303 results on '"DQO"'
Search Results
2. Análisis comparativo de filtros artesanales para tratamiento de aguas grises en áreas rurales
- Author
-
Jeanny Elizabeth de Leon Rios
- Subjects
viruta verde de pino ,estopa de coco ,lecho filtrante ,DBO ,DQO ,nitratos ,Technology ,Technical hydraulics ,TC160-181 ,Environmental sciences ,GE1-350 - Abstract
Este estudio compara la eficiencia de dos filtros artesanales, usando materiales disponibles en áreas rurales con ausencia de sistema de drenaje, lo que obliga tratar las aguas grises para evitar contaminación. Entonces, el objetivo fue determinar la eficiencia de los filtros en función al tipo de material filtrante, siendo estos: 1) arena, grava, carbón activado, viruta de pino verde; y 2) estopa de coco. La eficiencia de estos se determinó a partir de la medición de la demanda química de oxígeno (DQO), demanda bioquímica de oxígeno (DBO), nitritos, nitratos, fosfatos, color aparente, color real, sólido suspendido, y turbidez en afluente y efluente del filtro. Para este estudio, los filtros se construyeron en una comunidad ubicada en El Paraje de Choquixcabel del municipio de Santa Lucía Utatlán departamento de Sololá, Guatemala. Durante la evaluación se utilizó aguas grises generadas por el lavado de ropa y el agua de la ducha. Durante el estudio se recogieron un total de 12 muestras de afluentes y efluentes. El filtro que presentó mayor eficiencia al 75% en la remoción de parámetros físicos, inorgánicos no metales y orgánicos agregados, fue el de lecho filtrante de viruta de pino verde, aunque su comportamiento no fue constante. Estos filtros presentaron mucha variación con respecto a los resultados, debido al tiempo de almacenamiento del agua en el recipiente del filtro debido al tiempo necesario para la recolección del agua en el hogar.
- Published
- 2023
- Full Text
- View/download PDF
3. HUMEDALES CONSTRUIDOS BIOACTIVADOS CON MICROORGANISMOS EFICIENTES: UNA VÍA PARA LA GESTIÓN DE RESIDUALES EN EL MATADERO CHICHÍ PADRÓN
- Author
-
Guillermo Esperanza Pérez, Yamell Jiménez Prieto, and María del C. Manrique Rasúa
- Subjects
aguas residuales ,dbo5 ,dqo ,humedales ,mataderos ,microorganismos eficientes ,Special industries and trades ,HD9000-9999 - Abstract
Introducción: Los humedales construidos son tecnologías “verdes”, sencillas, asequibles, y eficientes para el tratamiento de varios tipos de aguas residuales que, comparadas con los sistemas convencionales, ofrecen un enfoque respetuoso con el medio ambiente, tienen bajos costos, y un elevado potencial para ser aplicadas preferentemente en países en vías de desarrollo. Objetivo: Evaluar la eficiencia de humedales de flujo subsuperficial horizontal bioactivados con microorganismos eficientes, en la remoción de materia orgánica y otros contaminantes presentes en aguas residuales del matadero Chichí Padrón. Materiales y Métodos: Fueron construidos cuatro sistemas de humedales, sembrados con Cyperus Alternifolius, utilizando como sustratos combinaciones de suelo pardo, grava de caliza, zeolita, y arena de rio. Se empleó un diseño factorial 23 para evaluar la influencia del tiempo de retención hidráulico, la activación con microorganismos, y el tipo de sustrato sobre la eficiencia en la eliminación de los contaminantes. Resultados y Discusión: Se caracterizaron los residuales del proceso productivo, estudiándose los valores históricos del último decenio. La eficiencia máxima de remoción se logró en los sistemas S2 bioactivados, para 96 horas, i.e. 96 % para la DQO, 96,4 % para la DBO5, y 94 % para grasas y aceites. Se obtuvieron además los modelos matemáticos que describen la relación variable entrada-respuesta, con elevados coeficientes de correlación (0,95-0,99). Conclusiones: El empleo de humedales de flujo subsuperficial puede considerarse un método eficiente para el tratamiento de aguas residuales generadas en mataderos, lográndose elevados niveles de remoción de sus contaminantes, y efluentes compatibles con las regulaciones ambientales cubanas.
- Published
- 2022
4. Caracterización en tiempo real de la carga contaminante en aguas residuales tratada mediante espectrofotometría LED
- Author
-
Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fundación Séneca, Carreres-Prieto, Daniel, Rancaño Pérez, Amador, García Bermejo, Juan Tomás, Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Fundación Séneca, Carreres-Prieto, Daniel, Rancaño Pérez, Amador, and García Bermejo, Juan Tomás
- Abstract
En este trabajo de investigación se presenta un sistema de análisis indirecto y en tiempo real de la carga contaminante de las aguas residuales, mediante el uso de espectrofotometría LED en rango visible, que en combinación con 10 modelos basados en algoritmos genéticos, es capaz de caracterizar los siguientes contaminantes con alta precisión: DQO, SST, NT, NTK y N-NO3-, tanto en muestras de agua residual bruta como tratada, los cuales han sido calculados a parir de unas 430 muestras procedentes de 14 EDARs de la Región de Murcia gestionadas por la empresa ACCIONA. El equipo empleado forma parte de un sistema de alerta temprana, el cual ha sido probado en condicione reales de operación en la EDAR de Bullas, que operando de forma autónoma, permite conocer cómo varia la concentración de contaminantes en las distintas etapas de un EDAR, con el fin de poder llevar a cabo una gestión más eficiente de los proceso de depuración y contribuir a alcanzar una adecuada calidad de salida de las aguas regeneradas. La precisión de los modelos queda en evidencia con los bajos valores de RMSE, especialmente en el caso del agua tratada, destacando el RMSE de 2.43 mg/L de SST, 0.81 mg/L del NT, 0.86 mg/L de NTK y el 0.4 de N-NO3-.
- Published
- 2024
5. Efficiency in the reduction of oil organic matter combining solar advanced oxidation processes and the biological reactor of a WWTP
- Author
-
Guillermo Centeno-Bordones, Henry Labrador, Guillermo Lara, and Ygmar Jiménez
- Subjects
ptar ,dqo ,dbo ,oxidación fotoquímica ,oxidación biológica ,Ocean engineering ,TC1501-1800 ,Hydraulic engineering ,TC1-978 - Abstract
A review of historical data of the effluent of PDVSA’s WWTP was carried out in its research and development subsidiary in the City of Los Teques, Miranda State, during the period 2003-2014. It was sampled for six weeks to calculate the efficiency in the removal of COD, BOD5 and SST. The efficiency for COD was 86.51% and 72.94% in BOD5. The proportion of biological sludge and sour water treated with advanced oxidation processes (POA), necessary for the reduction of COD and BOD5, was determined. The best result obtained in it was 222 mg /L of COD and BOD5 32.15 mg /L, satisfying the national standard for discharge into natural bodies of water.
