28 results on '"Dul MW"'
Search Results
2. Rapid pupil-based assessment of glaucomatous damage.
- Author
-
Chen Y, Wyatt HJ, Swanson WH, Dul MW, Chen, Yanjun, Wyatt, Harry J, Swanson, William H, and Dul, Mitchell W
- Published
- 2008
- Full Text
- View/download PDF
3. Self-limiting resolution of netarsudil induced bullous epitheliopathy.
- Author
-
Dellostritto S, Winter K, Gould Blackmore J, Pereira S, and Dul MW
- Published
- 2024
- Full Text
- View/download PDF
4. ISCEV and IPS guideline for the full-field stimulus test (FST).
- Author
-
Jolly JK, Grigg JR, McKendrick AM, Fujinami K, Cideciyan AV, Thompson DA, Matsumoto C, Asaoka R, Johnson C, Dul MW, Artes PH, and Robson AG
- Subjects
- Societies, Medical, Photic Stimulation methods, Vision, Ocular, Electroretinography methods, Visual Field Tests
- Abstract
The full-field stimulus test (FST) is a psychophysical technique designed for the measurement of visual function in low vision. The method involves the use of a ganzfeld stimulator, as used in routine full-field electroretinography, to deliver full-field flashes of light. This guideline was developed jointly by the International Society for Clinical Electrophysiology of Vision (ISCEV) and Imaging and Perimetry Society (IPS) in order to provide technical information, promote consistency of testing and reporting, and encourage convergence of methods for FST. It is intended to aid practitioners and guide the formulation of FST protocols, with a view to future standardisation., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
5. Contrast Sensitivity of ON and OFF Human Retinal Pathways in Myopia.
- Author
-
Poudel S, Jin J, Rahimi-Nasrabadi H, Dellostritto S, Dul MW, Viswanathan S, and Alonso JM
- Subjects
- Humans, Retina physiology, Vision, Ocular, Electroretinography, Photic Stimulation, Contrast Sensitivity, Myopia
- Abstract
The human visual cortex processes light and dark stimuli with ON and OFF pathways that are differently modulated by luminance contrast. We have previously demonstrated that ON cortical pathways have higher contrast sensitivity than OFF cortical pathways and the difference increases with luminance range (defined as the maximum minus minimum luminance in the scene). Here, we demonstrate that these ON-OFF cortical differences are already present in the human retina and that retinal responses measured with electroretinography are more affected by reductions in luminance range than cortical responses measured with electroencephalography. Moreover, we show that ON-OFF pathway differences measured with electroretinography become more pronounced in myopia, a visual disorder that elongates the eye and blurs vision at far distance. We find that, as the eye axial length increases across subjects, ON retinal pathways become less responsive, slower in response latency, less sensitive, and less effective and slower at driving pupil constriction. Based on these results, we conclude that myopia is associated with a deficit in ON pathway function that decreases the ability of the retina to process low contrast and regulate retinal illuminance in bright environments., (Copyright © 2024 Poudel et al.)
- Published
- 2024
- Full Text
- View/download PDF
6. Luminance Contrast Shifts Dominance Balance between ON and OFF Pathways in Human Vision.
- Author
-
Rahimi-Nasrabadi H, Moore-Stoll V, Tan J, Dellostritto S, Jin J, Dul MW, and Alonso JM
- Subjects
- Male, Animals, Female, Humans, Vision, Ocular, Visual Fields, Contrast Sensitivity, Visual Pathways physiology, Photic Stimulation, Visual Perception physiology, Visual Cortex physiology
- Abstract
Human vision processes light and dark stimuli in visual scenes with separate ON and OFF neuronal pathways. In nature, stimuli lighter or darker than their local surround have different spatial properties and contrast distributions (Ratliff et al., 2010; Cooper and Norcia, 2015; Rahimi-Nasrabadi et al., 2021). Similarly, in human vision, we show that luminance contrast affects the perception of lights and darks differently. At high contrast, human subjects of both sexes locate dark stimuli faster and more accurately than light stimuli, which is consistent with a visual system dominated by the OFF pathway. However, at low contrast, they locate light stimuli faster and more accurately than dark stimuli, which is consistent with a visual system dominated by the ON pathway. Luminance contrast was strongly correlated with multiple ON/OFF dominance ratios estimated from light/dark ratios of performance errors, missed targets, or reaction times (RTs). All correlations could be demonstrated at multiple eccentricities of the central visual field with an ON-OFF perimetry test implemented in a head-mounted visual display. We conclude that high-contrast stimuli are processed faster and more accurately by OFF pathways than ON pathways. However, the OFF dominance shifts toward ON dominance when stimulus contrast decreases, as expected from the higher-contrast sensitivity of ON cortical pathways (Kremkow et al., 2014; Rahimi-Nasrabadi et al., 2021). The results highlight the importance of contrast polarity in visual field measurements and predict a loss of low-contrast vision in humans with ON pathway deficits, as demonstrated in animal models (Sarnaik et al., 2014). SIGNIFICANCE STATEMENT ON and OFF retino-thalamo-cortical pathways respond differently to luminance contrast. In both animal models and humans, low contrasts drive stronger responses from ON pathways, whereas high contrasts drive stronger responses from OFF pathways. We demonstrate that these ON-OFF pathway differences have a correlate in human vision. At low contrast, humans locate light targets faster and more accurately than dark targets but, as contrast increases, dark targets become more visible than light targets. We also demonstrate that contrast is strongly correlated with multiple light/dark ratios of visual performance in central vision. These results provide a link between neuronal physiology and human vision while emphasizing the importance of stimulus polarity in measurements of visual fields and contrast sensitivity., (Copyright © 2023 Rahimi-Nasrabadi et al.)
