29 results on '"Eggermont F"'
Search Results
2. Functional biomechanical performance of a novel anatomically shaped polycarbonate urethane total meniscus replacement
- Author
-
Vrancken, A. C. T., Eggermont, F., van Tienen, T. G., Hannink, G., Buma, P., Janssen, D., and Verdonschot, N.
- Published
- 2016
- Full Text
- View/download PDF
3. Effect of different CT scanners and settings on femoral failure loads calculated by finite element models
- Author
-
Eggermont, F., Derikx, L.C., Free, J., Leeuwen, R. van, Linden, Y.M. van der, Verdonschot, N., and Tanck, E.
- Subjects
RISK ,finite element model ,VALUES ,UT-Hybrid-D ,PREDICTIONS ,CT scanner ,METASTATIC LESIONS ,RANDOMIZED-TRIAL ,FRACTURE ,Imaging ,Reconstructive and regenerative medicine Radboud Institute for Health Sciences [Radboudumc 10] ,All institutes and research themes of the Radboud University Medical Center ,STRENGTH ,femur ,failure load ,CT protocol ,PHANTOM ,Research Articles ,Rare cancers Radboud Institute for Health Sciences [Radboudumc 9] ,Research Article - Abstract
In a multi‐center patient study, using different CT scanners, CT‐based finite element (FE) models are utilized to calculate failure loads of femora with metastases. Previous studies showed that using different CT scanners can result in different outcomes. This study aims to quantify the effects of (i) different CT scanners; (ii) different CT protocols with variations in slice thickness, field of view (FOV), and reconstruction kernel; and (iii) air between calibration phantom and patient, on Hounsfield Units (HU), bone mineral density (BMD), and FE failure load. Six cadaveric femora were scanned on four CT scanners. Scans were made with multiple CT protocols and with or without an air gap between the body model and calibration phantom. HU and calibrated BMD were determined in cortical and trabecular regions of interest. Non‐linear isotropic FE models were constructed to calculate failure load. Mean differences between CT scanners varied up to 7% in cortical HU, 6% in trabecular HU, 6% in cortical BMD, 12% in trabecular BMD, and 17% in failure load. Changes in slice thickness and FOV had little effect (≤4%), while reconstruction kernels had a larger effect on HU (16%), BMD (17%), and failure load (9%). Air between the body model and calibration phantom slightly decreased the HU, BMD, and failure loads (≤8%). In conclusion, this study showed that quantitative analysis of CT images acquired with different CT scanners, and particularly reconstruction kernels, can induce relatively large differences in HU, BMD, and failure loads. Additionally, if possible, air artifacts should be avoided. © 2018 Orthopaedic Research Society. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:2288–2295, 2018.
- Published
- 2018
4. Can patient-specific finite element models better predict fractures in metastatic bone disease than experienced clinicians?
- Author
-
Eggermont, F., Derikx, L.C., Verdonschot, N., Geest, I.C.M. van der, Jong, M.A.A. de, Snyers, A., Linden, Y.M. van der, and Tanck, E.
- Subjects
Reconstructive and regenerative medicine Radboud Institute for Health Sciences [Radboudumc 10] ,Metastatic bone disease ,Femur ,Fracture prediction ,Women's cancers Radboud Institute for Health Sciences [Radboudumc 17] ,Finite element modelling - Abstract
Objectives In this prospective cohort study, we investigated whether patient-specific finite element (FE) models can identify patients at risk of a pathological femoral fracture resulting from metastatic bone disease, and compared these FE predictions with clinical assessments by experienced clinicians.Methods A total of 39 patients with non-fractured femoral metastatic lesions who were irradiated for pain were included from three radiotherapy institutes. During follow-up, nine pathological fractures occurred in seven patients. Quantitative CT-based FE models were generated for all patients. Femoral failure load was calculated and compared between the fractured and non-fractured femurs. Due to inter-scanner differences, patients were analyzed separatelyfor the three institutes. In addition, the FE-based predictions were compared with fracture risk assessments by experienced clinicians.Results In institute 1, median failure load was significantly lower for patients who sustained a fracture than for patients with no fractures. In institutes 2 and 3, the number of patients with a fracture was too low to make a clear distinction. Fracture locations were well predicted by the FE model when compared with post-fracture radiographs. The FE model was more accurate in identifying patients with a high fracture risk compared with experienced clinicians, with a sensitivity of 89% versus 0% to 33% for clinical assessments. Specificity was 79% for the FE models versus 84% to 95% for clinical assessments.Conclusion FE models can be a valuable tool to improve clinical fracture risk predictions in metastatic bone disease. Future work in a larger patient population should confirm the higher predictive power of FE models compared with current clinical guidelines.
- Published
- 2018
5. Effect of different ct scanners and settings on bone ct values for finite element predicted femoral failure load
- Author
-
Eggermont, F., Derikx, L., Free, J., van der Linden, Y., Verdonschot, Nicolaas Jacobus Joseph, and Tanck, E.