- Published
- 2021
- Full Text
- View/download PDF
6. Tratamientos de Aguas Residuales en el Corredor Parrilla II en Centro, Tabasco.
- Author
-
Aguilar Pérez, Gisell, Pampillón González, Liliana, and López Ocaña, Gaspar
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
7. Aplicación del Proceso Fenton para Sistemas Acuosos con Fenol Utilizando Magnetita Nanoestructurada.
- Author
-
Armas Manríquez, Daniel, Josefina Rodríguez Rosales, María Dolores, Escobedo Bretado, Miguel Ángel, Rojas Montes, Jaime Cristóbal, and Lucho Chigo, Rafael
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
8. HUMEDALES CONSTRUIDOS BIOACTIVADOS CON MICROORGANISMOS EFICIENTES: UNA VÍA PARA LA GESTIÓN DE RESIDUALES EN EL MATADERO CHICHÍ PADRÓN.
- Author
-
Esperanza Pérez, Guillermo, Jiménez Prieto, Yamell, and Manrique Rasúa, María del C.
- Subjects
- *
ORGANIC compounds removal (Sewage purification) , *SLAUGHTERING , *CONSTRUCTED wetlands , *WETLANDS , *WASTE management , *WASTEWATER treatment , *ADVECTION , *MICROORGANISMS , *FACTORIAL experiment designs , *INDUSTRIAL wastes , *OIL spill cleanup , *POLLUTION , *SHALE oils , *FATS & oils - Abstract
Introduction: Constructed wetlands are simple, affordable, and efficient “green” technologies for the treatment of various types of wastewater that, compared to conventional systems, offer an environmentally friendly approach, have low costs, and high potential for application preferably in developing countries. Objective: To evaluate the efficiency of horizontal subsurface flow wetlands bioactivated with efficient microorganisms in the removal of organic matter and other contaminants present in wastewater from the Chichí Padrón slaughterhouse. Materials and Methods: Four wetland systems were constructed, planted with Cyperus Alternifolius, using combinations of brown soil, limestone gravel, zeolite, and river sand as substrates. A 23 factorial design was used to evaluate the influence of hydraulic retention time, activation with microorganisms, and the type on pollutant removal efficiency. Results and Discussion: The waste from the production process were characterized, and the historical values of the last decade were studied. The maximum removal efficiency was achieved in the bioactivated S2 systems, for 96 hours, i.e. 96% for COD, 96.4% for BOD5, and 94% for fats and oils. Mathematical models describing the variable input-response variable relationship were also obtained, with high correlation coefficients (0.95-0.99). Conclusions: The use of subsurface flow wetland systems can be considered an efficient method for the treatment of wastewater generated in slaughterhouses, achieving high levels of pollutant removal and effluents compatible with the Cuban environmental regulations. [ABSTRACT FROM AUTHOR]
- Published
- 2022
9. Reducción de la concentración de DQO y COT en aguas residuales de la industria farmacéutica empleando ozono catalizado por Fe2+. Estudio de caso a escala real
- Author
-
Camila Pedreros Calvo, Kelly Viviana Valderrama Lopez, Rafael Nikolay Agudelo Valencia, Karina Pérez Cortés, and Carlos Enrique Campo
- Subjects
ozono ,ozone ,procesos de oxidación avanzada ,advanced oxidation processes ,catalizador ,catalyst ,dqo ,cod ,cot ,toc ,agua residual farmacéutica ,pharmaceutical wastewater ,Science ,Science (General) ,Q1-390 ,Social sciences (General) ,H1-99 - Abstract
El presente trabajo fue realizado con el fin de mejorar el desempeño de un sistema de ozonización utilizado para el tratamiento de aguas residuales en una industria farmacéutica. Con el objeto de mejorar la mineralización de la materia orgánica, se aplicó como catalizador sulfato ferroso al sistema de reacción. Seguido de esto, se ajustó el pH del agua entre 8,5 y 10 para que el proceso se lleve a cabo en condiciones alcalinas. Finalmente, se inyectó O3 a través de un tubo Venturi con el fin de mejorar el intercambio de masa entre el gas y el agua. Los datos preliminares de operación del sistema de tratamiento señalan que este alcanza remociones de demanda química de oxígeno (DQO) menores a 10 %. Los ensayos fueron realizados a escala real y las variables de calidad del agua fueron analizadas a diferentes tiempos de reacción. Se determinó que para una dosis de ozono igual a 10 g/h y 10 mg/L de Fe2+ y un pH inicial del agua igual a 9 se requieren de 4,5 horas a fin de lograr una reducción de 30,73 % de DQO y 36,85 % de carbón orgánico total (COT). Los resultados realizados con un pH inicial superior a 9,5 señalan que la efectividad del proceso se reduce, hecho que puede ser ocasionado por la rápida formación de Fe(OH)3 insoluble, con lo cual disminuye la disponibilidad del catalizador para la formación de radicales OH* en el agua.
- Published
- 2021
- Full Text
- View/download PDF
10. La demanda química de oxígeno con el procedimiento APHA/AWWA/WEF 5220 D para rango alto adaptado a microescala
- Author
-
Julio César Morales-Mejía, María Gabriela Vargas-Martínez, and Javier Medina Camps
- Subjects
dqo ,microescala ,linealidad ,precisión ,agua ,métodos estandarizados ,Hydraulic engineering ,TC1-978 ,Water supply for domestic and industrial purposes ,TD201-500 - Abstract
En este estudio se realizaron pruebas de linealidad y de precisión, a fin de determinar la demanda química de oxígeno (DQO) en agua para una adaptación a microescala del método de reflujo cerrado a volumen pequeño para rango alto de APHA/AWWA/WEF. El trabajo tuvo como objetivo principal demostrar que es posible obtener mediciones adecuadas al adaptar a microescala el método 5220 D de APHA/AWWA/WEF, referencia de amplio uso internacional para determinar la DQO en agua. El método adaptado a microescala requirió solamente de cambios en la concentración de cada sustancia en la solución de digestión, pero no así en la solución catalizadora de sulfato de plata, de manera tal que la concentración de cada una de estas sustancias en los tubos de digestión fuera casi igual a aquella correspondiente al método original (exceptuando la del sulfato de mercurio, que fue reducida de forma deliberada). En la adaptación a microescala que aquí se presenta, los volúmenes dosificados de todos los reactivos líquidos se midieron con pipetas volumétricas clase A, mejorando la precisión en las mediciones con respecto al uso tanto de pipetas graduadas como de émbolo (necesarias para efectuar el método original). Los resultados obtenidos para la adaptación a microescala demostraron excelente ajuste lineal y precisión del sistema.
- Published
- 2021
- Full Text
- View/download PDF
11. Electrocoagulación con electrodos de aluminio para tratamiento de aguas residuales de curtiembres en Villapinzón, Cundinamarca, Colombia.