- Published
- 2023
- Full Text
- View/download PDF
7. Neuronal mechanisms underlying differences in spatial resolution between darks and lights in human vision.
- Author
-
Pons C, Mazade R, Jin J, Dul MW, Zaidi Q, and Alonso JM
- Subjects
- Electroretinography, Humans, Lighting, Adaptation, Ocular physiology, Retina physiology, Visual Acuity, Visual Cortex physiology, Visual Pathways physiology, Visual Perception physiology
- Abstract
Artists and astronomers noticed centuries ago that humans perceive dark features in an image differently from light ones; however, the neuronal mechanisms underlying these dark/light asymmetries remained unknown. Based on computational modeling of neuronal responses, we have previously proposed that such perceptual dark/light asymmetries originate from a luminance/response saturation within the ON retinal pathway. Consistent with this prediction, here we show that stimulus conditions that increase ON luminance/response saturation (e.g., dark backgrounds) or its effect on light stimuli (e.g., optical blur) impair the perceptual discrimination and salience of light targets more than dark targets in human vision. We also show that, in cat visual cortex, the magnitude of the ON luminance/response saturation remains relatively constant under a wide range of luminance conditions that are common indoors, and only shifts away from the lowest luminance contrasts under low mesopic light. Finally, we show that the ON luminance/response saturation affects visual salience mostly when the high spatial frequencies of the image are reduced by poor illumination or optical blur. Because both low luminance and optical blur are risk factors in myopia, our results suggest a possible neuronal mechanism linking myopia progression with the function of the ON visual pathway.
- Published
- 2017
- Full Text
- View/download PDF
8. Individual differences in the shape of the nasal visual field.
- Author
-
Swanson WH, Dul MW, Horner DG, and Malinovsky VE
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Individuality, Longitudinal Studies, Male, Middle Aged, Photic Stimulation methods, Prospective Studies, Sensory Thresholds physiology, Visual Field Tests, Young Adult, Contrast Sensitivity physiology, Visual Fields physiology
- Abstract
Between-subject differences in the shape of the nasal visual field were assessed for 103 volunteers 21-85years of age and free of visual disorder. Perimetry was conducted with a stimulus for which contrast sensitivity is minimally affected by peripheral defocus and decreased retinal illumination. One eye each was tested for 103 volunteers free of eye disease in a multi-center prospective longitudinal study. A peripheral deviation index was computed as the difference in log contrast sensitivity at outer (25-29° nasal) and inner (8° from fixation) locations. Values for this index ranged from 0.01 (outer sensitivity slightly greater than inner sensitivity) to -0.7 log unit (outer sensitivity much lower than inner sensitivity). Mean sensitivity for the inner locations was independent of the deviation index (R
2 <1%), while mean sensitivity for the outer locations was not (R2 =38%, p<0.0005). Age was only modestly related to the index, with a decline by 0.017 log unit per decade (R2 =10%). Test-retest data for 21 volunteers who completed 7-10 visits yielded standard deviations for the index from 0.04 to 0.17 log unit, with a mean of 0.09 log unit. Between-subject differences in peripheral deviation persisted over two years of longitudinal testing. Peripheral deviation indices were correlated with indices for three other perimetric stimuli used in a subset of 24 volunteers (R2 from 20% to 49%). Between-subject variability in shape of the visual field raises concerns about current clinical visual field indices, and further studies are needed to develop improved indices., (Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.)- Published
- 2017
- Full Text
- View/download PDF
9. Contrast sensitivity perimetry data from adults free of eye disease.
- Author
-
Swanson WH, Dul MW, Horner DG, and Malinovsky VE
- Abstract
This data article contains data referenced in "Individual Differences in the Shape of the Nasal Visual Field" [1]. The data were gathered from volunteers free of eye disease ages 21-85 who were tested with Contrast Sensitivity Perimetry (CSP), which uses a stimulus resistant to effects of defocus and reduced retinal illumination. Some subjects were tested only once or a few times, and others were part of a longitudinal cohort with as many as 10 tests. Parameters from maximum likelihood estimation of psychophysical threshold at each tested location are included in the data file, along with the participant׳s sex, age at time of test, the center of their physiological blind spot, the duration of test, the time of day that the test was begun, and the starting contrast used for the psychophysical staircases.
