43 results on '"HIP JOINT CENTRE"'
Search Results
2. Reconstruction of the lower limb bones from digitised anatomical landmarks using statistical shape modelling.
- Author
-
Nolte, Daniel, Ko, Siu-Teing, Bull, Anthony M.J., and Kedgley, Angela E.
- Subjects
- *
LEG , *STATISTICS , *HIP joint , *SOFT tissue injuries , *LABORATORIES , *BIOLOGICAL models , *EXPERIMENTAL design , *RESEARCH , *HUMAN research subjects , *RESEARCH methodology , *HUMAN body , *MAGNETIC resonance imaging , *EVALUATION research , *MEDICAL cooperation , *COMPARATIVE studies , *BODY movement , *RESEARCH funding , *STATISTICAL models , *TIBIA , *FEMUR , *KINEMATICS - Abstract
Background: Bone shapes strongly influence force and moment predictions of kinematic and musculoskeletal models used in motion analysis. The precise determination of joint reference frames is essential for accurate predictions. Since clinical motion analysis typically does not include medical imaging, from which bone shapes may be obtained, scaling methods using reference subjects to create subject-specific bone geometries are widely used.Research Question: This study investigated if lower limb bone shape predictions from skin-based measurements, utilising an underlying statistical shape model (SSM) that corrects for soft tissue artefacts in digitisation, can be used to improve conventional linear scaling methods of bone geometries.Methods: SSMs created from 35 healthy adult femurs and tibiae/fibulae were used to reconstruct bone shapes by minimising the distance between anatomical landmarks on the models and those digitised in the motion laboratory or on medical images. Soft tissue artefacts were quantified from magnetic resonance images and then used to predict distances between landmarks digitised on the skin surface and bone. Reconstruction results were compared to linearly scaled models by measuring root mean squared distances to segmented surfaces, calculating differences of commonly used anatomical measures and the errors in the prediction of the hip joint centre.Results: SSM reconstructed surface predictions from varying landmark sets from skin and bone landmarks were more accurate compared to linear scaling methods (2.60-2.95 mm vs. 3.66-3.87 mm median error; p < 0.05). No significant differences were found between SSM reconstructions from bony landmarks and SSM reconstructions from digitised landmarks obtained in the motion lab and therefore reconstructions using skin landmarks are as accurate as reconstructions from landmarks obtained from medical images.Significance: These results indicate that SSM reconstructions can be used to increase the accuracy in obtaining bone shapes from surface digitised experimental data acquired in motion lab environments. [ABSTRACT FROM AUTHOR]- Published
- 2020
- Full Text
- View/download PDF
3. Hip Joint Centre Localization: Evaluation of Formal Methods and Effects on Joint Kinematics
- Author
-
Żuk, Magdalena, Świątek-Najwer, Ewelina, Pezowicz, Celina, Kacprzyk, Janusz, Series editor, Piętka, Ewa, editor, Kawa, Jacek, editor, and Wieclawek, Wojciech, editor
- Published
- 2014
- Full Text
- View/download PDF
4. The effect on conventional gait model kinematics and kinetics of hip joint centre equations in adult healthy gait.
- Author
-
Leboeuf, F., Reay, J., Jones, R., and Sangeux, M.
- Subjects
- *
KINEMATICS , *HIP joint , *EQUATIONS , *ANATOMICAL planes , *LARGE deviations (Mathematics) , *PRODUCTION standards - Abstract
Abstract The Conventional Gait Model (CGM) needs to benefit from large investigations on localization of the hip joint centre (HJC). Incorrect positions from the native equations were demonstrated (Sangeux et al., 2014; Harrington et al., 2007). More accurate equations were proposed but their impact on kinematics and kinetic CGM outputs was never evaluated. This short communication aims at examining if adoption of new HJC equations would alter standard CGM outputs. Sixteen able bodied participants underwent a full 3-D optoelectronic gait analysis followed by a 3-D ultrasound localization of their hips. Data were processed through the open source python package pyCGM2 replicating kinematic and kinetic processing of the native CGM. Compared with 3D ultrasound location, Hara equations improved the accuracy of sagittal plane kinematics (0.6°) and kinetics (0.02 N m kg −1) for the hip. The worst case participant exhibited Harrington's equations reached a deviation of 3° for the sagittal kinematics. In the coronal plane, Hara and Harrington equations presented similar differences (1°) for the hip whilst Davis equations had the largest deviation for hip abduction (2.7°) and hip abductor moment (0.10 N m kg −1). Both Harrington and Hara equations improved the CGM location of the HJC. Hara equations improved results in the sagittal plane, plus utilise a single anthropometrics measurement, leg length, that may be more robust. However, neither set of equations had significant effect on kinematics. We reported some effects on kinetics, particularly in the coronal plane, which warrant caution in interpreting outputs using different sets of equations. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
5. Statistical shape modelling versus linear scaling: Effects on predictions of hip joint centre location and muscle moment arms in people with hip osteoarthritis.
- Author
-
Bahl, Jasvir S., Zhang, Ju, Killen, Bryce A., Taylor, Mark, Solomon, Lucian B., Arnold, John B., Lloyd, David G., Besier, Thor F., and Thewlis, Dominic
- Subjects
- *
STATISTICAL shape analysis , *HIP joint , *OSTEOARTHRITIS , *COMPUTED tomography , *FLEXOR muscles , *REGRESSION analysis - Abstract
Abstract Marker-based dynamic functional or regression methods are used to compute joint centre locations that can be used to improve linear scaling of the pelvis in musculoskeletal models, although large errors have been reported using these methods. This study aimed to investigate if statistical shape models could improve prediction of the hip joint centre (HJC) location. The inclusion of complete pelvis imaging data from computed tomography (CT) was also explored to determine if free-form deformation techniques could further improve HJC estimates. Mean Euclidean distance errors were calculated between HJC from CT and estimates from shape modelling methods, and functional- and regression-based linear scaling approaches. The HJC of a generic musculoskeletal model was also perturbed to compute the root-mean squared error (RMSE) of the hip muscle moment arms between the reference HJC obtained from CT and the different scaling methods. Shape modelling without medical imaging data significantly reduced HJC location error estimates (11.4 ± 3.3 mm) compared to functional (36.9 ± 17.5 mm, p = <0.001) and regression (31.2 ± 15 mm, p = <0.001) methods. The addition of complete pelvis imaging data to the shape modelling workflow further reduced HJC error estimates compared to no imaging (6.6 ± 3.1 mm, p = 0.002). Average RMSE were greatest for the hip flexor and extensor muscle groups using the functional (16.71 mm and 8.87 mm respectively) and regression methods (16.15 mm and 9.97 mm respectively). The effects on moment-arms were less substantial for the shape modelling methods, ranging from 0.05 to 3.2 mm. Shape modelling methods improved HJC location and muscle moment-arm estimates compared to linear scaling of musculoskeletal models in patients with hip osteoarthritis. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
6. Effects of hip joint centre mislocation on gait kinematics of children with cerebral palsy calculated using patient-specific direct and inverse kinematic models.
- Author
-
Lloyd, David G., Carty, Christopher P., Kainz, Hans, Modenese, Luca, Maine, Sheanna, and Walsh, Henry P.J.
- Subjects
- *
GAIT disorders in children , *HIP joint abnormalities , *KINEMATICS , *PEOPLE with cerebral palsy , *RANGE of motion of joints , *CEREBRAL palsy , *GAIT in humans , *HIP joint , *KNEE , *MAGNETIC resonance imaging , *DIAGNOSIS - Abstract
Joint kinematics can be calculated by Direct Kinematics (DK), which is used in most clinical gait laboratories, or Inverse Kinematics (IK), which is mainly used for musculoskeletal research. In both approaches, joint centre locations are required to compute joint angles. The hip joint centre (HJC) in DK models can be estimated using predictive or functional methods, while in IK models can be obtained by scaling generic models. The aim of the current study was to systematically investigate the impact of HJC location errors on lower limb joint kinematics of a clinical population using DK and IK approaches. Subject-specific kinematic models of eight children with cerebral palsy were built from magnetic resonance images and used as reference models. HJC was then perturbed in 6mm steps within a 60mm cubic grid, and kinematic waveforms were calculated for the reference and perturbed models. HJC perturbations affected only hip and knee joint kinematics in a DK framework, but all joint angles were affected when using IK. In the DK model, joint constraints increased the sensitivity of joint range-of-motion to HJC location errors. Mean joint angle offsets larger than 5° were observed for both approaches (DK and IK), which were larger than previously reported for healthy adults. In the absence of medical images to identify the HJC, predictive or functional methods with small errors in anterior-posterior and medial-lateral directions and scaling procedures minimizing HJC location errors in the anterior-posterior direction should be chosen to minimize the impact on joint kinematics. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF
7. Reliability of functional and predictive methods to estimate the hip joint centre in human motion analysis in healthy adults.
