305 results on '"Estenosis aórtica"'
Search Results
2. One-stage neonatal Yasui procedure: Presentation of our surgical experience and a new decision-making algorithm
- Author
-
Consuelo A. Gotor, Enrique García, Francisco J. Arias, Miguel A. Granados, Elena Montañes, Alberto Mendoza, María T. Garcia, and Lorenzo Boni
- Subjects
Neonato ,Enfermedad congénita cardiaca ,Estenosis aórtica ,Arco aórtico ,Procedimiento quirúrgico cardiaco ,Medicine ,Surgery ,RD1-811 - Abstract
Objectives: The aim of this study is to present our experience with three patients who underwent a neonatal Yasui procedure, and to show the new decision-making algorithm. Methods: This is a series of three neonates operated on at our hospital between 2017 and 2022. Results: All the patients underwent a primary Yasui. The duration of cardiopulmonary bypass was 275, 249 and 391 min, in patient 1, 2 and 3, respectively. After surgery, the Intensive Care Unit stay of patients 1, 2 and 3 was 29, 22 and 24 days, respectively. The patients were discharged in good condition. Subsequent complications during follow-up included the need for percutaneous intervention in patient 1 for the implantation of a stent in the right pulmonary branch (at 6 months postoperatively) and a stent in the right ventricle-pulmonary artery conduit (at 42 months). Patient 2 required right ventricle-pulmonary artery conduit replacement and repair of moderate-severe left ventricular outflow tract obstruction at 16 months postoperatively. Patient 3 needed a reoperation at 3 months postoperatively due to aortic arch stenosis at different levels and a residual ventricular septal defect. Currently, all patients are alive with adequate echocardiographic biventricular function. Conclusions: In experienced centers, primary Yasui repair can be performed in the neonatal period with satisfactory results. Resumen: Objetivos: El objetivo de este estudio es presentar nuestra experiencia con tres pacientes sometidos a un procedimiento de Yasui neonatal, y mostrar el nuevo algoritmo de toma de decisiones. Métodos: Se trata de una serie de tres neonatos, operados en nuestro hospital entre 2017 y 2022. Resultados: Todos los pacientes fueron sometidos a un Yasui primario. La duración del bypass cardiopulmonar fue de 275, 249 y 391 minutos, en los pacientes 1, 2 y 3, respectivamente. Tras la cirugía, la estancia en la Unidad de Cuidados Intensivos de los pacientes 1, 2 y 3 fue de 29, 22 y 24 días, respectivamente. Los pacientes fueron dados de alta en buenas condiciones. Las complicaciones posteriores durante el seguimiento incluyeron, la necesidad de intervención percutánea en el paciente 1 para la implantación de un stent en la rama pulmonar derecha (a los seis meses del posoperatorio), y un stent en el conducto ventrículo-pulmonar derecho (a los 42 meses). El paciente 2, requirió la sustitución del conducto ventrículo-pulmonar derecho, y la reparación de la obstrucción moderada-grave del tracto de salida del ventrículo izquierdo, a los 16 meses del posoperatorio. El paciente 3, necesitó una reoperación a los tres meses del posoperatorio, debido a una estenosis del arco aórtico a diferentes niveles, y a una comunicación interventricular residual. Actualmente, todos los pacientes están vivos con una función biventricular ecocardiográfica adecuada. Conclusiones: En centros con experiencia, se puede realizar la reparación primaria de Yasui en el periodo neonatal con resultados satisfactorios.
- Published
- 2024
- Full Text
- View/download PDF
3. Incidence, predictors, and prognostic significance of impaired functional status early after transcatheter aortic valve replacement.
- Author
-
Nuche, Jorge, Ternacle, Julien, Avvedimento, Marisa, Cheema, Asim N., Veiga-Fernández, Gabriela, Muñoz-García, Antonio J., Vilalta, Victoria, Regueiro, Ander, Asmarats, Luis, del Trigo, María, Serra, Vicenç, Bonnet, Guillaume, Jonveaux, Melchior, Esposito, Giovanni, Rezaei, Effat, de la Torre-Hernández, José M., Fernández-Nofrerías, Eduard, Vidal, Pablo, Gutiérrez-Alonso, Lola, and Oteo, Juan Francisco
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2024
- Full Text
- View/download PDF
4. Prevalencia de estenosis aórtica moderada-grave en pacientes con amiloidosis cardiaca en un centro de referencia.
- Author
-
Decotto, Santiago, Corna, Giuliana, Villanueva, Eugenia, Pérez-de Arenaza, Diego, Seropian, Ignacio, Falconi, Mariano, Oberti, Pablo, Aguirre, Maria Adela, Posadas-Martínez, Maria Lourdes, Carretero, Marcelina, Agatiello, Carla R., and Pizarro, Rodolfo
- Subjects
- *
ATRIAL fibrillation , *AORTIC stenosis , *HEART valve diseases , *OLDER people , *AORTIC valve - Abstract
Background: Aortic stenosis (AS) is currently the most common valvular disease, with an estimated prevalence of over 4% in octogenarians. Objective: To describe the prevalence of moderate-severe aortic stenosis (AS) in patients with wild type transthyretin amyloidosis (ATTRwt). Also, describe the clinical features, echocardiographic characteristics and clinical evolution. Method: Retrospective cohort of patients with diagnosis of ATTRwt, belonging to Hospital Italiano de Buenos Aires Institutional Amyloidosis Registry, from 30/11/2007 to 31/05/2021. Patients follow up was carried out through the institution clinical history. The prevalence of moderate-severe AE was estimated and presented as a percentage with its 95% confidence interval (95% CI). The characteristics were compared by groups according to whether or not they had moderate-severe AS. Results: 104 patients with ATTRwt were included. Median follow up was 476 days [interquartile range: 192-749]. Moderate-severe AS prevalence at the ATTRwt time of diagnosis was 10.5% (n = 11; 95% CI: 5-18%). The median age of patients with AS moderate-severe at the time of diagnosis of ATTRwt was 86 years [78-91] and the male sex predominated (82%). Most of the patients had a history of heart failure (n = 8) and atrial fibrillation (n = 8) prior to the diagnosis of ATTRwt. Most of the patients were subclassified as low flow low gradient severe AS group (n = 7). Four patients underwent some intervention on the aortic valve. During follow-up, 5 patients (46%) were hospitalized for decompensated heart failure and 4 (36%) died. Conclusions: In our cohort, the coexistence of both pathologies had a similar prevalence as reported in the international literature. It was an elderly population with a high percentage of atrial fibrillation and history of heart failure. Most of the patients presented with severe AS with low flow low gradient. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
5. Angina in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.
- Author
-
Keller, Lukas S., Nuche, Jorge, Avvedimento, Marisa, Real, Carlos, Farjat-Pasos, Julio, Paradis, Jean-Michel, DeLarochellière, Robert, Poulin, Anthony, Kalavrouziotis, Dimitris, Dumont, Eric, Galhardo, Attilio, Mengi, Siddhartha, Mohammadi, Siamak, and Rodés-Cabau, Josep
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
6. Aurícula derecha: un buen aliado en la estimulación ventricular izquierda durante el implante percutáneo de válvula aórtica
- Author
-
Alba Abril Molina, Mónica Fernández Quero, Rosa M. Cardenal Piris, Agustín Guisado Rasco, Rocío Rodríguez Delgado, Jesús Peña Mellado, Manuel Villa Gil Ortega, and José F. Díaz Fernández
- Subjects
Estenosis aórtica ,Implante percutáneo de válvula aórtica ,Estimulación ventricular izquierda ,Aurícula derecha ,Acceso venoso femoral ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: La estimulación ventricular rápida reduce el gasto cardiaco, proporcionando estabilidad durante el implante percutáneo de válvula aórtica (TAVI). Nuestro objetivo fue evaluar la eficacia y la seguridad de la estimulación ventricular izquierda a través de la guía de alto soporte utilizada para el implante y una guía situada en la aurícula derecha (AD) que actúa como ánodo. Métodos: La estimulación ventricular izquierda se realiza conectando el extremo externo de una guía Safari2 preformada situada en el ventrículo izquierdo al cátodo de un marcapasos temporal, y el ánodo al cuerpo de una guía Emerald insertada en la aurícula mediante un catéter Judkins Right diagnóstico a través de un acceso venoso femoral (punción ecoguiada). El marcapasos se programa con salida máxima (20 V) y sensibilidad anulada. Resultados: Se realizó TAVI transfemoral a 62 pacientes seleccionados (mediana de edad: 79,4 ± 6,5 años) utilizando la técnica de estimulación descrita (25 SAPIEN 3 Ultra, 13 Navitor, 9 ACURATE neo2, 14 Evolut-PRO+ y 1 Myvalve), con éxito en todos los casos (hubo 1 fallo de captura atribuido a la programación del generador del marcapasos). Dos pacientes necesitaron marcapasos transitorio y definitivo posterior por bloqueo auriculoventricular completo durante el procedimiento. No se documentaron complicaciones vasculares derivadas del acceso venoso ni del posicionamiento de la guía en la AD. No aumentaron de manera significativa el tiempo del procedimiento ni la fluoroscopia. La mediana de estancia hospitalaria tras el implante fue de 2 días. Conclusiones: En nuestra serie, la estimulación ventricular izquierda utilizando como ánodo la guía situada en la AD ha demostrado ser una técnica eficaz y segura, sin aumentar significativamente el tiempo de procedimiento, y además aporta la ventaja de disponer de acceso venoso central para un posible marcapasos transitorio urgente.
