30 results on '"Dara RC"'
Search Results
2. Safety assessment of RhD-positive red cell transfusion in RhD-negative liver-transplant recipients: Single-centre report from India.
- Author
-
Tiwari AK, Arora D, Aggarwal G, Dara RC, Bhardwaj G, Sharma J, Vohra V, and Soin AS
- Subjects
- Erythrocytes, Humans, India epidemiology, Isoantibodies, Liver, Living Donors, Retrospective Studies, Transplant Recipients, Liver Transplantation adverse effects
- Abstract
Background & Objectives: The number of blood components required during a liver-transplant surgery is significant. It is challenging for blood transfusion services to provide the required RhD-negative red blood cells (RBCs) for recipients during the peri-operative period. This retrospective study presents safety data of transfusing RhD-positive RBCs in RhD-negative living donor liver-transplant (LDLT) recipients during the peri-operative period with six-month follow up for risk of developing alloantibodies., Methods: All RhD-negative patients who underwent LDLT and were transfused ABO-compatible but RhD-positive RBC units between January 2012 and May 2018 were included in the study. Twenty one RhD-negative patients who received a total of 167 RhD-positive RBCs peri-operatively were chosen for alloantibody screening. All the patients were started on triple immunosuppression drugs as per the standard hospital protocol. Blood grouping, cross-match and antibody screening were done by column agglutination technique., Results: Post-transplant antibody screen (weekly for 12 wk) was negative, and none of the patients developed anti-D alloantibodies till their last follow up (mean 21 months)., Interpretation & Conclusions: Our observations suggest that it may be safe to use RhD-positive RBCs peri-operatively in RhD-negative LDLT recipients with low risk of alloimmunization., Competing Interests: None
- Published
- 2020
- Full Text
- View/download PDF
3. Severe drug-induced immune hemolysis due to ceftriaxone.
- Author
-
Dara RC, Sharma R, and Bhardwaj H
- Abstract
Drug-induced immune hemolytic anemia (DIIHA) is a rare condition that results primarily due to drug-induced antibodies, either drug dependent or drug independent. For its diagnosis, specialized immunohematology laboratory is often required for performing complex serological tests. The exact incidence of DIIHA is not known, but as per data published by Garratty, the incidence of DIIHA is estimated to be one in million population.
[1] There are many drugs which are implicated in causing DIIHA ranging from antimicrobials, antineoplastics to anti-inflammatory drugs. Among antimicrobials, cephalosporins are commonly reported to cause hemolytic anemia.[2] In this report, we present a life-threatening hemolytic reaction to cephalosporin (ceftriaxone) in a 15-year-old child, which was diagnosed and managed in a timely manner. Our patient was suddenly deteriorated after two doses of intravenous ceftriaxone, with increase in pallor, fatigue, and frank hematuria. Repeat laboratory investigations showed signs of hemolysis, presence of schistocytes, raised lactic dehydrogenase, and indirect bilirubin. Reticulocyte count was 3.4%. Direct antiglobulin test was strong positive (4+) with IgG and C3d positive. Testing for drug-dependent antibody confirmed the presence of ceftriaxone-dependent antibody. Drug was stopped immediately. There was a rapid improvement in patient's general condition after discontinuation of drug. Laboratory parameters were improved after 48 h, and the patient was stable with no further drop in hemoglobin and hemolytic episodes. We suggest the need for proper immunohematological services to diagnose and solve such complex cases promptly., Competing Interests: There are no conflicts of interest., (Copyright: © 2020 Asian Journal of Transfusion Science.)- Published
- 2020
- Full Text
- View/download PDF
4. Prophylactic administration of oral calcium carbonate during plateletpheresis: A bicentric prospective study.
- Author
-
Pandey PK, Tiwari A, Agarwal N, and Dara RC
- Abstract
Background: Administration of anticoagulant citrate and dextrose (ACD-A) chelates ionized calcium in blood and causes hypocalcemia in plateletpheresis donors. The aim of the study was to observe the effects of oral calcium (Ca) supplementation during plateletpheresis on various parameters related to calcium metabolism., Materials and Methods: This study was performed between January 2014 and December 2014 on 200 plateletpheresis donors. They were divided into two groups. In group A donors (n=100), no prophylactic oral calcium supplementation was given. In group B (n=100) donors, 2000 mg of calcium was given one hour before the start of the procedure, 500 mg was given at the start of the procedure and 500 mg calcium was given just before the end of procedure. Biochemical parameters like serum total calcium (T Ca), serum total magnesium (T Mg) and ionized calcium level (iCa) were measured before and after the procedure. Relative risk of citrate toxicity was measured between the two groups., Results: There was a significant fall in total calcium (pre 9.02 mg/dl, post 8.23 mg/dl,), ionized calcium level (pre 1.14 mmol/L, post 0.91 mmol/L) and total magnesium (pre 1.92 mg/dl, post 1.79 mg/dl) amongst the donors who did not receive prophylactic calcium supplementation. Despite calcium intake, in prophylactic calcium intake group, we did observe a significant drop in total magnesium (pre 2.04 mg/dl, post 1.94 mg/dl) and ionized calcium level (pre 1.25 mmol/L, post 1.12 mmol/L, p <0.01). We did observe a drop in total calcium level, however, this observation was not statistically significant. The risk (RR=5.44) of citrate toxicity was higher among group A donors., Conclusion: Prophylactic oral calcium carbonate supplementation would help in to reduce the risk of citrate toxicity. Therefore, we suggest for prophylactic oral administration of 3000 mg elemental calcium carbonate in three divided doses to make PP procedures uneventful., Competing Interests: There are no conflicts of interest., (Copyright: © 2020 Asian Journal of Transfusion Science.)