- Author
-
Kainz, Hans, Hajek, Martin, Modenese, Luca, Saxby, David J., Lloyd, David G., and Carty, Christopher P.
- Subjects
- *
HIP joint , *HUMAN mechanics , *GAIT in humans , *ESTIMATION theory , *REGRESSION analysis , *HIP joint physiology , *COMPARATIVE studies , *DIAGNOSTIC imaging , *RANGE of motion of joints , *KINEMATICS , *RESEARCH methodology , *MEDICAL cooperation , *REFERENCE values , *RESEARCH , *WALKING , *EVALUATION research , *BODY movement , *PREDICTIVE tests ,RESEARCH evaluation - Abstract
In human motion analysis predictive or functional methods are used to estimate the location of the hip joint centre (HJC). It has been shown that the Harrington regression equations (HRE) and geometric sphere fit (GSF) method are the most accurate predictive and functional methods, respectively. To date, the comparative reliability of both approaches has not been assessed. The aims of this study were to (1) compare the reliability of the HRE and the GSF methods, (2) analyse the impact of the number of thigh markers used in the GSF method on the reliability, (3) evaluate how alterations to the movements that comprise the functional trials impact HJC estimations using the GSF method, and (4) assess the influence of the initial guess in the GSF method on the HJC estimation. Fourteen healthy adults were tested on two occasions using a three-dimensional motion capturing system. Skin surface marker positions were acquired while participants performed quite stance, perturbed and non-perturbed functional trials, and walking trials. Results showed that the HRE were more reliable in locating the HJC than the GSF method. However, comparison of inter-session hip kinematics during gait did not show any significant difference between the approaches. Different initial guesses in the GSF method did not result in significant differences in the final HJC location. The GSF method was sensitive to the functional trial performance and therefore it is important to standardize the functional trial performance to ensure a repeatable estimate of the HJC when using the GSF method. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF
8. Reconstruction of the lower limb bones from digitised anatomical landmarks using statistical shape modelling
- Author
-
Angela E. Kedgley, Anthony M. J. Bull, Daniel Nolte, Siu-Teing Ko, Engineering & Physical Science Research Council (E, and Wellcome Trust
- Subjects
Male ,endocrine system diseases ,Computer science ,1106 Human Movement and Sports Sciences ,Kinematics ,0302 clinical medicine ,Orthopedics and Sports Medicine ,Computer vision ,Femur ,Rehabilitation ,Statistical shape model ,Middle Aged ,Magnetic Resonance Imaging ,humanities ,Healthy Volunteers ,Biomechanical Phenomena ,Research Design ,Female ,Anatomic Landmarks ,Motion capture ,psychological phenomena and processes ,Reference frame ,0913 Mechanical Engineering ,Adult ,Motion analysis ,endocrine system ,Movement ,Biophysics ,Models, Biological ,Article ,Hip joint centre ,03 medical and health sciences ,Medical imaging ,Humans ,Landmark digitisation ,Joint (geology) ,Aged ,Landmark ,Models, Statistical ,Tibia ,business.industry ,1103 Clinical Sciences ,030229 sport sciences ,Musculoskeletal modelling ,Soft tissue artefact ,Orthopedics ,Moment (physics) ,Artificial intelligence ,business ,030217 neurology & neurosurgery - Abstract
Highlights • Improved scaling of bone shapes from digitised external landmarks for gait analysis. • Scaling of articulated bones. • Quantification of soft tissue artefact in digitisation at landmark locations., Background Bone shapes strongly influence force and moment predictions of kinematic and musculoskeletal models used in motion analysis. The precise determination of joint reference frames is essential for accurate predictions. Since clinical motion analysis typically does not include medical imaging, from which bone shapes may be obtained, scaling methods using reference subjects to create subject-specific bone geometries are widely used. Research question This study investigated if lower limb bone shape predictions from skin-based measurements, utilising an underlying statistical shape model (SSM) that corrects for soft tissue artefacts in digitisation, can be used to improve conventional linear scaling methods of bone geometries. Methods SSMs created from 35 healthy adult femurs and tibiae/fibulae were used to reconstruct bone shapes by minimising the distance between anatomical landmarks on the models and those digitised in the motion laboratory or on medical images. Soft tissue artefacts were quantified from magnetic resonance images and then used to predict distances between landmarks digitised on the skin surface and bone. Reconstruction results were compared to linearly scaled models by measuring root mean squared distances to segmented surfaces, calculating differences of commonly used anatomical measures and the errors in the prediction of the hip joint centre. Results SSM reconstructed surface predictions from varying landmark sets from skin and bone landmarks were more accurate compared to linear scaling methods (2.60–2.95 mm vs. 3.66–3.87 mm median error; p
- Published
- 2020
9. Hip centre regression progression: Same equations, better numbers.
- Author
-
Bakke, Duncan, Zhang, Ju, Hislop-Jambrich, Jacqui, and Besier, Thor
- Subjects
- *
EQUATIONS , *PELVIS , *KINEMATICS , *STATISTICAL models - Abstract
Accurate estimation of the hip joint centre (HJC) location is critical for modelling the kinematics and kinetics of the lower limb. Regression equations are commonly used to predict the HJC from anatomical landmarks on the pelvis, such as those published by Tylkowski et al., Andriacchi et al., Bell et al., and Seidel et al. Using a population of 159 CT-segmented pelvises, we assessed the accuracy of these methods as originally reported, and refined their parameters based on our larger cohort. We found the Tylkowski, Bell, and Seidel methods had mean Euclidean errors of 22.5, 26.4, and 17.9 mm, respectively. With new parameters for each method 'back-calculated' from our pelvic population, each method's error was reduced by an average of 69 %, with mean absolute errors of 7.9, 6.6, and 5.9 mm, respectively. For all methods, error has been reduced to below 1 cm, well below published levels for pelvic landmark estimation methods. These results highlight the need to validate and re-calibrate joint centre prediction methods on large, representative datasets to account for natural morphological variations. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
10. In-vivo quantification of dynamic hip joint center errors and soft tissue artifact.
- Author
-
Fiorentino, Niccolo M., Atkins, Penny R., Kutschke, Michael J., Foreman, K. Bo, and Anderson, Andrew E.
- Subjects
- *
HIP joint physiology , *SOFT tissue injuries , *MEDICAL artifacts , *BIOMECHANICS , *HUMAN kinematics , *DEGREES of freedom , *MATHEMATICAL models , *FLUOROSCOPY , *GAIT in humans , *KINEMATICS , *MOTION , *PELVIC bones , *RADIOGRAPHY , *RESEARCH funding , *FEMUR head - Abstract
Hip joint center (HJC) measurement error can adversely affect predictions from biomechanical models. Soft tissue artifact (STA) may exacerbate HJC errors during dynamic motions. We quantified HJC error and the effect of STA in 11 young, asymptomatic adults during six activities. Subjects were imaged simultaneously with reflective skin markers (SM) and dual fluoroscopy (DF), an x-ray based technique with submillimeter accuracy that does not suffer from STA. Five HJCs were defined from locations of SM using three predictive (i.e., based on regression) and two functional methods; these calculations were repeated using the DF solutions. Hip joint center motion was analyzed during six degrees-of-freedom (default) and three degrees-of-freedom hip joint kinematics. The position of the DF-measured femoral head center (FHC), served as the reference to calculate HJC error. The effect of STA was quantified with mean absolute deviation. HJC errors were (mean±SD) 16.6±8.4mm and 11.7±11.0mm using SM and DF solutions, respectively. HJC errors from SM measurements were all significantly different from the FHC in at least one anatomical direction during multiple activities. The mean absolute deviation of SM-based HJCs was 2.8±0.7mm, which was greater than that for the FHC (0.6±0.1mm), suggesting that STA caused approximately 2.2mm of spurious HJC motion. Constraining the hip joint to three degrees-of-freedom led to approximately 3.1mm of spurious HJC motion. Our results indicate that STA-induced motion of the HJC contributes to the overall error, but inaccuracies inherent with predictive and functional methods appear to be a larger source of error. [ABSTRACT FROM AUTHOR]
