1. Quantitative contrast enhanced dual energy CT to predict avascular necrosis: a feasibility study of proximal humerus fractures
- Author
-
Kevin B. Hoover, Alexandria O. Starks, Valentina Robila, and Daniel L. Riddle
- Subjects
Dual energy computed tomography ,Iodine map ,Avascular necrosis ,Ischemia ,Bone ,Fracture ,Medical technology ,R855-855.5 - Abstract
Abstract Background Avascular necrosis is a delayed complication of proximal humerus fractures that increases the likelihood of poor clinical outcomes. CT scans are routinely performed to guide proximal humerus fracture management. We hypothesized iodine concentration on post-contrast dual energy CT scans identifies subjects who develop avascular necrosis and ischemia due to compromised blood flow. Materials and methods 55 patients with proximal humerus fractures enrolled between 2014 and 2017 underwent clinical, radiographic and contrast enhanced dual energy CT assessment. Iodine densities of the humeral head and the glenoid (control) were measured on CT. Subjects managed with open reduction internal fixation or conservatively (non-surgical) were followed for up to two years for radiographic evidence of avascular necrosis. Arthroplasty subjects underwent histopathologic evaluation for ischemia of the resected humeral head. Results 17 of 55 subjects (30.9%) were treated conservatively, 21 (38.2%) underwent open reduction internal fixation and 17 of 55 (30.9%) underwent arthroplasty. Of the 38 subjects treated conservatively or with ORIF, 20 (52.6%) completed 12 months of follow up and 14 (36.8%) 24 months of follow up. At 12 months follow up, two of 20 subjects (10%) and at 24 months 3 of 14 subjects (21.4%) developed avascular necrosis. At 12 months, the mean humerus/glenoid iodine ratio was 1.05 (standard deviation 0.24) in subjects with AVN compared to 0.91 (0.24) in those who did not. At 24 months, subjects with avascular necrosis had a mean humerus/glenoid iodine concentration ratio of 1.06 (0.17) compared to 0.924 (0.21) in those who did not. Of 17 arthroplasty subjects, 2 had severe ischemia and an iodine ratio of 1.08 (0.30); 5 had focal ischemia and a ratio of 1.00 (0.36); and 8 no ischemia and a ratio of 0.83 (0.08). Conclusions Quantifying iodine using dual energy CT in subjects with proximal humerus fractures is technically feasible. Preliminary data suggest higher humeral head iodine concentration may increase risk of avascular necrosis; however, future studies must enroll and follow enough subjects managed with open reduction internal fixation or conservatively for two or more years to provide statistically significant results. Trial Registrations NCT02170545 registered June 23, 2014, ClinicalTrials.gov.
- Published
- 2021
- Full Text
- View/download PDF