9 results on '"Camarero TG"'
Search Results
2. Effects of the COVID-19 Pandemic on a Population Older Than 75 Years With Previous Percutaneous Coronary Revascularization: Subanalysis of the SIERRA 75 Registry
- Author
-
Hernandez, JD, Carrillo, P, Jimenez-Mazuecos, J, Esteves, AF, Cordoba-Soriano, JG, Gutierrez-Barrios, A, Alvarez, BC, Perez, GC, Camarero, TG, Trillo, R, de Prado, AP, Dominguez, JFO, Ferre, GF, Diaz, VAJ, Lozano, I, San Roman, KG, Ocaranza-Sanchez, R, Caceres, GM, Fores, JS, Leal, S, Carrillo, X, Rodrigues, A, Sadaba, M, Otaegui, I, Fernandez, EL, Vicente, JAL, Morales, FJ, Santos, R, and Ojeda, FB
- Published
- 2020
3. Prospective application of a bleeding and ischemic risks-adjusted antithrombotic protocol in elderly patients revascularized with everolimus-eluting stents: EPIC05-Sierra75 study.
- Author
-
de la Torre Hernandez JM, Palop RL, Jimenez Mazuecos JM, Sáez PC, Gutierez-Barrios A, Pinar E, Cid B, Fernandez L, Camarero TG, Urbano-Carrillo C, Oteo Dominguez JF, Jimenez Diaz VA, Gomez Menchero AE, Fernández EG, Córdoba Soriano JG, Ocaranza R, Úcar EA, Roman KGS, Leal S, Cáceres GM, Linares Vicente JA, Ferre GF, Carrillo X, Rama Merchán JC, Costa C, Sanchis J, Fernandes R, Rodrigues A, Vegas Valle JM, Pereira H, and de Prado AP
- Abstract
Objectives: Elderly patients show a higher incidence of ischemic and bleeding events after percutaneous transluminal coronary intervention (PCI). We sought to investigate outcomes in elderly patients treated with antithrombotic strategy guided by bleeding and ischemic risks after revascularization with last generation everolimus-eluting stent (EES)., Methods: Prospective multicenter registry including patients over 75 years revascularized with EES and antithrombotic therapy guided by clinical presentation, PCI complexity and PRECISE DAPT score. Co-primary safety endpoints were: (1) composite of cardiac death, myocardial infarction and stent thrombosis and; (2) bleeding (BARC 2-5). Primary efficacy endpoint was target lesion revascularization. A matched group of patients revascularized with current drug-eluting stents and no such tailored antithrombotic therapy was used as control., Results: Finally, 1064 patients were included in SIERRA-75 cohort, 80.8 ± 4.2 years, 36.6% women, 71% acute coronary syndromes (ACS) and 53.6% complex PCI. Co-primary safety endpoint of major adverse cardiovascular events was met in 6.2%, co-primary safety endpoint of bleeding in 7.8% and primary efficacy endpoint of TKLR in 1.5%. The multivariable adjusted model showed no significant association of the prescribed short/long dual antiplatelet therapy (DAPT) durations with any endpoint suggesting a well tailored therapy. No stent thrombosis reported in the subgroup with 1-3 months DAPT duration. As compared to control group, bleeding BARC 2-5 was significantly lower in SIERRA-75 group (7.4% vs . 10.2%, P = 0.04) as well as the net safety-efficacy endpoint (14.3% vs . 18.5%, P = 0.02)., Conclusions: In elderly population, the application of this risks-adjusted antithrombotic protocol after revascularization with last generation EES seems to be associated with an improved prognosis in terms of ischemic and bleeding outcomes., (Copyright and License information: Journal of Geriatric Cardiology 2022.)
- Published
- 2022
- Full Text
- View/download PDF
4. Optical coherence tomography, intravascular ultrasound or angiography guidance for distal left main coronary stenting. The ROCK cohort II study.