- Published
- 2016
- Full Text
- View/download PDF
11. Is adult gait less susceptible than paediatric gait to hip joint centre regression equation error?
- Author
-
Kiernan, D., Hosking, J., O’Brien, T., and O'Brien, T
- Subjects
- *
GAIT in humans , *HIP joint physiology , *ERROR analysis in mathematics , *HEALTH of adults , *CHILDREN'S health , *DYNAMICS , *KINEMATICS , *REGRESSION analysis - Abstract
Hip joint centre (HJC) regression equation error during paediatric gait has recently been shown to have clinical significance. In relation to adult gait, it has been inferred that comparable errors with children in absolute HJC position may in fact result in less significant kinematic and kinetic error. This study investigated the clinical agreement of three commonly used regression equation sets (Bell et al., Davis et al. and Orthotrak) for adult subjects against the equations of Harrington et al. The relationship between HJC position error and subject size was also investigated for the Davis et al. set. Full 3-dimensional gait analysis was performed on 12 healthy adult subjects with data for each set compared to Harrington et al. The Gait Profile Score, Gait Variable Score and GDI-kinetic were used to assess clinical significance while differences in HJC position between the Davis and Harrington sets were compared to leg length and subject height using regression analysis. A number of statistically significant differences were present in absolute HJC position. However, all sets fell below the clinically significant thresholds (GPS <1.6°, GDI-Kinetic <3.6 points). Linear regression revealed a statistically significant relationship for both increasing leg length and increasing subject height with decreasing error in anterior/posterior and superior/inferior directions. Results confirm a negligible clinical error for adult subjects suggesting that any of the examined sets could be used interchangeably. Decreasing error with both increasing leg length and increasing subject height suggests that the Davis set should be used cautiously on smaller subjects. [ABSTRACT FROM AUTHOR]
- Published
- 2016
- Full Text
- View/download PDF
12. Statistical shape modelling versus linear scaling: Effects on predictions of hip joint centre location and muscle moment arms in people with hip osteoarthritis
- Author
-
Jasvir S. Bahl, Thor F. Besier, Dominic Thewlis, Bryce A. Killen, John B. Arnold, David Lloyd, Lucian B. Solomon, Ju Zhang, Mark Taylor, Bahl, Jasvir S, Zhang, Ju, Killen, Bryce A, Taylor, Mark, Solomon, Lucian B, Arnold, John B, Lloyd, David G, Besier, Thor F, and Thewlis, Dominic
- Subjects
Adult ,Male ,Mean squared error ,0206 medical engineering ,Biomedical Engineering ,Biophysics ,02 engineering and technology ,Osteoarthritis, Hip ,03 medical and health sciences ,statistical shape model ,0302 clinical medicine ,Statistics ,Linear scale ,medicine ,Humans ,Orthopedics and Sports Medicine ,Muscle, Skeletal ,Joint (geology) ,Scaling ,Pelvis ,Mathematics ,Models, Statistical ,scaling ,Rehabilitation ,musculoskeletal modelling ,hip joint centre ,020601 biomedical engineering ,Regression ,Biomechanical Phenomena ,Moment (mathematics) ,Euclidean distance ,medicine.anatomical_structure ,Research Design ,Female ,Hip Joint ,Tomography, X-Ray Computed ,030217 neurology & neurosurgery - Abstract
Marker-based dynamic functional or regression methods are used to compute joint centre locations that can be used to improve linear scaling of the pelvis in musculoskeletal models, although large errors have been reported using these methods. This study aimed to investigate if statistical shape models could improve prediction of the hip joint centre (HJC) location. The inclusion of complete pelvis imaging data from computed tomography (CT) was also explored to determine if free-form deformation techniques could further improve HJC estimates. Mean Euclidean distance errors were calculated between HJC from CT and estimates from shape modelling methods, and functional- and regression-based linear scaling approaches. The HJC of a generic musculoskeletal model was also perturbed to compute the root-mean squared error (RMSE) of the hip muscle moment arms between the reference HJC obtained from CT and the different scaling methods. Shape modelling without medical imaging data significantly reduced HJC location error estimates (11.4 ± 3.3 mm) compared to functional (36.9 ± 17.5 mm, p =
- Published
- 2019
13. Predicting the hip joint centre in children: New regression equations, linear scaling, and statistical shape modelling.
- Author
-
Carman, Laura, Besier, Thor F., and Choisne, Julie
- Subjects
- *
HIP joint , *STATISTICAL models , *COMPUTED tomography , *TORQUE , *EQUATIONS , *EUCLIDEAN distance , *GEOMETRIC shapes , *CHILD patients - Abstract
Determination of the hip joint centre (HJC) is important to accurately estimate hip joint motion, moments and muscle forces. The most accurate method for HJC estimation without medical imaging is an area of interest in the biomechanics community, especially in a paediatric population, which has not been widely evaluated. HJC locations were calculated by sphere-fitting to the acetabulum of three-dimensional pelvises segmented from 333 CT scans of children aged 4 to 18 years old. Three methods for determining the HJC were compared: regression equations, linear scaling, and shape model prediction. The new regression equations developed in this study produced Euclidean distance errors of 6.23 mm ± 2.90 mm. Linear scaling of paediatric bone produced errors of 3.90 mm ± 2.52 mm and adult bone scaling of 5.45 mm ± 3.26 mm. Prediction of the HJC using a paediatric statistical shape model produced mean Euclidian distance errors of 2.95 mm ± 1.65 mm. Overall, shape model prediction of the HJC produced the lowest errors, with linear scaling of a mean paediatric pelvis providing better estimates than regression equations. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
14. On the implementation of predictive methods to locate the hip joint centres.
- Author
-
Sangeux, Morgan
- Subjects
- *
PREDICTION models , *HIP joint , *ANTHROPOMETRY , *PELVIS , *SECONDARY analysis , *EQUATIONS , *MAGNETIC resonance imaging - Abstract
The purpose of this short communication is to discuss the relative benefits of various anthropometric parameters to drive predictive equations to locate the hip joint centres. The effect of soft tissue thickness over the anterior and posterior superior iliac spines on pelvic depth, pelvic width and leg length and position of the hip joint centres was discussed theoretically and experimentally, from a secondary analysis of previously published data. Results highlighted that anthropometric measurements of pelvic width and leg length were similar when obtained from MRI images or during gait analysis whereas pelvic depth was different. The secondary analysis showed that Harrington et al. [5] equations using either only pelvic width or only leg length would lead to 3mm improvement, in average over 164 limbs, over the equations using the best anthropometric predictors from MRI data. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
15. Estimation of the hip joint centre in human motion analysis: A systematic review.
- Author
-
Kainz, Hans, Carty, Christopher P., Modenese, Luca, Boyd, Roslyn N., and Lloyd, David G.
- Subjects
- *
HIP joint , *BIOMECHANICS , *DATABASES , *DIAGNOSIS , *GAIT in humans , *RANGE of motion of joints , *KINEMATICS , *SYSTEMATIC reviews , *MOTION capture (Human mechanics) , *ANATOMY - Abstract
Background Inaccuracies in locating the three-dimensional position of the hip joint centre affect the calculated hip and knee kinematics, force- and moment-generating capacity of muscles and hip joint mechanics, which can lead to incorrect interpretations and recommendations in gait analysis. Several functional and predictive methods have been developed to estimate the hip joint centre location, and the International Society of Biomechanics recommends a functional approach for use with participants that have adequate range of motion at the hip, and predictive methods in those with insufficient range of motion. The purpose of the current systematic review was to substantiate the International Society of Biomechanics recommendations. This included identifying the most accurate functional and predictive methods, and defining ‘adequate’ range of motion. Methods A systematic search with broad search terms was performed including five databases. Findings The systematic search yielded to 801 articles, of which 34 papers were included. Eleven different predictive and 13 different functional methods were identified. The results showed that the geometric sphere fit method and Harrington equations are the most accurate functional and predictive approaches respectively that have been evaluated in vivo. Interpretation In regard to the International Society of Biomechanics recommendations, the geometric sphere fit method should be used in people with sufficient active hip range of motion and the Harrington equations should be used in patients without sufficient hip range of motion. Multi-plane movement trials with at least 60° of flexion–extension and 30° of ab-adduction range of motion are suggested when using functional methods. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
16. The clinical impact of hip joint centre regression equation error on kinematics and kinetics during paediatric gait.
- Author
-
Kiernan, D., Malone, A., O’Brien, T., and Simms, C.K.
