5 results on '"Conti, Claudio de Carvalho"'
Search Results
2. Three-phase flow meters based on X-rays and artificial neural network to measure the flow compositions
- Author
-
Salgado, César Marques, primary, Dam, Roos Sophia de Freitas, additional, Conti, Claudio de Carvalho, additional, and Salgado, William Luna, additional
- Published
- 2021
- Full Text
- View/download PDF
3. ENVIRAD – A Database Integration for Environmental Samples Radiological Data
- Author
-
Gonzalez, Sergio De Albuquerque, primary, Silva, Tadeu Augusto de Almeida, additional, Conti, Claudio De Carvalho, additional, Osvath, Iolanda, additional, Ramadan, Hussein, additional, and Bartocci, Jean, additional
- Published
- 2020
- Full Text
- View/download PDF
4. Análise multielementar usando técnicas de XRF em cérebros de camundongos suíços utilizando o modelo experimental da Doença de Alzheimer induzida por oligômeros β-amiloide
- Author
-
Almeida, Danielle Santos de, Souza, Amanda Santos de, Anjos, Marcelino José dos, Silva, Ademir Xavier da, Conti, Claudio de Carvalho, and Lopes, Ricardo Tadeu
- Subjects
ENGENHARIAS::ENGENHARIA NUCLEAR::APLICACOES DE RADIOISOTOPOS [CNPQ] ,Oligômeros b-amiloide ,Fluorescência ,Espectroscopia de raio X ,Análise Multielementar ,Doença de Alzheimer - Abstract
Submitted by Moreno Barros (moreno@ct.ufrj.br) on 2020-10-24T17:46:57Z No. of bitstreams: 1 DanielleSantosDeAlmeida.pdf: 5897168 bytes, checksum: 54fee4ade35ce18f074d4acb14e753b0 (MD5) Made available in DSpace on 2020-10-24T17:46:57Z (GMT). No. of bitstreams: 1 DanielleSantosDeAlmeida.pdf: 5897168 bytes, checksum: 54fee4ade35ce18f074d4acb14e753b0 (MD5) Previous issue date: 2019-02 A doença de Alzheimer (DA) é uma doença progressiva com características patológicas de perda neuronal e sináptica. Tem sido cada vez mais reconhecido que o surgimento da DA está ligado à função e aos níveis de íons metálicos. Assim, estes metais podem interagir com o peptídeo β-amiloide (Aβ) resultando na deposição de Aβ e na formação de placas. No entanto, nenhum estudo analisando os efeitos da injeção de oligômeros solúveis de β-amiloide (AβOs) na homeostase de elementos em camundongos foi desenvolvido. Neste estudo, a concentração e distribuição de metais no cérebro de camundongos suíços foram avaliadas através das técnicas TXRF e μSRXRF. Para isto, três grupos de cada sexo foram estudados e, para induzir a DA experimental, os animais receberam injeções icv com 10 pmol de AβOs (DA10), 100 pmol de AβOs (DA100) e PBS (controle). Os resultados utilizando a técnica de TXRF mostraram diferenças na concentração elementar em algumas regiões do cérebro quando comparou-se os grupos DA10 e DA100 com o grupo controle, tanto nas fêmeas quanto nos machos. Por outro lado, os resultados dos grupos DA100 utilizando a μSRXRF quando comparados com o grupo controle mostraram redução dos níveis de ferro, cobre e zinco. As alterações encontradas nas duas técnicas sugerem que os AβOs atuam rapidamente e diferentemente entre os sexos, antes mesmo da formação de placas amiloides, explicando, possivelmente, os déficits cognitivos independentemente da presença de placas insolúveis. Este estudo ajudou a entender que as alterações na concentração elementar podem ser influenciadas pelo AβOs. Alzheimer’s disease (AD) is a progressive and irreversible disorder whose pathological features include neuronal and synaptic loss. The imbalance in the homeostasis of metal ions leads to neuronal death. The metal ions may have an important impact on protein misfolding and the progression of the neurodegenerative process. However, no study analyzing the effects of single injection of β-amyloid soluble oligomers (AβOs) in the elements’ homeostasis in mice was developed. In this study, in order to evaluate the concentration and distribution of metals in brain of Swiss mice, were used TXRF and μSRXRF techniques. For this, three groups of both genders were studied and icv injections of 10 pmol of AβOs (AD10 group), 100 pmol of AβOs (AD100 group) and an equivalent volume of vehicle (control group) were made. The TXRF results showed differences in the elemental concentration in some brain regions between AD groups and control group, in both males and females. On the other hand, using the μSRXRF to compare the AD groups to the control group it was verified a decrease of iron, copper and zinc levels in the AD100 group. These alterations found with the two techniques suggest that AβOs acts quickly, even before the amyloid plaques’ formation, explaining cognitive deficits independently of amyloid plaques. This study helps to understand that this modification on elemental concentration can be influenced by AβOs.
