5 results on '"K. Jouini"'
Search Results
2. Effect of gamma irradiation on the color, structure and morphology of nickel-doped polyvinyl alcohol films: Alternative use as dosimeter or irradiation indicator
- Author
-
M. Daoudi, Patrick Blaise, Faouzi Hosni, K. Jouini, Ahmed Hichem Hamzaoui, K. Charradi, Amel Raouafi, and K. Farah
- Subjects
Nuclear and High Energy Physics ,Vinyl alcohol ,Materials science ,Dosimeter ,Scanning electron microscope ,Analytical chemistry ,02 engineering and technology ,Color space ,010402 general chemistry ,021001 nanoscience & nanotechnology ,Microstructure ,01 natural sciences ,Polyvinyl alcohol ,0104 chemical sciences ,chemistry.chemical_compound ,chemistry ,Irradiation ,Fourier transform infrared spectroscopy ,0210 nano-technology ,Instrumentation - Abstract
Nickel-doped poly vinyl alcohol (PVA) films were developed for potential application in industrial sectors like radiation processing. We report in this paper the results of an experimental investigation of 60Co source γ-radiation effect on colorimetric, structural and morphological properties of PVA films doped with 0.5% Ni2+ ions (PVA/Ni2+). The PVA/Ni2+ films were irradiated by different gamma-radiation doses varying from 5 to 100 kGy. Color modification of films were studied using L∗, a∗ and b∗ color space measurements as function of the γ-dose and post-irradiation time. The visual change in all samples was verified by microstructure analysis, Fourier transforms infrared (FTIR) spectroscopy, X-Rays diffraction (XRD) and scanning electron microscopy (SEM). The color space exhibited a linear dose response at a dose ranging from 5 to 50 kGy, and then it reached saturation for higher γ-doses. The calculated color changes (ΔE) show a linear dose response relationship from 9.90 to 115.02 in the dose range from 0 to 50 kGy. It showed also the activation of stable color centers. The variability of the color change did not exceed 3% during 80 h (h) post-irradiation. Furthermore, the microstructure analysis evidenced that the color modification due to the optical activation of nickel-oxide (NiO) color center were obtained by complexing Ni2+ ions in irradiated PVA films. The obtained results inspire the possibility to use PVA films for the control process in industrial radiation facilities in dose range 5–50 kGy.
- Published
- 2018
- Full Text
- View/download PDF
3. Investigation of gamma-ray irradiation induced phase change from NiO to Ni2O3 for enhancing photocatalytic performance
- Author
-
Radhouane Chtourou, W. Dridi, K. Jouini, B. Mustapha, Amel Raouafi, M. Daoudi, and Faouzi Hosni
- Subjects
Materials science ,Photoluminescence ,Nickel oxide ,Non-blocking I/O ,Analytical chemistry ,Gamma ray ,02 engineering and technology ,021001 nanoscience & nanotechnology ,01 natural sciences ,Atomic and Molecular Physics, and Optics ,Electronic, Optical and Magnetic Materials ,010309 optics ,0103 physical sciences ,Photocatalysis ,Crystallite ,Irradiation ,Electrical and Electronic Engineering ,Thin film ,0210 nano-technology - Abstract
An Irradiated nickel oxide (NiO) thin film was deposited onto glass substrates at 723 K by the spray pyrolysis using nickel chloride as precursors. The obtained films were irradiated by gamma-radiation doses varying from 180 Gy to 10 kGy. The structure and optical properties of the samples were examined by X-ray diffraction, UV–vis spectrometer and photoluminescence measurement. Un-irradiated and irradiated NiO thin films have a cubic structure with the same preferred orientation along the plane (111). XRD investigation shows that, the intensity of preferred orientation and crystallite size depend on gamma-radiation dose. For a study of the dose effect, it is very important to optimize the precursor concentration. With a concentration of 5.10−2M precursor NiCl2 and a dose of 10 kGy, we obtain a thin film of Ni2O3. With a 10 kGy dose we obtain a new dominant phase, Ni2O3, which induced an activation of the visible range under the effect of gamma rays. This improved the photocatalytic performance under gamma rays treatment. Moreover, the PL quenching effect shows an improvement of photocatalytic properties.