- Subjects
- *
GAIT in humans , *HIP joint , *KINEMATICS , *REGRESSION analysis , *CHILDREN'S health - Abstract
Regression equations based on pelvic anatomy are routinely used to estimate the hip joint centre during gait analysis. While the associated errors have been well documented, the clinical significance of these errors has not been reported. This study investigated the clinical agreement of three commonly used regression equation sets (Bell et al., Davis et al. and Orthotrak software) against the equations of Harrington et al. Full 3-dimensional gait analysis was performed on 18 healthy paediatric subjects. Kinematic and kinetic data were calculated using each set of regression equations and compared to Harrington et al. In addition, the Gait Profile Score and GDI-Kinetic were used to assess clinical significance. Bell et al. was the best performing set with differences in Gait Profile Score (0.13°) and GDI-Kinetic (0.84 points) falling below the clinical significance threshold. Small deviations were present for the Orthotrak set for hip abduction moment (0.1 Nm/kg), however differences in Gait Profile Score (0.27°) and GDI-Kinetic (2.26 points) remained below the clinical threshold. Davis et al. showed least agreement with a clinically significant difference in GDI-Kinetic score (4.36 points). It is proposed that Harrington et al. or Bell et al. regression equation sets are used during gait analysis especially where inverse dynamic data are calculated. Orthotrak is a clinically acceptable alternative however clinicians must be aware of the effects of error on hip abduction moment. The Davis et al. set should be used with caution for inverse dynamic analysis as error could be considered clinically meaningful. [ABSTRACT FROM AUTHOR]
- Published
- 2015
- Full Text
- View/download PDF
17. Influence of Different Hip Joint Centre Locations on Hip and Knee Joint Kinetics and Kinematics During the Squat.
- Author
-
Sinclair, Jonathan, Atkins, Stephen, and Vincent, Hayley
- Subjects
HIP joint ,RANGE of motion of joints ,HUMAN mechanics research ,HUMAN kinematics ,SQUAT (Weight lifting) ,BIOMECHANICS research - Abstract
Identification of the hip joint centre (HJC) is important in the biomechanical examination of human movement. However, there is yet to be any published information regarding the influence of different HJC locations on hip and knee joint kinetics during functional tasks. This study aimed to examine the influence of four different HJC techniques on 3- D hip and knee joint kinetics/kinematics during the squat. Hip and knee joint kinetics/kinematics of the squat were obtained from fifteen male participants using an eight camera motion capture system. The 3-D kinetics/kinematics of the squat were quantified using four hip joint centre estimation techniques. Repeated measures ANOVAs were used to compare the discrete parameters as a function of each HJC location. The results show that significant differences in joint angles and moment parameters were evident at both the hip and knee joint in the coronal and transverse planes. These observations indicate that when calculating non-sagittal joint kinetics/kinematics during the squat, researchers should carefully consider their HJC method as it may significantly affect the interpretation of their data. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
18. Evaluation of the Estimation Method on the Hip Joint Centre Location During Instep Kicking Motion (P217).
- Author
-
Yamada, Koshi and Maruyama, Takeo
- Abstract
The purpose of this research was to evaluate the estimation methods of the hip joint centre (HJC) location for calculating kinematic parameters of knee and hip joints during dynamic movement, in this reserch, instep kicking motion. Twelve skilled soccer players participated in the experiment. To estimate the HJC location, they were instructed to do ad hoc movements including hip flexion/extension and abduction/adduction movements performed on several planes of different orientations, followed by a circumduction movement. Then, subjects performed their maximal instep kick, which were recorded using motion capture system at 250Hz. The coordinates of the HJC were estimated using three methods and compared. The first used marker coordinates on left and right greater trochanters, the second empirical relations between the HJC location and the length between anterior superior illiac spines, which had been called predictive method, and third bias compensated least squares method, which had been called functional method. Then, maximal hip extention and knee flexion angles during instep kicking motion were calculated based on three methods, and compared statistically. As a result, the hip joint centre location estimated by first method changed so much in the pelvic anatomical frame during dynamic exercise, and maximal hip extension and knee flexion angles were different from results by other two methods significantly. However, predictive methods gave almost the same results as functional method which had been said to be most accurate method in a previous study. Consequently, method using markers on the greater trochanters could not be appropriate for kinematic analysis during dynamic exercise, and predictive method was recommended for use because of its accuracy and easiness for application. [ABSTRACT FROM AUTHOR]
- Published
- 2008
- Full Text
- View/download PDF
19. Hip joint centre position estimation using a dual unscented Kalman filter for computer-assisted orthopaedic surgery.
- Author
-
Beretta, Elisa, De Momi, Elena, Camomilla, Valentina, Cereatti, Andrea, Cappozzo, Aurelio, and Ferrigno, Giancarlo
- Subjects
HIP joint abnormalities ,KNEE surgery ,KALMAN filtering ,ORTHOPEDIC surgery ,SOFT tissue injuries ,THERAPEUTICS - Abstract
In computer-assisted knee surgery, the accuracy of the localization of the femur centre of rotation relative to the hip-bone (hip joint centre) is affected by the unavoidable and untracked pelvic movements because only the femoral pose is acquired during passive pivoting manoeuvres. We present a dual unscented Kalman filter algorithm that allows the estimation of the hip joint centre also using as input the position of a pelvic reference point that can be acquired with a skin marker placed on the hip, without increasing the invasiveness of the surgical procedure. A comparative assessment of the algorithm was carried out using data provided by in vitro experiments mimicking in vivo surgical conditions. Soft tissue artefacts were simulated and superimposed onto the position of a pelvic landmark. Femoral pivoting made of a sequence of star-like quasi-planar movements followed by a circumduction was performed. The dual unscented Kalman filter method proved to be less sensitive to pelvic displacements, which were shown to be larger during the manoeuvres in which the femur was more adducted. Comparable accuracy between all the analysed methods resulted for hip joint centre displacements smaller than 1 mm (error: 2.2 ± [0.2; 0.3] mm, median ± [inter-quartile range 25%; inter-quartile range 75%]) and between 1 and 6 mm (error: 4.8 ± [0.5; 0.8] mm) during planar movements. When the hip joint centre displacement exceeded 6 mm, the dual unscented Kalman filter proved to be more accurate than the other methods by 30% during multi-planar movements (error: 5.2 ± [1.2; 1] mm). [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
20. Which method of hip joint centre localisation should be used in gait analysis?
- Author
-
Sangeux, Morgan, Pillet, Hélène, and Skalli, Wafa
- Subjects
- *
HIP joint , *GAIT in humans , *HUMAN mechanics , *FUNCTIONAL equations , *PREDICTIVE control systems - Abstract
Highlights: [•] Accuracy of predictive and functional hip joint centre estimates against EOS. [•] Functional geometrical sphere fitting technique; 1.1cm from EOS. [•] Harrington et al. predictive equations; 1.7cm from EOS. [•] Predictive equations best suited for population with hip/motor control problems. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
21. The test-retest reliability of three different hip joint centre location techniques.
- Author
-
Sinclair, J., Taylor, P. J., Currigan, G., and Hobbs, S. J.
- Subjects
HIP joint ,STATISTICAL reliability ,KINEMATICS in sports ,STATISTICAL correlation ,RUNNING ,ANATOMY - Abstract
Copyright of Movement & Sport Sciences / Science & Motricité is the property of EDP Sciences and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2014