- Author
-
Muñoz Espitia, Miguel Ángel, Cortés Bermúdez, Jairo David, and Agudelo Valencia, Rafael Nikolay
- Subjects
- *
ALUMINUM electrodes , *CHEMICAL oxygen demand , *CHEMICAL reduction , *TURBIDITY , *ELECTRODES - Abstract
This article derives from the research project “Analysis of the efficiency of electrocoagulation with aluminum electrodes for the reduction of turbidity and chemical oxygen demand (COD) in wastewater from fur cleaning process in the municipality of Villapinzón,” developed at Universidad Libre, Bogotá, in 2019. These wastewaters have high concentrations of polluting substances that are discharged and affect effluents. Therefore, this study seeks to evaluate a laboratory-scale electrocoagulation system in order to remove turbidity and COD by means of tests carried out in discontinuous mode for periods of 45 minutes. With variations in the number of electrodes (2, 4 and 6; flat and perforated), and an applied current of 12 A and 10 V, the maximum removal of turbidity, sulfides and COD reached values of 99.77 and 74.1% respectively, when 4 flat electrodes were used. For turbidity, the use of perforated electrodes allowed obtaining removal values of 98% (with 2 electrodes). This technique also allows to eliminate sulfides, using 4 and 6 electrodes, thus achieving removal figures of 45.86 and 48.21%, respectively. Findings of this study conclude that the adequate number of electrodes for the process is 4, and that increasing the number of electrodes reduces the current density, increases the contact area, and favors the dissolution of aluminum excess. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
12. Evaluación de la Moringa oleifera en el tratamiento de aguas con alta turbidez y carga orgánica
- Author
-
P. W. Mejía Carrillo, K. Urquia Collantes, R. J. Cabello Torres, and L. G. Valdiviezo Gonzales
- Subjects
coagulante natural ,moringa oleífera ,eficiencia de remoción ,dbo5 ,dqo ,turbidez ,ph ,Ocean engineering ,TC1501-1800 ,Hydraulic engineering ,TC1-978 - Abstract
El presente trabajo evalúa la eficiencia del uso de la Moringa oleífera (M.O) como coagulante en el tratamiento de aguas de alta turbidez y carga orgánica. Inicialmente los resultados demostraron que el coagulante a base de las semillas de M.O pre-tratada con cloruro de sodio (NaCl 1.0 N) y usando una dosis de 0.74 g/L, alcanza remociones de 87.3% y 88.8% para turbidez y sólidos suspendidos totales (SST), asimismo valores de 25.9% y 26.3% para DBO5 y DQO respectivamente. En una segunda etapa, el coagulante, sometido a extracción Soxhlet y dosis de 0.5 g/L, muestran máximas eficiencia de 97.8%, 89.99%, 51.4% y 35.3% en la remoción de turbidez, SST, DQO y DBO5. Las más altas eficiencias obtenidas fueron alcanzadas mediante la previa extracción de aceites, grasas y otros componentes de la semilla de M.O. Estudios relacionados al reaprovechamiento de sub-productos de la extracción deben ser realizados.
- Published
- 2020
- Full Text
- View/download PDF
13. Uso de la filtración en bloques de suelo como tratamiento secundario de aguas residuales ordinarias.
- Author
-
Alejandro Quirós Ivankovich
- Subjects
Plantas de tratamiento ,DBO ,DQO ,SST ,sostenibilidad ,filtros percoladores ,Technology ,Technical hydraulics ,TC160-181 ,Environmental sciences ,GE1-350 - Abstract
Este artículo se basa en experimentación realizada con el sistema de Filtración en Bloques de Suelo o Multi Soil Layering System (MSL) que constituye una tecnología de depuración de aguas residuales novedosa, cuyas características la hacen ideal para ser aplicada en zonas rurales y de manera colectiva. Las investigaciones previas han mostrado resultados prometedores al tratar aguas residuales domésticas, eliminando gran cantidad de materia orgánica, sólidos suspendidos, nutrientes, entre otros contaminantes. El sistema MSL se puede construir a bajo costo, con materiales locales, ofreciendo un buen desempeño y una operación y mantenimiento sencillos y baratas. Se utiliza como tratamiento secundario, requiriendo un área varias veces menor que otras tecnologías típicamente recomendadas para poblaciones rurales. Para la realización del estudio se construyeron cuatro pilotos MSL, los cuales reciben el efluente de un Reactor Anaerobio de Flujo Ascendente (RAFA) que cuenta con un pretratamiento previo. Se miden parámetros de calidad a la entrada y salida de los sistemas, tales como DBO, DQO, SST, entre otros. Todos los pilotos lograron cumplir con los límites establecidos en la legislación costarricense, y se lograron porcentajes de remoción de al menos 75% para DBO, DQO y SST. Sin embargo, estos parámetros son considerablemente mejores en algunos de los cuatro pilotos probados en el estudio.
- Published
- 2022
14. Electrocoagulación con electrodos de aluminio para tratamiento de aguas residuales de curtiembres en Villapinzón, Cundinamarca, Colombia
- Author
-
Miguel Ángel Muñoz Espitia, Jairo David Cortés Bermúdez, and Rafael Nikolay Agudelo Valencia
- Subjects
electrodos planos ,electrodos perforados ,turbiedad ,DQO ,sulfuros ,Science ,Science (General) ,Q1-390 ,Social sciences (General) ,H1-99 - Abstract
Este articulo proviene de la investigación “Análisis de la eficiencia de la electrocoagulación con electrodos de aluminio para la reducción de turbidez y demanda química de oxígeno (DQO) en las aguas residuales de pelambre en el municipio de Villapinzón, Cundinamarca”, la cual se desarrolló en la Universidad Libre, seccional Bogotá, en 2019. Los residuos líquidos provenientes de las curtiembres tienen como problemática común las aguas obtenidas del proceso de pelambre, ya que poseen altas concentraciones de sustancias contaminantes que son vertidas y afectan a cuerpos de agua. Por ello, este estudio tiene como objetivo evaluar un sistema de electrocoagulación a escala de laboratorio para remover turbiedad y DQO, por medio de ensayos realizados en modo discontinuo por períodos de 45 minutos. Con variaciones en la cantidad de electrodos (2, 4 y 6; planos y perforados) y con una intensidad de corriente aplicada de 12 A y 10 V, la máxima remoción de turbiedad y DQO alcanzó valores de 99,77 y 74,18 %, respectivamente, cuando se usaron 4 electrodos planos. Para turbiedad, el uso de electrodos perforados permitió alcanzar valores de remoción del 98 % (con 2 electrodos). Esta técnica también permite eliminar sulfuros, empleando 4 y 6 electrodos, alcanzando una remoción de 45,86 y 48,21 %, respectivamente. En el estudio se pudo determinar que la cantidad adecuada de electrodos para el proceso es 4. El aumento del número de electrodos reduce la densidad de corriente, aumenta el área de contacto y favorece la disolución de aluminio en exceso.
- Published
- 2022
- Full Text
- View/download PDF
15. Eficiencia en la reducción de materia orgánica petrolera combinando procesos de oxidación avanzada solar y el reactor biológico de una PTAR.