- Published
- 2023
- Full Text
- View/download PDF
7. Right atrium: a good ally in left ventricular pacing during transcatheter aortic valve implantation
- Author
-
Alba Abril Molina, Mónica Fernández Quero, Rosa M. Cardenal Piris, Agustín Guisado Rasco, Rocío Rodríguez Delgado, Jesús Peña Mellado, Manuel Villa Gil Ortega, and José F. Díaz Fernández
- Subjects
Estenosis aórtica ,Implante percutáneo de válvula aórtica ,Estimulación ventricular izquierda ,Aurícula derecha ,Acceso venoso femoral ,Medicine - Abstract
ABSTRACT Introduction and objectives: Rapid ventricular pacing reduces cardiac output by providing stability during transcatheter aortic valve implantation (TAVI). Our objective is to assess the efficacy and safety profile of left ventricular pacing through the high-support guidewire used for implantation and a guidewire located in the right atrium (RA) functioning as an anode. Methods: Left ventricular pacing is performed by connecting the external end of a Safari2 pre-shaped guidewire located in the left ventricle to the cathode of a temporary pacemaker, and the anode to the body of an Emerald guidewire inserted into the RA using a diagnostic Judkins Right catheter (via ultrasound-guided femoral venous access). Pacemaker was programmed with maximum output (20 V) and null sensitivity. Results: A total of 62 selected patients (median 79.4 ± 6.5 years old) underwent transfemoral TAVI using the pacing technique described (25 patients the SAPIEN 3 Ultra; 13 the Navitor, 9 the ACURATE neo2, 14 the Evolut PRO+, and 1 patient the Myvalve). Procedure was successful in all cases (there was 1 capture failure due to pacemaker programming). Two patients required a temporary and permanent pacemaker due to high-grade atrioventricular block. No vascular complications from venous access were documented, not even from the RA guidewire. Procedural time did not increase significantly, and the median length of stay after implantation was 2 days. Conclusions: In our series, left ventricular pacing using the RA-positioned wire as the anode proved to be effective and safe without increasing procedural time significantly. This procedure also provides the advantage of being able to use the central venous access for possible emergency temporary pacemaker implantation.
- Published
- 2023
- Full Text
- View/download PDF
8. Latest-iteration balloon- and self-expandable transcatheter valves for severe bicuspid aortic stenosis: the TRITON study.
- Author
-
Amat-Santos, Ignacio J., García-Gómez, Mario, de Marco, Federico, Won-Keun, Kim, Brito, Joao, Halim, Jonathan, Jose, John, Sengotuvelu, Gunasekaran, Seth, Ashok, Terkelsen, Christian, Protasiewicz, Marcin, Bonilla, Nelson, García, Bruno, Sánchez-Luna, Juan Pablo, Blasco-Turrión, Sara, González, José Carlos, González-Bartol, Esther, Ijsselmuiden, Alexander J.J., Gómez-Salvador, Itziar, and Carrasco Moraleja, Manuel
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
9. Soluble ST2 levels are related to replacement myocardial fibrosis in severe aortic stenosis.
- Author
-
Arrieta, Vanessa, Jover, Eva, Navarro, Adela, Martín-Núñez, Ernesto, Garaikoetxea, Mattie, Matilla, Lara, García-Peña, Amaia, Fernández-Celis, Amaya, Gainza, Alicia, Álvarez, Virginia, Sádaba, Rafael, and López-Andrés, Natalia
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
10. Implante percutáneo de válvula aórtica con Evolut PRO comparada con la SAPIEN 3: estudio comparativo aleatorizado
- Author
-
Heba M. Elnaggar, Wolfgang Schoels, Marwan S. Mahmoud, Yehia T. Kishk, Matthias Kullmer, Mohamad Dia, and Magdy Algowhary
- Subjects
Estenosis aórtica ,Implante percutáneo de válvula aórtica ,TAVI ,SAPIEN 3 ,Evolut PRO ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: Los avances en la tecnología de implante percutáneo de válvula aórtica (TAVI) han dado lugar a mejores resultados y menos complicaciones en comparación con las generaciones anteriores. Se estudió la incidencia y los determinantes de las fugas periprotésicas (FPP) con las válvulas Evolut PRO y SAPIEN 3, así como otros resultados periprocedimiento y hospitalarios. Métodos: Se seleccionó aleatoriamente a 110 pacientes consecutivos con estenosis aórtica grave programados para TAVI transfemoral para recibir una válvula SAPIEN 3 (n = 59) o una Evolut PRO (n = 51). Las dimensiones anulares se determinaron mediante el dimensionamiento del balón guiado por ecocardiografía transesofágica. Tras el procedimiento y durante la hospitalización se evaluaron los siguientes objetivos: FPV, defectos de conducción, embolización de la válvula, necesidad de una segunda válvula, rotura anular, accidente vascular cerebral, complicaciones vasculares, daño renal agudo y mortalidad intrahospitalaria. También se estudiaron los posibles determinantes anatómicos de la FPV. Resultados: No hubo diferencias basales relevantes entre los 2 grupos en cuanto a las características clínicas y ecocardiográficas. Las complicaciones intrahospitalarias fueron comparables entre ambos tipos de válvulas, excepto una incidencia significativamente mayor de FPV (de grado II o superior) inmediata tras el procedimiento y al alta con las válvulas Evolut PRO en comparación con las SAPIEN 3 (19,6 frente a 6,8% y 5,9 frente a 1,7%, respectivamente). De las variables anatómicas, el ángulo entre el tracto de salida del ventrículo izquierdo y la aorta ascendente, la angulación aórtica y la calcificación tuvieron un impacto significativo en la FPV en las válvulas Evolut PRO. El ángulo entre el tracto de salida del ventrículo izquierdo y la aorta ascendente tuvo una correlación negativa con la profundidad de implantación en las válvulas Evolut PRO, pero no en las válvulas SAPIEN 3. Conclusiones: Ambas válvulas demostraron resultados favorables comparables, excepto por una incidencia significativamente mayor de FPV en los pacientes con válvulas Evolut PRO.
- Published
- 2023
- Full Text
- View/download PDF
11. Impacto de un Heart Team en pacientes con estenosis aórtica candidatos a reemplazo percutáneo.
- Author
-
TRIVI, MARCELO S., CASTRO, MARÍA F., TROSSERO, ROMINA, CURA, FERNANDO A., PICCININI, FERNANDO F., CANDIELLO, ALFONSINA, LAMELAS, PABLO O., HENQUIN, RUTH P., BOTTO, FERNANDO O., and RONDEROS, RICARDO R.
- Subjects
HEART valve prosthesis implantation ,AORTIC valve transplantation ,AORTIC stenosis ,PROSTHETIC heart valves ,OVERALL survival - Abstract
Copyright of Revista Argentina de Cardiología is the property of Sociedad Argentina de Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
12. Coste-efectividad del implante percutáneo de válvula aórtica con SAPIEN 3 en pacientes con bajo riesgo de mortalidad quirúrgica en España
- Author
-
José Manuel Vázquez Rodríguez, Eduardo Pinar Bermúdez, José Luis Zamorano, José Moreu Burgos, José Francisco Díaz-Fernández, Bruno García del Blanco, Archita Sarmah, Pascal Candolfi, Judith Shore, and Michelle Green
- Subjects
España ,Implante percutáneo de válvula aórtica ,Cirugía cardiaca ,Prótesis valvular cardiaca ,Reemplazo quirúrgico de válvula aórtica ,Análisis coste-beneficio ,Análisis coste-efectividad ,Estenosis aórtica ,Bajo riesgo ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: El implante percutáneo de válvula aórtica (TAVI) se introdujo en 2007 como una alternativa a la cirugía a corazón abierto para tratar a pacientes con estenosis aórtica grave sintomática, y desde entonces han aumentado las indicaciones autorizadas. Recientemente, el Placement of Aortic Transcatheter Valve Study (PARTNER) 3 ha demostrado beneficios clínicos con el TAVI con la válvula SAPIEN 3 frente al reemplazo quirúrgico de válvula aórtica (RVAo) en pacientes seleccionados con bajo riesgo de mortalidad quirúrgica. Utilizando los datos del PARTNER 3 junto con datos económicos de España, se evaluó la relación coste-efectividad del TAVI en comparación con el RVAo en pacientes con estenosis aórtica grave sintomática con bajo riesgo de mortalidad quirúrgica. Métodos: Se utilizó un modelo en dos etapas para estimar los costes directos sanitarios y los datos de calidad de vida relacionadas con la salud para TAVI con la válvula SAPIEN 3 y RVAo. Los eventos adversos tempranos relacionados con TAVI del PARTNER 3 se incluyeron en un modelo de Markov, que capturó los resultados a más largo plazo tras TAVI o RVAo. Resultados: El TAVI con SAPIEN 3 mejoró los años de vida ajustados por calidad por paciente (+1,00), con un aumento en el coste frente al RVAo de 6.971 € por paciente. Esto representó una ratio coste-efectividad incremental por año de vida ganado ajustado por calidad de 6.952 € por paciente. Los resultados fueron robustos en los diversos análisis de sensibilidad realizados, en los que el TAVI con SAPIEN 3 se mantiene como una opción coste-efectiva. Conclusiones: El TAVI con SAPIEN 3 es coste-efectivo en comparación con el RVAo en pacientes con estenosis aórtica grave sintomática con bajo riesgo de mortalidad quirúrgica. Estos resultados pueden informar a los decisores políticos en España para facilitar el desarrollo de políticas sobre la selección de opciones terapéuticas en esta población de pacientes.
- Published
- 2023
- Full Text
- View/download PDF
13. Procedimiento de Konno-Rastan en un paciente pediátrico.
- Author
-
Ramírez-Cedillo, David, Feliz-Alcántara, Dalia T., Peña-Juárez, Rocío A., Masini-Aguilera, Italo D., Flores-Flores, Oscar, López-Taylor, Jaime, and Medina-Andrade, Miguel A.
- Subjects
- *
AORTIC valve diseases , *AORTIC stenosis , *AORTIC valve transplantation , *VENTRICULAR outflow obstruction , *CONGENITAL heart disease , *OPERATIVE surgery , *AORTIC valve insufficiency - Abstract
Surgery for obstructive left ventricular outflow tract pathology with aortic valve disease and aortic annulus hypoplasia remains a surgical challenge. Various surgical techniques have been described for aortic annulus enlargement of which the Konno-Rastan procedure is an attractive option; however, it is not very often done due to the high degree of difficulty. It is presented the case of a 15-year-old female patient diagnosed with severe aortic valve stenosis and aortic annulus hypoplasia who underwent aortic annulus enlargement with the Konno-Rastan technique and aortic valve replacement. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
14. Clinical impact of the extent of jeopardized myocardium in patients undergoing transcatheter aortic valve intervention.