- Full Text
- View/download PDF
22. Hip joint centre localisation with an unscented Kalman filter.
- Author
-
Momi, Elena De, Beretta, Elisa, and Ferrigno, Giancarlo
- Subjects
- *
HIP joint , *KALMAN filtering , *STOCHASTIC processes , *ANATOMY , *PRESERVATION of organs, tissues, etc. - Abstract
The accurate estimation of the hip joint centre (HJC) in gait analysis and in computer assisted orthopaedic procedures is a basic requirement. Functional methods, based on rigid body localisation, assessing the kinematics of the femur during circumduction movements (pivoting) have been used for estimating the HJC. Localising the femoral segment only, as it is usually done in total knee replacement procedure, can give rise to estimation errors, since the pelvis, during the passive pivoting manoeuvre, might undergo spatial displacements. This paper presents the design and test of an unscented Kalman filter that allows the estimation of the HJC by observing the pose of the femur and the 3D coordinates of a single marker attached to the pelvis. This new approach was validated using a hip joint mechanical simulator, mimicking both hard and soft tissues. The algorithm performances were compared with the literature standards and proved to have better performances in case of pelvis translation greater than 8 mm, thus satisfying the clinical requirements of the application. [ABSTRACT FROM AUTHOR]
- Published
- 2013
- Full Text
- View/download PDF
23. A new method of hip joint moment’s evaluation
- Author
-
Aduayom-Ahego, Akouetevi, Ehara, Yoshihiro, Shimotori, Daiki, and Inoue, Shota
- Subjects
musculoskeletal diseases ,motion analysis ,hip joint moments ,hip joint centre ,mechanical work ,potential energy - Abstract
application/pdf, 論文(Article), Joint moments play very important role in biomechanical research related to lower limbs. Three–dimensional motion analysis is widely used in clinical decision making and sport biomechanics. The accuracy of joint moments is particularly important for data analysis. If the joint moments are not accurate, it will mislead the clinical judgment. However there is no method to verify the accuracy of joint moments. To assess the reliability of the joint moments, a new method should be developed. So a new method based on the principle of the transfer between mechanical lower limb work and potential energy was developed. Five healthy student volunteers participated in the study. The motion data were collected and were processed using VICON motion analysis system. The lower limb work and the potential energy were calculated and compared in four kinds of hip joint centre location estimation models. Using the new concept, one of the four models showed the least difference between the potential energy increase and mechanical work. With this concept, the model in which the most accurate joint moment can be calculated was identified. However, given that these techniques are commonly used in the motion analysis laboratory set by researchers and clinicians, more investigations are needed in order to upgrade laboratory setting and joint center prediction methods.
- Published
- 2018
24. Survey of Formal Methods of Hip Joint Center Calculation in Human Studies.
- Author
-
Upadhyaya, Swati and Lee, Won-Sook
- Abstract
Abstract: Functional hip joint center (HJC) calculation involves recording movements of femur relative to acetabulum through markers placed on skin around thigh and pelvis. This non-invasive method of finding hip joint center involves either fitting a geometric sphere onto marker trajectories or coordinate transformation techniques which find the point with least movement in local frame with respect to global frame. A survey study by Ehrig et al has evaluated both categories of formal methods through virtual simulation and also contributed another algorithm known as “SCoRE”(Systematic center of rotation estimation). This algorithm gives an accuracy of 0.5cm with 20 degree range of motion (ROM) and claimed to be most accurate with both segments in motion. This paper reviews the studies using this method to calculate hip joint center. Also a review of studies using Ultrasound as a validation method has been provided. This forms the basis to the possibility of using Ultrasonic sensors to be placed along with markers to measure the relative movement of markers with respect to bone in vivo. This paper provides a survey of studies performed on human subjects either in vivo (live humans) or ex vivo (cadaver) to help an experimenter or researcher pick the best relevant technique matching their experimentation requirement including soft tissue artifact factor. [Copyright &y& Elsevier]
- Published
- 2013
- Full Text
- View/download PDF
25. Methods of Determining Hip Joint Centre: Their Influence on the 3-D Kinematics of the Hip and Knee During the Fencing Lunge.
- Author
-
Sinclair, Jonathan and Bottoms, Lindsay
- Subjects
HIP fractures ,FENCING ,POSTURE ,KINEMATICS in sports ,JOINT injuries ,KNEE injuries - Abstract
Purpose. The lunge is a fundamental offensive fencing technique, common to all contemporary fencing styles. Therefore, when using 3-D kinematic analysis to quantify lower extremity rotations during the fencing lunge, it is important for researchers to correctly interpret this movement. Locating the centre of the hip is required to accurately quantify hip and knee joint rotations, with three non-invasive techniques using anatomical, functional and projection methods currently available for the estimation of hip joint centre. This study investigated the influence of these three techniques on hip and knee joint kinematics during the fencing lunge. Methods. Three-dimensional kinematics of the lunge were collected from 13 experienced epee fencers using an eight-camera motion capture system. The 3-D kinematics of the lunge were quantified using the three hip joint centre estimation techniques. Repeated measures ANOVAs were used to compare the discrete 3-D kinematic parameters, and intra-class correlations were employed to identify similarity across the 3-D kinematic waveforms from the three techniques. Results. The results indicate that whilst the kinematic waveforms were similar (R
2 ≥0.96); significant differences in discrete parameters were also evident at both the hip and knee joint in the coronal and transverse planes. Conclusions. It appears based on these observations that different hip joint centre locations can significantly influence the resultant kinematic parameters and cannot be used interchangeably. [ABSTRACT FROM AUTHOR]- Published
- 2013
- Full Text
- View/download PDF
26. A hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts.
- Author
-
Camomilla, Valentina, Cereatti, Andrea, Chèze, Laurence, and Cappozzo, Aurelio
- Subjects
- *
HIP joint , *HUMAN kinematics , *MEDICAL artifacts , *TISSUES , *HUMAN mechanics , *MEDICAL photography , *PHOTOGRAMMETRY , *ROBUST control - Abstract
In human movement analysis, accuracy and robustness of the algorithms used to determine the location of centres of rotation from stereophotogrametric data depend mainly on their capacity to deal with the artefacts due to soft tissue deformation (STA). While evaluating these algorithms using a mathematical simulation approach, effectual realizations of STAs are needed. This study aimed at accomplishing this objective by modelling STAs, in twelve selected areas of the thigh, as a linear function of the hip angles, assuming no knee joint movement. The proposed model was calibrated and assessed using ex-vivo experiments. This entailed that only the component of the STA due to skin stretching was accounted for. Photogrammetric data of markers placed on the skin and on hip-bone and femur pins were recorded during passive flexion-extension, ab-adduction, rotation and circumduction of the hip joint. Artefact skin marker displacements were represented in a femur embedded anatomical frame. Model parameters were estimated by minimizing the least squares difference between measured and modelled STAs. The STA affecting a skin marker placed in a given thigh location of a given subject could be modelled with a high accuracy (median root mean square difference over 4 subjects x 3 trials x 12 markers x 3 coordinates: 0.8 mm--inter quartile range 1.0 mm). This was also true for a hip joint movement different from the one used to calibrate the model. High inter-subject variability of the model parameters confirmed the subject-dependency of the phenomenon. [ABSTRACT FROM AUTHOR]
- Published
- 2013
- Full Text
- View/download PDF
27. Sensitivity analysis of hip joint centre estimation based on three-dimensional CT scans.
- Author
-
Bartels, W., Vander Sloten, J., and Jonkers, I.
- Subjects
- *
HIP joint , *FEMUR physiology , *SENSITIVITY analysis , *TOMOGRAPHY , *REGRESSION analysis - Abstract
In morphological analysis of the femur, the hip joint centre (HJC) is generally determined using a 3D model of the femoral head based on medical images. However, the portion of the image selected to represent the femoral head may influence the HJC. We determined if this influence invalidates the results of three HJC calculation methods, one of which we introduce here. To isolate femoral heads in cadaver CT images, thresholds were applied to the distance between femur and acetabulum models. The sensitivity of the HJC to these thresholds and the differences between methods were quantified. For thresholds between 6 and 9 mm and healthy hips, differences between methods were below 1 mm and all methods were insensitive to threshold changes. For higher thresholds, the fovea capitis femoris disturbed the HJC. In two deformed hips, the new method performed superiorly. We conclude that for normal hips all methods produce valid results. [ABSTRACT FROM AUTHOR]
- Published
- 2012
- Full Text
- View/download PDF
28. Subject-specific hip geometry and hip joint centre location affects calculated contact forces at the hip during gait
- Author
-
Lenaerts, G., Bartels, W., Gelaude, F., Mulier, M., Spaepen, A., Van der Perre, G., and Jonkers, I.