- Published
- 2020
- Full Text
- View/download PDF
5. Comparison of a column agglutination technology-based automated immunohematology analyzer and a semiautomated system in pretransfusion testing.
- Author
-
Dara RC, Tiwari AK, Mitra S, Acharya D, Aggarwal G, Arora D, and Bhardwaj G
- Abstract
Introduction: Semi-automated equipment using Column agglutination technology (CAT) is widely used where centrifugation and incubation are automated but substantial amount of the work is still executed manually. Larger laboratories are moving towards automation to eliminate errors, reducing exposure to bio-hazardous samples, assuring traceability, reliability, turnaround time (TAT) and throughput. Moving towards automation and greater reliability, we therefore, decided to install an automated immunohematological (IH) analyzer "Vision". In this study we evaluated reliability and performance before clearing "Vision" for routine use., Materials and Methods: Study was conducted in the Department of Transfusion-Medicine. The primary objective was to assess the reliability of results and compare with routine use semi-automated BIOVUE system (Reference system). Secondary objective was to evaluate the performance (TAT and throughput) of the Vision to handle routine and emergency workload., Results: Total of 1276 known samples were used to assess 2640 pre-transfusion tests (1229 ABO/Rh D typing; 1229 antibody screening; 54 antibody identification; 86 crossmatch and 42 DAT). All 1229 ABO Rh typing results were concordant between the two systems. Overall agreement between the Vision IH analyzer and reference system for ABO Rh typing was 99.95%. All antibody screening, crossmatch and DAT results were concordant between the two systems. TAT of Vision was substantially shorter than the reference system for all test profiles., Conclusion: Based on study results, Vision was approved for routine use in laboratory. It was found to be reliable with considerably shorter TAT and capable of handling high throughput of immunohematological tests., Competing Interests: There are no conflicts of interest., (Copyright: © 2019 Asian Journal of Transfusion Science.)
- Published
- 2019
- Full Text
- View/download PDF
6. Successful treatment of Sezary syndrome with extracorporeal photopheresis - The first attempt in India.
- Author
-
Tiwari AK, Arora D, Dhiman P, Kapoor S, Aggarwal G, Dara RC, and Vaid A
- Abstract
Sezary syndrome (SS) is more aggressive leukemic variant of cutaneous T-cell lymphoma in which a significant number of circulating malignant (Sezary) cells are observed in peripheral blood. Although single-agent or combination chemotherapy regimens have produced moderately high response rates in patients with advanced-stage SS, these responses are invariably not durable. Extracorporeal photopheresis (ECP) is recommended as an immunomodulator treatment, offering better life quality for patient. We would like to present the first SS case treated successfully with low-dose methotrexate and ECP in India. A 50-year-old male presented with rash and severe pruritus all over the body for 2 years. He had received various treatment regimens but without any symptomatic improvement. He underwent detailed examination and diagnosis of SS was established. Peripheral smear revealed total leukocyte count of 14900/μl with 55% cells reported as Sezary cells. Contrast-enhanced computerized tomography revealed few insignificant (<1.5 cm) bilateral nodes in the axillary and inguinal region. The patient's disease stage was determined IVA1, and grade was T4N0M0B2. He received six cycles of CHOP, which led to a short-term remission of <3 months, and he was started on single-agent methotrexate along with skin supportive treatment. He did not respond to low-dose methotrexate alone, and therefore, ECP was added to treatment regimen. This was possibly the first such treatment for SS patient in India. The patient had very good response after six cycles of ECP with pruritus and itching diminishing and scaly lesions down to <10% of body surface area. There was regrowth of hair all over affected area. Sezary cell counts also came down to 35%. The patient continues to do well post-ECP, with single-agent gemcitabine. ECP either as monotherapy or in combination with other immunotherapies offers a good treatment option to otherwise resistant cases of SS., Competing Interests: There are no conflicts of interest.
- Published
- 2019
- Full Text
- View/download PDF
7. Applying newer parameter Ret-He (reticulocyte haemoglobin equivalent) to assess latent iron deficiency (LID) in blood donors-study at a tertiary care hospital in India.
- Author
-
Tiwari AK, Bhardwaj G, Arora D, Aggarwal G, Pabbi S, Dara RC, Sachdev R, Raizada A, and Sethi M
- Subjects
- Adolescent, Adult, Female, Hematologic Tests standards, Hemoglobins analysis, Humans, India, Male, Middle Aged, Random Allocation, Tertiary Care Centers, Anemia, Iron-Deficiency blood, Blood Donors, Hematologic Tests methods, Hemoglobins standards, Reticulocytes metabolism
- Abstract
Background: It is important to detect Latent Iron Deficiency (LID) to prevent development of an overt iron deficiency anemia. Early detection is difficult by using conventional hematological and biochemical parameters. Soluble transferrin receptor (sTfR) is presently the gold standard for diagnosing LID. We evaluated the utility of Reticulocyte Hemoglobin Equivalent (Ret-He), a newer hematological parameter, to predict LID in blood donors as compared to sTfR., Methods: This was a randomized prospective study performed on 501 donor samples over a period of three-months. All donors were included after administering medical history questionnaire and a brief physical examination in accordance with national guidelines (Hb ≥12.5). Additional samples were collected during donation according to the institutional standard operating procedure (SOP). All hemograms were performed on the Sysmex XE-2100 analyzer which included Ret-He. sTfR was measured in batch assays by ELISA (Biovendor, Czech Republic). Ret He <28 pg and sTfR≥3μg/ml were used to diagnose LID. Serum Iron, Total Iron Binding Capacity (TIBC) and Serum Ferritin were also measured simultaneously., Results: Of the 501 blood donors, sTfR and Ret-He detected LID in 148 and 135 donors respectively. In comparison to sTfR, Ret-He had sensitivity of 92.7%, a specificity of 97.16%, PPV of 93.1% and NPV of 96.3%. Serum Ferritin, TIBC and serum Iron had comparatively lower sensitivity of 87.16%, 79.7% and 77.7% respectively., Conclusion: Ret-He can be used as a routine screening test to detect LID in blood donors. This could provide an opportunity to make appropriate and timely interventions like dietary changes or drug supplementation., (© 2018 International Society of Blood Transfusion.)