- Subjects
METIS-320305 - Published
- 2016
6. BIOFRAG \u2013 a new database for analyzing BIOdiversity responses to forest FRAGmentation
- Author
-
Pfeifer, M and V. Lefebvre, T. A. Gardner, V. Arroyo-Rodriguez, L. Baeten, C. Banks-Leite, J. Barlow, M. G. Betts, J. Brunet, A. Cerezo, L. M. Cisneros, S. Collard, N. D'Cruze, C. da Silva Motta, S. Duguay, H. Eggermont, F. Eigenbrod, A. S. Hadley, T. R. Hanson, J. E. Hawes, T. Heartsill Scalley, B. T. Klingbeil, A. Kolb, U. Kormann, S. Kumar, T. Lachat, P. Lakeman Fraser, V. Lantschner, W. F. Laurance, I. R. Leal, L. Lens, C. J. Marsh, G. F. Medina-Rangel, S. Melles, D. Mezger, J. A. Oldekop, et al.
- Published
- 2014
7. Biomechanical performance of a polycarbonate urethane total meniscus replacement
- Author
-
Vrancken, A.C.T., Eggermont, F., van Tienen, T.G., Janssen, D., Verdonschot, Nicolaas Jacobus Joseph, and Buma, Pieter
- Subjects
METIS-308692 - Published
- 2014
8. PO-0778: Limited short-term effect of radiotherapy on bone density in metastatic femoral bone
- Author
-
Eggermont, F., primary, Derikx, L.C., additional, Verdonschot, N., additional, Hannink, G., additional, Kaatee, R.S.J.P., additional, Tanck, E., additional, and Van der Linden, Y.M., additional
- Published
- 2016
- Full Text
- View/download PDF
9. Inleiding tot het recht: 10de uitgave
- Author
-
De Becker, A., Debièvre, J., Eggermont, F., Gorus, J., and AIAS (FdR)
- Published
- 2013
10. The assisted 6-minute cycling test to assess endurance in children with a neuromuscular disorder
- Author
-
Jansen, M., Jong, M. de, Coes, H.M., Eggermont, F., Alfen, N. van, and de Groot, I.J.
- Subjects
Human Reproduction [NCEBP 12] ,DCN MP - Plasticity and memory ,Human Movement & Fatigue DCN PAC - Perception action and control [NCEBP 10] - Abstract
Item does not contain fulltext Introduction: For late- or non-ambulant children with a neuromuscular disorder no suitable endurance tests are currently available. We developed the assisted 6-minute cycling test (A6MCT) for the legs and arms and investigated its psychometric properties in healthy boys and boys with Duchenne muscular dystrophy (DMD). Methods: Ninety-nine healthy boys and 30 boys with DMD (12 wheelchair-dependent) performed the A6MCT. Seventy healthy boys also performed the 6-minute walk test (6MWT), and 23 boys performed the A6MCT twice within 2 weeks. Boys with DMD also performed the Motor Function Measure (MFM). Results: The A6MCT was feasible for >90% of all boys. Boys with DMD achieved fewer cycling revolutions than controls. The A6MCT was positively correlated with the 6MWT and was reproducible in healthy boys, and it correlated with disease severity in boys with DMD. Conclusions: The A6MCT is a promising outcome measure for the follow-up of non-ambulant children with a neuromuscular disorder. Muscle Nerve 46: 520-530, 2012.
- Published
- 2012
11. Functional biomechanical performance of a novel anatomically shaped polycarbonate urethane total meniscus replacement
- Author
-
Vrancken, A.C.T., Eggermont, F., van Tienen, T.G., Hannink, G., Buma, P., Janssen, D., Verdonschot, N., Vrancken, A.C.T., Eggermont, F., van Tienen, T.G., Hannink, G., Buma, P., Janssen, D., and Verdonschot, N.
- Abstract
PURPOSE: To evaluate the functional biomechanical performance of a novel anatomically shaped, polycarbonate urethane total meniscus implant.METHODS: Five human cadaveric knees were flexed between 0° and 90° under compressive loads mimicking a squat movement. Anteroposterior (AP) laxity tests were performed in 30° and 90° flexion. Meniscal kinematics and knee laxity were quantified using roentgen stereophotogrammetric analysis. Tibial cartilage contact mechanics were determined in 90° flexion. Measurements were repeated for the native medial meniscus, the implant, after total medial meniscectomy and allograft transplantation.RESULTS: The implant and allograft displayed increased posterior and medial displacements compared to the native meniscus, yet no differences were found between the implant and allograft. Meniscal condition did not affect rotational laxity. Compared to the native joint, AP laxity for the implant was increased in 30° flexion, but not in 90°. The implant reduced the mean contact pressure compared to meniscectomy but could not restore contact pressures to native meniscus levels. Compared to the native meniscus, the implant significantly increased the peak pressure, while the contact area was reduced. Contact mechanics of the implant and allograft were never statistically different.CONCLUSIONS: Biomechanical performance was similar for the implant and allograft. However, both meniscal replacements could not restore outcomes to native meniscus levels or sufficiently improve outcomes after meniscectomy. This was presumably caused by the mobility allowed by the suture-only horn fixation. The similarity of implant and allograft performance suggests that the novel implant has the biomechanical potential to serve as an alternative to meniscal allograft transplantation.