- Author
-
Aurigemma, Cristina, Giannico, Maria Benedetta, Burzotta, Francesco, Romagnoli, Enrico, Cangemi, Stefano, Bianchini, Francesco, Bruno, Piergiorgio, Leone, Antonio Maria, Gaspardone, Achille, Crea, Filippo, and Trani, Carlo
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
15. Multimodality imaging in aortic stenosis: new diagnostic and therapeutic frontiers.
- Author
-
Ferrer-Sistach, Elena, Teis, Albert, Bayés-Genís, Antoni, and Delgado, Victoria
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
16. Resultados del implante percutáneo de válvula aórtica en España mediante el Registro de Actividad de Atención Especializada
- Author
-
Andrés Íñiguez-Romo, José Javier Zueco-Gil, Mercedes Álvarez-Bartolomé, José Antonio Baz Alonso, Víctor Alfonso Jiménez Díaz, Rodrigo Estévez Loureiro, Gabriela Veiga Fernández, Dae-Hyun Lee Hwang, Belén Martí-Sánchez, and Jesús Cuervo
- Subjects
Estenosis aórtica ,Reemplazo de la válvula aórtica ,Registro de Actividad de Atención Especializada ,Enfermedad de las válvulas cardiacas ,Implante percutáneo de válvula aórtica ,TAVI ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: El implante percutáneo de válvula aórtica (TAVI) se ha consolidado como tratamiento de la estenosis aórtica grave. Como toda intervención, su seguridad y su efectividad deben monitorizarse en condiciones de práctica real. Para ello, se han analizado los datos del Sistema Nacional de Salud disponibles entre los años 2014 y 2017. Métodos: Se evaluaron todos los pacientes mayores de 50 años con TAVI por vía transfemoral incluidos en el Registro de Actividad de Atención Especializada entre 2014 y 2017 procedentes de centros públicos o concertados. Se hicieron análisis de regresión logísticos para evaluar los factores asociados con la mortalidad y las complicaciones, y modelos binomiales negativos para la estancia media hospitalaria. Se usaron tasas estandarizadas para ajustar diferencias en las variables de efectividad y seguridad entre las diferentes comunidades autónomas, de acuerdo con el alto y bajo volumen de implantación de la técnica, considerando como referencia la mediana nacional (37 implantes por 105 habitantes) durante el periodo de tiempo analizado. Resultados: En total se analizaron 5.454 casos de TAVI. La mortalidad intrahospitalaria pasó del 4,89% en 2014 al 2,7% en 2017. La estancia media hospitalaria descendió de 13,1 días en 2014 a 11,3 en 2017. A pesar de no observar diferencias en la mortalidad entre comunidades autónomas, aquellas con mayor volumen de implantes tuvieron una menor estancia media hospitalaria (OR = 0,88; IC95%, 0,86-0,91; p < 0,01), menor riesgo de infecciones (OR = 0,54; IC95%, 0,32-0,9; p = 0,02) y menor necesidad de marcapasos permanente (OR = 0,77; IC95%, 0,65-0,91; p < 0,01). Conclusiones: El uso de TAVI crece progresivamente en España con resultados cada vez mejores respecto al éxito del implante y la morbimortalidad perioperatoria. La variabilidad interregional en las tasas de implante no se relaciona con la mortalidad observada, pero sí con la morbilidad y la estancia hospitalaria.
- Published
- 2022
- Full Text
- View/download PDF
17. Evolución clínica de los pacientes sometidos a implante de válvula aórtica transcatéter (TAVI)
- Author
-
Aragón Fernández, Carlos, Muñoz San José, Juan Carlos, Tapia Ballesteros, Cristina, Aragón Fernández, Carlos, Muñoz San José, Juan Carlos, and Tapia Ballesteros, Cristina
- Abstract
La estenosis aórtica es la enfermedad valvular cardíaca adquirida más frecuente en la población de edad avanzada. Su prevalencia en mayores de 80 años es superior 4%, y está en aumento progresivo debido al envejecimiento de la población1,2. En los pacientes con estenosis aórtica grave sintomática, el remplazo valvular aórtico quirúrgico ha sido el tratamiento de elección ya que mejora la supervivencia y la calidad de vida respecto al tratamiento médico. Sin embargo, en estos pacientes por la presencia de comorbilidades asociadas a la edad, se desestima el tratamiento quirúrgico por el alto riesgo de intervención que supera los beneficios, con unos pobres resultados del tratamiento médico (un riesgo de mortalidad por cualquier causa a los 5 años de casi el 93%)2,3. En este contexto, el desarrollo de la técnica de implante de una válvula aórtica transcatéter (TAVI), inicialmente descrita por Andersen e introducida para pacientes no operables por Cribier en el año 20024,5, ha supuesto una opción terapéutica actualmente ya aceptada para el tratamiento de pacientes ancianos con alto riesgo quirúrgico6,7,8, debido a la evidencia clínica proveniente de ensayos aleatorizados: mejora su pronóstico y calidad de vida comparado con el tratamiento conservador y con la sustitución valvular quirúrgica9,10. Por tanto, dada la menor esperanza de vida y elevada carga de comorbilidades de esta población, la TAVI representa una opción terapéutica a valorar. Sin embargo, es una técnica que presenta un coste económico alto, por lo que se hace necesario valorar con datos del mundo real el impacto clínico de este procedimiento11. En resumen, en este estudio se pretende valorar la eficacia clínica del implante de TAVI en nuestros pacientes, en el contexto de la vida real de la práctica clínica diaria (fuera de los estudios clínicos, sin límites en la inclusión de pacientes), y obtener datos de su supervivencia tras el implante., Grado en Medicina
- Published
- 2024
18. Estudio de gemelo digital y simulación de flujo hemodinámico en biomodelos de aorta ascendente
- Author
-
Fernández San José, Inés, Sierra Pallarés, José Benito, Baladrón Zorita, Carlos, Fernández San José, Inés, Sierra Pallarés, José Benito, and Baladrón Zorita, Carlos
- Abstract
Actualmente, cuando se realiza un implante percutáneo de válvula aórtica, la posición final de las comisuras es aleatoria, lo que dificulta el acceso coronario y posibles procedimientos futuros. Todavía faltan métodos para conseguir la alineación comisural en la mayoría de los dispositivos TAVI. Por ello, es importante el estudiar la influencia del flujo helicoidal en la arteria aorta ascendente. La dinámica de fluidos computacional (CFD) es una herramienta de gran interés en el análisis de flujos del sistema cardiovascular. En este Trabajo Fin de Grado se lleva a cabo la simulación del flujo hemodinámico de dos arterias aortas, una corresponde a un paciente sano y la otra a un paciente con estenosis aórtica. Para llevar a cabo estas simulaciones se utiliza el software ANSYS Fluent ®. En cada simulación se variará la proporción de velocidad tangencial con respecto a la velocidad axial. Los resultados se utilizarán para analizar la helicidad, la disipación viscosa, el esfuerzo cortante en la pared, el criterio Q y el criterio Lambda 2 en cada uno de los casos de estudio. De esta manera, se podrá comprender el impacto del flujo helicoidal., Grado en Ingeniería Biomédica
- Published
- 2024
19. Implantación de Válvula Aórtica Transcáteter (TAVI). Sedación y Anestesia Regional: Reporte de Caso
- Author
-
Núñez Cacho, Daniel Alberto, Torres Sosa, Manuel Jesús Antonio, Núñez Cacho, Daniel Alberto, and Torres Sosa, Manuel Jesús Antonio
- Abstract
Introduction: Aortic stenosis (AS) due to calcification is the most common valve disease in developed countries, with relevance in geriatric population. It´s characterized by limitation of left ventricular ejection. The prevalence reported worldwide is 1.3% between 65-74 years, 2.8% after 75 years and 9.8% between 80-89 years. After confirming the valve stenosis, patient surgical risk must be established. In low risk patients, the dimensions of the stenosis and vessel size must be considered to choose the model and size of the prothesis based on the echocardiographic evaluation. Decide which replacement technique is most convenient, could be performed with surgical technique or transcutaneous replacement. In patients with intermediate-high risk the transcutaneous technique (TAVI) should be considered as the first option, because evidence has shown better results compared to the surgical technique. Anesthetic management is usually with the patient under general anesthesia or local anesthesia and sedation. The choice of anesthetic technique will depend by the hospital experience in the procedure and surgeon preference. However, recently there has been an increase in reported literature on the safety and effectiveness of local anesthesia with the patient under conscious sedation. Having advantages such as greater hemodynamic stability, less effect on preload, surgical time reduction, immediate neurological assessment, fewer days of hospital stay and decrease in the mortality rate. Clinical case: A clinical case is presented of a 62 years female patient who underwent transcatheter aortic valve implantation, managed with intravenous sedation and femoral nerve block. Conclusions: The anesthetic technique with patient under sedation has proven to be useful and safe in the management of transcatheter aortic valve implantation, taking into consideration adequate anesthetic depth to avoid involuntary movements and possible complications. Femoral nerve block is useful as an ad, Introducción: La estenosis aórtica (EA) por calcificación es la valvulopatía más común en los países desarrollados, teniendo gran relevancia en la población geriátrica. Se caracteriza por la limitación de la eyección del ventrículo izquierdo. La prevalencia reportada a nivel mundial es de 1.3% entre los 65-74 años, 2.8% después de los 75 años y 9.8% entre los 80-89 años. Después de confirmar la estenosis valvular se debe establecer el riesgo quirúrgico del paciente. En pacientes de bajo riesgo se deben considerar la dimension de la estenosis y el tamaño del vaso para elegir el modelo y tamaño de la prótesis basandose en la evaluación ecocardiográfica; así como poder decidir que técnica de reemplazo es más conveniente, ya sea técnica quirúrgica o transcutánea; en pacientes con riesgo intermedio-alto se debe considerar la técnica transcutanea (TAVI) como primer opción debido a que ha demostrado mejores resultados en comparación con la técnica quirúrgica. El manejo anestésico suele ser con el paciente bajo anestesia general o anestesia local y sedación; la elección de la técnica anestésica dependerá de la experiencia del hospital en el procedimiento y preferencia del cirujano. Sin embargo, recientemente hay un incremento en lo reportado en la literatura sobre la seguridad y eficacia de la anestesia local con el paciente bajo sedación consciente. Teniendo ventajas como mayor estabilidad hemodinámica, menor afección en la precarga, disminución en el tiempo quirúrgico, valoración neurológica inmediata, menos días de estancia hospitalaria y disminución en la tasa de mortalidad. Caso clínico: Se presenta un caso clínico de un paciente femenino de 62 años de edad que fue intervenida para implantación de válvula aórtica transcatéter, manejada con sedación endovenosa y bloqueo de nervio femoral. Conclusiones: La técnica anestésica con el paciente bajo sedación ha demostrado ser útil y segura en el manejo de la implantación valvular aórtica transcatéter, teniendo en considerac