- Published
- 2018
- Full Text
- View/download PDF
8. Notification and counselling of hepatitis positive blood donors, their immediate emotional response, contact-testing and their follow-up: Study from a tertiary care hospital!
- Author
-
Tiwari AK, Bhardwaj G, Dara RC, Arora D, Aggarwal G, Bhargava R, and Madan K
- Subjects
- Adolescent, Adult, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Risk Factors, Tertiary Care Centers, Young Adult, Blood Donors statistics & numerical data, Counseling methods, Hepacivirus pathogenicity, Hepatitis C transmission
- Abstract
Introduction: Post-donation counselling informs donors of unusual test results. Timely notification and counselling regarding their Transfusion Transmitted Infection (TTI) status is necessary for early clinical intervention in the donor and reducing risk of transmission. We share our experience with respect to Hepatitis B (HBV) and Hepatitis C (HCV) positive donors who were counselled and followed-up for clinical outcome., Materials and Methods: It was prospective 2-year study in TTI positive blood donors. Confirmed positive HBV/ HCV donors were notified to attend the donor-clinic or to visit local hepatologist for further management. At donor clinic, donor's immediate emotional response was observed; donors were offered contact-testing, associated risk factors were noted, counselled, referred to hepatologist, treated and followed-up for clinical outcome., Results: Of 481 donors (0.91%) confirmed positives, 351 were contacted telephonically; 280 promised to attend donor clinic and 71 were referred to their local hepatologist. 145 donors attended the donor clinic, eventually. Most common immediate emotional response noted were 'feeling of fear' (55.2%) and 'disbelief' (35.2%). Most common associated risk factor was history of medical treatment/ injections without knowledge of sterilisation. Five donors availed contact testing and four (spouses in all four cases) came out positive. Of 98 donors contacted post-counselling; 89 went to hepatologist. No medication was advised to seven donors (low viral load), 59 donors completed treatment course and 23 donors were undergoing treatment at time of follow-up. Nine donors opted for alternative treatment or "no treatment"., Conclusion: Donor-clinic proved beneficial to substantial number of donors and their families., (Copyright © 2018 Elsevier Ltd. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
9. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.
- Author
-
Tiwari AK, Setya D, Aggarwal G, Arora D, Dara RC, Ratan A, Bhardwaj G, and Acharya DP
- Abstract
Background: Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion., Materials and Methods: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff., Results: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique., Conclusion: Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique., Competing Interests: There are no conflicts of interest.
- Published
- 2018
- Full Text
- View/download PDF
10. Advantages of type and screen policy: Perspective from a developing country!
- Author
-
Aggarwal G, Tiwari AK, Arora D, Dara RC, Acharya DP, Bhardwaj G, and Sharma J
- Abstract
Introduction: The authors' center recently changed their pretransfusion testing protocol from "conventional" type and screen (TS) with anti-human globulin (AHG) crossmatch (Policy A) to TS with immediate-spin (IS) crossmatch (Policy B). Red blood cell (RBC) units were issued after compatible IS crossmatch as and when required instead of AHG crossmatch. This study was conducted to compare the effects of change of policy from A to B over 1-year period on crossmatch-to-transfusion (C/T) ratio, RBC issue turnaround time (TAT), outdating of RBC, man-hours consumption, and monetary savings., Materials and Methods: This was a comparative, prospective study conducted by the Department of Transfusion Medicine of a tertiary hospital-based blood bank in Northern India. The Policy B was implemented in the department from January 2014. Relevant retrospective data for comparison of the previous 1 year, when Policy A was practiced, were derived from hospital information system., Results: 23909 and 24724 RBC units transfused to patients admitted to the hospital during respective 1-year period of practice for Policy A and B. There was significant reduction in C/T ratio (1.94 vs. 1.01) and RBC issue TAT (79 vs. 65 min) with Policy B. Expiry due to outdating reduced (37 vs. zero) along with man-hours (16% reduction) and monetary (33% reduction) savings., Conclusion: Use of 'TS with IS crossmatch' policy provides multiple advantages to all the stakeholders; blood banker, clinician, patient, and the hospital management., Competing Interests: There are no conflicts of interest.
- Published
- 2018
- Full Text
- View/download PDF
11. Changing Trends in Therapeutic Plasmapheresis: An Indian Perspective.
- Author
-
Tiwari AK, Bhardwaj G, Aggarwal G, Arora D, Dara RC, Acharya DP, Gayam S, and Choudhuri J
- Subjects
- Adolescent, Adult, Aged, Child, Child, Preschool, Female, Humans, India, Infant, Male, Middle Aged, Plasmapheresis methods, Plasmapheresis statistics & numerical data, Retrospective Studies, Tertiary Care Centers, Treatment Outcome, Young Adult, Plasmapheresis trends, Practice Guidelines as Topic
- Abstract
Indications for therapeutic apheresis (TA) are dynamic; they keep changing and expanding because of introduction of newer treatment modalities and accumulating evidence in the form of case-reports, case-series and original articles. We evaluated our therapeutic plasmapheresis (TP) data and compared this data with an earlier published Indian report for indications, frequency, response rate and adverse reactions. We conducted a retrospective analysis of all TP procedures performed from January 2014 to June 2016 in department of Transfusion Medicine at a tertiary care hospital. All TP procedures performed for various clinical disorders including neurological, hematological, renal, hepatic and rheumatologic indications were included in the study. Analysis was performed with respect to demography, procedure details and response. 187 patients (118 Males and 69 females) underwent 683 TP procedures during study period. According to 2013 ASFA guidelines, 99, 59 and 29 patients belonged to category I, II and III respectively. In comparison with the earlier report, the number of patients and procedures have increased, indications have changed, response rate is comparable, and the frequency of adverse reactions have decreased. In the last decade there has been increase in number and spectrum of indications for therapeutic apheresis and frequency of procedures. The response rate and safety of these procedures have also improved., (© 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.)
