1. Hybrid monoliths with metal-organic frameworks in spin columns for extraction of non-steroidal drugs prior to their quantitation by reversed-phase HPLC.
- Author
-
Giesbers M, Carrasco-Correa EJ, Simó-Alfonso EF, and Herrero-Martínez JM
- Subjects
- Adsorption, Anti-Inflammatory Agents, Non-Steroidal chemistry, Anti-Inflammatory Agents, Non-Steroidal urine, Chromatography, High Pressure Liquid, Chromatography, Reverse-Phase, Flurbiprofen chemistry, Flurbiprofen urine, Humans, Ibuprofen chemistry, Ibuprofen urine, Ketoprofen chemistry, Ketoprofen urine, Limit of Detection, Methylmethacrylates chemistry, Anti-Inflammatory Agents, Non-Steroidal isolation & purification, Flurbiprofen isolation & purification, Ibuprofen isolation & purification, Ketoprofen isolation & purification, Metal-Organic Frameworks chemistry, Solid Phase Microextraction methods
- Abstract
A (glycidyl methacrylate)-co-(ethylene glycol dimethacrylate) polymer (poly(GMA-co-EDMA)) was functionalized with metal-organic frameworks (MOF) and used as a sorbent for solid-phase extraction (SPE). The polymeric sorbent was prepared in-situ by photopolymerization in a previously wall-modified spin column, and then modified with an amino-modified MOF of type NH
2 -MIL-101(Cr). The sorbents were used for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs) from human urine samples. The sorbent was compared with the parent monolith and embedded approach, where the MOF particles are admixed in the polymerization mixture before the in-situ polymerization in the modified spin column. SPE is performed by percolating the sample solutions in a centrifuge, which streamlines the SPE steps. The hybrid composites were characterized by scanning electron microscopy and nitrogen intrusion porosimetry. Three NSAIDs (ketoprofen, flurbiprofen, and ibuprofen) were tested. They were eluted from the sorbent with acidified water-acetonitrile mixtures and subsequently analyzed by reversed-phase HPLC with UV detection. The detection limits varied in the range from 0.1 to 7 μg·L-1 , and the precisions (relative standard deviation) were <14% in all the cases. The recoveries were between 71.0 and 78.0% in spiked urine samples. Graphical abstractA hybrid monolith modified with amino-modified MOF [named NH2 -MIL-101(Cr)] in wall-modified spin columns was prepared. The resulting micro-extraction device was applied to the extraction and preconcentration of non-steroidal anti-inflammatory drugs.- Published
- 2019
- Full Text
- View/download PDF