- Published
- 2016
- Full Text
- View/download PDF
10. Effect of Age and Glaucoma on the Detection of Darks and Lights.
- Author
-
Zhao L, Sendek C, Davoodnia V, Lashgari R, Dul MW, Zaidi Q, and Alonso JM
- Subjects
- Age Factors, Aged, Aged, 80 and over, Case-Control Studies, Darkness, Female, Glaucoma, Open-Angle physiopathology, Humans, Light, Male, Middle Aged, Glaucoma physiopathology, Visual Perception physiology
- Abstract
Purpose: We have shown previously that normal observers detect dark targets faster and more accurately than light targets, when presented in noisy backgrounds. We investigated how these differences in detection time and accuracy are affected by age and ganglion cell pathology associated with glaucoma., Methods: We asked 21 glaucoma patients, 21 age-similar controls, and 5 young control observers to report as fast as possible the number of 1 to 3 light or dark targets. The targets were positioned at random in a binary noise background, within the central 30° of the visual field., Results: We replicate previous findings that darks are detected faster and more accurately than lights. We extend these findings by demonstrating that differences in detection of darks and lights are found reliably across different ages and in observers with glaucoma. We show that differences in detection time increase at a rate of approximately 55 msec/dB at early stages of glaucoma and then remain constant at later stages at approximately 800 msec. In normal subjects, differences in detection time increase with age at a rate of approximately 8 msec/y. We also demonstrate that the accuracy to detect lights and darks is significantly correlated with the severity of glaucoma and that the mean detection time is significantly longer for subjects with glaucoma than age-similar controls., Conclusions: We conclude that differences in detection of darks and lights can be demonstrated over a wide range of ages, and asymmetries in dark/light detection increase with age and early stages of glaucoma.
- Published
- 2015
- Full Text
- View/download PDF
11. Contrast sensitivity perimetry and clinical measures of glaucomatous damage.
- Author
-
Swanson WH, Malinovsky VE, Dul MW, Malik R, Torbit JK, Sutton BM, and Horner DG
- Subjects
- Aged, Aged, 80 and over, Female, Glaucoma physiopathology, Gonioscopy, Humans, Intraocular Pressure, Male, Middle Aged, Optic Nerve Diseases physiopathology, Contrast Sensitivity physiology, Glaucoma diagnosis, Nerve Fibers pathology, Optic Nerve Diseases diagnosis, Retinal Ganglion Cells pathology, Visual Field Tests, Visual Fields physiology
- Abstract
Purpose: To compare conventional structural and functional measures of glaucomatous damage with a new functional measure-contrast sensitivity perimetry (CSP-2)., Methods: One eye each was tested for 51 patients with glaucoma and 62 age-similar control subjects using CSP-2, size III 24-2 conventional automated perimetry (CAP), 24-2 frequency-doubling perimetry (FDP), and retinal nerve fiber layer (RNFL) thickness. For superior temporal (ST) and inferior temporal (IT) optic disc sectors, defect depth was computed as amount below mean normal, in log units. Bland-Altman analysis was used to assess agreement on defect depth, using limits of agreement and three indices: intercept, slope, and mean difference. A criterion of p < 0.0014 for significance used Bonferroni correction., Results: Contrast sensitivity perimetry-2 and FDP were in agreement for both sectors. Normal variability was lower for CSP-2 than for CAP and FDP (F > 1.69, p < 0.02), and Bland-Altman limits of agreement for patient data were consistent with variability of control subjects (mean difference, -0.01 log units; SD, 0.11 log units). Intercepts for IT indicated that CSP-2 and FDP were below mean normal when CAP was at mean normal (t > 4, p < 0.0005). Slopes indicated that, as sector damage became more severe, CAP defects for IT and ST deepened more rapidly than CSP-2 defects (t > 4.3, p < 0.0005) and RNFL defects for ST deepened more slowly than for CSP, FDP, and CAP. Mean differences indicated that FDP defects for ST and IT were on average deeper than RNFL defects, as were CSP-2 defects for ST (t > 4.9, p < 0.0001)., Conclusions: Contrast sensitivity perimetry-2 and FDP defects were deeper than CAP defects in optic disc sectors with mild damage and revealed greater residual function in sectors with severe damage. The discordance between different measures of glaucomatous damage can be accounted for by variability in people free of disease.
- Published
- 2014
- Full Text
- View/download PDF
12. Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects.
