10 results on '"Circa-Dose Study Investigators"'
Search Results
2. Prevalence and clinical impact of spontaneous and adenosine-induced pulmonary vein reconduction in the Contact-Force vs. Cryoballoon Atrial Fibrillation Ablation (CIRCA-DOSE) study
- Author
-
Peter Leong-Sit, Mariano Badra-Verdu, Laurent Macle, Atul Verma, Circa-Dose Study Investigators, Marc W. Deyell, Umjeet Jolly, Jason G. Andrade, Jean Champagne, John L. Sapp, Marc Dubuc, Paul Khairy, and Stanley Nattel
- Subjects
Male ,medicine.medical_specialty ,Adenosine ,Radiofrequency ablation ,Vasodilator Agents ,medicine.medical_treatment ,Vascular Remodeling ,030204 cardiovascular system & hematology ,Cryosurgery ,Pulmonary vein ,law.invention ,Lesion ,03 medical and health sciences ,0302 clinical medicine ,Heart Conduction System ,law ,Physiology (medical) ,Internal medicine ,Atrial Fibrillation ,Prevalence ,medicine ,Dormant conduction ,Humans ,Single-Blind Method ,Prospective Studies ,030212 general & internal medicine ,Implantable cardiac monitor ,business.industry ,Atrial fibrillation ,Middle Aged ,Ablation ,medicine.disease ,Pulmonary Veins ,Cardiology ,Female ,medicine.symptom ,Cardiology and Cardiovascular Medicine ,business ,Follow-Up Studies ,medicine.drug - Abstract
Use of intraprocedural observation and pharmacologic challenges have been proposed as means to differentiate permanent pulmonary vein (PV)-left atrial conduction block from inadequate ablation lesions.The purpose of this study was to determine the prevalence and clinical impact of spontaneous and adenosine-provoked reconnection using contemporary atrial fibrillation (AF) ablation technologies.The CIRCA-DOSE (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration) study enrolled 346 patients with paroxysmal AF and randomized them to contact force-guided radiofrequency ablation (CF-RF) or cryoballoon ablation. Patients underwent provocative testing with adenosine after a 20-minute observation period. All patients received an implantable cardiac monitor for arrhythmia monitoring.Spontaneous reconnection was observed in 5.4% of PVs (71/1318) during the 20-minute postprocedure observation period, and dormant conduction was elicited in 5.7% of PVs (75/1318). Both spontaneous reconnection and dormant conduction were more common after CF-RF compared to cryoballoon ablation (P = .03 and P.0001, respectively). Acute PV reconnection (spontaneous or adenosine-provoked) was associated with a significantly higher incidence of recurrent atrial tachyarrhythmia in the cryoballoon group (hazard ratio [HR] 2.39; 95% confidence interval [CI] 1.44-3.96; P = .0007) but not in the CF-RF group (HR 1.47; 95% CI 0.84-2.58; P = .16). In the absence of acute reconnection, the freedom from recurrent arrhythmia did not differ between groups (HR 0.95; 95% CI 0.6057-1.495; P = .83).Patients without spontaneous or adenosine-provoked reconnection had better outcomes compared to those with acute PV reconnection, suggesting that efforts should be directed toward ensuring an ideal ablation lesion at the first attempt in order to achieve durable PV isolation.