- Published
- 2017
- Full Text
- View/download PDF
12. Comparison of two algorithms to confirm and discriminate samples initially reactive for nucleic acid amplification tests.
- Author
-
Tiwari AK, Dara RC, Arora D, Aggarwal G, Rawat G, and Raina V
- Abstract
Background: Blood centers in India have published individual donor nucleic acid testing (ID-NAT) data based on an algorithm (Algorithm A) where serologically negative, NAT reactive sample was subsequently tested with discriminatory NAT (d-NAT), and on the basis of d-NAT, initial reactive samples were classified as "NAT yield" or inconclusive. We followed Algorithm B based on replicate testing and Ultrio Plus assay and compared the results with Algorithm A with Ultrio assay., Materials and Methods: Results of ID-NAT using two algorithms were analyzed., Results: A total of 88,583 (31,844 with Algorithm A and 56,739 with Algorithm B) samples were tested. Among serology nonreactive donations, NAT inconclusive results came down from 95.2% in Algorithm A to 73.1% in Algorithm B ( P = 0.0001). Discriminated yield (DY) rate went up from 4.7% in Algorithm A to 21.9% in Algorithm B ( P = 0.001)., Conclusion: The study data suggest that replicate testing strategy and Ultrio Plus reduce the number of "inconclusive results" seen with earlier commonly used algorithm. We recommend a replicate testing strategy in ID-NAT testing since it will increase the DY and will eliminate the unnecessary discriminatory tests., Competing Interests: There are no conflicts of interest.
- Published
- 2017
- Full Text
- View/download PDF
13. Co-infection of blood borne viruses in blood donors: A cross-sectional study from North India.
- Author
-
Dara RC, Tiwari AK, Arora D, Aggarwal G, Rawat GS, Sharma J, Acharya DP, and Bhardwaj G
- Subjects
- Adolescent, Adult, Coinfection, Cross-Sectional Studies, Female, Humans, India, Male, Middle Aged, Retrospective Studies, Young Adult, Blood Donors, HIV Infections epidemiology, Hepatitis B epidemiology, Hepatitis C epidemiology
- Abstract
Background: There are several studies on prevalence of individual infectious disease markers (mono-infection) in donors but none on prevalence of coinfection. Co-infection is significant as it leads to accelerated disease progression. We, therefore, evaluated the prevalence of co-infection among blood donors., Materials and Methods: The cross-sectional analysis was conducted in blood donors. All donors were tested for anti-HIV I and II, HBsAg, anti-HBC IgM, anti-HCV, Malaria and syphilis by chemiluminescence and ID-NAT assay. All reactive donor samples were confirmed by using confirmatory assays. Donors were grouped as mono-infected and co-infected. The student t-test was used for comparison., Results: During the study period, a total of 106,238 blood donors were tested. Mean age of donors was 34.2 years and 94.2% of blood donors were males. 1776 (1.67%) donor samples were confirmed serologically reactive. 1714 (1.61%) samples were reactive for single marker (mono-infected) while 62 (0.05%) donors' samples exhibited co-infection. 18 donors were positive for HBV+HCV followed by HIV +syphilis (14)., Conclusion: We report for the first time the prevalence of different co-infection patterns in blood donors. Co-infection influence the disease progression; it would be important to investigate the co-infection prevalence in larger sample size., (Copyright © 2017 Elsevier Ltd. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
14. Successful Renal Transplantation Across HLA Barrier: Report from India.
- Author
-
Aggarwal G, Tiwari AK, Dorwal P, Chauhan R, Arora D, Dara RC, and Kher V
- Abstract
Organ donors are sometimes found "unsuitable" due to the presence of donor-specific anti-HLA antibodies in the recipient. In recent years, improved desensitization protocols have successfully helped to overcome HLA incompatibility hurdle. We present three cases where optimum desensitization was achieved in patients with the donor-specific anti-HLA antibody (DSA) leading to successful renal transplantation. All patient-donor pair underwent HLA typing, complement dependent cytotoxicity crossmatch (CDC-XM), flow cytometry XM (FC-XM), and panel reactive antibody. If any of the three tests was positive, single antigen bead assay was performed to determine the specificity of the anti-HLA antibody (s). Patients with DSA were offered organ-swap or anti-HLA antibody desensitization followed by transplantation. Desensitization protocol consisted of single dose rituximab and cascade plasmapheresis (CP) along with standard triple immunosuppression. The target DSA mean fluorescence index (MFI) was <500, along with negative CDC-XM and FC-XM for both T- and B-cells. Three patients with anti-HLA DSA, who did not find a suitable match in organ swap program, consented to anti-HLA antibody desensitization, followed by transplantation. Mean pre-desensitization antibody MFI was 1740 (1422-2280). Mean number of CP required to achieve the target MFI was 2.3 (2-3). All the three patients are on regular follow-up and have normal renal function test at a mean follow-up of 8 months. This report underlines successful application of desensitization protocol leading to successful HLA-antibody incompatible renal transplants and their continued normal renal functions., Competing Interests: There are no conflicts of interest.
- Published
- 2017
- Full Text
- View/download PDF
15. Post-donation telephonic interview of blood donors providing an insight into delayed adverse reactions: First attempt in India.