- Author
-
Swanson WH, Horner DG, Dul MW, and Malinovsky VE
- Abstract
Purpose: To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects., Methods: Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability., Results: Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively ( F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively ( P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower ( P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units)., Conclusions: Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli., Translational Relevance: The guidelines should allow developers to choose from a wide range of stimuli.
- Published
- 2014
- Full Text
- View/download PDF
13. Assessing spatial and temporal properties of perimetric stimuli for resistance to clinical variations in retinal illumination.
- Author
-
Swanson WH, Dul MW, Horner DG, Liu T, and Tran I
- Subjects
- Adolescent, Adult, Female, Humans, Male, Middle Aged, Sensory Thresholds, Visual Field Tests methods, Young Adult, Lighting, Photic Stimulation methods, Psychophysics methods, Retina physiology, Visual Fields physiology
- Abstract
Purpose: To develop perimetric stimuli for which sensitivities are more resistant to reduced retinal illumination than current clinical perimeters., Methods: Fifty-four people free of eye disease were dilated and tested monocularly. For each test, retinal illumination was attenuated with neutral density (ND) filters, and a standard adaptation model was fit to derive mean and SEM for the adaptation parameter (NDhalf). For different stimuli, t-tests on NDhalf were used to assess significance of differences in consistency with Weber's law. Three experiments used custom Gaussian-windowed contrast sensitivity perimetry (CSP). Experiment 1 used CSP-1, with a Gaussian temporal pulse, a spatial frequency of 0.375 cyc/deg (cpd), and SD of 1.5°. Experiment 1 also used the Humphrey Matrix perimeter, with the N-30 test using 0.25 cpd and 25 Hz flicker. Experiment 2 used a rectangular temporal pulse, SDs of 0.25° and 0.5°, and spatial frequencies of 0.0 and 1.0 cpd. Experiment 3 used CSP-2, with 5-Hz flicker, SDs from 0.5° to 1.8°, and spatial frequencies from 0.14 to 0.50 cpd., Results: In Experiment 1, CSP-1 was more consistent with Weber's law (NDhalf ± SEM = 1.86 ± 0.08 log unit) than N-30 (NDhalf = 1.03 ± 0.03 log unit; t > 9, P < 0.0001). All stimuli used in Experiments 2 and 3 had comparable consistency with Weber's law (NDhalf = 1.49-1.69 log unit; t < 2)., Conclusions: Perimetric sensitivities were consistent with Weber's law when higher temporal frequencies were avoided.
- Published
- 2014
- Full Text
- View/download PDF
14. Blur-resistant perimetric stimuli.
- Author
-
Horner DG, Dul MW, Swanson WH, Liu T, and Tran I
- Subjects
- Adult, Female, Follow-Up Studies, Humans, Male, Photic Stimulation, Reference Values, Young Adult, Contrast Sensitivity physiology, Psychophysics methods, Sensory Thresholds, Visual Field Tests methods, Visual Fields physiology
- Abstract
Purpose: To develop perimetric stimuli that are resistant to the effects of peripheral defocus., Methods: One eye each was tested on subjects free of eye disease. Experiment 1 assessed spatial frequency, testing 12 subjects at eccentricities from 2 to 7 degrees using blur levels from 0 to 3 diopters (D) for two (Gabor) stimuli (spatial SD, 0.5 degrees; spatial frequencies, 0.5 and 1.0 cycles per degree [cpd]). Experiment 2 assessed stimulus size, testing 12 subjects at eccentricities from 4 to 7 degrees using blur levels 0 to 6 D for two Gaussians with SD of 0.5 and 0.25 degrees and a 0.5-cpd Gabor with SD of 0.5 degrees. Experiment 3 tested 13 subjects at eccentricities from fixation to 27 degrees using blur levels 0 to 6 D for Gabor stimuli at 56 locations; the spatial frequency ranged from 0.14 to 0.50 cpd with location, and SD was scaled accordingly., Results: In experiment 1, blur by 3 D caused a small decline in log contrast sensitivity for the 0.5-cpd stimulus (mean ± SE, 0.09 ± 0.08 log units) and a larger (t = 7.7, p < 0.0001) decline for the 1.0-cpd stimulus (0.37 ± 0.13 log units). In experiment 2, blur by 6 D caused minimal decline for the larger Gaussian, by 0.17 ± 0.16 log units, and larger (t > 4.5, p < 0.001) declines for the smaller Gaussian (0.33 ± 0.16 log units) and the Gabor (0.36 ± 0.18 log units). In experiment 3, blur by 6 D caused declines by 0.27 ± 0.05 log units for eccentricities from 0 to 10 degrees, by 0.20 ± 0.04 log units for eccentricities from 10 to 20 degrees, and 0.13 ± 0.03 log units for eccentricities from 20 to 27 degrees., Conclusions: Experiments 1 and 2 allowed us to design stimuli for experiment 3 that were resistant to effects of peripheral defocus.