- Author
-
Centeno-Bordones, Guillermo, Labrador, Henry, Lara, Guillermo, and Jiméneza, Ygmar
- Abstract
Copyright of Ingeniería del Agua is the property of Universidad Politecnica de Valencia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
16. Tratamiento de Agua Residual Doméstica en una Institución Educativa vía Humedales Artificiales.
- Author
-
Hernández Almeida, María Fernanda, Estrada Pérez, Nancy, and López Ocaña, Gaspar
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
17. Evaluación de un Sistema de Tratamiento de Agua Residual Industrial que fue Optimizado Vía Humedales Artificiales.
- Author
-
Estrada Pérez, Nancy, Gerónimo López, Manuel Antonio, Pampillón Gonzáles, Liliana, Ortíz Alcocer, Víctor, and López Ocaña, Gaspar
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
18. PROJETO DE REATOR ANAERÓBIO DE FLUXO ASCENDENTE (RAFA) PARA TRATAMENTO DE VINHAÇA
- Author
-
Bruce Wellington Amorin da Silva, Márcio Roberto Duran Filho, Luana Inada Souza Santos, Beatriz Leite, and Douglas Liberace de Matos
- Subjects
RAFA ,biogás ,vinhaça ,DBO ,DQO ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Science (General) ,Q1-390 - Abstract
O Brasil é o maior produtor de açúcar e álcool do mundo, consequentemente, é também um grande produtor de vinhaça, o que é um problema, já que possui elevado potencial de poluição, impactando gravemente o solo e a água, apesar de ser usada na fertirrigação do canavial. Ao ser tratada em anaerobiose, contudo, pode produzir energia e ser usada como biofertilizante para o solo. Esse tratamento pode ser executado por um Reator Anaeróbio de Fluxo Ascendente (RAFA), considerado eficiente pela literatura. A partir disso, esse artigo tenta reunir equações e coletar dados, revisando a literatura científica com o objetivo de projetar um RAFA para tratamento de vinhaça, expondo uma alternativa de disposição final adequada a esse subproduto. Os resultados mostram boas oportunidades, com um grande potencial de redução de DBO e DQO e produção de biogás, eletricidade e biofertilizante, além de fornecer um compilado de equações e dados importantes para futuros cálculos.
- Published
- 2021
19. Evaluation of electrocoagulation in the post-treatment of anaerobic wastewater of slaughterhouse and packing plant.
- Author
-
Manente da Silva, Flavia, Orssatto, Fábio, Eyng, Eduardo, Mantovani Frare, Laercio, José Baraldi, Ilton, and Fleck, Leandro
- Subjects
COLOR removal (Sewage purification) ,CURRENT density (Electromagnetism) ,PROBLEM solving ,SLAUGHTERING ,OPERATING costs ,SEWAGE - Abstract
Copyright of Revista Ambiente e Água is the property of Revista Ambiente e Agua and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
20. Reducción de la concentración de DQO y COT en aguas residuales de la industria farmacéutica empleando ozono catalizado por Fe2+. Estudio de caso a escala real.
- Author
-
Pedreros Calvo, Camila, Valderrama López, Kelly Viviana, Agudelo Valencia, Rafael Nikolay, Pérez Cortés, Karina, and Enrique Campo, Carlos
- Subjects
- *
FERROUS sulfate , *WASTEWATER treatment , *WATER quality , *ORGANIC compounds , *RATE coefficients (Chemistry) - Abstract
This work was carried out to improve the performance of an ozonation system used for wastewater treatment in the pharmaceutical industry. Ferrous sulfate was applied as a catalyst to the reaction system in order to improve the mineralization of organic matter. After this, the pH of the water was adjusted to 8.5-10 so that the process flows under alkaline conditions. Finally, O3 was injected through a Venturi tube to improve the mass exchange between gas and water. Preliminary data on the operation of the treatment system indicate a COD removal of less than 10%. The tests were carried out at full scale and the water quality variables were analyzed at different reaction times. Results allowed us to determine that an ozone dose equal to 10 g/h and 10 mg/L of Fe2+ and an initial pH of water of 9 require a total of 4.5 hours to achieve a 30.73% reduction of COD and 36.85% reduction of TOC. The results obtained at an initial pH higher than 9.5 indicate that the effectiveness of the process is lowered under this condition, which may be due to the rapid formation of insoluble Fe(OH)3, thus reducing the availability of catalyst for the formation of OH* radicals in the water. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
21. Data Quality Objectives Supporting the Environmental Soil Monitoring Program for the Idaho National Laboratory Site
- Author
-
Haney, Thomas [Idaho National Lab. (INL), Idaho Falls, ID (United States)]
- Published
- 2016
- Full Text
- View/download PDF
22. Fitorremediación de aguas residuales domésticas utilizando las especies Eichhornia crassipes, Nymphoides humboldtiana y Nasturtium officinale
- Author
-
Rosmery Yakelini Ayala Tocto, Edith Calderón Ordoñez, Jesús Rascón Barrios, Victor Hugo Gomez Ramirez, and Roicer Collazos Silva
- Subjects
Tratamiento biológico ,especies acuáticas ,DBO ,DQO ,coliformes totales ,coliformes fecales ,aguas residuales ,Agriculture (General) ,S1-972 ,Environmental sciences ,GE1-350 - Abstract
En la presente investigación se implementó un sistema de fitorremediación a escala de laboratorio o piloto con la finalidad de evaluar la eficiencia de remoción de contaminantes de las especies Eichhornia crassipes, Nymphoides humboldtiana y Nasturtium officinale, integrado por cuatro sistemas de tratamiento de flujo discontinuo o también llamado por tandas. Este consta de un estanque para cada sistema, el cual simula una laguna pequeña con agua estancada. En estos sistemas se cultivaron plantas como el jacinto de agua (Eichharnia crassipes), ninfoides sudamericana (Nymphoides humboldtiana), berro de agua (Nasturtium officinale). El cuarto sistema consistió en un estanque sin planta acuática al cual se le llamó sistema de control o testigo. El agua residual a tratar se obtuvo de la quebrada de Santa Lucía, donde la población descarga su agua residual. Para determinar la remoción de contaminantes se realizaron evaluaciones cada 15 días, por cuatro veces, para lo cual se analizaron parámetros fisicoquímicos y microbiológicos como: temperatura, pH, turbidez, sólidos totales, demanda química de oxígeno (DQO), demanda bioquímica de oxígeno (DBO5), coliformes totales y fecales. Los resultados muestran que la calidad del efluente tratado cumple en su mayoría con los límites máximos permisibles establecidos en la legislación peruana, obteniéndose un mayor porcentaje de eficiencia de remoción de contaminantes por la especie Eichhornia crassipes. Sin embargo, en cuanto a remoción de parámetros físicos y microbiológicos los mejores datos los arrojó la especie Nymphoides humboldtiana, y en cuanto a los parámetros químicos con DBO y DQO fue la especie Eichhornia crassipes la que obtuvo una mayor eficiencia para la remoción de materia orgánica.
