6 results on '"Daniele Guerrieri"'
Search Results
2. Effects of contrast-enhancement on diffusion weighted imaging and apparent diffusion coefficient measurements in 3-T magnetic resonance imaging of breast lesions
- Author
-
Daniele Guerrieri, Simone Celsa, Carlo de Felice, Giacomo Bonito, and V Cipolla
- Subjects
Adult ,Contrast enhancement ,Gadolinium ,media_common.quotation_subject ,Contrast Media ,chemistry.chemical_element ,Breast Neoplasms ,Sensitivity and Specificity ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Parenchyma ,medicine ,Humans ,Effective diffusion coefficient ,Contrast (vision) ,Radiology, Nuclear Medicine and imaging ,Aged ,media_common ,Radiological and Ultrasound Technology ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,Magnetic resonance imaging ,General Medicine ,Middle Aged ,Image Enhancement ,Magnetic Resonance Imaging ,Diffusion Magnetic Resonance Imaging ,chemistry ,030220 oncology & carcinogenesis ,Female ,Signal intensity ,Nuclear medicine ,business ,Diffusion MRI - Abstract
Background The effect of gadolinium-based contrast agents on diffusion-weighted imaging (DWI) measurements of breast lesions is still not clear. Purpose To investigate gadolinium effects on DWI and apparent diffusion coefficient (ADC) in breast lesions and normal parenchyma with 3 Tesla contrast-enhanced MRI. Material and Methods Pre- and post-contrast DWI (b = 0 and b = 1000 s/mm2) were acquired in 47 patients. Measured ADC values, pre- and post-contrast T2 signal intensity (T2 SI) and contrast-to-noise ratio (CNR) were compared with Wilcoxon signed-rank and rank-sum test ( P Results Post-contrast ADC was reduced only in malignant lesions (−34%), T2 SI was reduced both in malignant (−50%) and benign (−36%) lesions. Post-contrast CNR was reduced in all groups except for benign lesions. Conclusion Gadolinium-based contrast agent causes a significant reduction in ADC values of malignant breast lesions.
- Published
- 2017
- Full Text
- View/download PDF
3. Extraocular muscle sampled volume in Graves' orbitopathy using 3-T fast spin-echo MRI with iterative decomposition of water and fat sequences
- Author
-
Daniele Guerrieri, Ludovico Maria Garau, Alice Bruscolini, G. Panzironi, and Flaminia De Cristofaro
- Subjects
Contrast enhancement ,genetic structures ,030209 endocrinology & metabolism ,Extraocular muscles ,030218 nuclear medicine & medical imaging ,Graves' ophthalmopathy ,03 medical and health sciences ,0302 clinical medicine ,Nuclear magnetic resonance ,medicine ,orbit ,medicine.diagnostic_test ,business.industry ,Research ,segmentation ,Magnetic resonance imaging ,extraocular muscle volume ,General Medicine ,Fast spin echo ,Graves ophthalmopathy ,medicine.disease ,eye diseases ,graves ophthalmopathy ,contrast enhancement ,magnetic resonance (mr) ,medicine.anatomical_structure ,sense organs ,business ,magnetic resonance (MR) ,Orbit (anatomy) ,Volume (compression) - Abstract
Background Current magnetic resonance imaging (MRI) techniques for measuring extraocular muscle (EOM) volume enlargement are not ideally suited for routine follow-up of Graves’ ophthalmopathy (GO) because the difficulty of segmenting the muscles at the tendon insertion complicates and lengthens the study protocol. Purpose To measure the EOM sampled volume (SV) and assess its correlation with proptosis. Material and Methods A total of 37 patients with newly diagnosed GO underwent 3-T MRI scanning with iterative decomposition of water and fat (IDEAL) sequences with and without contrast enhancement. In each patient, the three largest contiguous coronal cross-sectional areas (CSA) on the EOM slices were segmented using a polygon selection tool and then summed to compute the EOM-SV. Proptosis was evaluated with the Hertel index (HI). The relationships between the HI value and EOM-SV and between HI and EOM-CSA were compared and assessed with Pearson’s correlation coefficient and the univariate regression coefficient. Inter-observer and intra-observer variability were calculated. Results HI showed a stronger correlation with EOM-SV ( P 2 = 0.507) than with EOM-CSA ( P 2 = 0.329). The intraclass correlation coefficient indicated that the inter-observer agreement was high (0.998). The standard deviation between repeated measurements was 1.9–5.3%. Conclusion IDEAL sequences allow for the measurement EOM-SV both on non-contrast and contrast-enhanced scans. EOM-SV predicts proptosis more accurately than does EOM-CSA. The measurement of EOM-SV is practical and reproducible. EOM-SV changes of 3.5–8.3% can be assumed to reflect true volume changes.
