9 results on '"Ferrulli, F"'
Search Results
2. Characterization of stilbene and EJ-276 scintillators coupled with a large area SiPM array for a fast neutron dose rate detector
- Author
-
Ferrulli, F., Dinar, N., Manzano, L. Gallego, Labalme, M., and Silari, M.
- Published
- 2021
- Full Text
- View/download PDF
3. Analysis and comparison of the Core-to-Valence Luminescence mechanism in a large CLYC crystal under neutron and γ-ray irradiation through optical filtering selection of the scintillation light
- Author
-
Anna Vedda, F. Cova, F. Ferrulli, Ivan Veronese, G. Zorloni, Marco Caresana, Marco Silari, Stefan Gundacker, Nicolaus Kratochwil, Rosalinde Hendrika Pots, Ferrulli, F, Caresana, M, Cova, F, Gundacker, S, Kratochwil, N, Pots, R, Silari, M, Vedda, A, Veronese, I, and Zorloni, G
- Subjects
Materials science ,Photon ,Core to Valence Luminescence ,Physics::Instrumentation and Detectors ,Astrophysics::High Energy Astrophysical Phenomena ,Time Correlated Single Photo Counting ,Linear energy transfer ,Scintillator ,CLYC ,Wavelength-based discrimination ,Pulse shape analysis ,Neutron ,Irradiation ,Electrical and Electronic Engineering ,Instrumentation ,Pulse shape analysi ,Scintillation ,Metals and Alloys ,Condensed Matter Physics ,Surfaces, Coatings and Films ,Electronic, Optical and Magnetic Materials ,Wavelength ,FIS/01 - FISICA SPERIMENTALE ,Radioluminescence ,Atomic physics ,Luminescence - Abstract
7Li enriched Cs2LiYCl6:Ce3+ (CLYC) is a promising inorganic scintillator for real-time γ-ray and fast neutron spectrometry. The neutron/γ-ray discrimination is usually accomplished exploiting the different quenching effects of high Linear Energy Transfer (LET) particles on different scintillation mechanisms, usually by means of the time analysis of the pulse shape. In principle, the emission wavelength information could be used to address the same task. However, a systematic study of the correlations between the CLYC decay time, its radio-luminescence spectrum and the LET of the impinging particle has not yet been performed. We therefore investigated the CLYC scintillation process under neutron and γ-ray irradiation, correlating the time response to the scintillation wavelength spectrum using a 1–inch right cylinder>99% 7Li enriched CLYC. We found that the relative intensity of the Core to Valence Luminescence (CVL) is almost constant with photons in the energy range 20–660 keV, i.e. 0.5–5 keV/μm LET, and is only partially quenched by neutrons. Instead, the direct electron-hole capture scintillation mechanism is completely cut under neutron irradiation. The luminescence in between the deep-Ultraviolet and the Near Ultraviolet region (250–350 nm) might be attributed to both the CVL and the host luminescence, also in thick highly Ce3+-doped crystals.
- Published
- 2021
4. Comparison between CLYC-6 and 3He for thermal neutron detection.
- Author
-
Ferrulli F, Silari M, and Zorloni G
- Subjects
- Gamma Rays, Cesium Radioisotopes, Neutrons
- Abstract
A Cs2LiYCl6:Ce crystal, enriched in 6Li to > 95% (CLYC-6), was investigated for thermal neutron detection: it was characterised in terms of intrinsic efficiency and γ-ray discrimination capability and compared with a 3He counter (partial 3He pressure 2.3 atm). The intrinsic efficiency was determined by irradiating the detectors with thermal neutrons. The γ-ray discrimination capability was evaluated in a mixed neutron/137Cs field. The intrinsic efficiency per unit volume is about a factor of 6.45 larger for CLYC-6 than for the 3He counter. The detectors' performances in the presence of an intense γ-ray background are comparable: up to γ-ray fluence rates of the order of 105 cm-2·s-1, both detectors correctly reject γ-rays. At fluence rates of the order of 106 cm-2·s-1, CLYC-6 starts being affected by count losses due to γ-ray-induced dead time, while the 3He counter starts suffering from pile-up. Above this γ-ray intensity, both detectors are not reliable., (© The Author(s) 2023. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.)