- Author
-
Tiwari AK, Aggarwal G, Dara RC, Arora D, Srivastava K, and Raina V
- Subjects
- Adult, Female, Humans, India, Male, Prospective Studies, Blood Donors, Interviews as Topic, Surveys and Questionnaires
- Abstract
Background: Blood donor experiences both immediate adverse reactions (IAR) and delayed adverse reactions (DAR). With limited published data available on the incidence of DAR, a study was conducted to estimate incidence and profile of DAR through telephonic interview., Materials and Methods: Study was conducted over a 45-day period for consecutive volunteer whole blood donations at tertiary care hospital. Donors were divided into first-time, repeat and regular and were monitored for IAR. They were given written copy of post-donation advice. Donors were contacted telephonically three weeks post-donation and enquired about general wellbeing and specific DAR in accordance with a standard n international (International Society of Blood Transfusion) standard format., Results: Donors participated in the study of which 1.6% donors experienced an IAR. Much larger number reported DAR (10.3% vs.1.6% p<0.0001). Further, DAR was presented as a variegated profile with bruise, painful arms and fatigue being the commonest. DARs were more common in females than males (25% vs. 10.3%, p<0.02). Localized DAR like bruise and painful arms were more common in younger donors (age <50 years) whereas systemic DAR like fatigue was common in older donors (>50 years). First time (12.3%) and repeat donors (13.5%) had similar frequency of DAR but were lower among regular donors (6.7%)., Conclusion: DARs are more common than IAR and are of different profile. Post-donation interview has provided an insight into donor experiences and can be used as a valuable tool in donor hemovigilance., (Copyright © 2016 Elsevier Ltd. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
16. Applications of selected cells in immunohematology in a developing country: case studies.
- Author
-
Dara RC, Tiwari AK, Arora D, Mitra S, Aggarwal G, Acharya DP, and Bhardwaj G
- Subjects
- Adolescent, Adult, Developing Countries, Female, Humans, India, Isoantibodies immunology, Male, Middle Aged, Blood Group Incompatibility blood, Blood Grouping and Crossmatching methods, Erythrocytes immunology, Isoantibodies analysis
- Abstract
Conclusions: When an antibody is detected, its specificity should be determined and its likely clinical significance should be assessed. When one antibody has been identified, it becomes necessary to confirm the presence of additional significant antibodies to ensure that compatible blood is provided to the patient. To perform this confirmation, specific reagent red blood cells (RBCs) are selected; these are called selected cells. Though the most common use of selected cells is for antibody confirmation, they can also be used for several other immunohematologic applications. In a developing country like India, the performance of antibody screening for unexpected antibodies on a routine basis is a comparatively new phenomenon, and those laboratories performing advanced immunohematologic testing would need to use selected cells to arrive at an accurate conclusion. This report defines selected cells and enumerates sources of these RBCs. Detailed immunohematologic applications are discussed with applicable case studies.
- Published
- 2017
17. Alloimmunization in autoimmune hemolytic anemia patient: The differential adsorption approach.
- Author
-
Dara RC, Tiwari AK, Arora D, Mitra S, Acharya DP, Aggarwal G, and Sharma J
- Abstract
Patients of β-thalassemia major are dependent on regular blood transfusions for their entire lifetime. Development of antibodies against red blood cell (RBC) antigen which may be alloantibody or autoantibody, several times as a result of frequent red cell component transfusions, further complicates the subsequent transfusion therapy. Among the autoantibodies, warm-reactive autoantibodies are commoner and interfere in the pretransfusion testing. These RBC autoantibodies present in patient's serum potentially react with all the cells of antibody identification panel giving "pan-reactive" picture and making alloantibody identification complex. In this report, we present our approach in a thalassemia patient who presented with warm-type autoimmune hemolytic anemia, low hemoglobin of 5.8 g/dl, and three significant alloantibodies (anti-D, anti-S, and anti-Jk
b ) which were masked by pan-reactive warm autoantibody(s). Differential adsorption was used to unmask underlying alloantibodies. We suggest that differential adsorption procedure is an effective and efficient method for autoantibody adsorption, detection, and identification of masked alloantibody(s), especially in patients with low hemoglobin and history of recent blood transfusion., Competing Interests: There are no conflicts of interest.- Published
- 2017
- Full Text
- View/download PDF
18. First Indian study to establish safety of immediate-spin crossmatch for red blood cell transfusion in antibody screen-negative recipients.
- Author
-
Tiwari AK, Aggarwal G, Dara RC, Arora D, Gupta GK, and Raina V
- Abstract
Background and Objectives: The US Food and Drug Administration and American Association of Blood Banks approved the type and screen approach in 1980s, long after antibody screen (AS) was introduced in 1950s. The present study omits conventional anti-human globulin (AHG) crossmatch and replaces it with immediate-spin (IS) crossmatch as part of pretransfusion testing in AS-negative patients to study the safety and effectiveness of IS crossmatch in recipients., Materials and Methods: This prospective longitudinal study was conducted on over 5000 red cell units transfused to AS-negative patients admitted to the hospital. Pretransfusion testing comprised blood grouping and AS followed by IS crossmatch, at the time of issue of red cell unit. The patients were transfused IS compatible red cell units. AHG crossmatch was performed posttransfusion for all red cell units. Any incompatible AHG crossmatch was followed up as suspected transfusion reaction., Results: A total of 5023 red cell units were transfused to 2402 patients with negative AS. 99.7% IS compatible red cell units were also compatible on posttransfusion AHG crossmatch. Anti-P1 alloantibody was identified in one patient who was transfused two IS crossmatch compatible units but later both units were incompatible on AHG crossmatch. There was no clinical or serological sign of hemolysis in the patient., Conclusion: In AS-negative patients, IS crossmatch is as safe as conventional AHG crossmatch and can, therefore, replace conventional AHG crossmatch protocol., Competing Interests: There are no conflicts of interest.