- Published
- 2015
12. Functional biomechanical performance of a novel anatomically shaped polycarbonate urethane total meniscus replacement
- Author
-
Vrancken, A. C. T., primary, Eggermont, F., additional, van Tienen, T. G., additional, Hannink, G., additional, Buma, P., additional, Janssen, D., additional, and Verdonschot, N., additional
- Published
- 2015
- Full Text
- View/download PDF
13. Praktijkboek rechtsmethodologie
- Author
-
Schreurs, W, Eggermont, F, Smis, S, Paepe, P, Gutwirth, SL, and Erasmus School of Law
- Published
- 2008
14. Step performance in persons with rheumatoid arthritis: a case-control study.
- Author
-
Smulders, E., Lankveld, W. van, Eggermont, F., Duysens, J.E.J., Weerdesteijn, V.G.M., Smulders, E., Lankveld, W. van, Eggermont, F., Duysens, J.E.J., and Weerdesteijn, V.G.M.
- Abstract
01 oktober 2011, Item does not contain fulltext, OBJECTIVE: To investigate factors that could lead to falls in patients with rheumatoid arthritis (RA). DESIGN: Case-control study. SETTING: Hospital. PARTICIPANTS: Patients with RA (n=15) and age- and sex-matched controls (n=15; mean +/- SD age, 60.5 +/- 7.1y). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Performance of participants on a step task. Furthermore, manual performance was assessed, as well as questionnaires for balance confidence, fear of falling, and activity level. RESULTS: Patients with RA showed nonsignificantly increased RTs (time to anticipatory postural adjustment and foot lift) and significantly increased movement times (MTs). Push-off force and step velocity were significantly lower in patients with RA. During a manual task, delayed RTs and MTs were seen. Moreover, lower levels of balance confidence and more fear of falling were reported in patients with RA. There were no differences in activity levels. CONCLUSIONS: When performing a quick step, patients with RA show delayed MT and step velocity and decreased push off. Because quick stepping often is used to avoid falls, the increase in step execution time might have undesirable consequences. Furthermore, patients with RA have lower balance confidence and more fear of falling than healthy controls; these factors also contribute to higher fall risk.
- Published
- 2011
15. INTRAVENTRICULAR AND OR INTRALUMBAR TREATMENT OF PURULENT MENINGITIS IN INFANTS
- Author
-
Corbeel, L, primary, Boeck, K De, additional, Logghe, N, additional, Eggermont, F, additional, Eeckels, R, additional, Casaer, P, additional, Vandepitte, J, additional, and Verbist, L, additional
- Published
- 1980
- Full Text
- View/download PDF
16. Using a statistical shape model to estimate the knee landmarks for aligning femurs for femoral finite element models.
- Author
-
Eggermont F, Mathijssen E, Bakker M, and Tanck E
- Subjects
- Humans, Female, Male, Middle Aged, Aged, Models, Statistical, Tomography, X-Ray Computed, Knee diagnostic imaging, Knee anatomy & histology, Models, Anatomic, Finite Element Analysis, Femur anatomy & histology, Femur diagnostic imaging, Knee Joint anatomy & histology, Knee Joint diagnostic imaging, Knee Joint physiology
- Abstract
Background and Objective: The BOne Strength (BOS) score is a CT-based tool to assess fracture risk for patients with femoral bone metastases using finite element (FE) models. Until now, the knee joint center (KJC) and centers of the condyles (CoCs) were needed to create the FE model, hence BOS scores of incompletely scanned femurs could not be calculated. In this study, a statistical shape model (SSM) was used to align FE models of femurs with a removed knee anatomy. The aim was to determine the effect of using an SSM with different proximal femur fractions on KJC and CoC locations, and on the BOS score., Methods: QCT scans of 117 femurs were used to generate patient-specific FE models of the proximal femur. These models were aligned using the knee joint center (KJC), center of condyles (CoC) and femoral head center. The femurs were artificially shortened by removing 30 %, 50 % or 70 % of the femur. A recently developed SSM was used to reconstruct the distal femur. For each of the femur fractions, the difference between the original and SSM-reconstructed KJC and CoC were determined and the BOS scores were calculated., Results: Although the individual differences between the original and SSM-reconstructed KJC and CoC location could be large, the effect on the individual BOS scores was limited. The SSM-reconstructed BOS scores were highly correlated to the original BOS scores., Conclusion: Using SSM to align femurs with a removed knee anatomy resulted in varying estimation of knee anatomy between patients but relatively accurate BOS scores., Competing Interests: Declaration of competing interest None declared., (Copyright © 2024. Published by Elsevier B.V.)
- Published
- 2024
- Full Text
- View/download PDF
17. The effect of deep learning-based lesion segmentation on failure load calculations of metastatic femurs using finite element analysis.
