from lifting or movement of the device - (11%), projectile events (9%), and acoustic events (6%) were also observed., Conclusions: Adverse events related to MR systems consistent with the known hazards of the MR environment continue to be reported to FDA. Increased awareness of the types of adverse events occurring for MR imaging systems is important for prevention., (Published 2019. This article is a U.S. Government work and is in the public domain in the USA.)
- Published
- 2019
- Full Text
- View/download PDF
7. Thermal Hazard for MR Imaging Systems Includes All Textiles with Metal.
- Author
-
Krainak DM, Delfino JG, and Woods TO
- Subjects
- Magnetic Resonance Imaging, Metals, Hot Temperature, Textiles
- Published
- 2018
- Full Text
- View/download PDF
8. Brain tumor clinical trials imaging: a (well-standardized) picture is worth a thousand words.
- Author
-
Sul J and Krainak DM
- Subjects
- Humans, Brain Neoplasms pathology, Magnetic Resonance Imaging methods, Magnetic Resonance Imaging standards, Neuroimaging methods, Neuroimaging standards
- Published
- 2015
- Full Text
- View/download PDF
9. Effects of body orientation on maximum voluntary arm torques.
- Author
-
Krainak DM, Ellis MD, Bury K, Churchill S, Pavlovics E, Pearson L, Shah M, and Dewald JP
- Subjects
- Adult, Aged, Electromyography methods, Female, Humans, Male, Middle Aged, Photic Stimulation methods, Psychomotor Performance physiology, Range of Motion, Articular physiology, Young Adult, Arm physiology, Movement physiology, Orientation physiology, Stroke physiopathology, Torque
- Abstract
Introduction: Increased reliance on bulbospinal motor systems has been implicated in individuals with chronic stroke during maximum voluntary arm joint torque generation., Methods: Maximum isometric single-joint and multi-joint arm strength was observed in two body orientations (sitting and supine) while maintaining identical head/neck/trunk/extremity joint configurations in order to identify bulbospinal contributions to maximum joint torque generation in 11 individuals with stroke and 10 individuals without stroke., Results: During sitting, shoulder flexion was greater for both groups, whereas shoulder extension and elbow flexion, part of the "flexion synergy," were greater only in individuals with stroke., Conclusions: Body orientation influenced isometric arm strength, notably the constituents of flexion synergy in individuals with stroke, suggesting bulbospinal motor pathway involvement. From a practical perspective, clinical evaluation of single joint strength in the supine position may underestimate strength available during activities of daily living that are performed in an upright orientation., (Copyright © 2011 Wiley Periodicals, Inc.)
- Published
- 2011
- Full Text
- View/download PDF
10. A method to capture six-degrees-of-freedom mechanical measurements of isometric shoulder and elbow torques during event-related fMRI.
- Author
-
Krainak DM, Parrish TB, and Dewald JP
- Subjects
- Adult, Artifacts, Equipment Design, Equipment Failure Analysis, Humans, Male, Manometry instrumentation, Manometry methods, Muscle, Skeletal physiology, Myography methods, Range of Motion, Articular, Reproducibility of Results, Sensitivity and Specificity, Transducers, Brain physiology, Elbow Joint physiology, Evoked Potentials physiology, Isometric Contraction physiology, Magnetic Resonance Imaging methods, Myography instrumentation, Shoulder Joint physiology
- Abstract
Functional magnetic resonance imaging (fMRI) experiments investigating cortical activity while controlling task performance are difficult to conduct due to the high magnetic field environment and a lack of compatible measurement tools. We describe a method to measure the generation of isometric shoulder and elbow torques with a six-degrees-of-freedom (DOF) load cell during an event-related fMRI study. Feasibility of this method is demonstrated by finding cortical activity on the motor cortices in a participant during an event-related study of shoulder abduction and elbow flexion. The described methodology permits researchers to control and measure intersubject and intrasubject motor task performance during event-related brain imaging.
- Published
- 2007
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.