6 results on '"Jamie Concannon"'
Search Results
2. Endovascular versus conventional open surgical repair for thoracoabdominal aortic aneurysms
- Author
-
Sherif Sultan, Jamie Concannon, Dave Veerasingam, Wael Tawfick, Peter McHugh, Fionnuala Jordan, and Niamh Hynes
- Subjects
Aortic Aneurysm, Thoracic ,Endovascular Procedures ,Humans ,Pharmacology (medical) ,Arteries - Abstract
BACKGROUND: Thoracoabdominal aortic aneurysms (TAAAs) are a life‐threatening condition which remain difficult to treat. Endovascular and open surgical repair (OSR) provide treatment options for patients, however, due to the lack of clinical trials comparing these, the optimum treatment option is unknown. OBJECTIVES: To assess the effectiveness and safety of endovascular repair versus conventional OSR for the treatment of TAAAs. SEARCH METHODS: The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, CINAHL and AMED databases and World Health Organization International Clinical Trials Registry Platform and ClinicalTrials.gov trials registers to 26 April 2021. We also searched references of relevant articles retrieved from the electronic search for additional citations. SELECTION CRITERIA: We considered all published and unpublished randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing endovascular repair to OSR for TAAAs for inclusion in the review. The main outcomes of interest were prevention of aneurysm rupture (participants without aneurysm rupture up to 5 years from intervention), aneurysm‐related mortality (30 days and 12 months), all‐cause mortality, spinal cord ischaemia (paraplegia, paraparesis), visceral arterial branch compromise causing mesenteric ischaemia or renal failure, and rate of reintervention. DATA COLLECTION AND ANALYSIS: Two review authors independently screened all titles and abstracts identified from the searches to identify those that met the inclusion criteria. We planned to undertake data collection, risk of bias assessment, and analysis in accordance with Cochrane recommendations. We planned to assess the certainty of the evidence using GRADE. MAIN RESULTS: No RCTs or CCTs met the inclusion criteria for this review. AUTHORS' CONCLUSIONS: Due to the lack of RCTs or CCTs, we were unable to determine the safety and effectiveness of endovascular compared to OSR in patients with TAAAs and are unable to provide any evidence on the optimal surgical intervention for this cohort of patients. High‐quality RCTs or CCTs addressing this objective are necessary, however conducting such studies will be logistically and ethically challenging for this life‐threatening disease.
- Published
- 2023
3. On the Importance of Including Cohesive Zone Models in modelling mixed-mode Aneurysm Rupture
- Author
-
Jamie Concannon, Eamon O Máirtín, Brian FitzGibbon, Niamh Hynes, Sherif Sultan, and Patrick McGarry
- Published
- 2022
- Full Text
- View/download PDF
4. A numerical investigation of the initiation of aortic dissection
- Author
-
Brian FitzGibbon, Behrooz Fereidoonnezhad, Jamie Concannon, Niamh Hynes, Sherif Sultan, Kevin Mattheus Moerman, and Patrick McGarry
- Subjects
engrXiv|Engineering|Biomedical Engineering and Bioengineering ,engrXiv|Engineering ,bepress|Engineering ,bepress|Engineering|Biomedical Engineering and Bioengineering - Abstract
In the first part of this study we develop a realistic subject-specific aorta finite element model derived from a dual-venc MRI scan. We investigate if spontaneous dissection will occur under extreme hypertensive lumen blood pressure loading, or if significant reduction in interface strength must occur in order for dissection to initiate. Importantly, we also demonstrate that dissection initiation is a pure mode II fracture process, rather than a mixed mode or mode I process. In the second part of this study we construct a parameterised idealised aorta model in order to assess the relative contribution for several anatomical and physiological factors to dissection risk. Such parametric analyses provide fundamental insight into the mechanics of stress localisation and delamination in the aorta. Overall, our detailed series of simulations suggest that variations in anatomical features and hypertensive loading will not result in a sufficient elevation of the stress state in the aorta wall to initiate dissection. Our results suggest that initiation of aortic dissection requires a significant reduction in the mode II fracture strength of the aortic wall, suggesting that dissection is preceded by structural and biomechanical remodelling.