- Author
-
Cortese B, de la Torre Hernandez JM, Lanocha M, Ielasi A, Giannini F, Campo G, D'Ascenzo F, Latini RA, Krestianinov O, Alfonso F, Trani C, Prati F, Linares JA, Sardella G, Wlodarczak A, Viganò E, Camarero TG, Stella P, Sozykin A, Fineschi M, and Burzotta F
- Subjects
- Coronary Angiography methods, Coronary Vessels diagnostic imaging, Coronary Vessels pathology, Humans, Retrospective Studies, Tomography, Optical Coherence methods, Treatment Outcome, Ultrasonography, Interventional methods, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease therapy, Percutaneous Coronary Intervention adverse effects, Percutaneous Coronary Intervention methods
- Abstract
Objectives: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly., Background: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited., Methods: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS., Results: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found., Conclusions: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS., (© 2021 Wiley Periodicals LLC.)
- Published
- 2022
- Full Text
- View/download PDF
5. Antithrombotic Treatment After Coronary Intervention: Agreement and Controversy.
- Author
-
Camarero TG and de la Torre Hernández JM
- Abstract
Percutaneous revascularisation has evolved dramatically in the past few decades. The approach to the management of ischaemic heart disease has changed due to the development of new devices and techniques as well as the availability of new drugs and treatment strategies. Its use in combination with antiplatelet therapies has been essential to protect against stent thrombosis. The length of time this combination therapy is used has been modified in recent years and has been the subject of extensive research. The effect of prolonging the time it is taken or shortening it has been evaluated in different clinical conditions. In practice, the decisions regarding antithrombotic therapy after percutaneous coronary intervention are informed by the patient's profile and the characteristics of the procedures performed. In this article, we review the use of antiplatelet/anticoagulant therapy after percutaneous coronary intervention focusing on trials and guidelines addressing variable durations for combination regimens and the alternatives., Competing Interests: Disclosure: The authors received unrestricted grants for research from Boston Scientific, Abbott Vascular, St Jude Medical, Biotronik and Biosensors. They have also received consulting fees from Medtronic, Astra-Zeneca, Biotronik, Boston Scientific and Abbott Vascular., (Copyright © 2020, Radcliffe Cardiology.)
- Published
- 2020
- Full Text
- View/download PDF
6. Polymeric endovascular strut and lumen detection algorithm for intracoronary optical coherence tomography images.
- Author
-
Amrute JM, Athanasiou LS, Rikhtegar F, de la Torre Hernández JM, Camarero TG, and Edelman ER
- Subjects
- Algorithms, Humans, Polymers chemistry, Prosthesis Design, Tomography, Optical Coherence instrumentation, Coronary Vessels diagnostic imaging, Endovascular Procedures instrumentation, Tomography, Optical Coherence methods
- Abstract
Polymeric endovascular implants are the next step in minimally invasive vascular interventions. As an alternative to traditional metallic drug-eluting stents, these often-erodible scaffolds present opportunities and challenges for patients and clinicians. Theoretically, as they resorb and are absorbed over time, they obviate the long-term complications of permanent implants, but in the short-term visualization and therefore positioning is problematic. Polymeric scaffolds can only be fully imaged using optical coherence tomography (OCT) imaging-they are relatively invisible via angiography-and segmentation of polymeric struts in OCT images is performed manually, a laborious and intractable procedure for large datasets. Traditional lumen detection methods using implant struts as boundary limits fail in images with polymeric implants. Therefore, it is necessary to develop an automated method to detect polymeric struts and luminal borders in OCT images; we present such a fully automated algorithm. Accuracy was validated using expert annotations on 1140 OCT images with a positive predictive value of 0.93 for strut detection and an R2 correlation coefficient of 0.94 between detected and expert-annotated lumen areas. The proposed algorithm allows for rapid, accurate, and automated detection of polymeric struts and the luminal border in OCT images., ((2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).)
- Published
- 2018
- Full Text
- View/download PDF
7. Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images.