- Author
-
Ataei A, Eggermont F, Verdonschot N, Lessmann N, and Tanck E
- Subjects
- Humans, Finite Element Analysis, Calcium, Femur diagnostic imaging, Deep Learning, Bone Neoplasms diagnostic imaging, Bone Neoplasms secondary
- Abstract
Bone ranks as the third most frequent tissue affected by cancer metastases, following the lung and liver. Bone metastases are often painful and may result in pathological fracture, which is a major cause of morbidity and mortality in cancer patients. To quantify fracture risk, finite element (FE) analysis has shown to be a promising tool, but metastatic lesions are typically not specifically segmented and therefore their mechanical properties may not be represented adequately. Deep learning methods potentially provide the opportunity to automatically segment these lesions and change the mechanical properties more adequately. In this study, our primary focus was to gain insight into the performance of an automatic segmentation algorithm for femoral metastatic lesions using deep learning methods and the subsequent effects on FE outcomes. The aims were to determine the similarity between manual segmentation and automatic segmentation; the differences in predicted failure load between FE models with automatically segmented osteolytic and mixed lesions and the models with CT-based lesion values (the gold standard); and the effect on the BOne Strength (BOS) score (failure load adjusted for body weight) and subsequent fracture risk assessments. From two patient cohorts, a total number of 50 femurs with osteolytic and mixed metastatic lesions were included in this study. The femurs were segmented from CT images and transferred into FE meshes. The material behavior was implemented as non-linear isotropic. These FE models were considered as gold standard (Finite Element no Segmented Lesion: FE-no-SL), whereby the local calcium equivalent density of both femur and metastatic lesion was extracted from CT-values. Lesions in the femur were manually segmented by two biomechanical experts after which final lesion segmentation for each femur was obtained based on consensus of opinions between two observers. Subsequently, a self-configuring variant of the popular deep learning model U-Net known as nnU-Net was used to automatically segment metastatic lesions within the femur. For these models with segmented lesions (Finite Element with Segmented Lesion: FE-with-SL), the calcium equivalent density within the metastatic lesions was set to zero after being segmented by the neural network, simulating absence of load-bearing capacity of these lesions. The models (either with or without automatically segmented lesions) were loaded incrementally in axial direction until failure was simulated. Dice coefficient was used to evaluate the similarity of the manual and automatic segmentation. Mean calcium equivalent density values within the automatically segmented lesions were calculated. Failure loads and patterns were determined. Furthermore, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for both groups by comparing the predictions to the occurrence or absence of actual fracture within the patient cohorts. The automatic segmentation algorithm performed in a none-robust manner. Dice coefficients describing the similarity between consented manual and automatic segmentations were relatively low (mean 0.45 ± standard deviation 0.33, median 0.54). Failure load difference between the FE-no-SL and FE-with-SL groups varied from 0 % to 48 % (mean 6.6 %). Correlation analysis of failure loads between the two groups showed a strong relationship (R
2 > 0.9). From the 50 cases, four cases showed clear deviations for which models with automatic lesion segmentation (FE-with-SL) showed considerably lower failure loads. In the whole database including osteolytic and mixed lesions, sensitivity and NPV remained the same, but specificity and PPV decreased from 94 % to 83 %, and from 78 % to 54 % respectively from FE-no-SL to FE-with-SL. This study indicates that the nnU-Net yielded none-robust outcomes in femoral lesion segmentation and that other segmentation algorithms should be considered. However, the difference in failure pattern and failure load between FE models with automatically segmented osteolytic and mixed lesions were relatively small in most cases with a few exceptions. On the other hand, the accuracy of fracture risk assessment using the BOS score was lower compared to the FE-no-SL. In conclusion, this study showed that automatic lesion segmentation is a none-solved issue and therefore, quantifying lesion characteristics and the subsequent effect on the fracture risk using deep learning will remain challenging., Competing Interests: Declaration of competing interest None., (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF
18. The application of an isotropic crushable foam model to predict the femoral fracture risk.
- Author
-
Soltanihafshejani N, Peroni F, Toniutti S, Bitter T, Tanck E, Eggermont F, Verdonschot N, and Janssen D
- Subjects
- Humans, Bone Density physiology, Bone and Bones, Biomechanical Phenomena, Femur diagnostic imaging, Femur physiology, Femoral Fractures
- Abstract
For biomechanical simulations of orthopaedic interventions, it is imperative to implement a material model that can realistically reproduce the nonlinear behavior of the bone structure. However, a proper material model that adequately combines the trabecular and cortical bone response is not yet widely identified. The current paper aims to investigate the possibility of using an isotropic crushable foam (ICF) model dependent on local bone mineral density (BMD) for simulating the femoral fracture risk. The elastoplastic properties of fifty-nine human femoral trabecular cadaveric bone samples were determined and combined with existing cortical bone properties to characterize two forms of the ICF model, a continuous and discontinuous model. Subsequently, the appropriateness of this combined material model was evaluated by simulating femoral fracture experiments, and a comparison with earlier published results of a softening Von-Mises (sVM) material model was made. The obtained mechanical properties of the trabecular bone specimens were comparable to previous findings. Furthermore, the ultimate failure load predicted by the simulations of femoral fractures was on average 79% and 90% for the continuous and discontinuous forms of the ICF model and 82% of the experimental value for the sVM material model. Also, the fracture locations predicted by ICF models were comparable to the experiments. In conclusion, a nonlinear material model dependent on BMD was characterized for human femoral bone. Our findings indicate that the ICF model could predict the femoral bone strength and reproduce the variable fracture locations in the experiments., Competing Interests: The authors have declared that no competing interests exist., (Copyright: © 2023 Soltanihafshejani et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)
- Published
- 2023
- Full Text
- View/download PDF
19. A Patient-Specific Fracture Risk Assessment Tool for Femoral Bone Metastases: Using the Bone Strength (BOS) Score in Clinical Practice.