- Published
- 2020
3. Clinical assessment of AF pattern is poorly correlated with AF burden and post ablation outcomes: A CIRCA-DOSE sub-study
- Author
-
Jason G. Andrade, James McKinney, Christian Steinberg, Nathaniel M. Hawkins, Robert R J Yao, Benedict Glover, Clarence Khoo, Circa-Dose Study Investigators, Christopher C. Cheung, Paul Khairy, Krishnan Ramanathan, Marc W. Deyell, Christina Luong, Jacques Rizkallah, Umjeet Jolly, Jean-Marc Raymond, Atul Verma, Andrew C.T. Ha, and Laurent Macle
- Subjects
medicine.medical_specialty ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,law.invention ,Electrocardiography ,03 medical and health sciences ,0302 clinical medicine ,Randomized controlled trial ,Recurrence ,law ,Internal medicine ,Atrial Fibrillation ,Cardiac rhythm monitoring ,Humans ,Medicine ,Prospective Studies ,030212 general & internal medicine ,Implantable cardiac monitor ,Trial registration ,business.industry ,Atrial fibrillation ,Cryoablation ,medicine.disease ,Ablation ,Treatment Outcome ,Pulmonary Veins ,Monitoring data ,Catheter Ablation ,Cardiology ,Cardiology and Cardiovascular Medicine ,business - Abstract
Contemporary guidelines recommend that atrial fibrillation (AF) be classified into paroxysmal and persistent AF based on clinical assessment, with these categorizations forming the basis of therapeutic recommendations. While pragmatic, clinical assessment may introduce misclassification errors, which may impact treatment decisions. We sought to determine the relationship between AF classification, baseline AF burden, and post-ablation arrhythmia outcomes.The current study is a sub-analysis of a prospective, parallel-group, multicenter, single-blinded randomized clinical trial. All 346 patients enrolled in CIRCA-DOSE received an implantable cardiac monitor a median of 72 days prior to ablation. AF was classified as low burden paroxysmal, high burden paroxysmal, or persistent based on clinical assessment prior to device implantation. Prior to ablation patients were re-classified using the same definitions based on device monitoring data. Correlation between classifications, AF burden, and post-ablation arrhythmia outcomes were assessed.There was poor agreement between clinical and device-based AF classification (Cohen's kappa: 0.192). AF classification derived from pre-ablation continuous monitoring reflected baseline and post-ablation AF burden with greater accuracy and with less overlap between the AF classes (P 0.01 for all categorical comparisons). Patients objectively classified as "Low Burden" paroxysmal by continuous monitoring data had significantly greater freedom from recurrent AF/AT/AFL compared to those classified as "High Burden" paroxysmal (hazard ratio [HR] 0.57 for AF/AT/AFL recurrence) or persistent AF (HR 0.19 for AF/AT/AFL recurrence).Classification of AF pattern based on pre-ablation continuous cardiac rhythm monitoring better predicted AF burden and freedom from recurrent AF post ablation. Despite the use of standardized definitions, classification of AF based on clinical assessment did not predict baseline AF burden, post ablation AF burden, or freedom from recurrent AF post ablation.ClinicalTrials.govNCT01913522.
- Published
- 2020
4. Prevalence and outcome of early recurrence of atrial tachyarrhythmias in the Cryoballoon vs Irrigated Radiofrequency Catheter Ablation (CIRCA-DOSE) study
- Author
-
Marc W. Deyell, Christian Steinberg, Marc Dubuc, Hugh Calkins, Laurent Macle, John L. Sapp, Peter Leong-Sit, Jean Champagne, Mariano Badra-Verdu, Circa-Dose Study Investigators, Lawrence Sterns, Paul Khairy, and Jason G. Andrade
- Subjects
Male ,medicine.medical_specialty ,Canada ,Time Factors ,Radiofrequency ablation ,Early Recurrence ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,Cryosurgery ,Pulmonary vein ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,Postoperative Complications ,law ,Heart Conduction System ,Recurrence ,Physiology (medical) ,Internal medicine ,Atrial Fibrillation ,Prevalence ,Medicine ,Humans ,030212 general & internal medicine ,Implantable cardiac monitor ,Heart Atria ,Prospective Studies ,business.industry ,Incidence (epidemiology) ,Incidence ,Atrial fibrillation ,Middle Aged ,Ablation ,medicine.disease ,Prognosis ,Radiofrequency catheter ablation ,Pulmonary Veins ,Cardiology ,Catheter Ablation ,Female ,Cardiology and Cardiovascular Medicine ,business ,Follow-Up Studies - Abstract
Early recurrence of atrial tachyarrhythmia (ERAT) is common after pulmonary vein isolation (PVI) and has been associated with an increased risk of late atrial fibrillation (AF) recurrence.The purpose of this study was to determine the incidence and outcomes of patients experiencing ERAT after PVI using advanced-generation ablation technologies.This is a prespecified substudy of the CIRCA-DOSE (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double-Short vs Standard Exposure Duration) trial, a prospective, randomized, multicenter study comparing PVI with contact force-guided radiofrequency ablation to secondary-generation cryoballoon ablation for paroxysmal AF. All study patients received an implantable cardiac monitor to allow continuous rhythm monitoring. ERAT was defined as any recurrent atrial tachyarrhythmia within the first 90 days after AF ablation.ERAT occurred in 61% of the 346 patients at a median of 12 days (range 1-90 days) after ablation. ERAF was a significant predictor of late recurrence (60.1% with ER vs 25.9% without ER; P.001) and symptomatic atrial tachyarrhythmia (31.6% with ERAF vs 6.7% without ERAF; P.001). Receiver operating curve analyses revealed a strong correlation between ERAT timing and burden and late recurrence. Multivariate analysis identified ER timing (hazard ratio [HR] 2.90; 95% confidence interval [CI] 1.41-5.95; P = .004) and burden (HR 1.05 per 1% ER burden; 95% CI 1.04-1.07; P.001) as strong independent predictors of late recurrence. Incidence rate, timing, burden, and prognostic significance of ER did not differ between the study groups.ERAT remains common after PVI despite use of advanced-generation ablation technologies. Early AF recurrence beyond 3 weeks after ablation is associated with increased risk of late recurrence.