- Published
- 2013
- Full Text
- View/download PDF
15. Optimizing contrast sensitivity perimetry for clinical use.
- Author
-
Dul MW
- Published
- 2013
16. Web-based training on weapons of mass destruction response for emergency medical services personnel.
- Author
-
Gershon RR, Canton AN, Magda LA, DiMaggio C, Gonzalez D, and Dul MW
- Subjects
- Adult, Clinical Competence, Cohort Studies, Computer Simulation, Eye Injuries diagnosis, Eye Injuries etiology, Female, Humans, Male, Middle Aged, New York, Program Evaluation, Education, Distance, Emergency Medical Services, Eye Injuries therapy, Internet, Problem-Based Learning methods, Weapons of Mass Destruction
- Abstract
Objective: To develop, implement, and assess a web-based simulation training program for emergency medical services (EMS) personnel on recognition and treatment of ocular injuries resulting from weapons of mass destruction (WMD) attacks., Design: The training program consisted of six modules: WMD knowledge and event detection, ocular anatomy, ocular first aid (ie, flushing, cupping, and patching), and three WMD simulations (ie, sarin gas release, anthrax release, and radioactive dispersal device). Pretest, post-test, and 1-month follow-up test and a program evaluation were used to measure knowledge gain and retention and to assess the effectiveness of the program., Setting: New York State EMS., Participants: Four hundred and sixty-four individuals participated in the training program and all waves of the testing (86 percent retention rate)., Main Outcome Variables: The effectiveness of the training intervention was measured using pretest and post-test questionnaires and analyzed using dependent t-tests., Results: Assessment scores for overall knowledge increased from the pretest (mean = 15.7, standard deviation [SD] = 2.1) to the post-test (mean = 17.8, SD = 1.3), p < 0.001, and from pretest (mean = 15.7, SD = 2.1) to 1-month follow-up test (mean = 16.6, SD = 2.0), p < 0.001. Ninety-two percent of respondents indicated that the program reinforced understanding of WMDs., Conclusions: This training method provides an effective and low-cost approach to educate and evaluate EMS personnel on emergency treatment of eye trauma associated with the use of WMD. Online training should also be supplemented with hands-on practice and refresher trainings.
- Published
- 2009
17. Assessment of contrast gain signature in inferred magnocellular and parvocellular pathways in patients with glaucoma.
- Author
-
Sun H, Swanson WH, Arvidson B, and Dul MW
- Subjects
- Adult, Aged, Discrimination, Psychological, Glaucoma physiopathology, Glaucoma, Open-Angle physiopathology, Glaucoma, Open-Angle psychology, Humans, Middle Aged, Models, Neurological, Models, Psychological, Photic Stimulation methods, Psychophysics, Retinal Ganglion Cells physiology, Sensory Thresholds, Contrast Sensitivity, Glaucoma psychology, Visual Pathways physiopathology
- Abstract
Purpose: Contrast gain signatures of inferred magnocellular and parvocellular postreceptoral pathways were assessed for patients with glaucoma using a contrast discrimination paradigm developed by Pokorny and Smith. The potential causes for changes in contrast gain signature were investigated using model simulations of ganglion cell contrast responses., Methods: Foveal contrast discrimination thresholds were measured with a pedestal-Delta-pedestal paradigm developed by Pokorny and Smith [Pokorny, J., & Smith, V. C. (1997). Psychophysical signatures associated with magnocellular and parvocellular pathway contrast gain. Journal of the Optical Society of America A, 14(9), 2477-2486]. Stimuli were 27 ms luminance increments superimposed on 227 ms pulsed Delta-pedestals. Contrast thresholds and contrast gain signatures mediated by the inferred magnocellular (MC) and parvocellular (PC) pathways were assessed using linear fits to contrast discrimination thresholds at either lower or higher Delta-pedestal contrasts, respectively. Twenty-seven patients with glaucoma were tested, as well as 16 age-similar control subjects free of eye disease., Results: Contrast sensitivity and contrast gain signature mediated by the inferred MC pathway were lower for the glaucoma group, and reduced contrast gain signature was correlated with reduced contrast sensitivity (r(2)=45%, p<.0005). These two parameters mediated by the inferred PC pathway were little affected for the glaucoma group. Model simulations suggest that the reduced contrast sensitivity and contrast gain signature were consistent with the hypothesis that reduced MC ganglion cell dendritic complexity can lead to reduced effective retinal illuminance, and hence increased semi-saturation contrast of the ganglion cell contrast response functions., Conclusions: The contrast sensitivity and contrast gain signature of the inferred MC pathway were reduced in patients with glaucoma. The results were consistent with a model of ganglion cell dysfunction due to reduced synaptic density.