- Published
- 2017
- Full Text
- View/download PDF
19. A Randomized Control Study to Evaluate Effects of Short-term Oral Iron Supplementation in Regular Voluntary Blood Donors.
- Author
-
Dara RC, Marwaha N, Khetan D, and Patidar GK
- Abstract
Regular blood donation can lead to iron deficiency anaemia. Early recognition and reversal of excessive iron loss by iron supplementation may avoid symptomatic iron store depletion in blood donors. The aim of this study was to assess the efficacy of iron supplementation in maintaining the iron stores of voluntary blood donors. A total of 200 regular volunteers who donated twice in previous year were randomly divided into two groups. Iron: oral iron supplementation tablets of elemental iron as ferrous fumarate. Placebo group: glucose containing capsules, to be taken once daily for 21 days after one unit of blood donation. Their hemogram, serum ferritin, red cell indices and red cell distribution width were determined at baseline and after 1 month and at the time of next blood donation. Out of 200 volunteers enrolled 98 were assigned to iron group and rest 102 into placebo group. Total of 37 % donors dropped out, yielding a dropout rate of 35 % in iron group and 39 % in the placebo group. The haemoglobin and ferritin levels showed significant improvement in iron group compared to placebo group (p < 0.05). Three weeks of oral iron therapy (98.6 mg elemental iron/day) was able to maintain iron stores at 1 month after donation but was not sufficient to sustain the iron stores over a period of 3 months. Thus there is need to evaluate increased dosage or duration of iron supplementation in maintaining the iron stores.
- Published
- 2016
- Full Text
- View/download PDF
20. Newly established stem cell transplant program: 100 days follow-up of patients and its comparison with published Indian literature.
- Author
-
Tiwari AK, Arora D, Dara RC, Dorwal P, Sood N, Misra R, Gupta SK, Raina V, and Vaid AK
- Abstract
Background: Hematopoietic progenitor stem cell transplantation (HPSCT) is used as a standard treatment option to improve outcome in hematological and nonhematological disorders. It is important for new HPSCT program to look at its patient outcome data and compare it with the published data to evaluate the efficacy of program., Aims: The aim was to compile and collate the patient outcome data of HPSCT and compare with published reports., Materials and Methods: Patient demographics, indications, stem cell harvest by apheresis, dose collected, infusion, engraftment, and follow-up data were collected from hospital information system from 2010 to 2013 in a tertiary care hospital. HPSCs were mobilized with granulocyte colony-stimulating factor, and harvests were done on the 5(th) day. Engraftment was decided for neutrophil when counts were 0.5 × 10(9)/L and for platelets when counts were 20 × 10(9)/L on two consecutive days without any transfusion support., Results: There were 133 harvests for 95 patients with various disorders; multiple myeloma was most common in autologous and acute lymphoblastic leukemia in allogeneic group. One hundred harvests were done for autologous and 33 for allogeneic HPSCT. In autologous group, of 66 patients, 60 (90.9%) received stem cell infusion at median dose of 4.63 × 10(6) CD34(+) cells/kg. Similarly, in allogeneic group, of 29 patients, 27 (93.10%) received infusion at median dose of 5.8 × 10(6) CD34(+) cells/kg. 58 (96.9%) patients and 25 (92.6%) engrafted in autologous and allogeneic group, respectively. The median time for neutrophils engraftment was 11 days in autologous group and 12 days in allogeneic group. The median time for platelet engraftment was 11.5 days in autologous group and 13 days in allogeneic group. The 100-day survival rate was 95% (n = 57) in autologous group and 77.8% (n = 21) in allogeneic group., Conclusion: This data analysis shows reasonably good results of HPSCTs with majority of patients surviving at 100-day follow-up.
- Published
- 2016
- Full Text
- View/download PDF
21. Confirmation and follow up of initial "NAT yields": Prospective study from a tertiary healthcare center in India.
- Author
-
Pandey P, Tiwari AK, Dara RC, Rawat GS, Negi A, and Raina V
- Subjects
- Female, Follow-Up Studies, Humans, India, Male, Prospective Studies, Tertiary Care Centers, Blood Donors, Donor Selection methods, HIV Infections blood, HIV-1, Hepacivirus, Hepatitis B blood, Hepatitis B virus, Hepatitis C blood, Nucleic Acid Amplification Techniques
- Abstract
Background: In India variable rate of "NAT yield" has been demonstrated in several published reports. This study was performed with the objective to know the rate of "true NAT yield" in blood donors by confirmation with supplementary tests and follow up of initial "NAT yield" donors., Materials and Methods: A total of 48,441 blood donors were tested for HIV, HBV and HCV with enhanced chemiluminescence and ID-NAT. To know the true NAT yield status confirmation of NAT yield donors was done as with an array of serological tests, repeat ID-NAT and alternate NAT., Results: The cumulative initial "NAT yield" rate was 1:4404 (11/48,441). Seven of 11 initial "NAT yields" were for hepatitis B whereas two each were in HIV and HCV. Among the 11 "NAT-yield" donors, eight donors were followed-up for confirmation. Out of these eight donors only 4 were found to be true HBV NAT yields. Out of four true NAT yields two were window period donations while the other two were occult hepatitis B infection with anti-HBcore total positive., Conclusion: Our findings suggest that all "initial NAT yields" may not be "true NAT yields". We would also like to suggest that to demonstrate the true "NAT yield" status supplementary tests and donor follow up are important to differentiate true NAT yields., (Copyright © 2015 Elsevier Ltd. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