- Published
- 2021
5. Autonomic Alterations After Pulmonary Vein Isolation in the CIRCA‐DOSE (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation) Study
- Author
-
Robert S. Sheldon, Roger Tam, Laurent Macle, Marc W. Deyell, Circa-Dose Study Investigators, Atul Verma, Paul Khairy, Jason G. Andrade, Nathaniel M. Hawkins, Kendall Ho, and Lisa Tang
- Subjects
Autonomic function ,Adult ,Male ,medicine.medical_specialty ,Isolation (health care) ,Paroxysmal atrial fibrillation ,medicine.medical_treatment ,Catheter ablation ,030204 cardiovascular system & hematology ,Autonomic Nervous System ,Cryosurgery ,Pulmonary vein ,03 medical and health sciences ,Electrocardiography ,0302 clinical medicine ,Heart Rate ,Recurrence ,Internal medicine ,Atrial Fibrillation ,Medicine ,Humans ,Arrhythmia and Electrophysiology ,Single-Blind Method ,030212 general & internal medicine ,Prospective Studies ,Therapeutic Irrigation ,Original Research ,Aged ,Aged, 80 and over ,business.industry ,autonomic ,Atrial fibrillation ,Middle Aged ,medicine.disease ,Electrophysiology ,Autonomic nervous system ,Treatment Outcome ,Radiofrequency catheter ablation ,Pulmonary Veins ,Cardiology ,Catheter Ablation ,Female ,autonomic function ,Cardiology and Cardiovascular Medicine ,business ,atrial fibrillation arrhythmia ,Catheter Ablation and Implantable Cardioverter-Defibrillator ,Follow-Up Studies - Abstract
Background The natural history of autonomic alterations following catheter ablation of drug‐refractory paroxysmal atrial fibrillation is poorly defined, largely because of the historical reliance on non‐invasive intermittent rhythm monitoring for outcome ascertainment. Methods and Results The study included 346 patients with drug‐refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using contemporary advanced‐generation ablation technologies. All patients underwent insertion of a Reveal LINQ (Medtronic) implantable cardiac monitor before ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (measured as the SD of the average normal‐to‐normal), daytime heart rate, and nighttime heart rate. Longitudinal autonomic data in the 2‐month period leading up to the date of ablation were compared with the period from 91 to 365 days following ablation. Following ablation there was a significant decrease in SD of the average normal‐to‐normal (mean difference versus baseline of 19.3 ms; range, 12.9–25.7; P P P P =0.001) and nighttime heart rates (8±9 versus 6±8 bpm, P =0.049), but no difference in SD of the average normal‐to‐normal ( P =0.09) compared with those with atrial fibrillation recurrence. Ablation technology and cryoablation duration did not influence these autonomic nervous system effects. Conclusions Pulmonary vein isolation results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are correlated with procedural outcome and are independent of the ablation technology used. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01913522.
- Published
- 2021
6. Quality of Life and Health Care Utilization in the CIRCA-DOSE Study
- Author
-
Atul Verma, Paul Khairy, Laurent Macle, Anthony Tang, Circa-Dose Study Investigators, Peter Leong-Sit, Clarence Khoo, Jacques Rizkallah, Paul Novak, Jason G. Andrade, Jean-Francois Roux, Jean Champagne, Marc Dubuc, Sylvie Levesque, John L. Sapp, and Marc W. Deyell
- Subjects
medicine.medical_specialty ,Radiofrequency ablation ,medicine.medical_treatment ,Catheter ablation ,030204 cardiovascular system & hematology ,Cardioversion ,Cryosurgery ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,Quality of life ,Interquartile range ,law ,Atrial Fibrillation ,medicine ,Humans ,030212 general & internal medicine ,business.industry ,Atrial fibrillation ,Patient Acceptance of Health Care ,medicine.disease ,Ablation ,Treatment Outcome ,Pulmonary Veins ,Emergency medicine ,Quality of Life ,Cardioversions ,business - Abstract
This study evaluated the impact of contact force-guided radiofrequency ablation versus cryoballoon ablation on quality of life and health care utilization.Traditional outcome parameters, such as arrhythmia-free survival, are insufficient to evaluate the clinical impact of atrial fibrillation (AF), as it fails to the capture patient- and health system-level differences in treatment approaches.The CIRCA-DOSE (Cryoballoon Vs. Contact-Force Atrial Fibrillation Ablation) study randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency or cryoballoon ablation. Health-related quality-of-life (HRQOL) was assessed at baseline, and at 6 and 12 months post-ablation using a disease-specific and generic HRQOL instruments. Health care utilization (hospitalization, emergency department visits, and cardioversion) and antiarrhythmic drug use for the 12 months preceding ablation was compared with the 12 months following ablation.Disease-specific and generic HRQOL was moderately to severely impaired at baseline and improved significantly at 6 and 12 months of follow-up (median improvement in AFEQT [Atrial Fibrillation Effect on QualiTy of Life] score 32.4 [interquartile range: 17.7 to 48.9]). When compared with the 12 months pre-ablation, the proportion and absolute number of cardioversions decreased significantly (41.1% vs. 10.1% of patients, 137 vs. 35 events; p 0.0001). Similar significant reductions in emergency department visits (66.7% vs. 25.1% of patients, 224 vs. 87 events; p 0.0001), and hospitalizations (25.5% vs. 14.5% of patients, 86 vs. 50 events; p 0.001) were observed. There were no significant differences between randomized groups.In this multicenter randomized trial, catheter ablation with advanced-generation technologies resulted in a significant improvement in HRQOL and a significant reduction in health care utilization in the year following AF ablation. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE]; NCT01913522).