- Published
- 2023
- Full Text
- View/download PDF
5. EURADOS REM-COUNTER INTERCOMPARISON AT MAASTRO PROTON THERAPY CENTRE: COMPARISON WITH LITERATURE DATA.
- Author
-
Zorloni G, Bosmans G, Brall T, Caresana M, De Saint-Hubert M, Domingo C, Ferrante C, Ferrulli F, Kopec R, Leidner J, Mares V, Nabha R, Olko P, Caballero-Pacheco MA, Rühm W, Silari M, Stolarczyk L, Swakon J, Tisi M, Trinkl S, Van Hoey O, and Vilches-Freixas G
- Subjects
- Humans, Radiation Dosage, Neutrons, Radiometry methods, Cyclotrons, Radiotherapy Dosage, Proton Therapy methods
- Abstract
The Maastro Proton Therapy Centre is the first European facility housing the Mevion S250i Hyperscan synchrocyclotron. The proximity of the accelerator to the patient, the presence of an active pencil beam delivery system downstream of a passive energy degrader and the pulsed structure of the beam make the Mevion stray neutron field unique amongst proton therapy facilities. This paper reviews the results of a rem-counter intercomparison experiment promoted by the European Radiation Dosimetry Group at Maastro and compares them with those at other proton therapy facilities. The Maastro neutron H*(10) in the room (100-200 μSv/Gy at about 2 m from the isocentre) is in line with accelerators using purely passive or wobbling beam delivery modalities, even though Maastro shows a dose gradient peaked near the accelerator. Unlike synchrotron- and cyclotron-based facilities, the pulsed beam at Maastro requires the employment of rem-counters specifically designed to withstand pulsed neutron fields., (© The Author(s) 2022. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.)
- Published
- 2022
- Full Text
- View/download PDF
6. Joint EURADOS WG9-WG11 rem-counter intercomparison in a Mevion S250i proton therapy facility with Hyperscan pulsed synchrocyclotron.
- Author
-
Zorloni G, Bosmans G, Brall T, Caresana M, De Saint-Hubert M, Domingo C, Ferrante C, Ferrulli F, Kopec R, Leidner J, Mares V, Nabha R, Olko P, Caballero-Pacheco MÁ, Ruehm W, Silari M, Stolarczyk L, Swakon J, Tisi M, Trinkl S, Van Hoey O, and Vilches-Freixas G
- Abstract
Objective Proton therapy is gaining popularity because of the improved dose delivery over conventional radiation therapy. The secondary dose to healthy tissues is dominated by secondary neutrons. Commercial rem-counters are valuable instruments for the on-line assessment of neutron ambient dose equivalent (H*(10)). In general, however, a priori knowledge of the type of facility and of the radiation field is required for the proper choice of any survey meter. The novel Mevion S250i Hyperscan synchrocyclotron mounts the accelerator directly on the gantry. It provides a scanned 227 MeV proton beam, delivered in pulses with a pulse width of 10 µs at 750 Hz frequency, which is afterwards degraded in energy by a range shifter modulator system. This environment is particularly challenging for commercial rem-counters; therefore, we tested the reliability of some of the most widespread rem-counters to understand their limits in the Mevion S250i stray neutron field. Approach This work, promoted by the European Radiation Dosimetry Group (EURADOS), describes a rem-counter intercomparison at the Maastro Proton Therapy centre in the Netherlands, which houses the novel Mevion S250i Hyperscan system. Several rem-counters were employed in the intercomparison (LUPIN, LINUS, WENDI-II, LB6411, NM2B-458, NM2B-495Pb), which included simulation of a patient treatment protocol employing a water tank phantom. The outcomes of the experiment were compared with models and data from the literature. Main results We found that only the LUPIN allowed for a correct assessment of H*(10) within a 20% uncertainty. All other rem-counters underestimated the reference H*(10) by factors from 2 to more than 10, depending on the detector model and on the neutron dose per pulse. In pulsed fields, the neutron dose per pulse is a fundamental parameter, while the average neutron dose rate is a secondary quantity. An average 150-200 µSv/GyRBE neutron H*(10) at various positions around the phantom and at distances between 186 cm and 300 cm from it was measured per unit therapeutic dose delivered to the target. Significance Our results are partially in line with results obtained at similar Mevion facilities employing passive energy modulation. Comparisons with facilities employing active energy modulation confirmed that the neutron H*(10) can increase up to more than a factor of 10 when passive energy modulation is employed. The challenging environment of the Mevion stray neutron field requires the use of specific rem-counters sensitive to high-energy neutrons (up to a few hundred MeV) and specifically designed to withstand pulsed neutron fields., (Creative Commons Attribution license.)
