1. Whole-Cerebrum distortion-free three-dimensional pseudo-continuous arterial spin labeling at 7T.
- Author
-
Zhao C, Shao X, Shou Q, Ma SJ, Gokyar S, Graf C, Stollberger R, and Wang DJ
- Subjects
- Humans, Spin Labels, Arteries, Magnetic Resonance Angiography methods, Cerebrovascular Circulation, Cerebral Cortex, Imaging, Three-Dimensional methods, Brain diagnostic imaging
- Abstract
Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (G
ave = 0.4 mT/m, Gratio = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (Nseg ) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8° ) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR., Competing Interests: Declaration of Competing Interest Samantha J. Ma is an employee of Siemens Healthcare., (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)- Published
- 2023
- Full Text
- View/download PDF