1. Performance of microbiological tests for tuberculosis diagnostic according to the type of respiratory specimen: A 10-year retrospective study
- Author
-
Marc-Olivier Boldi, Justin Denis-Lessard, Rina Neziri, René Brouillet, Christophe von-Garnier, Valérie Chavez, Jesica Mazza-Stalder, Katia Jaton, Gilbert Greub, and Onya Opota
- Subjects
tuberculosis ,PCR ,mycobacterial culture ,bronchoalveolar lavage (BAL) ,bronchial aspirate ,sputum ,Microbiology ,QR1-502 - Abstract
BackgroundThe microbial diagnosis of tuberculosis (TB) remains challenging and relies on multiple microbiological tests performed on different clinical specimens. Polymerase chain reactions (PCRs), introduced in the last decades has had a significant impact on the diagnosis of TB. However, questions remain about the use of PCRs in combination with conventional tests for TB, namely microscopy and culture. We aimed to determine the performance of microscopy, culture and PCR for the diagnosis of pulmonary tuberculosis according to the type of clinical specimen in order to improve the diagnostic yield and to avoid unnecessary, time and labor-intensive tests.MethodsWe conducted a retrospective study (2008-2018) on analysis (34’429 specimens, 14’358 patients) performed in our diagnostic laboratory located in the Lausanne University Hospital to compare the performance of microbiological tests on sputum, induced sputum, bronchial aspirate and bronchoalveolar lavage (BAL). We analysed the performance using a classical “per specimen” approach and a “per patient” approach for paired specimens collected from the same patient.ResultsThe overall sensitivities of microscopy, PCR and culture were 0.523 (0.489, 0.557), 0.798 (0.755, 0.836) and 0.988 (0.978, 0.994) and the specificity were 0.994 (0.993, 0.995), 1 (0.999, 1) and 1 (1, 1). Microscopy displayed no significant differences in sensitivity according to the type of sample. The sensitivities of PCR for sputum, induced sputum, bronchial aspirate and BAL were, 0.821 (0.762, 0.871), 0.643 (0.480, 0.784), 0.837 (0.748, 0.904) and 0.759 (0.624, 0.865) respectively and the sensitivity of culture were, 0.993 (0.981, 0.998), 0.980 (0.931, 0.998), 0.965 (0.919, 0.988), and 1 (0.961, 1) respectively. Pairwise comparison of specimens collected from the same patient reported a significantly higher sensitivity of PCR on bronchial aspirate over BAL (p < 0.001) and sputum (p < 0.05) and a significantly higher sensitivity of culture on bronchial aspirate over BAL (p < 0.0001).ConclusionsPCR displayed a higher sensitivity and specificity than microscopy for all respiratory specimens, a rational for a smear-independent PCR-based approach to initiate tuberculosis microbial diagnostic. The diagnosis yield of bronchial aspirate was higher than BAL. Therefore, PCR should be systematically performed also on bronchial aspirates when available.
- Published
- 2023
- Full Text
- View/download PDF