- Published
- 2024
20. Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty
- Author
-
Campelo-Parada, Francisco et al., Nombela-Franco, Luis, Rodés-Cabau, Josep, Pérez Castellano, Nicasio, Macaya Miguel, Carlos, Campelo-Parada, Francisco et al., Nombela-Franco, Luis, Rodés-Cabau, Josep, Pérez Castellano, Nicasio, and Macaya Miguel, Carlos
- Abstract
Introduction and objectives: Little is known about the timing of onset and outcome of conduction abnormalities (CA) following balloon-expandable transcatheter aortic valve implantation. The aim of this study was to examine the timing of CA and determine the impact of balloon aortic valvuloplasty (BAV) on the persistence of these abnormalities. Methods: A total of 347 patients were included. Of these, 75 had a continuous electrocardiogram recording and a 6-lead electrocardiogram at each step of the procedure. Results: In the transcatheter aortic valve implantation population undergoing continuous electrocardiogram monitoring, new-onset left bundle branch block (LBBB) or third-degree atrioventricular block occurred in 48 (64%) and 16 (21.3%) patients, with 51.5% of CA occurring before valve implantation. Left bundle branch block persisted more frequently at hospital discharge (53.8 vs 22.7%; P=.028) and at 1-month follow-up (38.5 vs 13.6%; P=.054) when occurring before valve implantation. Balloon aortic valvuloplasty prior to valve implantation was used in 264 (76.1%) patients, and 78 (22.5%) had persistent LBBB or complete atrioventricular block requiring pacemaker implantation. Persistent LBBB or unresolved atrioventricular block at 1 month occurred more frequently in the BAV group (76.1 vs 47.6%; P=.021), and the use of BAV was associated with a lack of CA resolution (OR, 3.5; 95%CI, 1.17-10.43; P=.021). Conclusions: In patients undergoing a balloon-expandable transcatheter aortic valve implantation, more than half of CA occurred before valve implantation. Early occurrence of CA was associated with a higher rate of persistence at 1-month follow-up. The use of BAV was associated with an increased risk of CA persistence., Depto. de Medicina, Fac. de Medicina, TRUE, pub
- Published
- 2024
21. The novel balloon-expandable Myval transcatheter heart valve: systematic review of aortic, mitral, tricuspid and pulmonary indications.
- Author
-
García-Gómez M, Fernández-Cordón C, González-Gutiérrez JC, Serrador A, Campo A, Cortés Villar C, Blasco Turrión S, Aristizábal C, Peral Oliveira J, Stepanenko A, González Arribas M, Scorpiglione L, Jain A, Carnicero Martínez D, San Román JA, and Amat-Santos IJ
- Abstract
Introduction and Objectives: Myval technology represents the first balloon-expandable alternative since the Edwards system became commercially available. Despite certain controversies, its use has rapidly expanded. We aimed to gather all the available literature regarding its indications and outcomes., Methods: A comprehensive search of articles published between December 2016 and May 2024 was conducted using BioMedCentral, Google Scholar, and PubMed to evaluate the main outcomes of Myval for native aortic stenosis (AS) (meta-analysis) and off-label uses (systematic review)., Results: A total of 151 studies were identified, and 74 were included in the analysis, covering aortic (n=51), mitral (n=9), tricuspid (n=6), and pulmonary (n=8) valve positions. A meta-analysis of studies on native AS demonstrated that Myval is safe and effective, with a 30-day mortality rate of 1.3%, good hemodynamic performance, low rates of pacemaker implantation (8.8%), and ≥ moderate paravalvular regurgitation (1.3%). Compared with other contemporary devices, Myval was competitive and associated with lower rates of pacemaker implantation. In a systematic review of off-label indications, Myval was also found to be safe and effective. In bicuspid AS, pure regurgitation, and aortic valve-in-valve procedures, success rates were 100%, 92%, and 100%, respectively, with pacemaker rates of 9.9%, 22.2%, and 3%, respectively. For mitral valve-in-valve/in-ring procedures, the success rate was 96.9%, while in tricuspid and pulmonary positions, small case series reported 100% success rates for both, with minimal procedural complications., Conclusions: Myval technology is safe and effective for the treatment of native valvular disease and dysfunctional prostheses or rings in all heart valve positions, although larger scale studies are warranted., (Copyright © 2024 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
22. Pronóstico de pacientes nonagenarios tras implante percutáneo de válvula aórtica
- Author
-
Pedro L. Cepas-Guillén, Ander Regueiro, Darío Sanmiguel Cervera, Roberto Blanco Mata, Juan Francisco Oteo, Ignacio Amat-Santo, Francisco Ten, Juan Manuel Nogales, Eduard Fernández-Nofrerías, Vicente Mainar, Garikoit Lasa-Larraya, Leire Andraka, José Antonio Baz-Alonso, María Cruz Ferrer, Eduardo Pinar, Rafael Romaguera, Carlos Cuellas Ramón, Fernando Alfonso, Cristóbal A. Urbano-Carrillo, Sergio García-Blas, Antonio Piñero, Agustín Albarrán, Rafael Ruiz-Salmerón, José Moreu, Óscar Gil Albarova, José M. Melero, Tomás Heredia Cambra, Xavier Freixa, and Manel Sabaté
- Subjects
tavi ,estenosis aórtica ,nonagenarios ,ancianos ,Internal medicine ,RC31-1245 - Abstract
Introducción y objetivos: Los nonagenarios son un grupo de edad en rápido crecimiento entre los pacientes cardiovasculares, en especial con estenosis aórtica, pero los datos sobre su pronóstico después de la implantación transcatéter de válvula aórtica (TAVI) son escasos. El objetivo de este estudio es analizar las características basales de los nonagenarios tratados con TAVI y determinar si la edad "65; 90 años está relacionada con un peor pronóstico en comparación con los pacientes no nonagenarios. Métodos: Se incluyó a todos los pacientes "65; 75 años inscritos en el registro prospectivo multicéntrico español de TAVI entre 2009 y 2018. Se excluyó a aquellos < 75 años. Resultados: Se inscribieron en el registro español de TAVI 8.073 pacientes "65; 75 años de 46 centros de España; 7.686 de > 75 a 90 años (95,2%) y 387 nonagenarios (4,79%). Se observó un aumento progresivo de los nonagenarios. El acceso transfemoral se utilizó en el 91,6% de los casos, predominantemente en los nonagenarios (91,4 frente a 95,1%; p = 0,01). Los nonagenarios tenían más probabilidades de morir durante la hospitalización (4,3 frente a 7,0%; p = 0,01). Sin embargo, no hubo diferencia en la tasa de mortalidad por cualquier causa al año de seguimiento (8,8 frente a 11,3%; p = 0,07). En el análisis multivariable, la edad "65; 90 años no se asoció de forma independiente con un aumento de la mortalidad por cualquier causa ajustada (HR = 1,37; IC95%, 0,91-1,97; p = 0,14). La creatinina basal y las complicaciones hemorrágicas intrahospitalarias se asociaron a un peor pronóstico a largo plazo en pacientes nonagenarios tratados con TAVI. Conclusiones: Los nonagenarios son una población creciente y de muy alto riesgo, con estenosis aórtica grave, para quienes la TAVI podría representar una estrategia segura y efectiva. Una cuidadosa selección de los pacientes por un equipo multidisciplinario la máxima eficiencia en esta población, en la que la función renal basal y las complicaciones hemorrágicas pueden determinar el pronóstico a largo plazo tras la TAVI.
- Published
- 2021
- Full Text
- View/download PDF
23. Quantitative flow ratio for evaluation of borderline coronary lesions in patients with severe aortic stenosis.
- Author
-
Kleczynski, Pawel, Dziewierz, Artur, Rzeszutko, Lukasz, Dudek, Dariusz, and Legutko, Jacek
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
24. Resultados del TAVI emergente comparado con el procedimiento electivo: metanálisis
- Author
-
Álvaro Aparisi, Sandra Santos-Martínez, José Raúl Delgado-Arana, Tania Rodríguez-Gabella, Alfredo Redondo, Hipólito Gutiérrez, Gema Pastor, Carlos Veras, Mario García Gómez, Carlos Baladrón, Manuel Carrasco-Moraleja, José Alberto San Román, and Ignacio J. Amat-Santos
- Subjects
Shock cardiogénico ,Insuficiencia cardiaca ,Implante percutáneo de válvula aórtica ,Estenosis aórtica ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: El implante percutáneo de válvula aórtica (TAVI) ha demostrado ser seguro y eficaz en pacientes tanto de bajo como de alto riesgo, pero los procedimientos emergentes se han excluido en los principales estudios. El objetivo fue determinar los resultados actuales y los condicionantes del pronóstico durante el TAVI emergente. Métodos: Se realizó una búsqueda sistemática en PubMed y Google Scholar de cualquier estudio que comparara el TAVI electivo frente al emergente. Los términos empleados fueron «emergent» y/o «urgent», «elective», y «transcatheter valve replacement» y/o «heart failure» y/o «cardiogenic shock». Se consideró TAVI emergente todo procedimiento no programado realizado para tratar la insuficiencia cardiaca refractaria o el shock cardiogénico. Se utilizó un modelo de efectos aleatorios. Resultados: Se incluyeron 7 estudios (84.427 pacientes) tratados con TAVI (14.241 emergentes y 70.186 electivos). Los casos electivos presentaron una mayor puntuación de riesgo (EuroSCORE logístico 65,9 ± 21 frente a 29,4 ± 18%, p
- Published
- 2021
- Full Text
- View/download PDF
25. Reemplazo valvular aórtico transcatéter (RVAT): manejo perioperatorio y consideraciones anestésicas
- Author
-
Maximiliano Zamora H.