- Published
- 2008
- Full Text
- View/download PDF
18. Development and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.
- Author
-
Hot A, Dul MW, and Swanson WH
- Subjects
- Adult, Aged, Automation, Humans, Middle Aged, Reproducibility of Results, Retina pathology, Tomography, Visual Field Tests standards, Contrast Sensitivity, Glaucoma diagnosis, Glaucoma physiopathology, Visual Field Tests methods
- Abstract
Purpose: To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss., Methods: Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gabor patches with a peak spatial frequency of 0.4 cyc/deg and a two-dimensional spatial Gaussian envelope, with most of the energy concentrated within a 4 degrees circular region. Threshold was estimated by a staircase method: Patients and 10 age-similar control subjects were also tested on conventional automated perimetry (CAP), with the 24-2 pattern with the SITA Standard testing strategy. The neuroretinal rim area of the patients was measured with a retinal tomograph (Retina Tomograph II [HRT]; Heidelberg Engineering, Heidelberg, Germany). A Bland-Altman analysis of agreement was used to assess test-retest variability, compare depth of defect shown by the two perimetric tests, and investigate the relations between contrast sensitivity and neuroretinal rim area., Results: Variability showed less dependence on defect depth for CSP than for CAP (z = 9.3, P < 0.001). Defect depth was similar for CAP and CSP when averaged by quadrant (r = 0.26, P > 0.13). The relation between defect depth and rim area was more consistent with CSP than with CAP (z = 9, P < 0.001)., Conclusions: The implementation of CSP was successful in reducing test-retest variability in glaucomatous defects. CSP was in general agreement with CAP in terms of depth of defect and was in better agreement than CAP with HRT-determined rim area.
- Published
- 2008
- Full Text
- View/download PDF
19. Variability of visual field measurements is correlated with the gradient of visual sensitivity.
- Author
-
Wyatt HJ, Dul MW, and Swanson WH
- Subjects
- Adult, Aged, Contrast Sensitivity physiology, Fixation, Ocular physiology, Humans, Middle Aged, Reproducibility of Results, Visual Field Tests methods, Eye Movements physiology, Glaucoma physiopathology, Visual Fields physiology, Visual Perception physiology
- Abstract
Conventional static automated perimetry provides important clinical information, but its utility is limited by considerable test-retest variability. Fixational eye movements during testing could contribute to variability. To assess this possibility, it is important to know how much sensitivity change would be caused by a given eye movement. To investigate this, we have evaluated the gradient, the rate at which sensitivity changes with location. We tested one eye each, twice within 3 weeks, of 29 patients with glaucoma, 17 young normal subjects and 13 older normal subjects. The 10-2 test pattern with the SITA Standard algorithm was used to assess sensitivity at locations with 2 degrees spacing. Variability and gradient were calculated at individual test locations. Matrix correlations were determined between variability and gradient, and were substantial for the patients with glaucoma. The results were consistent with a substantial contribution to test-retest variability from small fixational eye movements interacting with visual field gradient. Successful characterization of the gradient of sensitivity appears to require sampling at relatively close spacing, as in the 10-2 test pattern.
- Published
- 2007
- Full Text
- View/download PDF
20. Linearity can account for the similarity among conventional, frequency-doubling, and gabor-based perimetric tests in the glaucomatous macula.
- Author
-
Sun H, Dul MW, and Swanson WH
- Subjects
- Adult, Aged, Aged, 80 and over, Algorithms, Humans, Middle Aged, Photic Stimulation, Retinal Ganglion Cells physiology, Contrast Sensitivity physiology, Glaucoma physiopathology, Macula Lutea physiopathology, Models, Theoretical, Visual Field Tests methods, Visual Fields physiology
- Abstract
Purposes: The purposes of this study are to compare macular perimetric sensitivities for conventional size III, frequency-doubling, and Gabor stimuli in terms of Weber contrast and to provide a theoretical interpretation of the results., Methods: Twenty-two patients with glaucoma performed four perimetric tests: a conventional Swedish Interactive Threshold Algorithm (SITA) 10-2 test with Goldmann size III stimuli, two frequency-doubling tests (FDT 10-2, FDT Macula) with counterphase-modulated grating stimuli, and a laboratory-designed test with Gabor stimuli. Perimetric sensitivities were converted to the reciprocal of Weber contrast and sensitivities from different tests were compared using the Bland-Altman method. Effects of ganglion cell loss on perimetric sensitivities were then simulated with a two-stage neural model., Results: The average perimetric loss was similar for all stimuli until advanced stages of ganglion cell loss, in which perimetric loss tended to be greater for size III stimuli than for frequency-doubling and Gabor stimuli. Comparison of the experimental data and model simulation suggests that, in the macula, linear relations between ganglion cell loss and perimetric sensitivity loss hold for all three stimuli., Conclusions: Linear relations between perimetric loss and ganglion cell loss for all three stimuli can account for the similarity in perimetric loss until advanced stages. The results do not support the hypothesis that redundancy for frequency-doubling stimuli is lower than redundancy for size III stimuli.