- Published
- 2019
- Full Text
- View/download PDF
23. Monocultivos y consorcios bacterianos con aplicación en la asimilación de nutrientes de interés ambiental.
- Author
-
Pérez-Bou, Lizandra, Carballo-Valdés, María E., Sardiñas-del Río, Jasmany H., Martínez-Sardiñas, Armando, Enrique Cruz-Arias, Mario, and Salgado-Bernal, Irina
- Subjects
- *
WATER purification , *WASTEWATER treatment , *SEWAGE , *POLLUTANTS , *CHEMICAL oxygen demand , *BIOLOGICAL nutrient removal - Abstract
The dumping of large polluted domestic wastewater is one of the main problems associated to the inadequate use of hydric resources by humans. Different physical and chemical technologies have been applied for water treatment. Nevertheless the use of biological systems, in special the microorganisms, has been extensively developed in recent years due to its various advantages. In present research organic matter, nitrogen and phosphorus removal by bacterial monocultures and consortia was evaluated from simulated domestic sewage. Three bacteria strains were used: Bacillus subtilis (AL-25), Bacillus cereus (AL-30) and Micrococcus sp. (AL-138). Their capacities were determined for different carbon source assimilation, proteolytic and lipolytic activities, and phosphate and ammonium removal. Taking into account these previous results, four consortia were designed. The feasibility of using consortia CMB3 and CMB4 in the mixed removal of nutrients was determined in a simulated domestic wastewater with removal values higher than 88 %. The monocultures of Bacillus cereus (AL-30) and Micrococcus sp. (AL-138)presented high percentages of COD (Chemical Oxygen Demand) and phosphate removal, respectively. These values were similar or higher than those reached by the consortia; for this reason they can constitute an alternative for wastewater treatment with these pollutants. The potentialities showed by these bacterial biomasses make them attractive candidates for future application on wastewater treatment systems for the elimination of these pollutants. [ABSTRACT FROM AUTHOR]
- Published
- 2021
24. La demanda química de oxígeno con el procedimiento APHA/AWWA/WEF 5220 D para rango alto adaptado a microescala.
- Author
-
Morales-Mejía, Julio César, Vargas-Martínez, María Gabriela, and Medina-Camps, Javier
- Subjects
SILVER catalysts ,PIPETTES ,DIGESTION ,SULFATES ,TUBES ,CHEMICAL oxygen demand ,MERCURY - Abstract
Copyright of Tecnología y Ciencias del Agua is the property of Instituto Mexicano de Tecnologia del Agua (IMTA) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
25. Análisis de la descarga de aguas grises por la Cafetería del Edificio N. º 1 de la Universidad Tecnológica de Panamá
- Author
-
Ángel Credidio, David De Gracia, Evelin García, Dalys Villarreal, and Erick Vallester
- Subjects
calidad del agua ,sistema de tratamiento de aguas residuales ,descarga de aguas residuales ,dqo ,dbo5 ,Science (General) ,Q1-390 - Abstract
El tratamiento de aguas residuales es de vital importancia para evitar vulnerar nuestros recursos hídricos. Las aguas grises son un tema que muchas veces es pasado por alto, ya que se piensa que su capacidad de contaminación no es de gran significancia. Sin embargo, hay que tener presente, que estas impactan de manera directa y negativa al ambiente. Sus componentes principales, como la materia orgánica, las grasas, aceites y detergentes, causan un incremento en los Sólidos Suspendidos (SS), la Demanda Química de Oxígeno (DQO), y al mismo tiempo en la Demanda Bioquímica de Oxígeno (DBO). Por esta razón se han aplicado diferentes metodologías para el análisis de los parámetros de calidad del agua, tales como: los SS, la DQO y la DBO. Resultando altas concentraciones que sobrepasan los límites máximos permitidos (LMP) por el Reglamento Técnico DGNTICOPANIT 35-2000 para los S.S 395 mg/L, 1224.67 mgO2/L para la DQO y 1102.00 mg/L para la DBO [3]. Además, se logró determinar el índice de Biodegradabilidad para este efluente, dando como resultado 0.92 considerándose alto según la escala utilizada, por lo que se prevé que su tratamiento sea fácil y rápido.
- Published
- 2018
- Full Text
- View/download PDF
26. Análisis comparativo de modelos cinéticos para un Filtro Biológico sin recirculación con medio de soporte en Luffa Cylindrica para el tratamiento de aguas residuales combinadas (domésticas y pecuarias)
- Author
-
Juan Pablo Rodriguez Miranda, Sindy Yohana Castillo Ruiz, and Diana Carolina Rubiano Castro
- Subjects
Filtro biológico ,DQO ,agua residual ,Luffa cilíndrica ,eficiencia ,History of scholarship and learning. The humanities ,AZ20-999 ,Science (General) ,Q1-390 ,Social sciences (General) ,H1-99 - Abstract
El presente artículo considera un análisis de los diferentes modelos cinéticos para la estabilización de la materia orgánica en un filtro biológico con lecho en Luffa cylindrica, en donde el modelo que más influyó en la cinética con el modelo matemático expuesto por Velz estableció un promedio la constante cinética de 0,116 (d-1). En cuanto a la remoción de la materia orgánica, se obtuvieron resultados de eficiencia en donde se alcanzaron valores entre 85%, 76%, 55%.
- Published
- 2018
- Full Text
- View/download PDF
27. Evaluación de la Moringa oleifera en el tratamiento de aguas con alta turbidez y carga orgánica.
- Author
-
Mejía Carrillo, P. W., Urquia Collantes, K., Cabello Torres, R. J., and Valdiviezo Gonzales, L. G.
- Abstract
Copyright of Ingeniería del Agua is the property of Universidad Politecnica de Valencia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
28. Remocion de contaminantes del residual lacteo por electrocoagulacion con electrodos de aluminio.
- Author
-
Magaña-Irons, Lisset, Rojas-Vargas, Armando, González-Díaz, Yudith, and Ojeda-Armaignac, Elaine
- Subjects
- *
ALUMINUM electrodes , *COLOR removal in water purification , *CHEMICAL oxygen demand , *FACTORIAL experiment designs , *WATER quality , *CENTRIFUGATION - Abstract
In the present work, the electrocoagulation was studied experimentally to reduce the pollutant load discharged into the environment of the liquid residual from the dairy industry, for this purpose an electrochemical cell was used on a laboratory scale, constituted by a discontinuous cylindrical reactor, equipped with two aluminum electrodes. The influence of pH, the current density and the most adequate electrolysis time in the electrocoagulation process was determined, using the factorial experimental design 2k-1 with a central level. It was demonstrated that at the current density of 3,39 mA / cm², pH of 9,5 and electrolysis time of 5 minutes, it is possible to raise the quality of the water before its discharge, using later on the unit operations of sedimentation, centrifugation and filtration. To comply with the requirements of the Cuban Standard NC27:2012 there were obtained: 93 % removal of Chemical Oxygen Demand (COD), 97 % of color removal; turbidity less than or equal to 10 NTU and conductivity of 7,8 mS/cm. The electricity consumption was 2,25-10-5 kW⋅h. [ABSTRACT FROM AUTHOR]