- Published
- 2020
7. Prevalence and outcome of early recurrence of atrial tachyarrhythmias in the Cryoballoon vs Irrigated Radiofrequency Catheter Ablation (CIRCA-DOSE) study.
- Author
-
Steinberg, Christian, Champagne, Jean, Deyell, Marc W., Dubuc, Marc, Leong-Sit, Peter, Calkins, Hugh, Sterns, Lawrence, Badra-Verdu, Mariano, Sapp, John, Macle, Laurent, Khairy, Paul, Andrade, Jason G., and CIRCA-DOSE Study Investigators
- Abstract
Background: Early recurrence of atrial tachyarrhythmia (ERAT) is common after pulmonary vein isolation (PVI) and has been associated with an increased risk of late atrial fibrillation (AF) recurrence.Objective: The purpose of this study was to determine the incidence and outcomes of patients experiencing ERAT after PVI using advanced-generation ablation technologies.Methods: This is a prespecified substudy of the CIRCA-DOSE (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double-Short vs Standard Exposure Duration) trial, a prospective, randomized, multicenter study comparing PVI with contact force-guided radiofrequency ablation to secondary-generation cryoballoon ablation for paroxysmal AF. All study patients received an implantable cardiac monitor to allow continuous rhythm monitoring. ERAT was defined as any recurrent atrial tachyarrhythmia within the first 90 days after AF ablation.Results: ERAT occurred in 61% of the 346 patients at a median of 12 days (range 1-90 days) after ablation. ERAF was a significant predictor of late recurrence (60.1% with ER vs 25.9% without ER; P <.001) and symptomatic atrial tachyarrhythmia (31.6% with ERAF vs 6.7% without ERAF; P <.001). Receiver operating curve analyses revealed a strong correlation between ERAT timing and burden and late recurrence. Multivariate analysis identified ER timing (hazard ratio [HR] 2.90; 95% confidence interval [CI] 1.41-5.95; P = .004) and burden (HR 1.05 per 1% ER burden; 95% CI 1.04-1.07; P <.001) as strong independent predictors of late recurrence. Incidence rate, timing, burden, and prognostic significance of ER did not differ between the study groups.Conclusion: ERAT remains common after PVI despite use of advanced-generation ablation technologies. Early AF recurrence beyond 3 weeks after ablation is associated with increased risk of late recurrence. [ABSTRACT FROM AUTHOR]- Published
- 2021
- Full Text
- View/download PDF
8. Autonomic Alterations After Pulmonary Vein Isolation in the CIRCA-DOSE (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation) Study.
- Author
-
Tang, Lisa Y. W., Hawkins, Nathaniel M., Ho, Kendall, Tam, Roger, Deyell, Marc W., Macle, Laurent, Verma, Atul, Khairy, Paul, Sheldon, Robert, Andrade, Jason G., and CIRCA‐DOSE Study Investigators
- Published
- 2021
- Full Text
- View/download PDF
9. Prevalence and clinical impact of spontaneous and adenosine-induced pulmonary vein reconduction in the Contact-Force vs. Cryoballoon Atrial Fibrillation Ablation (CIRCA-DOSE) study.