- Published
- 2020
5. A dual-VENC 4D Flow MRI Framework for Analysis of Subject-Specific Heterogeneous non-linear Vessel Deformation
- Author
-
Jamie Concannon, Niamh Hynes, Marie McMullan, Evelyn Smyth, Kevin Mattheus Moerman, Peter McHugh, Sherif Sultan, Christof Karmonik, and Patrick McGarry
- Subjects
engrXiv|Engineering|Biomedical Engineering and Bioengineering ,engrXiv|Engineering ,bepress|Engineering ,engrXiv|Engineering|Biomedical Engineering and Bioengineering|Biomechanics and Biotransport ,cardiovascular system ,engrXiv|Engineering|Biomedical Engineering and Bioengineering|Bioimaging and Biomedical Optics ,bepress|Engineering|Biomedical Engineering and Bioengineering|Biomechanics and Biotransport ,bepress|Engineering|Biomedical Engineering and Bioengineering|Bioimaging and Biomedical Optics ,bepress|Engineering|Biomedical Engineering and Bioengineering - Abstract
Advancement of subject-specific in-silico medicine requires new imaging protocols tailored to specific anatomical features, paired with new constitutive model development based on structure/function relationships. In this study we develop a new dual-VENC 4D Flow MRI protocol that provides unprecedented spatial and temporal resolution of in-vivo aortic deformation. All previous dual-VENC 4D Flow MRI studies in the literature focus on an isolated segment of the aorta, which fail to capture the full spectrum of aortic heterogeneity that exists along the vessel length. The imaging protocol developed provides high sensitivity to all blood flow velocities throughout the entire cardiac cycle, overcoming the challenge of accurately measuring the highly unsteady non-uniform flow field in the aorta. Cross sectional area change, volumetric flow rate, and compliance are observed to decrease with distance from the heart, while pulse wave velocity is observed to increase. A non-linear aortic lumen pressure-area relationship is observed throughout the aorta, such that a high vessel compliance occurs during diastole, and a low vessel compliance occurs during systole. This suggests that a single value of compliance may not accurately represent vessel behaviour during a cardiac cycle in-vivo. This high-resolution MRI data provides key information on the spatial variation in non-linear aortic compliance which can significantly advance the state-of-the-art of in-silico diagnostic techniques for the human aorta.
- Published
- 2020
6. Development of an MRI/FEA Framework for Analysis of Subject-Specific Aortic Compliance: Part II- Constitutive Law Development and Prediction of Heterogeneous vessel Composition and Deformation
- Author
-
Jamie Concannon, Niamh Hynes, Sherif Sultan, Peter McHugh, Kevin Mattheus Moerman, and Patrick McGarry
- Subjects
engrXiv|Engineering ,engrXiv|Engineering|Biomedical Engineering and Bioengineering ,bepress|Engineering ,engrXiv|Engineering|Biomedical Engineering and Bioengineering|Biomechanics and Biotransport ,cardiovascular system ,engrXiv|Engineering|Biomedical Engineering and Bioengineering|Bioimaging and Biomedical Optics ,bepress|Engineering|Biomedical Engineering and Bioengineering|Biomechanics and Biotransport ,bepress|Engineering|Biomedical Engineering and Bioengineering|Bioimaging and Biomedical Optics ,bepress|Engineering|Biomedical Engineering and Bioengineering - Abstract
This paper, the second of two parts, presents a novel subject-specific in-silico framework in which we uncover the relationship between the spatially varying constituents of the aorta and the non-linear compliance of the vessel during the cardiac cycle uncovered in Part I. In Part II a novel microstructurally motivated constitutive model is developed, and simulations reveal that internal vessel contractility, due to pre-stretched elastin and actively generated smooth muscle stress, must be incorporated, along with collagen strain stiffening, in order to accurately predict the non-linear pressure-area relationship observed in-vivo. Modelling of elastin and smooth muscle contractility allows for the identification of the reference vessel configuration at zero-lumen pressure, in addition to accurately predicting high- and low-compliance regimes under a physiological range of pressures. This modelling approach is also shown to capture the key features of elastin and SMC knockout experiments. The volume fractions of the constituent components of the aortic material model were computed so that the in-silico pressure-area curves accurately predict the corresponding MRI data at each location. Simulations reveal that collagen and smooth muscle volume fractions increase distally, while elastin volume fraction decreases distally, consistent with reported histological data. Furthermore, the strain at which collagen transitions from low to high stiffness is lower in the abdominal aorta, again supporting the histological finding that collagen waviness is lower in this distally. The analyses presented in this paper provides new insights into the heterogeneous structure-function relationship that underlies aortic biomechanics. This novel subject-specific MRI/FEA methodology provides a foundation for personalised in-silico clinical analysis and tailored aortic device development.
- Published
- 2020
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.