- Published
- 2022
- Full Text
- View/download PDF
7. A thermal neutron source for the CERN radiation Calibration Laboratory.
- Author
-
Ferrulli F, Silari M, Thomsen F, and Zorloni G
- Abstract
This work presents the design, construction and experimental characterisation of a lightweight and low-cost thermal neutron assembly, to be used with the existing Am-Be source irradiator of CERN radiation Calibration Laboratory (Cal Lab). The assembly consists of a cylindrical moderator (18 cm diameter, 25.5 cm height and 5.5 kg weight) and an optional reflector box (5 cm thick walls, 20 kg weight). The moderator is tailored to fit on the Am-Be source in its irradiation position, while the box encloses the detector under test during the irradiation. The exposure volume delimited by the box is 30 × 30 × 30 cm
3 . The thermal neutron fluence at the exposure location, i.e., 30 cm from the source, was optimized by FLUKA Monte Carlo (MC) simulations. The simulations were validated with measurements performed with a bare3 He proportional counter. The thermal neutron fluence at the nominal irradiation position is 7.43 × 102 cm-2 s-1 with the cylindrical moderator only, and 5.75 × 103 cm-2 s-1 with the cylinder and the reflector box, with the detector placed at the centre of the box. The thermal neutron fluence inside the box is rather uniform (variation <5%)., (Copyright © 2021. Published by Elsevier Ltd.)- Published
- 2021
- Full Text
- View/download PDF
8. Impact of the newly proposed ICRU/ICRP quantities on neutron calibration fields and extended range neutron rem-counters.
- Author
-
Pozzi F, Ferrarini M, Ferrulli F, and Silari M
- Subjects
- Calibration, International Agencies, Neutrons, Radiation Exposure, Radiation Monitoring methods, Radiation Protection standards
- Abstract
In July 2017, the International Commission on Radiation Units and Measurements (ICRU) and the International Commission on Radiological Protection (ICRP) proposed the introduction of new operational quantities for external radiation exposure, with the aim of improving coherence between protection quantities and operational quantities within the system of radiological protection. A change in operational quantities will impact both instrumentation and reference radiation fields used for their calibration. This paper evaluates the potential impact of the new quantity ambient dose, H*, meant to replace ambient dose equivalent, H*(10), on two neutron reference fields, the Am-Be source and the CERF high-energy workplace field, and on the response of two models of extended-range neutron rem counters (LINUS and LUPIN). The conclusions are that calibration procedures should in general not be affected and that changes should only be expected in calibration coefficients. Considering the acceptable measurement uncertainties for operational radiation protection, for the extended-range rem counters changes in their design would not be required for measurements outside particle accelerators shielding and for aircrew dosimetry. One can expect that this type of instrument can still be calibrated with Am-Be source neutrons and employed in neutron fields with energy distributions spanning several decades. For uses in radiation fields with very peculiar neutron energy distribution, a specific workplace field calibration may instead be required.
- Published
- 2019
- Full Text
- View/download PDF
9. Respiratory effects of low versus high tidal volume with or without positive end-expiratory pressure in anesthetized dogs with healthy lungs.
- Author
-
De Monte V, Bufalari A, Grasso S, Ferrulli F, Crovace AM, Lacitignola L, and Staffieri F
- Subjects
- Anesthesia, Anesthetics, Animals, Dogs, Female, Mammary Neoplasms, Animal diagnostic imaging, Mammary Neoplasms, Animal surgery, Radiography, Thoracic, Time Factors, Tomography, X-Ray Computed, Lung drug effects, Positive-Pressure Respiration, Pulmonary Gas Exchange, Respiratory Mechanics, Respiratory Rate, Tidal Volume
- Abstract
OBJECTIVE To evaluate the impact of 2 tidal volumes (T
V s) with or without positive end-expiratory pressure (PEEP) on lung mechanics, aeration, and gas exchange in healthy anesthetized dogs. ANIMALS 40 mixed-breed dogs with healthy lungs. PROCEDURES Anesthetized dogs were randomly assigned to 4 groups (n = 10/group) with different ventilatory settings: TV of 8 mL/kg and PEEP of 0 cm H2 O (low TV group), TV of 8 mL/kg and PEEP of 5 cm H2 O (low TV plus PEEP group), TV of 15 mL/kg and PEEP of 0 cm H2 O (high TV group), or TV of 15 mL/kg and PEEP of 5 cm H2 O (high TV plus PEEP group). Expired CO2 and respiratory rate were titrated on the basis of a predetermined stepwise protocol. Gas exchange, respiratory mechanics, and pulmonary aeration were evaluated by means of CT 30 minutes after starting mechanical ventilation at the assigned setting. RESULTS Partial pressures of arterial and expired CO2 were higher in the low TV and low TV plus PEEP groups than in the high TV and high TV plus PEEP groups. Peak and plateau airway pressures were higher in the PEEP group than in the other groups. Static lung compliance was higher in the high TV plus PEEP group than in the low TV group. Relative percentages of atelectatic and poorly aerated lung were lower in the high TV plus PEEP group than in the other groups. Oxygenation was similar among groups. CONCLUSIONS AND CLINICAL RELEVANCE Differences in TV and PEEP application during mechanical ventilation may affect respiratory function in anesthetized dogs with healthy lungs. Ventilation with a TV of 15 mL/kg and PEEP of 5 cm H2 O significantly improved lung compliance and reduced the amount of atelectatic and poorly aerated lung.- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.