- Published
- 2019
5. Methodology for the qualification of industrial radioscopy equipment
- Author
-
Beserra, Marcela Tatiana Fernandes, Conti, Claudio de Carvalho, Oliveira, Davi Ferreira de, Jesus, Edgar Francisco Oliveira de, Pereira, Gabriela Ribeiro, and Lopes, Ricardo Tadeu
- Subjects
Ponto focal ,Radioscopia industrial ,Qualificação ,Sistemas cinemáticos ,ENGENHARIAS::ENGENHARIA NUCLEAR [CNPQ] ,Raios X - Abstract
Submitted by Marlon Silva (marlonviniciuspacheco@gmail.com) on 2021-02-17T16:20:52Z No. of bitstreams: 1 MarcelaTatianaFernandesBeserra.pdf: 6843666 bytes, checksum: 5c38f1313f3b3871e06eada35e1375ab (MD5) Made available in DSpace on 2021-02-17T16:20:52Z (GMT). No. of bitstreams: 1 MarcelaTatianaFernandesBeserra.pdf: 6843666 bytes, checksum: 5c38f1313f3b3871e06eada35e1375ab (MD5) Previous issue date: 2018-09 A Radioscopia Industrial é um ensaio não destrutivo empregando radiação ionizante, principalmente do tipo X, que fornece informações em tempo real sobre imperfeições de um corpo de prova, apresentando-se como potencial solução para detectabilidade de falhas na melhoria dos produtos e processos de produção. O objetivo deste estudo multidisciplinar foi apresentar uma metodologia para avaliação da performance das partes componentes de um equipamento de Radioscopia Industrial. Foram empregados algoritmos de Visão Computacional desenvolvidos em MATLAB, proposto o uso de padrões de teste alternativos, desenvolvidos phantoms para avaliação da performance dos sistemas, assim como uso de padrões corporificados e equipamentos de medição rastreáveis. A metodologia foi aplicada a equipamentos de Radioscopia Industrial contendo Intesificador de Imagem e Flat Panel. Foram realizados ensaios experimentais, sendo possível a avaliação de desempenho destes sistemas segundo critérios definidos de acordo com normas e especificações. Os resultados da validação da performance dos subsistemas permitiram avaliações mais objetivas e robustas, contribuindo com as orientações sugeridas pela norma ASTM E1411-16 relacionadas a qualificação de equipamentos de Radioscopia Industrial. Industrial Radioscopy is a non-destructive testing method that employ ionizing radiation mainly X-rays. It provides real-time information on any imperfections found on a given specimen, thus offering a potential solution for the detection of failures and the improvement of products and production processes. The objective of this multidisciplinary study is to present a methodology for evaluating the performance of the component parts of Industrial Radioscopy equipment. The Computational Vision algorithms were developed in MATLAB, proposed the use of alternative testing standards, developed phantoms to evaluate systems performance, employed standards and traceable measurement equipment. The methodology was applied to Industrial Radioscopy equipment with Image Intensifier and Flat Panel detectors. Experimental tests were performed and were able to evaluate the performance of these systems under several criteria defined according to standards and specifications. The subsystem performance validation results enabled a more objective and robust evaluation, thus contributing to the guidelines suggested by ASTM E1411-16 related to the qualification of Industrial Radioscopy equipment.
- Published
- 2018
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.