- Published
- 2019
- Full Text
- View/download PDF
4. On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent
- Author
-
N. de Jong, K. Jouini, Christian Cachard, and Ayache Bouakaz
- Subjects
medicine.medical_specialty ,Acoustics and Ultrasonics ,Heart Ventricles ,media_common.quotation_subject ,Contrast Media ,Blood Pressure ,Microsphere ,Albumins ,Coronary Circulation ,medicine ,Humans ,Contrast (vision) ,Computer Simulation ,Backscatter coefficient ,Lung ,media_common ,business.industry ,Myocardium ,Ultrasound ,Models, Cardiovascular ,Heart ,Acoustics ,Image Enhancement ,Coronary Vessels ,Microspheres ,medicine.anatomical_structure ,Echocardiography ,Ventricle ,Contrast echocardiography ,Injections, Intravenous ,Radiology ,business ,Perfusion ,Biomedical engineering - Abstract
The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the myocardium yet using conventional imaging techniques. The explanation of this phenomenon should be easy by measuring the acoustic characteristics of the contrast agent and then making a comparison of these characteristics with those of the myocardium. In this study we present definitions of standard acoustic parameters of ultrasound contrast agent, the backscatter coefficient B s and the scattering-to-attenuation ratio STAR. Afterwards, considering an intravenous injection of the contrast agent, and taking into account the effects of lung filtering and cardiac pressure, the standard properties of contrast agents are determined in different sites: right ventricle (before lung passage), left ventricle (after lung passage and taking into account the pressure effect) and in the coronary system. Calculations showed that the acoustic properties are considerably influenced by these two effects: lung filtering and cardiac pressure. Comparison of these properties with the tissue properties (myocardium) is then performed. This determines the contribution of the contrast agent to the enhancement of the tissue visualization. The simulations are performed on Albunex microspheres. The results reveal that the difference between scattering of the myocardium and scattering of intravenously injected Albunex is too slight to be visible on an echographic image.
- Published
- 1998
- Full Text
- View/download PDF
5. On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent.
- Author
-
Bouakaz A, de Jong N, Cachard C, and Jouini K
- Subjects
- Acoustics, Computer Simulation, Coronary Circulation, Coronary Vessels diagnostic imaging, Coronary Vessels metabolism, Heart Ventricles diagnostic imaging, Heart Ventricles metabolism, Humans, Image Enhancement, Injections, Intravenous, Microspheres, Models, Cardiovascular, Myocardium, Albumins administration & dosage, Albumins chemistry, Albumins pharmacokinetics, Blood Pressure physiology, Contrast Media administration & dosage, Contrast Media chemistry, Contrast Media pharmacokinetics, Echocardiography, Heart physiology, Lung metabolism
- Abstract
The goal standard of contrast echocardiography is the absolute measure of myocardial perfusion using a contrast agent. Actually, several contrast agents are developed. All these agents show left ventricular opacification after intravenous injection. However, none of these agents shows an acceptable enhancement of the myocardium yet using conventional imaging techniques. The explanation of this phenomenon should be easy by measuring the acoustic characteristics of the contrast agent and then making a comparison of these characteristics with those of the myocardium. In this study we present definitions of standard acoustic parameters of ultrasound contrast agent, the backscatter coefficient Bs and the scattering-to-attenuation ratio STAR. Afterwards, considering an intravenous injection of the contrast agent, and taking into account the effects of lung filtering and cardiac pressure, the standard properties of contrast agents are determined in different sites: right ventricle (before lung passage), left ventricle (after lung passage and taking into account the pressure effect) and in the coronary system. Calculations showed that the acoustic properties are considerably influenced by these two effects: lung filtering and cardiac pressure. Comparison of these properties with the tissue properties (myocardium) is then performed. This determines the contribution of the contrast agent to the enhancement of the tissue visualization. The simulations are performed on Albunex microspheres. The results reveal that the difference between scattering of the myocardium and scattering of intravenously injected Albunex is too slight to be visible on an echographic image.
- Published
- 1998
- Full Text
- View/download PDF