22. Successful tandem transplant in a young aplastic anemia patient from a small-weight 11-month-old sibling donor.
- Author
-
Arora D, Tiwari AK, Dara RC, Misra R, Aggarwal G, Acharya DP, and Raina V
- Subjects
- Follow-Up Studies, Humans, Infant, Male, Treatment Outcome, Anemia, Aplastic therapy, Body Weight, Bone Marrow Transplantation, Peripheral Blood Stem Cell Transplantation, Siblings, Tissue Donors
- Abstract
Five years five month old male child diagnosed with aplastic anemia required blood and platelet support regularly. He was advised bone marrow transplant (BMT) and had 6/6 match with a younger sibling (11 months old). He was admitted for planned BMT and was put on preparatory regimen five days prior to BMT. GCSF-primed bone marrow (BM) harvest was done from the donor, but the harvest was insufficient (1.05 × 10^6 /kg) and target dose of 4 million stem cells per kg could not be achieved. The BM harvest was infused into the patient and a repeat BM harvest was contemplated on next day. After careful evaluation of risks and benefits to the patient and the young donor, a decision to do a peripheral blood stem cell (PBSC) harvest was taken. The apheresis kit was blood primed to preclude possible hemodynamic imbalance in the donor considering low weight and young age. The entire harvest procedure (321 minutes) was uneventful with the donor remaining stable throughout. A dose of 2.40 million per kg of CD34+ cells was harvested and infused. Thus, a total dose of 3.45 million (1.05 BM and 2.4 PBSC) per kg was infused into the patient. Neutrophil and platelet engraftments and donor chimerism were achieved successfully with tandem BM-PBSC infusion and the patient continues to be disease free till 180 days follow up. This is possibly first published Indian report on BM-PBSC tandem transplant suggesting safety of PBSC harvests in small-weight young-age donor., (Copyright © 2016 Elsevier Ltd. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
23. Change in therapeutic apheresis practices: Role of continuing medical education (CME).
- Author
-
Tiwari AK, Dara RC, Pandey P, Arora D, Rawat G, and Raina V
- Subjects
- Adult, Blood Component Removal trends, Female, Humans, India, Male, Plasma Exchange trends, Practice Guidelines as Topic, Societies, Medical, United States, Blood Component Removal methods, Education, Medical, Continuing
- Abstract
Introduction: American society for apheresis (ASFA) publishes guidelines for therapeutic apheresis (TA) and physicians ordering TA procedures should be aware of the appropriate indications based on scientific evidence. Transfusion Medicine specialists (apheresis physicians) can steer physicians in right direction through CME on right indications, duration of therapy and replacement fluid. Therefore, authors reviewed, collated, and interpreted effect of formal CME interventions., Materials and Methods: Retrospective study was conducted in a large hospital in India. CME interventions to teach clinical and managerial aspects of TA were conducted in the first quarter of 2012. Sessions involved ASFA guidelines and recommendations for TA. Data was collected and changes in practice related to TA before (March 2010 to December 2011) and after (April 2012 to December 2013) the intervention was analyzed., Results: Seventy-three subjects participated in the interventions. Five hundred and eighty-nine TA procedures were performed during study period; 214 procedures in 49 patients before intervention and 375 procedures in 84 patients after intervention. After intervention there was significant improvement in indications of category I (38.7% vs. 64.3%; P = 0.004), category II (22.5% vs. 16.6%), category III (12.2% vs. 11.9%), and category IV (6.1% vs. 2.4%; P = 0.0001). Significant reduction was seen in procedures not belonging to any category from 20.5% to 4.8% (P = 0.002). Change in practices was also observed in context of duration of therapy and replacement fluid., Conclusion: CME intervention, based on the 2010 edition of ASFA guidelines for therapeutic apheresis appears to have had a positive impact on physicians TA practices., (© 2015 Wiley Periodicals, Inc.)
- Published
- 2016
- Full Text
- View/download PDF
24. A comprehensive serological and supplemental evaluation of hepatitis B "seroyield" blood donors: A cross-sectional study from a tertiary healthcare center in India.
- Author
-
Pandey P, Tiwari AK, Dara RC, Aggarwal G, Rawat G, and Raina V
- Abstract
Background: The present study addressed the interesting findings of supplemental evaluation of hepatitis B "seroyield" donors., Materials and Methods: Each blood donor sample was tested for anti-human immunodeficiency virus type I (HIV-I)/HIV type II (HIV-II), HBsAg, and anti-hepatitis C virus (HCV) antibody by enhanced chemiluminescence method and subjected to individual donor-nucleic acid testing (NAT) for HIV-I, hepatitis B virus (HBV), and HCV. NAT test was performed using the eSAS system, Procleix Ultrio Assay, Novartis Diagnostics, CA, US. Confirmation of HBsAg was done using HBsAg Confirmatory Kit (Ortho Clinical Diagnostics, Johnson & Johnson, USA) and viral load assessment was done using Cobas TaqMan real time-polymerase chain reaction (RT-PCR) assay (Roche Molecular Systems, Branchburg, NJ, USA). To provide information on the stage of infection, specimens were tested for anti-HBc total (IgG + IgM), anti-HBc IgM and HBeAg. HBeAg-negative samples were tested for anti-HBe antibody., Results: A total of 60 hepatitis B seroyield donors which showed mean initial sample/cutoff of 1.6 with enhanced chemiluminescence assay were investigated further for confirmation of disease status. All 60 cases were confirmed positive with neutralization assay (VITROS HBsAg Confirmatory Kit) while no target was detected on viral load assessment with RT-PCR. Sixteen donors were HBeAg positive (4 IgM anti-HBc positive and 12 IgM anti-HBc negative) and 44 were IgM anti-HBc negative, anti-HBc total positive, and anti-HBe positive., Conclusion: About 7.7% of HBsAg positive and NAT nonreactive donors (nondetectable HBV DNA) could be potentially infectious (HBeAg positive), whereas rest of the donors were consistent with chronic HBV infection.