- Subjects
estenosis aórtica ,reemplazo valvular aórtico quirúrgico ,reemplazo valvular aórtico transcatéter ,balón expandible ,autoexpandible ,Medicine ,Anesthesiology ,RD78.3-87.3 - Published
- 2021
- Full Text
- View/download PDF
26. Tratamiento moderno de la estenosis aórtica: reemplazo valvular aórtico 2022.
- Author
-
Turner, Eduardo and Piccinini, Fernando
- Abstract
Copyright of Revista Médica Clínica Las Condes is the property of Editorial Sanchez y Barcelo and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
27. Documento de consenso de la figura TAVI Nurse del Grupo de Trabajo de Hemodinámica de la Asociación Española de Enfermería en Cardiología.
- Author
-
González Cebrián, Miryam, Valverde Bernal, Jonatan, Bajo Arambarri, Ester, Castillo Poyo, Rocío, Trilla Colominas, Marc, Neiro Rey, Carmen, Fradejas Sastre, Víctor, García Aranda, Francisco Javier, Villalba Lizandra, Núria, and Calvo Barriuso, Elena
- Subjects
OCCUPATIONAL roles ,PREOPERATIVE care ,COGNITION disorders ,PATIENT aftercare ,HEART valve prosthesis implantation ,NONPROFIT organizations ,FRAIL elderly ,AORTIC stenosis ,ACTIVITIES of daily living ,POSTOPERATIVE care ,PATIENTS ,HOSPITAL admission & discharge ,HEALTH care teams ,NURSES ,CLINICAL competence ,MEDICAL history taking ,QUALITY of life ,GROUP process ,MEDICAL needs assessment ,DISCHARGE planning - Abstract
Copyright of Enfermería en Cardiologia is the property of Asociacion Espanola de Enfermeria en Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
28. REEMPLAZO ENDOVASCULAR AÓRTICO EN UN PACIENTE CON ENFERMEDAD DE VÁLVULA AÓRTICA BICÚSPIDE.
- Author
-
MATTI, SOFÍA, ESTRELLA, MARÍA LAURA, NAPOLI LLOBERA, MARIANO, COLLA, JULIÁN, BLANCO, RODRIGO, BLANCO, FEDERICO, SZARFER, JORGE, and GAGLIARDI, JUAN A.
- Abstract
Copyright of Medicina (Buenos Aires) is the property of Medicina (Buenos Aires) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
29. Contribución del acortamiento longitudinal y circunferencial al volumen sistólico y fracción de eyección en la estenosis aórtica grave.
- Author
-
ALBERTO MIGLIORE, RICARDO, ADANIYA, MARÍA ELENA, DANIEL DORSCH, JEREMÍAS, BARRANCO, MIGUEL, CONSUELO GONZÁLEZ, SILVIA, and MIGUEL MIRAMONT, GUILLERMO
- Subjects
DOPPLER echocardiography ,AORTIC stenosis ,VENTRICULAR ejection fraction ,BASES (Architecture) - Abstract
Copyright of Revista Argentina de Cardiología is the property of Sociedad Argentina de Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
30. Evaluación de la contractilidad del ventrículo izquierdo en pacientes con estenosis aórtica grave, flujo bajo, gradiente bajo y fracción de expulsión preservada.
- Author
-
Migliore, Ricardo A., Adaniya, María E., Barranco, Miguel, González, Silvia, and Miramont, Guillermo
- Subjects
- *
DOPPLER echocardiography , *AORTIC stenosis , *INDEPENDENT variables , *AORTIC valve , *BIVARIATE analysis - Abstract
Introduction: In patients with severe aortic stenosis, low-gradient, low-flow and preserved ejection fraction (≥ 50%) (LG/LFp) the decrease in stroke volume index (Svi) could be due to diminished contractility. The aim of this study was to analyze if low Svi in patients with LG/LFp is related to a decrease in contractility. Methods: Thirty patients with LF/LGp and 63 normal subjects were studied with Doppler echocardiography. The level of contractility (LC) was assessed by mean of midwall shortening fraction (mSF) - end-systolic stress (ESS) relationship. Relative wall thickness (RWT) and aortic valve area (AVA) were calculated. Results: LC was diminished in 40% of LF/LGp patients. By bivariate analysis LC correlated with RWT and mSF. Svi correlated with AVA but not with LC. In multiple linear regression RWT and mSF were predictors independents of LC. About Svi, AVA was the only predictor independent variable. Conclusion: Decreased contractility was present in 40% of LF/LGp patients despite preserved ejection fraction. LC had correlation with mSF and EPR. Low Svi appears to be related to aortic stenosis severity rather than low contractility. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
31. Self-expandable transcatheter heart valves for aortic stenosis. Short-term outcome and matched hemodynamic performance.
- Author
-
Vera Vera, Silvio, Nombela-Franco, Luis, Santos-Martínez, Sandra, Moreno, Raúl, Jiménez-Díaz, Victor A., Rodríguez-Gabella, Tania, Catalá, Pablo, Castro-Mejía, Alex F., Galeote, Guillermo, Baz, José Antonio, Gutiérrez, Hipólito, Serrador, Ana, García-Gómez, Mario, Redondo, Alfredo, Baladrón, Carlos, Arnold, Roman, Jiménez-Quevedo, Pilar, Carrasco-Moraleja, Manuel, Gómez Salvador, Itziar, and San Román, J. Alberto
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
32. Prevalencia, predictores e impacto clínico de la rehospitalización en pacientes con estenosis valvular aórtica valorados por un Heart Team.
- Author
-
GARMENDIA, CRISTIAN M., SEROPIAN, IGNACIO M., CHIABRANDO, JUAN G., MEDINA DE CHAZAL, HORACIO, CAL, MARIELA, KOTOWICZ, VADIM, FALCONI, MARIANO, OBERTI, PABLO, AGATIELLO, CARLA R., and BERROCAL, DANIEL H.
- Abstract
Copyright of Revista Argentina de Cardiología is the property of Sociedad Argentina de Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
33. Experiencia multicéntrica con prótesis valvular aórtica transcatéter de segunda generación reposicionable y recuperable
- Author
-
Daniele Gemma, Raúl Moreno, Mariano Larman, Rui Campante Teles, Lino Patricio, Eduardo Molina, Vasco Gama Ribeiro, Bruno García Del Blanco, Roque Arana Granado, Santiago Jiménez Valero, Guillermo Galeote, Harold Hernández, Francisco Javier Irazusta Córdoba, Vicenç Serra, and José Luis López-Sendón
- Subjects
Prótesis aórtica transcatéter ,Estenosis aórtica ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: El dispositivo Lotus (Boston Scientific, Estados Unidos) es una prótesis valvular aórtica transcatéter de segunda generación, completamente recuperable y reposicionable. Se presenta la experiencia inicial con la prótesis Lotus en un registro multicéntrico. Métodos: Estudio observacional que reporta los resultados a corto y largo plazo del implante transfemoral de prótesis Lotus entre marzo de 2014 y abril de 2016 en 8 centros de España y Portugal. Resultados: Se incluyeron 102 pacientes (edad media 80,4 ± 6,1 años, índice STS medio 5,2% ± 3,3%) con estenosis aórtica grave sintomática (área valvular media 0,66 ± 0,17 cm2, gradientes 74,3/45,6 mmHg). Se implantó con éxito el dispositivo en 100 pacientes (98%), con mejoría significativa de los gradientes máximo y medio valvular, y un solo caso de regurgitación periprotésica moderada. No hubo ninguna embolización ni necesidad de implante de una nueva prótesis intravalvular. Hasta el alta hospitalaria, la mortalidad fue del 3,9% y la tasa de ictus fue del 2,9%. En 33 pacientes (32,3%) fue necesario el implante de marcapasos definitivo. Conclusiones: La válvula Lotus es eficaz y segura para el tratamiento de pacientes con estenosis aórtica grave sintomática. Destacan la escasa tasa de insuficiencia periprotésica y la ausencia de complicaciones derivadas del mal posicionamiento o la embolización de la prótesis, a costa de un alta incidencia de implante de marcapasos.
- Published
- 2020
- Full Text
- View/download PDF
34. Determinantes de la fracción de eyección ventricular izquierda en pacientes con estenosis aórtica grave.
- Author
-
ALBERTO MIGLIORE, RICARDO, ADANIYA, MARÍA ELENA, FRANCO CAMACHO, MIJAIL IVÁN, ÁNGEL BARRANCO, MIGUEL, MILLES HONORES, JOSELYN, KARINA COBOS, SILVIA, and MIRAMONT, GUILLERMO
- Abstract
Copyright of Revista Argentina de Cardiología is the property of Sociedad Argentina de Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
35. Ventrículo suicida, una paradoja.
- Author
-
López Domènech, Gemma, Martínez Font, Sara, Burgués Miró, Ana Carmen, Prats Barrera, Judith, and Querol Vallés, Elena
- Subjects
PAIN management ,CARDIOPULMONARY resuscitation ,HEART valve prosthesis implantation ,AORTIC stenosis ,SURGICAL complications ,HEART ventricles ,HEART block ,VENTRICULAR outflow obstruction ,MENTAL depression ,CARDIAC pacemakers ,ANXIETY disorders ,NURSING assessment - Abstract
Copyright of Enfermería en Cardiologia is the property of Asociacion Espanola de Enfermeria en Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
36. Metodología para discernir entre sonido cardiaco no patológico de regurgitación y estenosis aórtica, empleando DTW
- Author
-
Rosario Ríos-Prado, Álvaro Anzueto-Ríos, and Blanca Tovar-Corona
- Subjects
Alineamiento Temporal Dinámico ,estenosis aórtica ,fonocardiograma ,regurgitación aórtica ,sonido cardiaco ,Science (General) ,Q1-390 - Abstract
En este artículo se describe la metodología empleada para adquirir, almacenar y procesar señales de sonido cardiaco con el objetivo de comparar las señales de sonidos patológicos con los no patológicos y determinar las fronteras de decisión correspondientes para una futura clasificación. Las señales de sujetos no patológicos se han adquirido con el sistema propuesto en este documento, el cual se ha diseñado considerando las frecuencias tanto de sonidos patológicos como no patológicos. Dos casos, uno de estenosis aórtica y otro de regurgitación aórtica, obtenidos de un sitio público, se han analizado para efectuar las comparaciones. Empleando el algoritmo computacional de Alineamiento Temporal Dinámico se evaluó la similitud que existe en la forma de las señales no patológicas y patológicas. Los resultados han ayudado a proponer las fronteras de decisión de separación entre las clases de señales.