- Subjects
- *
OSTEOARTHRITIS , *OSSEOINTEGRATION , *BONE remodeling , *MECHANICAL loads , *GAIT in humans , *CONTACT mechanics , *HIP joint , *MOMENTUM (Mechanics) , *SIMULATION methods & models - Abstract
Abstract: Hip loading affects the development of hip osteoarthritis, bone remodelling and osseointegration of implants. In this study, we analyzed the effect of subject-specific modelling of hip geometry and hip joint centre (HJC) location on the quantification of hip joint moments, muscle moments and hip contact forces during gait, using musculoskeletal modelling, inverse dynamic analysis and static optimization. For 10 subjects, hip joint moments, muscle moments and hip loading in terms of magnitude and orientation were quantified using three different model types, each including a different amount of subject-specific detail: (1) a generic scaled musculoskeletal model, (2) a generic scaled musculoskeletal model with subject-specific hip geometry (femoral anteversion, neck-length and neck-shaft angle) and (3) a generic scaled musculoskeletal model with subject-specific hip geometry including HJC location. Subject-specific geometry and HJC location were derived from CT. Significant differences were found between the three model types in HJC location, hip flexion–extension moment and inclination angle of the total contact force in the frontal plane. No model agreement was found between the three model types for the calculation of contact forces in terms of magnitude and orientations, and muscle moments. Therefore, we suggest that personalized models with individualized hip joint geometry and HJC location should be used for the quantification of hip loading. For biomechanical analyses aiming to understand modified hip joint loading, and planning hip surgery in patients with osteoarthritis, the amount of subject-specific detail, related to bone geometry and joint centre location in the musculoskeletal models used, needs to be considered. [Copyright &y& Elsevier]
- Published
- 2009
- Full Text
- View/download PDF
29. Hip joint centre location: An ex vivo study
- Author
-
Cereatti, Andrea, Donati, Marco, Camomilla, Valentina, Margheritini, Fabrizio, and Cappozzo, Aurelio
- Subjects
- *
HIP joint , *RANGE of motion of joints , *HUMAN mechanics , *PHOTOGRAMMETRY , *MEDICAL photography , *FEMUR , *KINEMATICS - Abstract
Abstract: The human hip joint is normally represented as a spherical hinge and its centre of rotation is used to construct femoral anatomical axes and to calculate hip joint moments. The estimate of the hip joint centre (HJC) position using a functional approach is affected by stereophotogrammetric errors and soft tissue artefacts. The aims of this study were (1) to assess the accuracy with which the HJC position can be located using stereophotogrammetry and (2) to investigate the effects of hip motion amplitude on this accuracy. Experiments were conducted on four adult cadavers. Cortical pins, each equipped with a marker cluster, were implanted in the pelvis and femur, and eight skin markers were attached to the thigh. Recordings were made while an operator rotated the hip joint exploiting the widest possible range of motion. For HJC determination, a proximal and a distal thigh skin marker cluster and two recent analytical methods, the quartic sphere fit (QFS) method and the symmetrical centre of rotation estimation (SCoRE) method, were used. Results showed that, when only stereophotogrammetric errors were taken into account, the analytical methods performed equally well. In presence of soft tissue artefacts, HJC errors highly varied among subjects, methods, and skin marker clusters (between 1.4 and 38.5mm). As expected, larger errors were found in the subject with larger soft tissue artefacts. The QFS method and the distal cluster performed generally better and showed a mean HJC location accuracy better than 10mm over all subjects. The analysis on the effect of hip movement amplitude revealed that a reduction of the amplitude does not improve the HJC location accuracy despite a decrease of the artefact amplitude. [Copyright &y& Elsevier]
- Published
- 2009
- Full Text
- View/download PDF
30. Propagation of the hip joint centre location error to the estimate of femur vs pelvis orientation using a constrained or an unconstrained approach
- Author
-
Cereatti, Andrea, Camomilla, Valentina, Vannozzi, Giuseppe, and Cappozzo, Aurelio
- Subjects
- *
HIP joint , *FEMUR , *PELVIS , *BONES - Abstract
Abstract: To estimate hip joint angles during selected motor tasks using stereophotogrammetric data, it is necessary to determine the hip joint centre position. The question is whether the errors affecting that determination propagate less to the angles estimates when a three degrees of freedom (DOFs) constraint (spherical hinge) is used between femur and pelvis, rather than when the two bones are assumed to be unconstrained (six DOFs). An analytical relationship between the hip joint centre location error and the joint angle error was obtained limited to the planar case. In the 3-D case, a similar relationship was obtained using a simulation approach based on experimental data. The joint angle patterns resulted in a larger distortion using a constrained approach, especially when wider rotations occur. The range of motion of the hip flexion–extension, obtained simulating different location errors and without taking into account soft tissue artefacts, varied approximately 7deg using a constrained approach and up to 1deg when calculated with an unconstrained approach. Thus, the unconstrained approach should be preferred even though its estimated three linear DOFs most unlikely carry meaningful information. [Copyright &y& Elsevier]
- Published
- 2007
- Full Text
- View/download PDF
31. Effects of movement for estimating the hip joint centre
- Author
-
Begon, M., Monnet, T., and Lacouture, P.
- Subjects
- *
HIP joint , *KINEMATICS , *POSTURE , *HUMAN mechanics - Abstract
Abstract: Determination of the hip joint centre (HJC) using a functional approach requires access to the kinematics of various body postures. The present study aimed to determine the combined impact of the nature of the movement, its type and the number of cycles, on the accuracy of HJC estimation. Kinematics noise was modelled based on the deformation of hip and thigh clusters of seven subjects, while perfect ball-and-socket movements (used as reference) were calculated based on the movements of one of the subjects. The noise added to the reference kinematics allowed the simulation of 27 tests. Errors were defined as the Euclidean distance between the estimated and the reference HJC. A nested ANOVA and a multiple comparison procedures were performed on all errors. A test including 10 cycles of three different types of limited movements (flexion-extension, abduction–adduction and circumduction) yielded the greatest accuracy for estimating HJC ( mm). Combining different types of movements allowed improving the accuracy. Given that noise increases as a function of the range of a motion, limited movements proved to be the most accurate; however, 10 cycles were required to achieve such results. For trials involving a single cycle, a large movement proved more efficient. [Copyright &y& Elsevier]
- Published
- 2007
- Full Text
- View/download PDF
32. Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging
- Author
-
Harrington, M.E., Zavatsky, A.B., Lawson, S.E.M., Yuan, Z., and Theologis, T.N.
- Subjects
- *
HIP joint , *CEREBRAL palsy , *MAGNETIC resonance imaging , *GAIT in humans - Abstract
Abstract: The location of the hip joint centre (HJC) is required for calculations of hip moments, the location and orientation of the femur, and muscle lengths and lever arms. In clinical gait analysis, the HJC is normally estimated using regression equations based on normative data obtained from adult populations. There is limited relevant anthropometric data available for children, despite the fact that clinical gait analysis is predominantly used for the assessment of children with cerebral palsy. In this study, pelvic MRI scans were taken of eight adults (ages 23–40), 14 healthy children (ages 5–13) and 10 children with spastic diplegic cerebral palsy (ages 6–13). Relevant anatomical landmarks were located in the scans, and the HJC location in pelvic coordinates was found by fitting a sphere to points identified on the femoral head. The predictions of three common regression equations for HJC location were compared to those found directly from MRI. Maximum absolute errors of 31mm were found in adults, 26mm in children, and 31mm in the cerebral palsy group. Results from regression analysis and leave-one-out cross-validation techniques on the MRI data suggested that the best predictors of HJC location were: pelvic depth for the antero-posterior direction; pelvic width and leg length for the supero-inferior direction; and pelvic depth and pelvic width for the medio-lateral direction. For single-variable regression, the exclusion of leg length and pelvic depth from the latter two regression equations is proposed. Regression equations could be generalised across adults, children and the cerebral palsy group. [Copyright &y& Elsevier]
- Published
- 2007
- Full Text
- View/download PDF
33. Influence of Different Hip Joint Centre Locations on Hip and Knee Joint Kinetics and Kinematics During the Squat
- Author
-
Jonathan Kenneth Sinclair, Stephen Atkins, and Hayley Vincent
- Subjects
Orthodontics ,musculoskeletal diseases ,medicine.medical_specialty ,Biomechanics ,Repeated measures design ,Physical Therapy, Sports Therapy and Rehabilitation ,Squat ,Kinematics ,hip joint centre ,Knee Joint ,musculoskeletal system ,biomechanics ,kinematics ,Section I – Kinesiology ,Physiology (medical) ,Coronal plane ,Physical therapy ,medicine ,lcsh:Sports medicine ,lcsh:RC1200-1245 ,Joint (geology) ,human activities ,Research Article - Abstract
Identification of the hip joint centre (HJC) is important in the biomechanical examination of human movement. However, there is yet to be any published information regarding the influence of different HJC locations on hip and knee joint kinetics during functional tasks. This study aimed to examine the influence of four different HJC techniques on 3- D hip and knee joint kinetics/kinematics during the squat. Hip and knee joint kinetics/kinematics of the squat were obtained from fifteen male participants using an eight camera motion capture system. The 3-D kinetics/kinematics of the squat were quantified using four hip joint centre estimation techniques. Repeated measures ANOVAs were used to compare the discrete parameters as a function of each HJC location. The results show that significant differences in joint angles and moment parameters were evident at both the hip and knee joint in the coronal and transverse planes. These observations indicate that when calculating non-sagittal joint kinetics/kinematics during the squat, researchers should carefully consider their HJC method as it may significantly affect the interpretation of their data.
