1. Improved quality of samples and laboratory turnaround time using 3.5 mL low vacuum BD Vacutainer® Barricor tubes in the emergency department
- Author
-
S. Badiou, O. Vuillot, A.S. Bargnoux, N. Kuster, S. Lefebvre, M. Sebbane, J.P. Cristol, and A.M. Dupuy
- Subjects
Medicine (General) ,R5-920 ,Chemistry ,QD1-999 - Abstract
Background: Centrifugation is a consuming time step which participates to increase the turnaround time (TAT) in laboratories, likewise hemolysis sample that needs a re-sampling could delay management of patients. Recently, it has been postulated that BD Barricor™ tube could allow to decrease the centrifugation time and prevent hemolysis, two key feature to ensure high-quality results.Aim of the study was to evaluate the impact of replacing 4 mL BD vacutainer heparin lithium tube by low vacuum 3.5 mL BD vacutainer Barricor™ tube in an emergency department (ED) on hemolysis rate and TAT. Methods: Data of hemolysis index (HI) and TAT were compared between the first period of 15 days using 4 mL BD vacutainer heparin lithium tubes with 15 min at 2000xg as centrifugation setting and a second period of 15 days using BD vacutainer Barricor™ tube centrifuged 3 min at 4000xg. Results: A significantly reduced time duration between reception of sample and available results in informatics lab system was observed with the reduction time of centrifugation allowed by use of Barricor™ tube compared to regular heparin lithium tubes (p
- Published
- 2019
- Full Text