- Author
-
Eggermont F, van der Linden Y, Verdonschot N, Dierselhuis E, Ligthert S, Bitter T, Westhoff P, and Tanck E
- Abstract
Patients with femoral metastases are at risk of fracturing bones. It is important to prevent fractures in order to maintain mobility and quality of life. The BOne Strength (BOS) score is based on a computed tomography (CT)-based patient-specific finite element (FE) computer model that objectively calculates bone strength. In this pilot study, the added clinical value of the BOS score towards treatment-related decision making was assessed. In December 2019, the BOS score was implemented in four radiotherapy centers. The BOS scores and fracture risks of individual patients were calculated and returned to the physician to assist in treatment decisions. The physicians filled out a questionnaire, which was qualitatively analyzed. A follow-up to identify fractures and/or death was performed after six months. Until June 2021, 42 BOS scores were delivered (20 high, 9 moderate, and 13 low fracture risk). In 48%, the BOS score led to an adaptation of treatment plans. Physicians indicated that the BOS score provided objective insight into fracture risk, was reassuring for physicians and patients, and improved multidisciplinary discussions and shared decision making. In conclusion, the BOS score is an objective tool to assess fracture risk in femoral bone metastases and aids physicians and patients in making a more informed decision regarding the most appropriate treatment.
- Published
- 2022
- Full Text
- View/download PDF
20. The effect of variations in CT scan protocol on femoral finite element failure load assessment using phantomless calibration.
- Author
-
Ataei A, Eikhout J, van Leeuwen RGH, Tanck E, and Eggermont F
- Subjects
- Calibration, Finite Element Analysis, Humans, Lower Extremity, Phantoms, Imaging, Tomography, X-Ray Computed methods, Bone Density, Femur diagnostic imaging
- Abstract
Recently, it was shown that fracture risk assessment in patients with femoral bone metastases using Finite Element (FE) modeling can be performed using a calibration phantom or air-fat-muscle calibration and that non-patient-specific calibration was less favorable. The purpose of this study was to investigate if phantomless calibration can be used instead of phantom calibration when different CT protocols are used. Differences in effect of CT protocols on Hounsfield units (HU), calculated bone mineral density (BMD) and FE failure loads between phantom and two methods of phantomless calibrations were studied. Five human cadaver lower limbs were scanned atop a calibration phantom according to a standard scanning protocol and seven additional commonly deviating protocols including current, peak kilovoltage (kVp), slice thickness, rotation time, field of view, reconstruction kernel, and reconstruction algorithm. The HUs of the scans were calibrated to BMD (in mg/cm3) using the calibration phantom as well as using air-fat-muscle and non-patient-specific calibration, resulting in three models for each scan. FE models were created, and failure loads were calculated by simulating an axial load on the femur. HU, calculated BMD and failure load of all protocols were compared between the three calibration methods. The different protocols showed little variation in HU, BMD and failure load. However, compared to phantom calibration, changing the kVp resulted in a relatively large decrease of approximately 10% in mean HU and BMD of the trabecular and cortical region of interest (ROI), resulting in a 13.8% and 13.4% lower failure load when air-fat-muscle and non-patient-specific calibrations were used, respectively. In conclusion, while we observed significant correlations between air-fat-muscle calibration and phantom calibration as well as between non-patient-specific calibration and phantom calibration, our sample size was too small to prove that either of these calibration approaches was superior. Further studies are necessary to test whether air-fat-muscle or non-patient-specific calibration could replace phantom calibration in case of different scanning protocols., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2022
- Full Text
- View/download PDF
21. What is it like to organize a large-scale educational event for fellow students? A qualitative exploration of student participation in curriculum design.
- Author
-
Olthuis G, Eggermont F, Schouwenberg B, Oerlemans A, and Tanck E
- Subjects
- Curriculum, Faculty, Humans, Problem-Based Learning, Education, Medical, Undergraduate, Students, Medical
- Abstract
Background: Although students are increasingly involved in curriculum design, empirical research on practices of actual student participation is sparse. The purpose of this study is to explore the experiences of students who collaborated in the organizing committee of a large-scale educational event, the Radboud Student Conference (RSC), for fellow students., Methods: We conducted three focus group interviews, in which 17 (bio) medical students of three different organizing teams shared their experiences regarding the organization of the large-scale teaching event. The analysis was conducted using thematic content analysis, in which the codes and codebook were constructed on the basis of the data., Results: The following four themes were derived from the data. 1) Collaboration, which concentrated on fellow students, teachers who were involved as supervisors, and persons outside the organizing team such as caterers, educational support office members, lecturers, physicians and researchers. 2) Planning and division of labor, with students experiencing a mutual dependence and noticing a gradual improvement of their skills. 3) Freedom implies responsibility, which indicted that students experienced a significant freedom to develop the RSC week, but at the same time felt the responsibility to deliver a successful final week of the academic year. 4) Personal development, where students mentioned the opportunity to practice skills that differed from standard (bio) medical electives., Conclusions: We conclude that (bio) medical students are capable of bearing the responsibility to organize a large-scale educational event. Organizing the RSC was an educational experience in the form of cooperative and experiential learning which contributed to students' personal development. Organizing the event gave students both a sense of freedom and the responsibility to succeed. Supervision of faculty members seemed a prerequisite, and tended to be supportive rather than guiding., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