- Published
- 2014
34. Hip joint centre location from anatomical landmarks for automotive seated posture reconstruction.
- Author
-
Peng, J., Wang, X., Denninger, L., Panda, J., and Van Sint Jan, S.
- Subjects
- *
HIP joint physiology , *PHYSIOLOGY , *POSTURE , *REGRESSION analysis , *FUNCTIONAL analysis , *AUTOMOTIVE engineering - Abstract
The article presents a study on the location of hip joint centre (HJC) from anatomical landmarks (ALs) towards the reconstruction of automotive seated posture. It mentions the difficulty of measuring the centre for the said posture in an automotive environment due to the lack of such landmarks. It also notes the estimation of its location through regression and functional methods.
- Published
- 2013
- Full Text
- View/download PDF
35. Validation of 3-D freehand ultrasound for the determination of the hip joint centre
- Author
-
Peters, Alana, Baker, Richard, and Sangeux, Morgan
- Subjects
- *
MEDICAL imaging systems , *THREE-dimensional imaging , *ULTRASONIC imaging , *HIP joint , *CALIBRATION , *PHYSICAL measurements , *BATHS - Abstract
Abstract: This paper describes the calibration process for 3-D free hand ultrasound (3-DUS). The Cambridge calibration technique was determined to produce the most repeatable and accurate results when determining the location of a reference object within a water bath. This note additionally validates 3-DUS as a potential measurement tool for the determination of the hip joint centre. It shows that 3-DUS can accurately determine the inter-HJC distance to within 4±2mm. This indicates potential for 3-DUS to be used as a gold standard measurement tool in the identification of the hip joint centre. [Copyright &y& Elsevier]
- Published
- 2010
- Full Text
- View/download PDF
36. Survey of Formal Methods of Hip Joint Center Calculation in Human Studies
- Author
-
Won-Sook Lee and Swati Upadhyaya
- Subjects
Engineering drawing ,Engineering ,Artifact (error) ,business.industry ,Coordinate system ,Functional Method ,Thigh ,Motion (physics) ,Functional method ,General Energy ,medicine.anatomical_structure ,SCoRE Algorithm ,Ultrasound ,medicine ,Femur ,Computer vision ,Artificial intelligence ,business ,Range of motion ,Hip Joint Centre ,Instant centre of rotation ,Human - Abstract
Functional hip joint center (HJC) calculation involves recording movements of femur relative to acetabulum through markers placed on skin around thigh and pelvis. This non-invasive method of finding hip joint center involves either fitting a geometric sphere onto marker trajectories or coordinate transformation techniques which find the point with least movement in local frame with respect to global frame. A survey study by Ehrig et al has evaluated both categories of formal methods through virtual simulation and also contributed another algorithm known as “SCoRE”(Systematic center of rotation estimation). This algorithm gives an accuracy of 0.5cm with 20 degree range of motion (ROM) and claimed to be most accurate with both segments in motion. This paper reviews the studies using this method to calculate hip joint center. Also a review of studies using Ultrasound as a validation method has been provided. This forms the basis to the possibility of using Ultrasonic sensors to be placed along with markers to measure the relative movement of markers with respect to bone in vivo. This paper provides a survey of studies performed on human subjects either in vivo (live humans) or ex vivo (cadaver) to help an experimenter or researcher pick the best relevant technique matching their experimentation requirement including soft tissue artifact factor.
- Published
- 2013
- Full Text
- View/download PDF
37. Effects of movement for estimating the hip joint centre
- Author
-
Tony Monnet, Patrick Lacouture, Mickaël Begon, Laboratoire de mécanique des solides (LMS), and Centre National de la Recherche Scientifique (CNRS)-Université de Poitiers
- Subjects
Adult ,Male ,Movement ,Biophysics ,Kinematics ,Models, Biological ,Hip joint centre ,03 medical and health sciences ,Functional method ,0302 clinical medicine ,Statistics ,Range (statistics) ,Humans ,Orthopedics and Sports Medicine ,[PHYS.MECA.BIOM]Physics [physics]/Mechanics [physics]/Biomechanics [physics.med-ph] ,Range of Motion, Articular ,Joint (geology) ,Simulation ,Mathematics ,Single cycle ,Circumduction ,Movement (music) ,Rehabilitation ,[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph] ,030229 sport sciences ,Biomechanical Phenomena ,body regions ,Euclidean distance ,Noise ,Data Interpretation, Statistical ,Hip Joint ,030217 neurology & neurosurgery - Abstract
The determination of hip joint centre (HJC) with functional method requires various postures. The present study assesses the effect of the movement on the accuracy of HJC estimation. The type, the nature of the movement such as the number of cycles were tested with analytic and experimental approaches. Three-dimensional video data were collected for hip movements of seven athletes. Kinematic noise was modelled using data on the deformation of hip and thigh clusters, while perfect ball-and-socket movements (the reference) were computed from the movements of a subject. Virtual kinematic data allowed the implementation of 27 different tests for 500 virtual athletes. HJC location for each test was estimated using a sphere fitting algorithm. An error was defined as the euclidean distance between the estimated and the reference HJC. A nested ANOVA and a multiple comparison procedures were performed with all errors. Average error ranges between 4.0 and 7.9 mm. The accuracy is improved by a variety of postures obtained by dierent types of movement flexion-extension abduction-adduction and circumduction). A limited movement is better than larger range of motion, because the additional postures are too noisy. Lastly, it is interest- ing to acquire several cycles. To conclude, a test composed of 10 limited cycles of flexion-extension, abduction-adduction and circumduction guarantees the greatest accuracy in estimating HJC.
- Published
- 2007
38. Which method of hip joint centre localization should be used in gait analysis?
- Author
-
Morgan Sangeux, Wafa Skalli, and Hélène Pillet
- Subjects
Adult ,Male ,musculoskeletal diseases ,Calibration (statistics) ,Movement ,Population ,Posture ,Biophysics ,Sphere fitting ,Kinematics ,Hip joint centre ,Body Mass Index ,Reference Values ,Range (statistics) ,Humans ,Orthopedics and Sports Medicine ,Range of Motion, Articular ,education ,Child ,Joint (geology) ,Gait ,Simulation ,Mécanique: Biomécanique [Sciences de l'ingénieur] ,Mathematics ,education.field_of_study ,Analysis of Variance ,Cerebral Palsy ,Rehabilitation ,Biomechanical Phenomena ,Kinetics ,Gait analysis ,Calibration ,Female ,Hip Joint ,Range of motion ,Algorithm ,Algorithms - Abstract
Accurate localisation of the hip joint centre is required to obtain accurate kinematics, kinetics and musculoskeletal modelling results. Literature data showed that conclusions drawn from synthetic data, adult normal subjects and cerebral palsy children may vary markedly. This study investigated the localisation accuracy of the hip joint centre against EOS. The EOS system allowed us to register the hip joint centres with respect to the skin markers on standing subjects. A comprehensive set of predictive and functional calibration techniques were tested. For the functional calibration techniques, our results showed that algorithm, range of motion and self-performance of the movement were factors significantly affecting the results. Best results were obtained for comfortable range and self-performance of the movement. The best method in this scenario was the functional geometrical sphere fitting method which localised the hips 1.1. cm from the EOS reference in average and 100% of the time within 3. cm. Worst results for functional calibration methods occurred when the movement was assisted with a reduced range of movement. The best method in this scenario was the Harrington et al. regression equations since it does not rely on a functional calibration movement. Harrington et al. equations put the hips 1.7. cm from the EOS reference in average and 97% of the time within 3. cm. We conclude that accurate localisation of the hip joint centre is possible in gait analysis providing that method to localise the hip joint centres are adapted to the population studied: functional geometrical sphere fitting when hip calibration movements are not a problem and Harrington et al. predictive equations otherwise. We are grateful to VICON® (Oxford, UK) for loaning us the full motion capture system used in this study.
