1. Preventing atrial fibrillation by combined right isthmus ablation and cryoballoon pulmonary vein isolation in patients with typical atrial flutter: PAF-CRIOBLAF study.
- Author
-
Anselme F, Savouré A, Clémenty N, Cesari O, Pavin D, Jesel L, Defaye P, Boveda S, Rivat P, Mansourati J, Mechulan A, Cebron JP, Lande G, Bubenheim ScD M, and Milhem A
- Abstract
Background: Although less common, typical atrial flutter shares similar pathophysiological roots with atrial fibrillation. Following successful cavo-tricuspid isthmus ablation using radiofrequency, many patients, however, develop atrial fibrillation in the mid-to-long-term. This study sought to assess whether pulmonary vein isolation conducted at the same time as cavo-tricuspid isthmus ablation would significantly modify the atrial fibrillation burden upon follow-up in patients suffering from typical atrial flutter., Methods: This was a multicenter randomized controlled study involving typical atrial flutter patients with history of non-predominant atrial fibrillation (1 atrial fibrillation episode only, in 67% of population) who were scheduled for cavo-tricuspid isthmus radiofrequency ablation. Patients were randomly assigned to either undergo cavo-tricuspid isthmus ablation alone or cavo-tricuspid isthmus plus pulmonary vein isolation (CTI+). Pulmonary vein isolation was performed using cryoballoon technology. An outpatient consultation with ECG and 1-week Holter monitoring was performed at 3, 6 months, 1 year, and 2 years postprocedure. The primary endpoint was atrial fibrillation recurrences lasting more than 30 s at 2 years postablation., Results: Of the patients enrolled, 36 were included in each group. At 2-year follow-up, the atrial fibrillation recurrence rate was significantly higher in the CTI vs CTI+group (25/36, 69% vs. 12/36, 33% respectively; P < .001), with similar typical atrial flutter recurrence rates. There were no differences in undesirable events, except for transient phrenic nerve palsy reported from three CTI+patients (8.3%)., Conclusion: Pulmonary vein isolation using cryoballoon technology was proven to significantly reduce the atrial fibrillation incidence at 2 years postcavo-tricuspid isthmus ablation., Competing Interests: FA is consultant for and received lecture fees from Boston Scientific, Medtronic, and Microport CRM. AS received honoraria from Microport CRM. NC is consultant for and received lecture fees from Medtronic. PD received research grants and honoraria from Boston Scientific, Abbott, Microport CRM, and Medtronic. SB is consultant for Medtronic, Boston Scientific, Microport CRM, and Zoll. The other authors declare no conflicts of interest. The protocol for this research has been approved by a suitable constituted Ethics Committee of the institution under the approval number 2011‐A00806‐35, on July 21, 2011 and it conforms to the provisions of the Declaration of Helsinki. The ClinicalTrial identifier of this study is NCT01521988, (© 2021 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society.)
- Published
- 2021
- Full Text
- View/download PDF