22. Evaluation of inter- and intra-operator reliability of manual segmentation of femoral metastatic lesions.
- Author
-
Ataei A, Eggermont F, Baars M, van der Linden Y, de Rooy J, Verdonschot N, and Tanck E
- Subjects
- Femur diagnostic imaging, Humans, Reproducibility of Results, Bone Neoplasms diagnostic imaging, Tomography, X-Ray Computed
- Abstract
Purpose: Accurate identification of metastatic lesions is important for improvement in biomechanical models that calculate the fracture risk of metastatic bones. The aim of this study was therefore to assess the inter- and intra-operator reliability of manual segmentation of femoral metastatic lesions., Methods: CT scans of 54 metastatic femurs (19 osteolytic, 17 osteoblastic, and 18 mixed) were segmented two times by two operators. Dice coefficients (DCs) were calculated adopting the quantification that a DC˃0.7 indicates good reliability., Results: Generally, rather poor inter- and intra-operator reliability of lesion segmentation were found. Inter-operator DCs were 0.54 (± 0.28) and 0.50 (± 0.32) for the first and second segmentations, respectively, whereas intra-operator DCs were 0.56 (± 0.28) for operator I and 0.71 (± 0.23) for operator II. Larger lesions scored significantly higher DCs in comparison with smaller lesions. Of the femurs with larger mean segmentation volumes, 83% and 93% were segmented with good inter- and intra-operator DCs (> 0.7), respectively. There was no difference between the mean DCs of osteolytic, osteoblastic, and mixed lesions., Conclusion: Manual segmentation of femoral bone metastases is very challenging and resulted in unsatisfactory mean reliability values. There is a need for development of a segmentation protocol to reduce the inter- and intra-operator segmentation variation as the first step and use of computer-assisted segmentation tools as a second step as this study shows that manual segmentation of femoral metastatic lesions is highly challenging., (© 2021. The Author(s).)
- Published
- 2021
- Full Text
- View/download PDF
23. Patient-specific finite element computer models improve fracture risk assessments in cancer patients with femoral bone metastases compared to clinical guidelines.
- Author
-
Eggermont F, van der Wal G, Westhoff P, Laar A, de Jong M, Rozema T, Kroon HM, Ayu O, Derikx L, Dijkstra S, Verdonschot N, van der Linden Y, and Tanck E
- Subjects
- Bone Density, Computer Simulation, Finite Element Analysis, Humans, Risk Assessment, Bone Neoplasms diagnostic imaging, Femur diagnostic imaging
- Abstract
Purpose: To determine whether patient-specific finite element (FE) computer models are better at assessing fracture risk for femoral bone metastases compared to clinical assessments based on axial cortical involvement on conventional radiographs, as described in current clinical guidelines., Methods: Forty-five patients with 50 femoral bone metastases, who were treated with palliative radiotherapy for pain, were included (64% single fraction (8Gy), 36% multiple fractions (5 or 6x4Gy)) and were followed for six months to determine whether they developed a pathological femoral fracture. All plain radiographs available within a two month period prior to radiotherapy were obtained. Patient-specific FE models were constructed based on the geometry and bone density obtained from the baseline quantitative CT scans used for radiotherapy planning. Femoral failure loads normalized for body weight (BW) were calculated. Patients with a failure load of 7.5 x BW or lower were identified as having high fracture risk, whereas patients with a failure load higher than 7.5 x BW were classified as low fracture risk. Experienced assessors measured axial cortical involvement on conventional radiographs. Following clinical guidelines, patients with lesions larger than 30mm were identified as having a high fracture risk. FE predictions were compared to clinical assessments by means of diagnostic accuracy values (sensitivity, specificity and positive (PPV) and negative predictive values (NPV))., Results: Seven femurs (14%) fractured during follow-up. Median time to fracture was 8 weeks. FE models were better at assessing fracture risk in comparison to axial cortical involvement (sensitivity 100% vs. 86%, specificity 74% vs. 42%, PPV 39% vs. 19%, and NPV 100% vs. 95%, for the FE computer model vs. axial cortical involvement, respectively)., Conclusions: Patient-specific FE computer models improve fracture risk assessments of femoral bone metastases in advanced cancer patients compared to clinical assessments based on axial cortical involvement, which is currently used in clinical guidelines., (Copyright © 2019 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
24. Calibration with or without phantom for fracture risk prediction in cancer patients with femoral bone metastases using CT-based finite element models.