- Published
- 2019
- Full Text
- View/download PDF
37. Prognostic value of aortic valve area normalized to body size in native aortic stenosis.
- Author
-
Gamaza Chulián, Sergio, Díaz Retamino, Enrique, Carmona García, Rocío, Serrano Muñoz, Bárbara, León Jiménez, Javier, González Estriégana, Soraya, and Oneto Otero, Jesús
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
38. The impact of COVID-19 in patients with severe aortic stenosis: Artificial intelligence research
- Author
-
Luis Rodríguez-Padial, Luis Manuel Hernando, Pedro Beneyto, Luis F Pajín, José Moreu-Burgos, Luis F. Lopez-Almodovar, Virginia Pascual-Tejerina, and Tomás Cantón
- Subjects
medicine.medical_specialty ,Cardiac Surgery ,Coronavirus disease 2019 (COVID-19) ,Estenosis aórtica ,Article ,Artificial Intelligence ,Risk Factors ,Humans ,Medicine ,In patient ,Cirugía cardiaca ,Severe stenosis ,Mortality ,Symptomatic aortic stenosis ,Intervencionismo estructural ,Pandemics ,business.industry ,Aortic stenosis ,General Engineering ,COVID-19 ,Aortic Valve Stenosis ,Structural heart intervention ,medicine.disease ,Cardiac surgery ,Stenosis ,Mortalidad ,Surgery ,Artificial intelligence ,business - Abstract
INTRODUCTION Untreated, severe, symptomatic aortic stenosis is associated with an ominous diagnosis without intervention. This study aims to determine the impact of the COVID-19 pandemic on the mortality of patients with severe stenosis during the first wave and compare it with the same period last year. METHODS All patients who went to the hospitals in a spanish region during the first wave, and in the same period of previous year, were analyzed using Artificial Intelligence-based software, evaluating the mortality of patients with severe aortic stenosis with and without COVID-19 during the pandemic and the pre-COVID era. Mortality of the three groups were compared. Regarding cardiac surgeries was a tendency to decrease (p=0.07) in patients without COVID-19 between the pandemic and the previous period was observed. A significant decrease of surgeries between patients with COVID-19 and without COVID-19 was shown. RESULTS Data showed 13.82% less admitted patients during the first wave. 1112 of them, had aortic stenosis and 5.48% were COVID-19 positive. Mortality was higher (p=0.01), in COVID-19 negative during the pandemic (4.37%) versus those in the pre-COVID19 era (2.57%); it was also in the COVID-19 positive group (11.47%), versus covid-19 negative (4.37%) during the first wave (p=0.01). CONCLUSIONS The study revealed a decrease in patients who went to the hospital and an excess of mortality in patients with severe AD without infection during the first wave, compared to the same period last year; and also, in COVID-19 positive patients versus COVID-19 negative.
- Published
- 2022
39. Implante valvular aórtico transcatéter (TAVI) e impacto en la sobrevida del paciente
- Author
-
Noemí Rocio Andrade Alban, Andrea Soledad Mera Viteri, and Mateo Josué Fantoni Añazco
- Subjects
implante valvular aórtico transcatéter ,estenosis aortica ,complicaciones ,tasa de sobrevida ,Medicine - Abstract
El implante valvular aórtico transcatéter, es un procedimiento cardiovascular de mínima invasión y una alternativa frente a la intervención convencional, en insuficiencia aórtica severa. En este trabajo se realiza una revisión de las complicaciones y la sobrevida, en pacientes sometidos a TAVI, frente a remplazo aórtico tradicional. Para ello se realizó una investigación documental con información entre los años 2010-2018. El implante valvular aórtico transcatéter debe efectuarse vía transfemoral o transapical, con una válvula Core o Sapien XT, según la necesidad del individuo, para evitar la regurgitación para valvular. Con este implante disminuyen las complicaciones y se remodela el ventrículo izquierdo; reduciendo la disnea y mejorando el pronóstico vida y la tasa de mortalidad en comparación con otros métodos.
- Published
- 2019
- Full Text
- View/download PDF
40. REEMPLAZO VALVULAR AÓRTICO POR CATETERISMO. ESTADO ACTUAL.
- Author
-
MENDIZ, OSCAR A. and GAMBOA, JOHN P.
- Abstract
Copyright of Medicina (Buenos Aires) is the property of Medicina (Buenos Aires) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
41. Exercise right heart catheterization predicts outcome in asymptomatic degenerative aortic stenosis.
- Author
-
Dobarro, David, Castrodeza-Calvo, Javier, Varela-Falcón, Luis, Varvaro, Gretel, Coya, María José, Martín, Carmen, Alonso, Carlos, Veras, Carlos, Tobar, Javier, Goncalves-Ramírez, Luis Renier, Vera, Lucía, López, Javier, and San Román, J. Alberto
- Abstract
Copyright of Revista Española de Cardiología (18855857) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
42. Implante valvular aórtico percutáneo
- Author
-
Camilo Arana, Antonio Dager, Bernardo Caicedo, Jaime Fonseca, Luis M. Benítez, Carlos Náder, Mauricio Zárate, Jairo Cadena, and Ángela Cucalón
- Subjects
Estenosis aórtica ,Insuficiencia aórtica ,Válvula ,Diseases of the circulatory (Cardiovascular) system ,RC666-701 - Abstract
El propósito de este consenso es presentar un resumen de los principales estudios que han evaluado el implante valvular aórtico percutáneo como terapia alternativa en pacientes con estenosis aórtica sintomática severa, quienes no pueden ser sometidos a cirugía por un alto riesgo quirúrgico, o que se consideran inoperables por el “equipo cardiológico”, condiciones consideradas como indicación para dispositivos “off label”. Luego se describen métodos diagnósticos para la estenosis aórtica y ayudas para saber con cuál equipo de cardiología estructural contar en la planificación, se revisa el procedimiento y finalmente se mencionan las complicaciones y los riesgos del mismo.
- Published
- 2017
- Full Text
- View/download PDF
43. Bicuspid Aortic Valve: Prolapse and Aortic Valve Calcification are Markers of Significant Valve Dysfunction and Major Cardiovascular Events at 5 Years.
- Author
-
CARRERO, MARÍA C., DÍAZ BABIO, GONZALO R., MASSON, GERARDO, CONSTANTIN, IVÁN, VERÓN, FACUNDO, MEZZADRA, MARÍA D. C., VERA JANAVEL, GUSTAVO L., and STUTZBACH, PABLO G
- Subjects
MITRAL valve ,AORTIC valve ,AORTIC valve insufficiency ,AORTIC valve transplantation ,AORTIC stenosis - Abstract
Copyright of Revista Argentina de Cardiología is the property of Sociedad Argentina de Cardiologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
44. Impact of a Heart Team in patients with aortic stenosis who are candidates for transcatheter aortic valve replacement
- Author
-
Trivi, Marcelo, Castro, María F., Trossero, Romina E., Cura, Fernando A., Piccinini, Fernando, Candiello, Alfonsina, Lamelas, Pablo M., Henquin, Ruth, Botto, Fernando, Ronderos, Ricardo, Trivi, Marcelo, Castro, María F., Trossero, Romina E., Cura, Fernando A., Piccinini, Fernando, Candiello, Alfonsina, Lamelas, Pablo M., Henquin, Ruth, Botto, Fernando, and Ronderos, Ricardo
- Abstract
As transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) became widespread, the need for a Heart Team (HT) arose to choose the best treatment. There are few reports regarding its usefulness. Objectives: To analyze treatment outcomes in patients with AS evaluated by a HT for 10 years. Methods: Consecutive enrollment of all patients with AS who were candidates for TAVI between January 2012 and July 2021 to choose the best treatment, including surgical aortic valve replacement (SAVR) and conservative medical management (CMM). Results: Out of 841 patients, 455 were assigned to TAVI (53%), 213 to SAVR (24%), and 183 to CMM (23%). The percentage assigned to TAVI has increased from 48% to 62% over time (p<0.05). Patients who underwent TAVI versus those who underwent SAVR were older (86 ± 7 vs. 83 ± 7 years), had a higher EUROSCORE II (6.2, 95% CI 5.7-6.6 vs. 5.6; 95% CI 4.4-6.5) and were frailer (1.62 ± 1 vs. 0.91 ± 1), in all cases p<0.01. Actuarial survival (95% CI) at 1 and 2 years was 88% (84-91%) and 82% (77-86%) for TAVI, 83% (76-88%) and 78% (70-84%) for SAVR, and 70% (60-87%) and 59% (48-68%) for CMM, respectively (p<0.001). Conclusions: For the first 10 years after a Heart Team was established for AS decision-making, approximately half of the patients were assigned to TAVI, and the rest were equally assigned in halves to either surgery or observation. Survival for patients who received interventions was similar at 2 years and higher than in those who did not., La difusión del reemplazo valvular aórtico percutáneo (TAVI) en la estenosis aórtica (EAo) generó la creación de un Heart Team (HT), para elegir el mejor tratamiento. Existen pocos reportes sobre su utilidad. Objetivos: analizar los resultados del tratamiento de los pacientes con EAo evaluados por un HT durante 10 años Material y métodos: Inclusión consecutiva de todos los pacientes con EAo candidatos a TAVI entre enero del 2012 y julio del 2021 para seleccionar el mejor tratamiento, incluyendo además Cirugía de Reemplazo Valvular Aórtico (CRVA) y Tratamiento Médico Conservador (TMC). Resultados: De 841 pacientes, se asignaron a: TAVI 455 (53%), CRVA 213 (24%) y TMC 183 (23%). El porcentaje asignado a TAVI aumentó con el tiempo de 48 a 62% (p<0,05). Los pacientes que fueron a TAVI, con respecto a los enviados a CRVA eran mayores (86±7 vs 83±7 años), con mayor EUROSCORE II (6,2, IC95% 5,7-6,6 vs 5,6, IC95% 4,4-6,5) y más frágiles (1,62±1 vs 0,91±1), en todos los casos p<0,01. La sobrevida actuarial (IC 95%) a 1 y a 2 años fue, para TAVI 88% (84-91%) y 82% (77-86%), para CRVA 83% (76-88%) y 78% (70-84%) y para TMC 70% (60-87%) y 59% (48-68%) respectivamente (p<0,001). Conclusiones: Durante los primeros 10 años de establecido un Heart Team para la toma de decisiones en EAo, se asignaron a TAVI aproximadamente la mitad y el resto se asignó por mitades a cirugía u observación. La sobrevida de los pacientes intervenidos fue similar a 2 años y mayor que la de los no intervenidos.