- Published
- 2020
29. Proposta de Ferramenta Estatística para Controle de Estações de Tratamento de Efluentes Industriais.
- Author
-
do Nascimento Dias, Karine Marinho and Giordano, Gandhi
- Subjects
- *
INDUSTRIAL wastes , *WATER purification , *SEWAGE disposal plants , *QUALITY control charts , *BODIES of water , *ELECTRONIC spreadsheets , *ENVIRONMENTAL permits - Abstract
Industrially, water can be used at different steps, such as incorporation into the product, washing machines, pipes, floors, among others. With the need to control effluents before being released to water bodies, according to Brazilian legislation, it is necessary to treat industrial effluents. In this sense, industrial wastewater treatment plants must monitor the quality standards established by laws in relation to industrial effluent, to meet the restrictions and limits imposed by the environmental license. Often the control of the station is done through several spreadsheets and reports in an individualized and non-systematized way. The objective of this work is the production of a statistical tool capable of analyzing, through the indirect measurement of organic matter present in the effluent, the efficiency of an industrial effluent treatment station in relation to BOD and COD, using a condominium case study. of food industries in the city of Rio de Janeiro. The methodology was based on the application of a statistical tool using the EXCEL® software, through the following steps: imputation of the original data, exploratory descriptive analysis, application of control charts, analysis of the station's efficiency, production of low efficiency alert, presentation results and generating a final report. As a conclusion, the result was favorable in relation to the objectives of the work, allowing the user to have, in just one program, the compilation of indirect analyzes of organic matter and generation of the station's efficiency. In relation to the case study, the station showed efficiency above 97% on all analyzed days. Below 98% there were four BOD results and one COD result. The system identified the date of these analyzes, as well as filtered the results themselves, reaching the proposed objectives. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
30. Aplicación de foto fenton (VIS) para la remoción de sulfuros y DQO en aguas residuales de curtiembre.
- Author
-
Agudelo Valencia, Rafael Nikolay, Ovalle González, Diana Paola, and Rodriguez Rodriguez, Luis Felipe
- Abstract
Copyright of Revista Luna Azul is the property of Universidad de Caldas and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
31. Use of microalgae of Chlorophyta division in the biological treatment of acid drains of coal mines
- Author
-
Darkys Devia Torres, Sindy Cáceres Sepúlveda, Alba Lucía Roa, Jonh Hermogenes Suárez Gelvez, and Néstor Andrés Urbina Suárez
- Subjects
Aguas residuales ,Biomasa ,Metales pesados ,DQO ,Constantes cinéticas ,Biotechnology ,TP248.13-248.65 - Abstract
The environmental impact caused by coal mining wastewater is significant due to the pollution load, usually represented in high concentrations of suspended solids, metals (mainly iron) and other trace elements and low pH values. The aim of this study was to evaluate the efficiency of a biological treatment system using microalgae belonging to the Chlorophyta division, for the removal of contaminants from the wastewater from a mine owned by Coal North Energy S.A.S. At the end of treatment, it was possible to remove up to 66.67% of total iron, 46.67% for chloride and 95.1% for Chemical Oxigen Demand.
- Published
- 2017
- Full Text
- View/download PDF
32. Manejo y reutilización de la orina humana como fertilizante en plantas de maíz
- Author
-
Ricardo Augusto Reyes Arana
- Subjects
Saneamiento ,desechos humanos ,bioensayo ,aguas residuales ,DBO5 ,DQO ,Technology ,Technical hydraulics ,TC160-181 ,Environmental sciences ,GE1-350 - Abstract
Este artículo presenta los resultados de un bioensayo realizado como prueba piloto para el proceso de recolección, tratamiento y aplicación de orina humana como fertilizante orgánico en plantas de maíz para determinar sus efectos. Los resultados y lecciones aprendidas del bioensayo indican que con el almacenamiento de la orina, alcanza valores de pH mayores a 8 lo que elimina la posible presencia de patógenos, y es una fuente de concentraciones de nitrógeno (N) de 3.00-7.00 g/L, fósforo (P) 0.20-0.50 g/L y potasio (K) de 0.90-4.88 g/L. Al separar la orina que corresponde al uno por ciento de las aguas residuales, se determinó el impacto de la orina sobre las mismas, al analizar los siguientes parámetros demanda bioquímica de oxígeno (DBO5), demanda química de oxígeno (DQO), nitrógeno (N), fósforo (P). La orina contribuye en un 7.11% en la demanda bioquímica de oxígeno (DBO5), 9.67% en la demanda química de oxígeno (DQO), 9.35% nitrógeno (N) y 16.37% fósforo (P) de las aguas residuales
- Published
- 2019
33. Diagnóstico del sistema de tratamiento de aguas residuales de Manta
- Author
-
Giselle Velasco T., Jorge Moncayo S., and David Chuquer S.
- Subjects
DBO5 ,DQO ,lagunas de oxidación ,materia orgánica ,tratamiento de agua residual ,Chemical technology ,TP1-1185 ,Chemistry ,QD1-999 - Abstract
Se realizó un diagnóstico de la eficiencia de remoción de contaminantes en la planta de tratamiento de aguas residuales (PTAR) de la ciudad de Manta, la cual recibe en promedio un caudal de 30798 m3d-1 de agua residual. Para ello se caracterizó fisicoquímicamente el agua durante el tratamiento, determinándose eficiencias de remoción de DBO5 del 51 % y de DQO del 56 %, valores que, al ser comparados con otras PTAR del mismo tipo, indican una pobre remoción de materia orgánica. Con respecto al efluente de descarga del sistema, se encontró que los parámetros DQO, DBO5, nitrógeno Kjeldahl y sólidos totales, sobrepasan los límites máximos permisibles de la normativa ecuatoriana. En conclusión, se demostró que el sistema requiere mantenimiento especialmente en las lagunas facultativas, ya que son las principales responsables de la disminución de la eficiencia global de remoción de contaminantes.
- Published
- 2019
- Full Text
- View/download PDF
34. Application of a direct current circuit to pick up and to store bioelectricity produced by microbial fuel cells.
- Author
-
Avilés, Daniel Gonzalo Arboleda, Barrionuevo, Oscar Fernando Núñez, Olmedo, Omar Fernando Sánchez, Piñan, Billy Daniel Chinchin, Briones, Daniel Alexander Arboleda, and Soria, Raúl Alfonso Bahamonde
- Subjects
- *
DIRECT current circuits , *MICROBIAL fuel cells , *CHEMICAL energy , *ELECTROPHYSIOLOGY , *BIOREACTORS , *ANAEROBIC bacteria - Abstract
Every year the demand for energy worldwide is increasing. There are some alternatives to reduce these problems, such as clean energy or renewable energy. A particular alternative is the microbial fuel cells. These cells are biochemical reactors that convert chemical energy into electricity. The present research evaluated the dairy serum to produce bioelectricity from micro fuel cells (MFC) that were constructed with low-cost materials and with isolated bacteria in anaerobic sediments, located in Ecuadorian national territory, producing maximum voltages of 0.830 V in the circuit and a maximum power density of 30 mW / m2. This low voltage was worked with 50 mL MFCs and with an output voltage of 300 mV. Under these conditions, a FLYBACK lift circuit isolated by the transformer was designed. This new circuit could increase the voltage from 30 mV to enough voltage to light a 2.5 V LED. Therefore, the energy produced by the MFC can be directly used to light a LED and to charge capacitors. This study shows that these MFCs, together with the designed circuit, could be used potentially to generate clean energy. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
35. ABSORCIÓN DE ACEITES Y GRASAS EN AGUAS RESIDUALES DE LAVADORAS Y LUBRICADORAS DE VEHÍCULOS UTILIZANDO ABSORBENTES NATURALES.
- Author
-
Guilcamaigua Anchatuña, Doris Ximena, Quintero Quiñonez, Nadia, Jiménez Cercado, María Eugenia, and Muñoz Naranjo, Diego
- Subjects
RICE hulls ,WASTEWATER treatment ,SEWAGE ,SUSPENDED solids ,CORN - Abstract
Copyright of 3C Tecnologia is the property of Area de Innovacion y Desarrollo, SL and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
36. Evaluación de un sistema de tratamiento de aguas residuales no domésticas para la remoción de carga orgánica en industria de bebidas no alcohólicas.