- Author
-
Eggermont F, Verdonschot N, van der Linden Y, and Tanck E
- Subjects
- Bone Density, Bone Neoplasms secondary, Femur, Fractures, Bone diagnostic imaging, Fractures, Bone etiology, Humans, Neoplasms pathology, Tomography, X-Ray Computed methods, Bone Neoplasms complications, Calibration, Finite Element Analysis, Fractures, Bone diagnosis, Neoplasms complications, Phantoms, Imaging, Tomography, X-Ray Computed standards
- Abstract
The objective of this study was to develop a new calibration method that enables calibration of Hounsfield units (HU) to bone mineral densities (BMD) without the use of a calibration phantom for fracture risk prediction of femurs with metastases using CT-based finite element (FE) models. Fifty-seven advanced cancer patients (67 femurs with bone metastases) were CT scanned atop a separate calibration phantom using a standardized protocol. Non-linear isotropic FE models were constructed based on the phantom calibration and on two phantomless calibration methods: the "air-fat-muscle" and "non-patient-specific" calibration. For air-fat-muscle calibration, peaks for air, fat and muscle tissue were extracted from a histogram of the HU in a standardized region of interest including the patient's right leg and surrounding air. These CT peaks were linearly fitted to reference "BMD" values of the corresponding tissues to obtain a calibration function. For non-patient-specific calibration, an average phantom calibration function was used for all patients. FE failure loads were compared between phantom and phantomless calibrations. There were no differences in failure loads between phantom and air-fat-muscle calibration (p = 0.8), whereas there was a significant difference between phantom and non-patient-specific calibration (p<0.001). Although this study was not designed to investigate this, in four patients who were scanned using an aberrant reconstruction kernel, the effect of the different kernel seemed to be smaller for the air-fat-muscle calibration compared to the non-patient-specific calibration. With the air-fat-muscle calibration, clinical implementation of the FE model as tool for fracture risk assessment will be easier from a practical and financial viewpoint, since FE models can be made using everyday clinical CT scans without the need of concurrent scanning of calibration phantoms., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2019
- Full Text
- View/download PDF
25. Can patient-specific finite element models better predict fractures in metastatic bone disease than experienced clinicians?: Towards computational modelling in daily clinical practice.
- Author
-
Eggermont F, Derikx LC, Verdonschot N, van der Geest ICM, de Jong MAA, Snyers A, van der Linden YM, and Tanck E
- Abstract
Objectives: In this prospective cohort study, we investigated whether patient-specific finite element (FE) models can identify patients at risk of a pathological femoral fracture resulting from metastatic bone disease, and compared these FE predictions with clinical assessments by experienced clinicians., Methods: A total of 39 patients with non-fractured femoral metastatic lesions who were irradiated for pain were included from three radiotherapy institutes. During follow-up, nine pathological fractures occurred in seven patients. Quantitative CT-based FE models were generated for all patients. Femoral failure load was calculated and compared between the fractured and non-fractured femurs. Due to inter-scanner differences, patients were analyzed separately for the three institutes. In addition, the FE-based predictions were compared with fracture risk assessments by experienced clinicians., Results: In institute 1, median failure load was significantly lower for patients who sustained a fracture than for patients with no fractures. In institutes 2 and 3, the number of patients with a fracture was too low to make a clear distinction. Fracture locations were well predicted by the FE model when compared with post-fracture radiographs. The FE model was more accurate in identifying patients with a high fracture risk compared with experienced clinicians, with a sensitivity of 89% versus 0% to 33% for clinical assessments. Specificity was 79% for the FE models versus 84% to 95% for clinical assessments., Conclusion: FE models can be a valuable tool to improve clinical fracture risk predictions in metastatic bone disease. Future work in a larger patient population should confirm the higher predictive power of FE models compared with current clinical guidelines. Cite this article : F. Eggermont, L. C. Derikx, N. Verdonschot, I. C. M. van der Geest, M. A. A. de Jong, A. Snyers, Y. M. van der Linden, E. Tanck. Can patient-specific finite element models better predict fractures in metastatic bone disease than experienced clinicians? Towards computational modelling in daily clinical practice. Bone Joint Res 2018;7:430-439. DOI: 10.1302/2046-3758.76.BJR-2017-0325.R2., Competing Interests: Conflict of Interest Statement: None declared
- Published
- 2018
- Full Text
- View/download PDF
26. Effect of different CT scanners and settings on femoral failure loads calculated by finite element models.
- Author
-
Eggermont F, Derikx LC, Free J, van Leeuwen R, van der Linden YM, Verdonschot N, and Tanck E
- Abstract
In a multi-center patient study, using different CT scanners, CT-based finite element (FE) models are utilized to calculate failure loads of femora with metastases. Previous studies showed that using different CT scanners can result in different outcomes. This study aims to quantify the effects of (i) different CT scanners; (ii) different CT protocols with variations in slice thickness, field of view (FOV), and reconstruction kernel; and (iii) air between calibration phantom and patient, on Hounsfield Units (HU), bone mineral density (BMD), and FE failure load. Six cadaveric femora were scanned on four CT scanners. Scans were made with multiple CT protocols and with or without an air gap between the body model and calibration phantom. HU and calibrated BMD were determined in cortical and trabecular regions of interest. Non-linear isotropic FE models were constructed to calculate failure load. Mean differences between CT scanners varied up to 7% in cortical HU, 6% in trabecular HU, 6% in cortical BMD, 12% in trabecular BMD, and 17% in failure load. Changes in slice thickness and FOV had little effect (≤4%), while reconstruction kernels had a larger effect on HU (16%), BMD (17%), and failure load (9%). Air between the body model and calibration phantom slightly decreased the HU, BMD, and failure loads (≤8%). In conclusion, this study showed that quantitative analysis of CT images acquired with different CT scanners, and particularly reconstruction kernels, can induce relatively large differences in HU, BMD, and failure loads. Additionally, if possible, air artifacts should be avoided. © 2018 Orthopaedic Research Society. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res., (© 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society.)
- Published
- 2018
- Full Text
- View/download PDF
27. Limited short-term effect of palliative radiation therapy on quantitative computed tomography-derived bone mineral density in femora with metastases.