- Published
- 2023
45. Valvulopatía reumática: principios, fisiopatología y tratamiento
- Author
-
Rodríguez Sánchez, David, Coto Quirós, Amanda, Hernández Gaitán, Rolando, Rodríguez Sánchez, David, Coto Quirós, Amanda, and Hernández Gaitán, Rolando
- Abstract
Rheumatic heart disease is the main cause of mitral stenosis in developing countries. Recurrent infections secondary to Streptococcus pyogenes pharyngitis usually develop this disease. Its pathophysiology can be explained by two theories. Molecular mimicry consists in a molecule which is part of this bacteria presents antigenic similarity to the affected tissue. A new theory was developed recently, known as neoantigen theory, this suggests that S. pyogenes acquires access to the subendothelial collagen, inducing a autoimmune response against this tissue. Long-term valvular inflammation results in anatomic and functional abnormality of the affected valve. Surgical treatment for rheumatic valve disease has changed during the years. Initially the stenotic mitral valve was dilated manually using the surgeon ́s finger, a technique known as “closed” commissurotomy. Other treatment options nowadays consist in valve repair, percutaneous and open heart mitral valve replacement. Most of the patients present a great outcome after the adequate treatment and procedure., La valvulopatía reumática es la principal causa de estenosis mitral en países en vías de desarrollo. Esta enfermedad se manifiesta posterior a infecciones recurrentes por Streptococcus pyogenes. Existen dos teorías que explican esta condición. La primera se basa en el mimetismo molecular, esta consiste en que moléculas de este agente poseen similitud antigénica a los tejidos del ser afectado. La otra posible explicación más reciente consiste en la teoría del neo-antígeno, y sugiere que el estreptococo pyogenes adquiere acceso a la matriz del colágeno subendotelial, induciendo posteriormente una respuesta auto-inmune. La inflamación causada en el tejido valvular genera a largo plazo anormalidad tanto anatómica como funcional de esta. El tratamiento quirúrgico ha evolucionado mucho con los años, empezando con dilatación de la válvula mitral estenótica de forma manual con un dígito llamada también comisurotomía “cerrada” hasta la comisurotomía mitral percutánea. Con el tratamiento adecuado, el pronóstico posterior a los procedimientos mencionados anteriormente suele ser muy bueno.
- Published
- 2023
46. Implante percutáneo de válvula aórtica con Evolut PRO comparada con la SAPIEN 3: estudio comparativo aleatorizado
- Author
-
Elnaggar, Heba M., Schoels, Wolfgang, Mahmoud, Marwan S., Kishk, Yehia T., Kullmer, Matthias, Dia, Mohamad, Algowhary, Magdy, Elnaggar, Heba M., Schoels, Wolfgang, Mahmoud, Marwan S., Kishk, Yehia T., Kullmer, Matthias, Dia, Mohamad, and Algowhary, Magdy
- Abstract
Introduction and objectives: Advances made in transcatheter aortic valve implantation (TAVI) valvular technology have resulted in better outcomes and fewer complications compared with older generations. We studied the rate and determinants of paravalvular leak (PVL) using Evolut PRO vs SAPIEN 3 valves as well as other perioperative and in-hospital outcomes. Methods: A total of 110 consecutive patients with severe aortic stenosis scheduled for transfemoral TAVI were randomly selected to receive the SAPIEN 3 (N = 59) or the Evolut PRO valve (N = 51). Annular dimensions were determined by transesophageal echocardiography guided balloon sizing. The following postoperative and in-hospital endpoints were assessed: PVL, conduction defects, valve embolization, need for a second valve, annular rupture, stroke, vascular complications, acute kidney injury, and in-hospital mortality. We also studied the possible anatomical determinants of PVL. Results: There were no relevant baseline differences between the 2 groups regarding clinical and echocardiographic characteristics. In-hospital complications were comparable between both valves apart from a significantly higher rate of immediate postoperative PVL and at discharge (≥ grade II) between the Evolut PRO and the SAPIEN 3 valves (19.6% vs 6.8%) and (5.9% vs 1.7%), respectively. Of the anatomical variables described, the left ventricular outflow tract/ascending aorta angle, aortic angulation, and calcification had a significant impact on PVL in the Evolut PRO valves. The left ventricular outflow tract/ascending aorta angle revealed a negative correlation with implantation depth in the Evolut PRO valves but not in the SAPIEN 3 ones. Conclusions: Both valves demonstrated favorable comparable outcomes except for a significantly higher rate of PVL in patients implanted with Evolut PRO valves., Introducción y objetivos: Los avances en la tecnología de implante percutáneo de válvula aórtica (TAVI) han dado lugar a mejores resultados y menos complicaciones en comparación con las generaciones anteriores. Se estudió la incidencia y los determinantes de las fugas periprotésicas (FPP) con las válvulas Evolut PRO y SAPIEN 3, así como otros resultados periprocedimiento y hospitalarios. Métodos: Se seleccionó aleatoriamente a 110 pacientes consecutivos con estenosis aórtica grave programados para TAVI transfemoral para recibir una válvula SAPIEN 3 (n = 59) o una Evolut PRO (n = 51). Las dimensiones anulares se determinaron mediante el dimensionamiento del balón guiado por ecocardiografía transesofágica. Tras el procedimiento y durante la hospitalización se evaluaron los siguientes objetivos: FPV, defectos de conducción, embolización de la válvula, necesidad de una segunda válvula, rotura anular, accidente vascular cerebral, complicaciones vasculares, daño renal agudo y mortalidad intrahospitalaria. También se estudiaron los posibles determinantes anatómicos de la FPV. Resultados: No hubo diferencias basales relevantes entre los 2 grupos en cuanto a las características clínicas y ecocardiográficas. Las complicaciones intrahospitalarias fueron comparables entre ambos tipos de válvulas, excepto una incidencia significativamente mayor de FPV (de grado II o superior) inmediata tras el procedimiento y al alta con las válvulas Evolut PRO en comparación con las SAPIEN 3 (19,6 frente a 6,8% y 5,9 frente a 1,7%, respectivamente). De las variables anatómicas, el ángulo entre el tracto de salida del ventrículo izquierdo y la aorta ascendente, la angulación aórtica y la calcificación tuvieron un impacto significativo en la FPV en las válvulas Evolut PRO. El ángulo entre el tracto de salida del ventrículo izquierdo y la aorta ascendente tuvo una correlación negativa con la profundidad de implantación en las válvulas Evolut PRO, pero no en las válvulas SAPIEN 3. Conclusiones: Amb
- Published
- 2023
47. Coste-efectividad del implante percutáneo de válvula aórtica con SAPIEN 3 en pacientes con bajo riesgo de mortalidad quirúrgica en España
- Author
-
Vázquez Rodríguez, José Manuel, Pinar Bermúdez, Eduardo, Zamorano Gómez, José Luis, Moreu, José, Díaz Fernández, José Francisco, García del Blanco, Bruno, Sarmah, Archita, Candolfi, Pascal, Shore, Judith, Green, Michelle, Vázquez Rodríguez, José Manuel, Pinar Bermúdez, Eduardo, Zamorano Gómez, José Luis, Moreu, José, Díaz Fernández, José Francisco, García del Blanco, Bruno, Sarmah, Archita, Candolfi, Pascal, Shore, Judith, and Green, Michelle
- Abstract
Introduction and objectives: Transcatheter aortic valve implantation (TAVI) was first introduced in 2007 as an alternative to open heart surgery to treat patients with severe symptomatic aortic stenosis (sSAS) with various indication expansions since that date. Recently, the PARTNER 3 study (Placement of aortic transcatheter valve) demonstrated clinical benefits with TAVI with the SAPIEN 3 valve vs surgical aortic valve replacement (SAVR) in selected low surgical mortality risk patients. We reviewed data from the PARTNER 3 and economic data from Spain to assess the cost-effectiveness ratio of TAVI vs SAVR in patients with sSAS and low surgical mortality risk. Methods: A 2-stage model was used to estimate direct healthcare costs and health-related quality of life data regarding TAVI with the SAPIEN 3 valve and SAVR. Early adverse events associated with TAVI from the PARTNER 3 were fed into a Markov model that captured longer-term outcomes after TAVI or SAVR. Results: TAVI with SAPIEN 3 improved quality-adjusted life years per patient (+ 1.00) with an increase in costs vs SAVR (€6971 per patient). This meant an incremental cost-effectiveness ratio/quality-adjusted life year of €6952 per patient. The results were robust with TAVI with the SAPIEN 3 valve remaining cost-effective across several sensitivity analyses. Conclusions: TAVI with the SAPIEN 3 valve is cost effective compared to SAVR in patients with sSAS and low surgical mortality risk. These findings can inform policymakers to facilitate policy development in Spain on intervention selection in this patient population., Introducción y objetivos: El implante percutáneo de válvula aórtica (TAVI) se introdujo en 2007 como una alternativa a la cirugía a corazón abierto para tratar a pacientes con estenosis aórtica grave sintomática, y desde entonces han aumentado las indicaciones autorizadas. Recientemente, el Placement of Aortic Transcatheter Valve Study (PARTNER) 3 ha demostrado beneficios clínicos con el TAVI con la válvula SAPIEN 3 frente al reemplazo quirúrgico de válvula aórtica (RVAo) en pacientes seleccionados con bajo riesgo de mortalidad quirúrgica. Utilizando los datos del PARTNER 3 junto con datos económicos de España, se evaluó la relación coste-efectividad del TAVI en comparación con el RVAo en pacientes con estenosis aórtica grave sintomática con bajo riesgo de mortalidad quirúrgica. Métodos: Se utilizó un modelo en dos etapas para estimar los costes directos sanitarios y los datos de calidad de vida relacionadas con la salud para TAVI con la válvula SAPIEN 3 y RVAo. Los eventos adversos tempranos relacionados con TAVI del PARTNER 3 se incluyeron en un modelo de Markov, que capturó los resultados a más largo plazo tras TAVI o RVAo. Resultados: El TAVI con SAPIEN 3 mejoró los años de vida ajustados por calidad por paciente (+1,00), con un aumento en el coste frente al RVAo de 6.971 € por paciente. Esto representó una ratio coste-efectividad incremental por año de vida ganado ajustado por calidad de 6.952 € por paciente. Los resultados fueron robustos en los diversos análisis de sensibilidad realizados, en los que el TAVI con SAPIEN 3 se mantiene como una opción coste-efectiva. Conclusiones: El TAVI con SAPIEN 3 es coste-efectivo en comparación con el RVAo en pacientes con estenosis aórtica grave sintomática con bajo riesgo de mortalidad quirúrgica. Estos resultados pueden informar a los decisores políticos en España para facilitar el desarrollo de políticas sobre la selección de opciones terapéuticas en esta población de pacientes.