- Author
-
Velasco, F., Molano, A., and Pramparo, L.
- Subjects
- *
SOFT drinks , *WASTEWATER treatment , *ACTIVATED sludge process , *MAINTENANCE costs , *MANUFACTURING industries , *SEWAGE - Abstract
The document presented here corresponds to the evaluation of a wastewater treatment system belonging to the manufacturing industry of carbonated and non-carbonated soft drinks. The development of this study was performed through 3 samplings carried out in the months of May, July and October (where the maintenance and cleaning operations of the system were carried out in July with the purpose of observing their implications in October) and 6 different points of the treatment plant were sampled. From the obtained samples, the insitu information was determined, the presence of bionutrients, the physical and chemical characteristics, and the BOD and COD parameters, in order to interpret their performance in terms of removal of contaminating organic load, and establish the control parameters required by the current legal regulations of the country to identify the problems existing in the system, their possible causes and the approach of a recommendation as a theoretical solution to the irregularities observed. It was evidenced that the pretreatment phase has a good performance in the development of treatment activities due to its stability in temperature and pH; however, the generation of residual sludge in this phase comprises a problem that directly impacts on the cost of operation and maintenance of the treatment system. The effluent from the production plant showed that the addition of chemical agents and the generation rate of activated sludge against the aerobic conditions of the system are the greatest support that the plant has to perform the processes of degradation in organic matter. The physicochemical characterization of the wastewater helped determine whether the mechanisms belonging to the treatment train developed their unit operations under efficient conditions for the reduction of organic load. Thanks to what was observed in this study, it would be beneficial for the system to implement complementary structures to the homogenizer tank and equalizer tank, for the reduction in the production of residual sludge, since this problem when being carried from the initial structures of the treatment train entails to the loss of efficiency in the subsequent processes to this throughout the system. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
37. Evaluación de un biorreactor de manto de lodo anaerobio de flujo ascendente para el tratamiento de vinazas
- Author
-
Abumalé, Cruz-Salomó, Rocío, Meza-Gordillo, Arnulfo, Rosales-Quintero, Cristina, Ventura-Canseco, and Edna Iris, Ríos-Valdovinos
- Subjects
Aguas residuales ,vinazas ,UASB ,DQO ,Social sciences (General) ,H1-99 - Abstract
En esta investigación se presenta la evaluación de un biorreactor de manto de lodo anaerobio de flujo ascendente (UASB) de 4.4 L durante un periodo de 90 días, el cual fue alimentado con vinazas de una empresa de bebidas fermentadas provenientes de Comitán, Chiapas. Se investigó principalmente la eficiencia de la remoción de la demanda química de oxígeno (DQO) y la estabilidad del reactor con respecto al factor alfa (α) y potencial de hidrógeno (pH). La eficiencia de remoción de la DQO fue de 90 %. Durante el estudio, se mantuvo un sistema estable con α =0.28 y pH=7.1.
- Published
- 2016
- Full Text
- View/download PDF
38. EFECTOS DE Eisenia foetida y Eichhornia crassipes EN LA REMOCIÓN DE MATERIA ORGÁNICA, NUTRIENTES Y COLIFORMES EN EFLUENTES DOMÉSTICOS
- Author
-
Lissette Vizcaíno Mendoza and Natalia Fuentes Molina
- Subjects
DBO ,DQO ,humedales construidos ,lombrifiltro ,tratamiento biológico ,Agriculture (General) ,S1-972 ,Medicine (General) ,R5-920 ,Biology (General) ,QH301-705.5 - Abstract
Con el objeto de conocer la capacidad depuradora de un sistema biológico potencialmente aplicable como alternativa para la reducción de la carga contaminante de efluentes residuales domésticos del municipio de San Juan del Cesar, se evaluó, a escala de laboratorio, el efecto del tratamiento con Eisenia foetida y Eichhornia crassipes, sobre la remoción de materia orgánica, de nutrientes y de patógenos. Durante un mes, se aplicaron tres tratamientos: T1: E. foetida (biofiltro dinámico aerobio de flujo vertical); T2: E. crassipes (sistema de flujo horizontal con plantas flotantes) y T3: E. foetida + E. crassipes (sistema en serie), empleando tiempos de retención hidráulica de 24 h y caudales de 0,125L/min (E. foetida) y 0,020L/min (E. crassipes). Se determinaron las concentraciones de sólidos totales (ST), sólidos suspendidos totales (SST), turbidez, Demanda Bioquímica de Oxígeno (DBO5), Demanda Química de Oxígeno (DQO), Nitrógeno Total, fosfatos, coliformes totales y Escherichia coli, en 30 muestras analizadas (10 para cada sistema). T1 fue más eficiente en la remoción de DQO 69,2%, T2 eliminó el 100% de SST, mientras que T3 reportó las mejores eficiencias de remoción, para la demás variables analizadas. Existen diferencias significativas p
- Published
- 2016
39. DQO Summary Report for 105-N/109-N Interim Safe Storage Project Waste Characterization
- Author
-
Lee, T
- Published
- 2005
- Full Text
- View/download PDF
40. Data Quality Objectives Summary Report - Designing a Groundwater Monitoring and Assessment Network for the 100-BC-5 and 100-FR-3 Operable Units
- Author
-
Chou, Charissa
- Published
- 2003
- Full Text
- View/download PDF
41. Data Quality Objective Summary Report for Waste Disposition CY2003 Waste Management Area C RCRA Wells
- Author
-
THOMAS, G
- Published
- 2003
- Full Text
- View/download PDF
42. Data Quality Objective Summary Report for Waste Disposition CY2003 Waste Management Area A-AX RCRA Wells
- Author
-
THOMAS, G
- Published
- 2003
- Full Text
- View/download PDF
43. Data quality objectives summary report for establishing a RCRA/CERCLA/AEA integrated 200 west and 200 east area groundwater monitoring network
- Author
-
BYRNES, M
- Published
- 2003
- Full Text
- View/download PDF
44. Implementación de un reactor tipo UASB para el tratamiento del aguamiel
- Author
-
Ana Rufina Herrera Soto
- Subjects
Beneficio húmedo ,potencial de hidrógeno ,alcalinidad ,DQO ,DBO5 ,Technology ,Technical hydraulics ,TC160-181 ,Environmental sciences ,GE1-350 - Abstract
Este artículo presenta los resultados del trabajo de investigación cuyo objetivo fue evaluar la posibilidad de utilizar un reactor anaeróbico de flujo ascendente (UASB por sus siglas en inglés) para tratar el aguamiel (agua residual que se obtiene luego de utilizarla para lavar, despulpar y fermentar los granos de café), aumentando su potencial de hidrógeno y disminuyendo su carga orgánica. El reactor, diseñado a escala laboratorio, funcionó con un tiempo de retención de 54.67 horas. El aguamiel que ingresaba en él tenía un potencial de hidrógeno promedio de 3.51 unidades, y al salir del reactor presentaba un valor promedio de 3.74 unidades, lo cual significa que el tratamiento fue capaz de aumentar el potencial de hidrógeno del aguamiel en un 6%, lo cual no fue suficiente para alcanzar un potencial de hidrógeno que pudiera ser considerado como neutro.