- Author
-
Eggermont F, Derikx LC, Verdonschot N, Hannink G, Kaatee RSJP, Tanck E, and van der Linden YM
- Abstract
Purpose: The aim of this study was to determine the effect of single fraction (SF) and multiple fraction (MF) radiation therapy (RT) on bone mineral density (BMD) in patients with cancer and bone metastases in the proximal femur. We studied this effect in the radiation field and within metastatic lesions, and differentiated between lytic, blastic, and mixed lesions., Methods and Materials: This prospective cohort study comprised 42 patients with painful bone metastases, including 47 irradiated femora with 52 metastatic lesions in the proximal femur. Patients received either 8 Gy SF or 20 to 24 Gy in 5 to 6 fractions (MF). Quantitative computed tomography scans were obtained before RT and 4 and 10 weeks after the initial scan. Patients who received MF additionally underwent quantitative computed tomography on the final day of their treatment. Automated image registration was performed. Mean BMD was determined at each time point for each proximal femur (region of interest [ROI]-PF) and in greater detail for a region of interest that contained the metastatic lesion (ROI-ML). Statistical analysis was performed using linear mixed models., Results: No significant differences in mean BMD were found between SF or MF RT over all time points in both ROI-PF and ROI-ML. Mean BMD did not change in ROI-PF with lytic and mixed lesions, but mean BMD in ROI-PF with blastic lesions increased to 109%. Comparably, when focused on ROI-ML, no differences in mean BMD were observed in lytic ROI-ML but mean BMD in mixed and blastic ROI-ML increased up to 105% and 121%, respectively., Conclusions: Ten weeks after palliative radiation therapy in patients with femoral metastatic lesions, a limited increase in BMD was seen with no beneficial effect of MF over SF RT. BMD in lytic lesions was unchanged but slightly increased in mixed and blastic lesions.
- Published
- 2016
- Full Text
- View/download PDF
28. The assisted 6-minute cycling test to assess endurance in children with a neuromuscular disorder.
- Author
-
Jansen M, De Jong M, Coes HM, Eggermont F, Van Alfen N, and De Groot IJ
- Subjects
- Adolescent, Child, Feasibility Studies, Humans, Male, Exercise Test methods, Exercise Test standards, Muscular Dystrophy, Duchenne diagnosis, Muscular Dystrophy, Duchenne physiopathology, Physical Endurance physiology
- Abstract
Introduction: For late- or non-ambulant children with a neuromuscular disorder no suitable endurance tests are currently available. We developed the assisted 6-minute cycling test (A6MCT) for the legs and arms and investigated its psychometric properties in healthy boys and boys with Duchenne muscular dystrophy (DMD)., Methods: Ninety-nine healthy boys and 30 boys with DMD (12 wheelchair-dependent) performed the A6MCT. Seventy healthy boys also performed the 6-minute walk test (6MWT), and 23 boys performed the A6MCT twice within 2 weeks. Boys with DMD also performed the Motor Function Measure (MFM)., Results: The A6MCT was feasible for >90% of all boys. Boys with DMD achieved fewer cycling revolutions than controls. The A6MCT was positively correlated with the 6MWT and was reproducible in healthy boys, and it correlated with disease severity in boys with DMD., Conclusions: The A6MCT is a promising outcome measure for the follow-up of non-ambulant children with a neuromuscular disorder., (Copyright © 2012 Wiley Periodicals, Inc.)
- Published
- 2012
- Full Text
- View/download PDF
29. Step performance in persons with rheumatoid arthritis: a case-control study.
- Author
-
Smulders E, van Lankveld W, Eggermont F, Duysens J, and Weerdesteyn V
- Subjects
- Accidental Falls prevention & control, Accidental Falls statistics & numerical data, Arthritis, Rheumatoid rehabilitation, Case-Control Studies, Electromyography, Fear, Female, Humans, Male, Middle Aged, Mobility Limitation, Pain Measurement, Postural Balance physiology, Reaction Time, Surveys and Questionnaires, Arthritis, Rheumatoid physiopathology
- Abstract
Objective: To investigate factors that could lead to falls in patients with rheumatoid arthritis (RA)., Design: Case-control study., Setting: Hospital., Participants: Patients with RA (n=15) and age- and sex-matched controls (n=15; mean ± SD age, 60.5 ± 7.1y)., Interventions: Not applicable., Main Outcome Measures: Performance of participants on a step task. Furthermore, manual performance was assessed, as well as questionnaires for balance confidence, fear of falling, and activity level., Results: Patients with RA showed nonsignificantly increased RTs (time to anticipatory postural adjustment and foot lift) and significantly increased movement times (MTs). Push-off force and step velocity were significantly lower in patients with RA. During a manual task, delayed RTs and MTs were seen. Moreover, lower levels of balance confidence and more fear of falling were reported in patients with RA. There were no differences in activity levels., Conclusions: When performing a quick step, patients with RA show delayed MT and step velocity and decreased push off. Because quick stepping often is used to avoid falls, the increase in step execution time might have undesirable consequences. Furthermore, patients with RA have lower balance confidence and more fear of falling than healthy controls; these factors also contribute to higher fall risk., (Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.)
- Published
- 2011
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.