- Author
-
Andrade, Jason G., Deyell, Marc W., Nattel, Stanley, Khairy, Paul, Dubuc, Marc, Champagne, Jean, Leong-Sit, Peter, Jolly, Umjeet, Badra-Verdu, Mariano, Sapp, John, Verma, Atul, Macle, Laurent, and CIRCA-DOSE Study Investigators
- Abstract
Background: Use of intraprocedural observation and pharmacologic challenges have been proposed as means to differentiate permanent pulmonary vein (PV)-left atrial conduction block from inadequate ablation lesions.Objective: The purpose of this study was to determine the prevalence and clinical impact of spontaneous and adenosine-provoked reconnection using contemporary atrial fibrillation (AF) ablation technologies.Methods: The CIRCA-DOSE (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration) study enrolled 346 patients with paroxysmal AF and randomized them to contact force-guided radiofrequency ablation (CF-RF) or cryoballoon ablation. Patients underwent provocative testing with adenosine after a 20-minute observation period. All patients received an implantable cardiac monitor for arrhythmia monitoring.Results: Spontaneous reconnection was observed in 5.4% of PVs (71/1318) during the 20-minute postprocedure observation period, and dormant conduction was elicited in 5.7% of PVs (75/1318). Both spontaneous reconnection and dormant conduction were more common after CF-RF compared to cryoballoon ablation (P = .03 and P <.0001, respectively). Acute PV reconnection (spontaneous or adenosine-provoked) was associated with a significantly higher incidence of recurrent atrial tachyarrhythmia in the cryoballoon group (hazard ratio [HR] 2.39; 95% confidence interval [CI] 1.44-3.96; P = .0007) but not in the CF-RF group (HR 1.47; 95% CI 0.84-2.58; P = .16). In the absence of acute reconnection, the freedom from recurrent arrhythmia did not differ between groups (HR 0.95; 95% CI 0.6057-1.495; P = .83).Conclusion: Patients without spontaneous or adenosine-provoked reconnection had better outcomes compared to those with acute PV reconnection, suggesting that efforts should be directed toward ensuring an ideal ablation lesion at the first attempt in order to achieve durable PV isolation. [ABSTRACT FROM AUTHOR]- Published
- 2020
- Full Text
- View/download PDF
10. Clinical assessment of AF pattern is poorly correlated with AF burden and post ablation outcomes: A CIRCA-DOSE sub-study.
- Author
-
Andrade, Jason G., Yao, Robert R.J., Deyell, Marc W., Hawkins, Nathaniel M., Rizkallah, Jacques, Jolly, Umjeet, Khoo, Clarence, Raymond, Jean-Marc, McKinney, James, Cheung, Christopher, Steinberg, Christian, Ha, Andrew, Ramanathan, Krishnan, Luong, Christina, Glover, Benedict, Verma, Atul, Macle, Laurent, Khairy, Paul, and CIRCA-DOSE Study Investigators
- Abstract
Background: Contemporary guidelines recommend that atrial fibrillation (AF) be classified into paroxysmal and persistent AF based on clinical assessment, with these categorizations forming the basis of therapeutic recommendations. While pragmatic, clinical assessment may introduce misclassification errors, which may impact treatment decisions. We sought to determine the relationship between AF classification, baseline AF burden, and post-ablation arrhythmia outcomes.Design: The current study is a sub-analysis of a prospective, parallel-group, multicenter, single-blinded randomized clinical trial. All 346 patients enrolled in CIRCA-DOSE received an implantable cardiac monitor a median of 72 days prior to ablation. AF was classified as low burden paroxysmal, high burden paroxysmal, or persistent based on clinical assessment prior to device implantation. Prior to ablation patients were re-classified using the same definitions based on device monitoring data. Correlation between classifications, AF burden, and post-ablation arrhythmia outcomes were assessed.Results: There was poor agreement between clinical and device-based AF classification (Cohen's kappa: 0.192). AF classification derived from pre-ablation continuous monitoring reflected baseline and post-ablation AF burden with greater accuracy and with less overlap between the AF classes (P < 0.01 for all categorical comparisons). Patients objectively classified as "Low Burden" paroxysmal by continuous monitoring data had significantly greater freedom from recurrent AF/AT/AFL compared to those classified as "High Burden" paroxysmal (hazard ratio [HR] 0.57 for AF/AT/AFL recurrence) or persistent AF (HR 0.19 for AF/AT/AFL recurrence).Conclusions: Classification of AF pattern based on pre-ablation continuous cardiac rhythm monitoring better predicted AF burden and freedom from recurrent AF post ablation. Despite the use of standardized definitions, classification of AF based on clinical assessment did not predict baseline AF burden, post ablation AF burden, or freedom from recurrent AF post ablation.Trial Registration: ClinicalTrials.govNCT01913522. [ABSTRACT FROM AUTHOR]- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.