1. Phantom-based standardization of CT angiography images for spot sign detection
- Author
-
Morotti, Andrea, Romero, Javier M, Jessel, Michael J, Hernandez, Andrew M, Vashkevich, Anastasia, Schwab, Kristin, Burns, Joseph D, Shah, Qaisar A, Bergman, Thomas A, Suri, M Fareed K, Ezzeddine, Mustapha, Kirmani, Jawad F, Agarwal, Sachin, Shapshak, Angela Hays, Messe, Steven R, Venkatasubramanian, Chitra, Palmieri, Katherine, Lewandowski, Christopher, Chang, Tiffany R, Chang, Ira, Rose, David Z, Smith, Wade, Hsu, Chung Y, Liu, Chun-Lin, Lien, Li-Ming, Hsiao, Chen-Yu, Iwama, Toru, Afzal, Mohammad Rauf, Cassarly, Christy, Greenberg, Steven M, Martin, Renee’ Hebert, Qureshi, Adnan I, Rosand, Jonathan, Boone, John M, Goldstein, Joshua N, and On Behalf of ATACH-II and NETT Investigators
- Subjects
Biomedical and Clinical Sciences ,Clinical Sciences ,Stroke ,Biomedical Imaging ,Bioengineering ,Clinical Trials and Supportive Activities ,Clinical Research ,Calibration ,Cerebral Hemorrhage ,Computed Tomography Angiography ,Hematoma ,Humans ,Iodine ,Phantoms ,Imaging ,Sensitivity and Specificity ,Software ,Intracerebral hemorrhage ,Spot sign ,CT angiography ,Phantom standardization ,ATACH-II and NETT Investigators ,Neurosciences ,Nuclear Medicine & Medical Imaging ,Clinical sciences - Abstract
PurposeThe CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance.MethodsA custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%.ResultsA total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p
- Published
- 2017