- Published
- 2006
- Full Text
- View/download PDF
21. Evaluation of a two-stage neural model of glaucomatous defect: an approach to reduce test-retest variability.
- Author
-
Pan F, Swanson WH, and Dul MW
- Subjects
- Color Perception physiology, Humans, Photic Stimulation, Severity of Illness Index, Visual Field Tests, Glaucoma physiopathology, Neural Networks, Computer, Retinal Ganglion Cells physiology, Visual Cortex physiopathology, Visual Fields physiology
- Abstract
Purpose: The purpose of this study is to model perimetric defect and variability and identify stimulus conditions that can reduce variability while retaining good ability to detect glaucomatous defects., Methods: The two-stage neural model of Swanson et al. was extended to explore relations among perimetric defect, response variability, and heterogeneous glaucomatous ganglion cell damage. Predictions of the model were evaluated by testing patients with glaucoma using a standard luminance increment 0.43 degrees in diameter and two innovative stimuli designed to tap cortical mechanisms tuned to low spatial frequencies. The innovative stimuli were a luminance-modulated Gabor stimulus (0.5 c/deg) and circular equiluminant red-green chromatic stimuli whose sizes were close to normal Ricco's areas for the chromatic mechanism. Seventeen patients with glaucoma were each tested twice within a 2-week period. Sensitivities were measured at eight locations at eccentricities from 10 degrees to 21 degrees selected in terms of the retinal nerve fiber bundle patterns. Defect depth and response (test-retest) variability were compared for the innovative stimuli and the standard stimulus., Results: The model predicted that response variability in defective areas would be lower for our innovative stimuli than for the conventional perimetric stimulus with similar defect depths if detection of the chromatic and Gabor stimuli was mediated by spatial mechanisms tuned to low spatial frequencies. Experimental data were consistent with these predictions. Depth of defect was similar for all three stimuli (F = 1.67, p > 0.19). Mean response variability was lower for the chromatic stimulus than for the other stimuli (F = 5.58, p < 0.005) and was lower for the Gabor stimulus than for the standard stimulus in areas with more severe defects (t = 2.68, p < 0.005). Variability increased with defect depth for the standard and Gabor stimuli (p < 0.005) but not for the chromatic stimulus (slope less than zero)., Conclusions: Use of large perimetric stimuli detected by cortical mechanisms tuned to low spatial frequencies can make it possible to lower response variability without comprising the ability to detect glaucomatous defect.
- Published
- 2006
- Full Text
- View/download PDF
22. Quantifying effects of retinal illuminance on frequency doubling perimetry.
- Author
-
Swanson WH, Dul MW, and Fischer SE
- Subjects
- Adaptation, Ocular physiology, Adult, Female, Humans, Lens, Crystalline physiology, Male, Middle Aged, Miotics administration & dosage, Mydriatics administration & dosage, Practice Guidelines as Topic, Pupil drug effects, Pupil physiology, Sensitivity and Specificity, Lighting, Retina physiology, Visual Field Tests methods, Visual Fields physiology
- Abstract
Purpose: To measure and quantify effects of variation in retinal illuminance on frequency doubling technology (FDT) perimetry., Methods: A Zeiss-Humphrey/Welch Allyn FDT perimeter was used with the threshold N-30 strategy. Study 1, quantifying adaptation: 11 eyes of 11 subjects (24-46 years old) were tested with natural pupils, and then retested after stable pupillary dilation with neutral density filters of 0.0, 0.6, 1.2, and 1.6 log unit in front of the subject's eye. Study 2, predicting effect of reduced illuminance: 17 eyes of 17 subjects (26-61 years old) were tested with natural pupils, and then retested after stable pupillary miosis (assessed with an infrared camera). A quantitative adaptation model was fit to results of Study 1; the mean adaptation parameter was used to predict change in Study 2., Results: Study 1: Mean defect (MD) decreased by 10 dB over a 1.6 log unit range of retinal illuminances; model fits for all subjects had r2> 95%. Study 2: Change in MD (DeltaMD) ranged from -7.3 dB to +0.8 dB. The mean adaptation parameter from Study 1 accounted for 69% of the variance in DeltaMD (P <0.0005), and accuracy of the model was independent of the magnitude of DeltaMD (r2< 1%, P >0.75)., Conclusions: The results confirmed previous findings that FDT perimetry can be dramatically affected by variations in retinal illuminance. Application of a quantitative adaptation model provided guidelines for estimating effects of pupil diameter and lens density on FDT perimetry.