- Published
- 2014
39. Hip joint centre location from anatomical landmarks for automotive seated posture reconstruction
- Author
-
S. Van Sint Jan, L. Denninger, J. Peng, J. Panda, Xuguang Wang, Laboratoire de Biomécanique et Mécanique des Chocs (LBMC UMR T9406), Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR), PSA Peugeot-Citroen, Sochaux, France, parent, Department of Orthopaedics, University of Lubumbashi, Lubumbashi, Democratic Republic of the Congo, and Laboratory of Anatomy, Biomechanics and Organogenesis (LABO) of Université Libre de Bruxelles
- Subjects
Adult ,Models, Anatomic ,media_common.quotation_subject ,0206 medical engineering ,Posture ,Biomedical Engineering ,Bioengineering ,02 engineering and technology ,Pelvis ,Ilium ,03 medical and health sciences ,BIOMECANIQUE ,0302 clinical medicine ,Cadaver ,Image Processing, Computer-Assisted ,HANCHE ,Humans ,Femur ,media_common ,ANATOMICAL LANDMARKS ,[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph] ,General Medicine ,Art ,Anatomy ,020601 biomedical engineering ,HIP JOINT CENTRE ,Computer Science Applications ,Human-Computer Interaction ,Radiography ,Regression Analysis ,Hip Joint ,SEATED POSTURE ,Humanities ,Automobiles ,030217 neurology & neurosurgery - Abstract
38ième congrès de la Société de Biomécanique francophone, MARSEILLE, FRANCE, 06-/09/2013 - 09/09/2013; Measuring hip joint centre (HJC) for seated posture in an automotive environment is a difficult task, because only a very limited number of anatomical landmarks (ALs) can be measured. There exist two classes of methods for estimating HJC location (see Bull et al. 2012 for a short review): regression method and functional method. However, they are not well suited to be directly applied to automotive seated posture. Recently, Bull et al. (2012) showed that the uncertainty in HJC by these two methods applied to automotive seated posture could be up to 4 cm due to errors in AL manual palpation and soft tissue artefacts. Interestingly, Bush and Gutowski (2003) proposed a method of locating HJCs for seated postures only using the right and left anterior superior iliac spines ([R/L]IAS) and the right or left femoral lateral epicondyles of the knee by assuming that the distances between HJC and these three ALs remained constant when changing posture. These distances needed to be firstly determined in an initial reference posture by Seidel's method. However, one strong limitation of Seidel's method is that the palpation of the pubic joint landmark (IPJ) is required, which usually causes volunteers to feel uncomfortable. Similar to the method by Bush and Gutowski, the aim of this study was to explore other ALs than IPJ for determining HJC. More specifically, the ilium ischial tuberosity (IIT) could be an alternative candidate as it can be indirectly estimated with the help of a pressure map by assuming that the highest pressure point corresponds to IIT when seated on a flat hard surface. In this study, data collected by Universite ?Libre de Bruxelles (ULB) from 48 adult cadaveric specimens were used for establishing regression equations. The proposed equations were compared with other existing bony landmark-based methods
- Published
- 2013
40. Hip Joint Center Localization with an Unscented Kalman Filter
- Author
-
Giancarlo Ferrigno, Elisa Beretta, and Elena De Momi
- Subjects
musculoskeletal diseases ,Engineering ,Movement ,Biomedical Engineering ,Bioengineering ,Kinematics ,Translation (geometry) ,Pelvis ,hip joint centre, computer assisted orthopaedic surgery, total knee replacement ,medicine ,Humans ,Computer vision ,Femur ,total knee replacement ,Arthroplasty, Replacement, Knee ,Simulation ,Circumduction ,business.industry ,General Medicine ,Kalman filter ,hip joint centre ,Rigid body ,Computer Science Applications ,Biomechanical Phenomena ,computer assisted orthopaedic surgery ,Human-Computer Interaction ,medicine.anatomical_structure ,Gait analysis ,Hip Joint ,Artificial intelligence ,business ,Algorithms - Abstract
The accurate estimation of the hip joint centre (HJC) in gait analysis and in computer assisted orthopaedic procedures is a basic requirement. Functional methods, based on rigid body localisation, assessing the kinematics of the femur during circumduction movements (pivoting) have been used for estimating the HJC. Localising the femoral segment only, as it is usually done in total knee replacement procedure, can give rise to estimation errors, since the pelvis, during the passive pivoting manoeuvre, might undergo spatial displacements. This paper presents the design and test of an unscented Kalman filter that allows the estimation of the HJC by observing the pose of the femur and the 3D coordinates of a single marker attached to the pelvis. This new approach was validated using a hip joint mechanical simulator, mimicking both hard and soft tissues. The algorithm performances were compared with the literature standards and proved to have better performances in case of pelvis translation greater than 8 mm, thus satisfying the clinical requirements of the application.
- Published
- 2013
41. Die Entwicklung und Validierung effektiver Methoden zur Reduzierung von Hautmarkerartefakten für eine effektive, funktionelle Bestimmung des Hüftgelenkzentrums aus Bewegungsdaten
- Author
-
Kratzenstein, Stefan
- Subjects
skin marker artefacts ,wOCST ,gait analysis ,SCoRE ,hip joint centre ,600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit - Abstract
Die klinische Ganganalyse ist ein Verfahren zur Erfassung der Kinematik des Bewegungsapparates. Sie ermöglicht die Quantifizierung von kinematischen Veränderungen im Krankheitsverlauf und der Evaluierung von Therapieerfolgen. Die Bestimmung von Gelenkzentren ist ein fundamentaler Bestandteil der Ganganalyse, da besonders die Kinematik von Gelenken und deren Belastung im Fokus von Analysen stehen. Die Präzision der Verfahren zur funktionellen Bestimmung von Gelenkzentren wird primär durch Hautmarkerverschiebungsartefakte (STAs) limitiert, wenn sich durch z.B. Hautelastizität der Weichteilmantel samt Hautmarker relativ zum Skelett verschiebt. Wird diese Bewegung als Bewegung des Skeletts interpretiert, kann dies zu falschen klinischen Schlussfolgerungen führen. Während in-silico und in-vitro Studien funktionellen Methoden unter Ausschluss von STAs eine Präzision im Bereich von, Clinical gait analysis is applied to quantify skeletal kinematics in order to assess the kinematic process of diseases and to evaluate therapy outcome. Here, the accurate determination of joint centres plays a key role when joint kinematics and loading are to be investigated. The precision of gait analysis is limited by soft tissue artefacts (STAs), when skin markers move relative to the underlying bone. Is this artefact interpreted as skeletal motion, it can lead to faulty clinical diagnoses. In-vitro investigations without the presence of STAs have demonstrated the effectiveness of mathematical algorithms to determine the center of rotation (CoR) at the hip, with an accuracy of
- Published
- 2013
- Full Text
- View/download PDF
42. Hip joint centre location from anatomical landmarks for automotive seated posture reconstruction
- Author
-
Peng, Junfeng, Wang, X., Denninger, Lisa, Panda, Jules, Van Sint Jan, Serge, Peng, Junfeng, Wang, X., Denninger, Lisa, Panda, Jules, and Van Sint Jan, Serge
- Abstract
SCOPUS: ar.j, info:eu-repo/semantics/published
- Published
- 2013
43. Effects of hip joint centre mislocation on gait kinematics of children with cerebral palsy calculated using patient-specific direct and inverse kinematic models.
- Author
-
Kainz H, Carty CP, Maine S, Walsh HPJ, Lloyd DG, and Modenese L
- Subjects
- Biomechanical Phenomena, Cerebral Palsy diagnosis, Child, Hip Joint diagnostic imaging, Humans, Knee Joint diagnostic imaging, Magnetic Resonance Imaging, Male, Cerebral Palsy physiopathology, Gait physiology, Hip Joint physiopathology, Knee Joint physiopathology, Range of Motion, Articular physiology
- Abstract
Joint kinematics can be calculated by Direct Kinematics (DK), which is used in most clinical gait laboratories, or Inverse Kinematics (IK), which is mainly used for musculoskeletal research. In both approaches, joint centre locations are required to compute joint angles. The hip joint centre (HJC) in DK models can be estimated using predictive or functional methods, while in IK models can be obtained by scaling generic models. The aim of the current study was to systematically investigate the impact of HJC location errors on lower limb joint kinematics of a clinical population using DK and IK approaches. Subject-specific kinematic models of eight children with cerebral palsy were built from magnetic resonance images and used as reference models. HJC was then perturbed in 6mm steps within a 60mm cubic grid, and kinematic waveforms were calculated for the reference and perturbed models. HJC perturbations affected only hip and knee joint kinematics in a DK framework, but all joint angles were affected when using IK. In the DK model, joint constraints increased the sensitivity of joint range-of-motion to HJC location errors. Mean joint angle offsets larger than 5° were observed for both approaches (DK and IK), which were larger than previously reported for healthy adults. In the absence of medical images to identify the HJC, predictive or functional methods with small errors in anterior-posterior and medial-lateral directions and scaling procedures minimizing HJC location errors in the anterior-posterior direction should be chosen to minimize the impact on joint kinematics., (Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.