1. Endoscopic hand suturing using a modified through-the-scope needle holder for mucosal closure after colorectal endoscopic submucosal dissection: Prospective multicenter study (with video).
- Author
-
Uozumi T, Abe S, Mizuguchi Y, Sekiguchi M, Toyoshima N, Takamaru H, Yamada M, Kobayashi N, Sadachi R, Ito S, Takada K, Kishida Y, Imai K, Hotta K, Ono H, and Saito Y
- Subjects
- Humans, Prospective Studies, Female, Male, Aged, Middle Aged, Aged, 80 and over, Feasibility Studies, Colonoscopy methods, Colonoscopy instrumentation, Endoscopic Mucosal Resection instrumentation, Endoscopic Mucosal Resection methods, Suture Techniques instrumentation, Colorectal Neoplasms surgery, Colorectal Neoplasms pathology, Intestinal Mucosa surgery, Intestinal Mucosa pathology
- Abstract
Objectives: Endoscopic hand suturing (EHS) is a novel technique for closing a mucosal defect after endoscopic submucosal dissection (ESD). We investigated the technical feasibility of colorectal EHS using a modified flexible through-the-scope needle holder., Methods: This was a prospective multicenter study conducted at two referral centers between June 2022 and April 2023. This study included colorectal neoplasms 20-50 mm in size located in the sigmoid colon or rectum. A modified flexible through-the-scope needle holder, with an increased jaw width to facilitate needle grasping, was used for colorectal EHS. The primary end-points were sustained closure rate on second-look endoscopy (SLE) performed on postoperative days 3-4 and suturing time for colorectal EHS. Secondary end-points included complete closure rate and delayed adverse events., Results: We enrolled 20 colorectal neoplasms in 20 patients, including four patients receiving antithrombotic agents. The tumor location was as follows: lower rectum (n = 8), upper rectum (n = 2), rectosigmoid colon (n = 4), and sigmoid colon (n = 6), and the median mucosal defect size was 37 mm (range, 21-65 mm). The complete closure rate was 90% (18/20 [95% confidence interval (CI) 68.3-98.8%]), and the median suturing time was 49 min (range, 23-92 min [95% CI 35-68 min]). Sustained closure rate on SLE was 85% (17/20 [95% CI 62.1-96.8%]). No delayed adverse events were observed., Conclusion: EHS demonstrated a high sustained closure rate. Given the long suturing time and technical difficulty, EHS should be reserved for cases with a high risk of delayed adverse events., (© 2024 Japan Gastroenterological Endoscopy Society.)
- Published
- 2024
- Full Text
- View/download PDF