- Published
- 2018
45. Data Quality Objectives Summary Report - Designing a Groundwater Monitoring Network for the 200-BP-5 and 200-PO-1 Operable Units
- Author
-
Lindberg, Jon
- Published
- 2002
- Full Text
- View/download PDF
46. Evaluation of electrocoagulation in the post-treatment of anaerobic wastewater of slaughterhouse and packing plant
- Author
-
Flavia Manente da Silva, Fábio Orssatto, Eduardo Eyng, Laercio Mantovani Frare, Ilton José Baraldi, and Leandro Fleck
- Subjects
medicine.medical_treatment ,custo ,COD ,Aquatic Science ,Electrocoagulation ,law.invention ,law ,cost ,medicine ,GE1-350 ,Statistical analysis ,turbidez ,Turbidity ,DQO ,Effluent ,General Environmental Science ,Electrolysis ,Public Health, Environmental and Occupational Health ,cod ,Pulp and paper industry ,turbidity ,color ,Environmental sciences ,Wastewater ,cor ,Environmental science ,Post treatment ,Anaerobic exercise - Abstract
The demand for food production brings with it the increase of effluent generation, which represents a great problem for slaughterhouses, since effluents contain higher organic load, requiring adequate treatment to decrease environmental impacts. This study examines an alternative to solve this problem: the application of electrocoagulation in the treatment of anaerobic slaughterhouse and packing plant effluents, as this promising technique is both compact and robust. The removal of color, COD and turbidity was analyzed, and the operational cost was calculated. To optimize the process, the CCRD (central composite rotatable design) methodology was used with two independent variables: electric current density and electrolysis time, obtaining a complete factorial of 2² with 4 axial points and 4 repetitions at the central point. The most expressive removals were: 87%, 80% and 76% for color, COD and turbidity, respectively, the lower operational cost obtained was 0.12 US$.m-3. The statistical analysis allowed obtaining valid mathematical models for color removal and cost and, through the analysis of desirability, it was found that for current density of 8 mA.cm-2 and time of 20 minutes it is possible to maximize color removal (84%) and minimize the cost (0.21 US$.m-3). Resumo A demanda por produção alimentícia traz consigo o aumento da geração de efluentes líquidos, que representa um grande problema para os frigoríficos, uma vez que tais efluentes contém alta carga orgânica, necessitando tratamento adequado para minimizar os impactos ambientais. Uma alternativa para resolver este problema é a aplicação da eletrocoagulação no tratamento de efluente anaeróbio de abatedouro e frigorífico de suínos, por ser uma técnica compacta e robusta. Foram analisadas as remoções de cor, DQO e turbidez, além do custo para o tratamento, sendo que para otimizar o processo utilizou-se a metodologia DCCR (delineamento composto central rotacional) com duas variáveis independentes: densidade de corrente elétrica e tempo, obtendo um fatorial completo 2² com 4 pontos axiais e 4 repetições no ponto central. As remoções mais expressivas foram de: 87%, 80% e 76%, para cor, DQO e turbidez, respectivamente, o menor custo obtido foi 0.12 US$.m-3. A análise estatística permitiu obter modelos matemáticos válidos para a remoção da cor e para o custo e, por meio da análise de desejabilidade, encontrou-se que para densidade de corrente de 8 mA.cm-2 e tempo de 20 minutos é possível maximizar a remoção da cor (84%) e minimizar o custo (0,21 US$.m-3).
- Published
- 2021
- Full Text
- View/download PDF
47. Extension and Enhancement Methods for Setting Data Quality Objectives
- Author
-
Goodman, D
- Published
- 2000
- Full Text
- View/download PDF
48. Nictemeral Variation of Physical Chemical and Biological Parameters of Ribeirão das Cruzes, Araraquara-SP
- Author
-
Vitor Rocha Santos, Daniel Jadyr Leite Costa, and Denilson Teixeira
- Subjects
Variação nictemeral ,DBO ,DQO ,Education (General) ,L7-991 ,Special aspects of education ,LC8-6691 - Abstract
Improper use of water, its degradation and irregular distribution can affect the quantity and quality needed for future generations, as well as create conflicts of interest between the industrial, urban and agricultural segments. In this context, it is of great importance the realization of studies on the quality of the hydric resources based on the analysis of temporal variation of limnological parameters. This study was conducted in the sub-basin of Ribeirão das Cruzes, which contributes to the water supply of the city of Araraquara (SP) around 30% of all water captured and offered to the population. The objective of this research was to compare the water quality of river upstream and downstream of effluent discharge from a local treatment station in a 24 hour period (diurnal cycle variation). Data collection, comprising the period of one day, was done in order to observe the dynamics of operation and range of variation of the ecological processes in the studied system. The parameters analyzed showed significant variations in the sections of the upstream and downstream from the effluent discharge. With the nictemeral analysis it is evident the influence of effluents on the the waters of Ribeirão das Cruzes, especially during certain periods of the day.
- Published
- 2015
- Full Text
- View/download PDF
49. Anaerobic removal of the brl direct blue dye in Upflow Anaerobic Sludge Blanket (UASB) with activated carbon
- Author
-
Christian Zavala-Rivera, Alex Paul Dueñas Gonza, Ronald Eleazar Huarachi Olivera, Ursulo Avelino Yapo Pari, Rodrigo Mendoza-Puertas, Ronny Lázaro-Puma, and Edwin Bocardo-Delgado
- Subjects
Bacterial ,consortium ,removal ,COD ,IPRS ,SSV ,Consorcio bacteriano ,remoción ,DQO ,PIRS ,Biotechnology ,TP248.13-248.65 - Abstract
In this research the brl direct blue dye was used for anaerobic removal with a bacterial consortium of industrial effluents from Industrial Park Río Seco (IPRS), Arequipa, Peru; in an anaerobic reactor of UASB Upflow with activated carbon. The reactor had a capacity of 14.4 L with sludge and activated carbon of 40% of volume, with an organic load of 6 Kg COD/m3•dia and a hydraulic retention time of 1 day with an upward flow. The objective was to measure the efficiency of the anaerobic removal of coloring in a time of 28 days. The results showed an increase of 41% of the solids suspended volatile (SSV) 12894 mg•L-1 up to 21546 mg•L-1 under the conditions of the experiment, with a removal of 57% of the chemical demand of oxygen (COD) from 484 mg•L-1 to 122 mg•L-1 and a removal of 87% of the dye Blue direct the 69.61 brl mg•L-1 to 9 mg•L-1. Results with activated charcoal granular only, they showed a removal of 61% of the dye Blue direct 70.67 brl mg•L-1 to 27.83 mg•L-1 at 28 days.
- Published
- 2015
- Full Text
- View/download PDF
50. Elimination of chemical oxygen demand from domestic residual water by electrocoagulation with aluminum and iron electrodes.
- Author
-
Aguilar Ascón, Edwar Alejandro
- Subjects
CHEMICAL oxygen demand ,ELECTROCOAGULATION (Chemistry) ,IRON electrodes - Abstract
Copyright of Revista Ambiente e Água is the property of Revista Ambiente e Agua and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.