- Published
- 2005
- Full Text
- View/download PDF
23. Editorial.
- Author
-
Dul MW, Kelly MS, and Thomann H
- Published
- 2000
- Full Text
- View/download PDF
24. Abnormal gait in neurologic disease.
- Author
-
Thomann KH and Dul MW
- Subjects
- Humans, Nervous System Diseases etiology, Gait physiology, Nervous System Diseases physiopathology
- Abstract
For most people, walking is an automatic, unconscious activity, characteristic of each individual. Patterns of gait can be reflective of a person's body structure, occupation, and personality, as well as health status. Most parents who watch an infant beginning to walk realize that locomotion is a highly complex, learned process. Years of training and practice are necessary for the sensory-motor system to become adept at automatically generating the motor commands necessary to permit walking without conscious effort. The characteristic adult pattern of walking does not emerge until up to 7 to 9 years of age, after the neuromusculoskeletal systems have undergone constant modification and development of improved neural controls. Important information pertinent to the patient's health status can be obtained by observing his or her manner of walking. This article will review abnormal gait patterns due to nervous system dysfunction. To help understand abnormal gaits, a brief review of the underlying components of walking is necessary.
- Published
- 1996
25. Bone scintigraphy: a review of the procedure and its applications.
- Author
-
Thomann KH and Dul MW
- Subjects
- Aged, Aged, 80 and over, Bone Neoplasms diagnostic imaging, Bone Neoplasms secondary, Bone and Bones abnormalities, Humans, Male, Organotechnetium Compounds, Osteitis Deformans complications, Prostatic Neoplasms pathology, Bone and Bones diagnostic imaging, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Bone scintigraphy (bone scanning) is a sensitive diagnostic tool used to detect the presence and extent of primary and secondary bone disease. Unlike X-rays, MRI, and CT scans, which focus primarily on structural anatomy, bone scans depict the dynamic physiologic response of bone to an insult. We review bone scanning principles, their indication in eye care, and demonstrations of their use in eye involvement from both primary and metastatic bone disease.
- Published
- 1994
- Full Text
- View/download PDF
26. Co-management of patients with hypertension.
- Author
-
Dul MW
- Subjects
- Humans, Hypertension physiopathology, Primary Health Care, Hypertension therapy, Optometry, Patient Care Team
- Abstract
Information provided by doctors of optometry to the primary care providers of patients with hypertension provides one of the few objective means of assessing the status of these patients. The optometrist may also be the first to suspect primary or secondary hypertension in the course of a comprehensive eye examination. In this paper the pathophysiology of essential, malignant, and secondary hypertension is reviewed. The treatment and management of the systemic and ocular effects of hypertension are discussed along with the pivotal role that doctors of optometry play in co-managing patients with hypertension.
- Published
- 1994
27. The optometric assessment of neurologic function.
- Author
-
Thomann KH and Dul MW
- Subjects
- Blinking, Cranial Nerve Diseases diagnosis, Humans, Motor Activity, Motor Skills, Reflex, Babinski, Reflex, Stretch, Sensory Thresholds, Eye Diseases diagnosis, Nervous System Diseases diagnosis, Optometry
- Abstract
Background: As a direct extension of the nervous system, the eye may be involved in a number of nervous system diseases and disorders., Methods: The previous ophthalmic and medical literature was evaluated and organized into an orderly review of the literature with recommendations for the examination of patients with neurologic dysfunctions., Results: Many of the appropriate tests for the assessment of neurologic function can be readily performed by optometrists in the clinical setting. CONCLUSIONS. The screening of neurologic function by optometrists is important in many ways. The optometrist can gain significant insight in the ocular and systemic diagnoses associated with neurologic disease by utilizing the appropriate clinical tests and as a result then communicate more effectively with neurologists and other health care practitioners.
- Published
- 1993
28. Optic nerve trauma.
- Author
-
Dul MW
- Subjects
- Humans, Infant, Newborn, Optic Atrophy diagnosis, Optic Atrophy etiology, Optic Atrophy therapy, Optic Nerve anatomy & histology, Retinal Hemorrhage etiology, Subarachnoid Hemorrhage diagnosis, Subarachnoid Hemorrhage etiology, Vitreous Hemorrhage etiology, Optic Nerve Injuries
- Abstract
Trauma to the optic nerve may be direct, such as from a penetrating object, or indirect, which may result despite lack of direct contact of an object with the nerve. Although indirect injury initially causes no change in the appearance of the nerve head, within a matter of weeks optic atrophy will be manifest. The pathophysiology of nerve damage is incompletely understood. Management is controversial; steroid therapy has been advocated, as has surgical decompression of the nerve. Indirect injuries affecting the optic nerve may also result from torsional rotation of the globe (avulsion) and from subdural or subarachnoid hemorrhage (Terson's syndrome). There is no treatment for optic nerve avulsion; the unaffected eye should be protected with appropriate eyewear. Hemorrhaging in the retina and vitreous in Terson's syndrome should be monitored for resolution and risk of retinal detachment. Computed tomography may be necessary if subarachnoid or intracranial hemorrhages are suspected.
- Published
- 1993
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.