- Published
- 2017
4. Magnetic Resonance Imaging
- Author
-
Michele Anzidei, Fabrizio Boni, Vincenzo Noce, Daniele Guerrieri, Beatrice Sacconi, and Carlo Catalano
- Published
- 2017
- Full Text
- View/download PDF
5. Role of 3.0 Tesla magnetic resonance hysterosalpingography in the diagnostic work-up of female infertility
- Author
-
Carlo de Felice, V Cipolla, Daniela Pietrangeli, Daniele Guerrieri, Renato Argirò, and Domiziana Santucci
- Subjects
Adult ,Gadolinium DTPA ,medicine.medical_specialty ,3 Tesla magnetic resonance imaging (MRI) ,3.0T MR hysterosalpingography ,Female infertility ,tubal patency ,Contrast Media ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Hysterosalpingography ,Prospective Studies ,Prospective cohort study ,Pelvis ,030219 obstetrics & reproductive medicine ,Radiological and Ultrasound Technology ,medicine.diagnostic_test ,business.industry ,Magnetic resonance imaging ,General Medicine ,medicine.disease ,Mr imaging ,Magnetic Resonance Imaging ,Work-up ,medicine.anatomical_structure ,Feasibility Studies ,Female ,Radiology ,business ,Infertility, Female - Abstract
Background Imaging evaluation plays a crucial role in the diagnostic work-up of female infertility. In recent years, the possibility to evaluate tubal patency using 1.5 Tesla magnetic resonance (1.5T MR) has been studied. Purpose To assess the feasibility of 3.0 Tesla magnetic resonance (3.0T MR) hysterosalpingography and its role in the diagnostic work-up of female infertility and to evaluate if this fast “one-stop-shop” imaging approach should be proposed as a first-line examination. Material and Methods A total of 116 infertile women were enrolled in this prospective study; all underwent 3.0T MR hysterosalpingography. After standard imaging of the pelvis, tubal patency was assessed by acquiring 3D dynamic time-resolved T1-weighted (T1W) sequences during manual injection of 4–5 mL of contrast solution consisting of gadolinium and normal sterile saline. Images were evaluated by two radiologists with different experience in MR imaging (MRI). Results The examination was successfully completed in 96.5% of cases, failure rate was 3.5%. Dynamic sequences showed bilateral tubal patency in 64.3%, unilateral tubal patency in 25.9%, and bilateral tubal occlusion in 9.8%. Extratubal abnormalities were found in 69.9% of patients. Comprehensive analysis of morphological and dynamic sequences showed extratubal abnormalities in 43.1% of patients with bilateral tubal patency. Conclusion 3.0T MR hysterosalpingography is a feasible, simple, fast, safe, and well-tolerated examination, which allows evaluation of tubal patency and other pelvic causes of female infertility in a single session, and it may thus represent a “one-stop-shop” solution in female infertility diagnostic work-up.
- Published
- 2015
6. *Correlation between 3T apparent diffusion coefficient values and grading of invasive breast carcinoma*
- Author
-
Francesco Maria Drudi, Meggiorini Ml, Domiziana Santucci, Carlo de Felice, Daniele Guerrieri, and V Cipolla
- Subjects
Adult ,medicine.medical_specialty ,Breast Neoplasms ,Lesion ,Correlation ,Breast cancer ,medicine ,Chi-square test ,Effective diffusion coefficient ,Humans ,Radiology, Nuclear Medicine and imaging ,Grading (education) ,Aged ,Retrospective Studies ,Aged, 80 and over ,Apparent diffusion coefficient, Breast magnetic resonance, Diffusion-weighted imaging, Grading, Invasive breast carcinoma ,medicine.diagnostic_test ,business.industry ,Carcinoma, Ductal, Breast ,Magnetic resonance imaging ,General Medicine ,Middle Aged ,medicine.disease ,Breast magnetic resonance ,Carcinoma, Lobular ,Grading ,Invasive breast carcinoma ,Diffusion Magnetic Resonance Imaging ,Apparent diffusion coefficient ,Female ,Radiology ,Diffusion-weighted imaging ,medicine.symptom ,business ,Diffusion MRI - Abstract
Purpose The aim of this study was to evaluate whether the apparent diffusion coefficient (ADC) provided by 3.0T (3T) magnetic resonance diffusion-weighted imaging (DWI) varied according to the grading of invasive breast carcinoma. Materials and methods A total of 92 patients with 96 invasive breast cancer lesions were enrolled; all had undergone 3T magnetic resonance imaging (MRI) for local staging. All lesions were confirmed by histological analysis, and tumor grade was established according to the Nottingham Grading System (NGS). MRI included both dynamic contrast-enhanced and DWI sequences, and ADC value was calculated for each lesion. ADC values were compared with NGS classification using the Mann–Whitney U and the Kruskal–Wallis H tests. Grading was considered as a comprehensive prognostic factor, and Rho Spearman test was performed to determine correlation between grading and tumor size, hormonal receptor status, HER2 expression and Ki67 index. Pearson's Chi square test was carried out to compare grading with the other prognostic factors. Results ADC values were significantly higher in G1 than in G3 tumors. No significant difference was observed when G1 and G3 were compared with G2. Tumor size, hormonal receptor status, HER2 expression and Ki67 index correlated significantly with grading but there was a significant difference only between G1 and G3 related to the ER and PR status, HER2 expression and Ki67 index. There was no statistically significant difference in lesion size between the two groups. Conclusion ADC values obtained on 3T DWI correlated with low-grade (G1) and high-grade (G3) invasive breast carcinoma. 3T ADC may be a helpful tool for identifying high-grade invasive breast carcinoma.
- Published
- 2014
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.