1. Structural and Functional Evaluation of Coronary Arteries Treated With ABSORB Bioresorbable Vascular Scaffold at 5-Year Follow-Up.
- Author
-
Goncalves-Ramírez LR, Amat-Santos IJ, Altisent OA, Gutiérrez H, Pérez de Prado A, Adeliño R, Gómez I, Fernández-Vázquez F, San Román A, and Puri R
- Subjects
- Absorbable Implants, Acetylcholine, Coronary Angiography, Coronary Vessels diagnostic imaging, Coronary Vessels pathology, Coronary Vessels surgery, Everolimus, Follow-Up Studies, Humans, Nitroglycerin pharmacology, Prosthesis Design, Tomography, Optical Coherence, Treatment Outcome, Drug-Eluting Stents, Percutaneous Coronary Intervention adverse effects
- Abstract
Although complete bioresorbable vascular scaffold (BVS) resorption has been demonstrated at 5-year follow-up, whether corresponding vasomotor function restoration occurs remains unknown. The objective was to simultaneously assess the structural healing response along with vasomotor responses at 5-year follow-up of BVS implantation. We studied consecutive patients treated with ABSORB-BVS at 5-year follow-up (n = 31), who were recruited from a multicenter registry and were contacted to undergo a research protocol-driven repeat coronary angiogram involving intracoronary optical coherence tomography (OCT) and invasive coronary endothelial function testing. Epicardial endothelium-dependent vasomotion was defined as any vasodilatation after intracoronary acetylcholine (ACh), whereas endothelium-independent vasomotion was defined as any vasodilatation after intracoronary nitroglycerine (NTG), using quantitative coronary angiography. The mean implantation time point was 60.5 ± 4.6 months. OCT imaging demonstrated complete scaffold resorption in all patients. New coronary lesions (stenosis >50%) were found in 5 patients (16.1%), 3 of them underwent ad hoc percutaneous revascularization (9.7%). Intracoronary ACh (27 patients) and NTG testing (30 patients) was performed. Quantitative coronary angiography analysis demonstrated vasoconstriction after ACh administration and lack of response to NTG in BVS segments (mean lumen diameter = 2.00 ± 0.61 mm at baseline vs 1.74 ± 0.70 mm post-ACh, p <0.001; 2.05 ± 0.54 mm at baseline vs 2.03 ± 0.50 mm post-NTG, p = 0.69). OCT lumen analysis demonstrated similar vasoconstrictive responses to ACh (mean lumen area = 5.31 ± 2.26 mm
2 at baseline vs 5.12 ± 2.55 mm2 post-ACh, p = 0.007) but had a vasodilatory response to NTG (5.96 ± 2.35 mm2 at baseline vs 6.17 ± 2.55 mm2 post-NTG, p<0.001). In conclusion, complete ABSORB-BVS resorption was demonstrated at 5-year follow-up. However, this healing response was associated with endothelium-dependent vasomotor dysfunction within the BVS segment., (Copyright © 2022 Elsevier Inc. All rights reserved.)- Published
- 2022
- Full Text
- View/download PDF