- Published
- 2023
48. Aurícula derecha: un buen aliado en la estimulación ventricular izquierda durante el implante percutáneo de válvula aórtica
- Author
-
Abril Molina, Alba, Quero, Monica Fernandez, Cardenal Piris, Rosa, Guisado Rasco, Agustín, Díaz Fernández, José, Delgado, Rocío Rodríguez, Peña Mellado, Jesús, Gil-Ortega, Manuel Villa, Abril Molina, Alba, Quero, Monica Fernandez, Cardenal Piris, Rosa, Guisado Rasco, Agustín, Díaz Fernández, José, Delgado, Rocío Rodríguez, Peña Mellado, Jesús, and Gil-Ortega, Manuel Villa
- Abstract
Introduction and objectives: Rapid ventricular pacing reduces cardiac output by providing stability during transcatheter aortic valve implantation (TAVI). Our objective is to assess the efficacy and safety profile of left ventricular pacing through the high-support guidewire used for implantation and a guidewire located in the right atrium (RA) functioning as an anode. Methods: Left ventricular pacing is performed by connecting the external end of a Safari2 pre-shaped guidewire located in the left ventricle to the cathode of a temporary pacemaker, and the anode to the body of an Emerald guidewire inserted into the RA using a diagnostic Judkins Right catheter (via ultrasound-guided femoral venous access). Pacemaker was programmed with maximum output (20 V) and null sensitivity. Results: A total of 62 selected patients (median 79.4 ± 6.5 years old) underwent transfemoral TAVI using the pacing technique described (25 patients the SAPIEN 3 Ultra; 13 the Navitor, 9 the ACURATE neo2, 14 the Evolut PRO+, and 1 patient the Myvalve). Procedure was successful in all cases (there was 1 capture failure due to pacemaker programming). Two patients required a temporary and permanent pacemaker due to high-grade atrioventricular block. No vascular complications from venous access were documented, not even from the RA guidewire. Procedural time did not increase significantly, and the median length of stay after implantation was 2 days. Conclusions: In our series, left ventricular pacing using the RA-positioned wire as the anode proved to be effective and safe without increasing procedural time significantly. This procedure also provides the advantage of being able to use the central venous access for possible emergency temporary pacemaker implantation., Introducción y objetivos: La estimulación ventricular rápida reduce el gasto cardiaco, proporcionando estabilidad durante el implante percutáneo de válvula aórtica (TAVI). Nuestro objetivo fue evaluar la eficacia y la seguridad de la estimulación ventricular izquierda a través de la guía de alto soporte utilizada para el implante y una guía situada en la aurícula derecha (AD) que actúa como ánodo. Métodos: La estimulación ventricular izquierda se realiza conectando el extremo externo de una guía Safari2 preformada situada en el ventrículo izquierdo al cátodo de un marcapasos temporal, y el ánodo al cuerpo de una guía Emerald insertada en la aurícula mediante un catéter Judkins Right diagnóstico a través de un acceso venoso femoral (punción ecoguiada). El marcapasos se programa con salida máxima (20 V) y sensibilidad anulada. Resultados: Se realizó TAVI transfemoral a 62 pacientes seleccionados (mediana de edad: 79,4 ± 6,5 años) utilizando la técnica de estimulación descrita (25 SAPIEN 3 Ultra, 13 Navitor, 9 ACURATE neo2, 14 Evolut-PRO+ y 1 Myvalve), con éxito en todos los casos (hubo 1 fallo de captura atribuido a la programación del generador del marcapasos). Dos pacientes necesitaron marcapasos transitorio y definitivo posterior por bloqueo auriculoventricular completo durante el procedimiento. No se documentaron complicaciones vasculares derivadas del acceso venoso ni del posicionamiento de la guía en la AD. No aumentaron de manera significativa el tiempo del procedimiento ni la fluoroscopia. La mediana de estancia hospitalaria tras el implante fue de 2 días. Conclusiones: En nuestra serie, la estimulación ventricular izquierda utilizando como ánodo la guía situada en la AD ha demostrado ser una técnica eficaz y segura, sin aumentar significativamente el tiempo de procedimiento, y además aporta la ventaja de disponer de acceso venoso central para un posible marcapasos transitorio urgente.
- Published
- 2023
49. Determinantes pronósticos en pacientes sometidos a tratamiento percutáneo de la estenosis aórtica grave. Influencia de parámetros antropométricos, nutricionales e inflamatorios
- Author
-
González Juanatey, José Ramón, López Otero, Diego, Universidade de Santiago de Compostela. Escola de Doutoramento Internacional (EDIUS), Universidade de Santiago de Compostela. Programa de Doutoramento en Investigación Clínica en Medicina, González Ferreiro, Rocío, González Juanatey, José Ramón, López Otero, Diego, Universidade de Santiago de Compostela. Escola de Doutoramento Internacional (EDIUS), Universidade de Santiago de Compostela. Programa de Doutoramento en Investigación Clínica en Medicina, and González Ferreiro, Rocío
- Abstract
Una proporción importante de pacientes con estenosis aórtica grave sintomática que se someten a reemplazo percutáneo no obtienen la mejoría esperada del procedimiento. Analizamos diferentes factores no clásicos que podrían afectar a los resultados del tratamiento percutáneo de la estenosis aórtica: el índice de masa corporal, el riesgo de malnutrición y el marcador de inflamación hsPCR. Los hallazgos de los estudios realizados contribuyen a un mejor conocimiento de estos factores, que influyen de forma significativa en el resultado del tratamiento percutáneo de la estenosis aórtica grave. Estos resultados nos permitirían optimizar la estratificación de riesgo de estos pacientes dentro de una valoración integral y potencialmente, desarrollar intervenciones que pudiesen mejorar su estado general antes de la intervención.
- Published
- 2023
50. Prótesis sin sutura Perceval S en la cirugía valvular aórtica de alto riesgo. Una herramienta fundamental para el cirujano
- Author
-
Elisabet Berastegui García, Maria Luisa Camara Rosell, Paula Albaladejo Da Silva, Sara Badia Gamarra, Luis Delgado Ramis, Claudio Fernandez Gallego, Elena Ferrer Sistach, Ignasi Julia Almill, Jorge Lopez Ayerbe, Bernat Romero Ferrer, and Xavier Ruyra Baliarda
- Subjects
Estenosis aórtica ,Sin sutura ,Pacientes de riesgo medio-alto ,Medicine ,Surgery ,RD1-811 - Abstract
Objetivo: La introducción de las nuevas prótesis aórticas sin sutura ha supuesto una alternativa para el tratamiento quirúrgico de la estenosis aórtica severa. Presentamos la experiencia de nuestro grupo tras el inicio de un programa con prótesis Perceval S (Livanova, Saluggia, Italia). Pacientes y métodos: Entre marzo de 2012 y octubre de 2016 se implantó la prótesis Perceval S en 262 pacientes (edad media: 77,97 ± 6,12 años; 56,49% de mujeres). En 176 casos (67,18%) se realizó sustitución valvular aórtica aislada, con miniesternotomía en un 36,9%. El seguimiento clínico y ecocardiográfico se realizó al alta, a los 6 meses y anualmente. Resultados: La mortalidad esperada fue del 14,19 ± 1,31% (Euroscore log I) y del 7,47 ± 1,11% (Euroscore log II). La mortalidad observada fue del 4,23%. Hubo complicaciones neurológicas en 2 pacientes (0,94%), y fuga periprotésica moderada al alta en 2 pacientes. El seguimiento medio fue de 26 ± 6,2 meses. La mortalidad en el seguimiento fue del 1,9% (4 pacientes); estabilidad de las fugas grado II en el seguimiento; gradiente medio de 10,2 mmHg. El 95% de los pacientes se encontraban en grado funcional I-II. Conclusiones: El inicio de un programa de implante de prótesis sin sutura Perceval S ha permitido intervenir a pacientes de alto riesgo con buenos resultados y baja morbilidad. La prótesis ha demostrado ser muy versátil, tener un excelente comportamiento hemodinámico y favorecer la cirugía de mínimo acceso.
- Published
- 2017
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.