- Published
- 2015
- Full Text
- View/download PDF
25. Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
- Author
-
Tiwari AK, Pandey PK, Negi A, Bagga R, Shanker A, Baveja U, Vimarsh R, Bhargava R, Dara RC, and Rawat G
- Abstract
Introduction: Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value., Materials and Methods: The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%., Results: An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested., Conclusion: The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
- Published
- 2015
- Full Text
- View/download PDF
26. CAPA analysis of clotted red cell unit detected during leukodepletion process: Importance of quality check on blood collection monitors.
- Author
-
Dara RC, Tiwari AK, Arora D, Rawat G, and Raina V
- Published
- 2015
- Full Text
- View/download PDF
27. Approach to a case of multiple irregular red cell antibodies in a liver transplant recipient: Need for developing competence.
- Author
-
Dara RC, Tiwari AK, Pandey P, and Arora D
- Abstract
Liver transplant procedure acts as a challenge for transfusion services in terms of specialized blood components, serologic problems, and immunologic effects of transfusion. Red cell alloimmunization in patients awaiting a liver transplant complicate the process by undue delay or unavailability of compatible red blood cell units. Compatible blood units can be provided by well-equipped immunohematology laboratory, which has expertise in resolving these serological problems. This report illustrates resolution of a case with multiple alloantibodies using standard techniques, particularly rare antisera. Our case re-emphasizes the need for universal antibody screening in all patients as part of pretransfusion testing, which helps to identify atypical antibodies and plan for appropriate transfusion support well in time. We recommend that the centers, especially the ones that perform complex procedures like solid organ transplants and hematological transplants should have the necessary immunohematological reagents including rare antisera to resolve complex cases of multiple antibodies as illustrated in this case.
- Published
- 2015
- Full Text
- View/download PDF
28. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.
- Author
-
Tiwari AK, Pandey PK, Dara RC, Rawat GS, Raina V, and Bhargava R
- Abstract
Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency., Aims: This study was designed to evaluate the performance of newly introduced VITROS(®) syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India., Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at -20°C, were used to evaluate the performance of VITROS(®) syphilis TPA assay based on enhanced chemiluminescence assay on VITROS(®) ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies., Results: VITROS(®) syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of <10% co-efficient of variation. There was no cross-reactivity with other viral and auto-immune antibodies. No interference was observed from endogenous interfering substances like free hemoglobin or fats., Conclusions: Performance of the VITROS(®) syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.
- Published
- 2015
- Full Text
- View/download PDF
29. Allo-antibody identification: a software approach!
- Author
-
Tiwari AK, Dara RC, Arora D, Aggarwal G, Rawat G, Mitra S, Prashant PK, and Raina V
- Subjects
- Female, Humans, Male, Retrospective Studies, Algorithms, Isoantibodies blood, Software
- Abstract
Background: Unexpected allo-antibody identification is difficult serological test requiring in-depth knowledge of antibody behavior, identification rules, knowledge of zygosity of antigens and dosage phenomenon. Software which uses an algorithm based on characteristics of antibodies is now available to interpret specificity of allo-antibody. A study was undertaken to evaluate the effectiveness of one such software (Resolvigen) for antibody identification compared with manual antibody identification method., Materials and Methods: The study was a retrospective observational study where 238 allo-antibody results were re-evaluated using Resolvigen software (Ortho Clinical Diagnostics, Johnson and Johnson, Raritan, NJ, USA) and agreement between manual and software approaches was studied. Resolvigen software was also evaluated for usefulness, ease of use and predicted future usage by administering investigators a questionnaire with Likert scale., Results: Agreement between the results of manual and automated methods ranged from 98.6% for single antibody to 65% for two antibodies (p = 0.000). Resolvigen software came out as very useful, easy to use, and with high predicted future usage., Conclusion: This study concludes that Resolvigen can either replace manual method or be used as adjuvant to routine manual method., (Copyright © 2014 Elsevier Ltd. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
30. Cascade plasmapheresis (CP) as a preconditioning regime in ABO-incompatible live related donor liver transplants (ABOi-LDLT).
- Author
-
Tiwari AK, Pandey P, Aggarwal G, Dara RC, Rawat G, Raina V, and Soin AS
- Abstract
Background: ABO-incompatible live donor liver transplant (ABOi-LDLT) is being widely done to bridge the gap of demand and supply of organs. Different desensitization regimes are being used to reduce titer of blood group antibodies for successful transplant and accommodation of graft. The authors used cascade plasmapheresis (CP) to bring down titer of naturally occurring blood group antibody to 16 or lower., Material and Methods: Four recipients of ABOi-LDLT were of blood groups O, O, B, and B while donors were of blood groups B, A, AB, and AB, respectively. Desensitization protocol included immunosuppressive drugs and plasmapheresis. CP consisted of separating patient's plasma as the first step and passing it through pore size based filter column as the second step. The first step was performed using disposable kit (PL1, Fresenius Kabi, Germany) with minor modification on apheresis equipment COM.TEC (Fresenius Kabi, Germany). Pore size based filter column used was 2A column (Evaflux, Kawasumi Laboratories, Japan). Blood group antibody titer (immunoglobulin G (IgG)) was done by column agglutination technology (Ortho-Clinical Diagnostics)., Results: Cases 1, 2, 3, and 4 with pre-CP titer of 1,024, 512, 32, and 64 required four, three, one, and one CP procedures, respectively. No signs of antibody-mediated rejection were exhibited on histopathological evaluation by any of the patients. Successful organ engraftment occurred as documented by post-operative liver function tests and liver biopsy., Conclusion: Cascade plasmapheresis offers a cost-effective and efficient way to decrease blood group antibody titer and helps in successful transplant.
- Published
- 2014
- Full Text
- View/download PDF
Catalog