- Author
-
Amrute JM, Athanasiou L, Rikhtegar F, de la Torre Hernández JM, Camarero TG, and Edelman ER
- Abstract
Bioresorbable vascular scaffolds (BVS), the next step in the continuum of minimally invasive vascular interventions present new opportunities for patients and clinicians but challenges as well. As they are comprised of polymeric materials standard imaging is challenging. This is especially problematic as modalities like optical coherence tomography (OCT) become more prevalent in cardiology. OCT, a light-based intracoronary imaging technique, provides cross-sectional images of plaque and luminal morphology. Until recently segmentation of OCT images for BVS struts was performed manually by experts. However, this process is time consuming and not tractable for large amounts of patient data. Several automated methods exist to segment metallic stents, which do not apply to the newer BVS. Given this current limitation coupled with the emerging popularity of the BVS technology, it is crucial to develop an automated methodology to segment BVS struts in OCT images. The objective of this paper is to develop a novel BVS strut detection method in intracoronary OCT images. First, we preprocess the image to remove imaging artifacts. Then, we use a K-means clustering algorithm to automatically segment the image. Finally, we isolate the stent struts from the rest of the image. The accuracy of the proposed method was evaluated using expert estimations on 658 annotated images acquired from 7 patients at the time of coronary arterial interventions. Our proposed methodology has a positive predictive value of 0.93, a Pearson Correlation coefficient of 0.94, and a F1 score of 0.92. The proposed methodology allows for rapid, accurate, and fully automated segmentation of BVS struts in OCT images.
- Published
- 2017
- Full Text
- View/download PDF
8. Early healing assessment with optical coherence tomography of everolimus-eluting stents with bioabsorbable polymer (synergy™) at 3 and 6 months after implantation.
- Author
-
de la Torre Hernández JM, Tejedor P, Camarero TG, Duran JM, Lee DH, Monedero J, Laso FS, Calderón MA, Veiga G, and Zueco J
- Subjects
- Aged, Cardiovascular Agents adverse effects, Coronary Angiography, Coronary Artery Disease diagnostic imaging, Coronary Vessels diagnostic imaging, Everolimus adverse effects, Female, Humans, Male, Middle Aged, Neointima, Percutaneous Coronary Intervention adverse effects, Platelet Aggregation Inhibitors administration & dosage, Predictive Value of Tests, Prospective Studies, Prosthesis Design, Spain, Time Factors, Treatment Outcome, Absorbable Implants, Cardiovascular Agents administration & dosage, Coronary Artery Disease therapy, Coronary Vessels drug effects, Drug-Eluting Stents, Everolimus administration & dosage, Percutaneous Coronary Intervention instrumentation, Polymers chemistry, Tomography, Optical Coherence, Wound Healing drug effects
- Abstract
Objectives: In this study we sought to evaluate coverage and apposition of Synergy™ stent at 3 and 6 months after implantation., Background: The Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy™) is a new generation drug-eluting stent with features potentially favoring an early healing process which could make safe a shorter period of dual antiplatelet-therapy treatment., Methods: Prospective, two-centers study enrolling patients with similar lesions treated with Synergy™ stents undergoing examination with OCT at 3 and 6 months in the respective centers. Blinded analysis was done at a core lab. Co-primary endpoints were proportion of struts with coverage and with apposition at 3 and 6 months., Results: Finally, 22 patients (30 stents) in the 3 months group and 20 patients (30 stents) in the 6 months group were included. There were no significant differences between groups regarding clinical, angiographic measurements, and procedural data. The rate of strut coverage was 94.5% at 3 months and 96.6% at 6 months (P < 0.001), the rates of apposition were 93.8% and 96.2%, respectively, (P < 0.001), the proportion of uncovered but apposed struts was 2.5% and 1.9% (P = 0.03) and the proportion of uncovered and malapposed struts was 3% and 1.8%, respectively (P < 0.001). The maximal area of malapposition related with uncovered struts was 0.43 ± 0.4 mm(2) at 3 months and 0.14 ± 0.2 mm(2) at 6 months (P = 0.001)., Conclusions: The everolimus-eluting stent with absorbable polymer, Synergy™, is associated to a high degree of intimal coverage and apposition at 3 months after implantation with additional increase at 6 months. © 2015 Wiley Periodicals, Inc., (© 2015 Wiley Periodicals, Inc.)
- Published
- 2016
- Full Text
- View/download PDF
9. Role of cardiovascular risk factors in patients with chest pain, a non-diagnostic first ECG and negative biomarkers.
- Author
-
Valle HA, Camarero TG, Piqueres CS, and García-Castrillo L
- Subjects
- Acute Coronary Syndrome diagnosis, Biomarkers, Causality, Comorbidity, Diagnosis, Differential, Electrocardiography, Emergency Service, Hospital statistics & numerical data, Humans, Risk Factors, Spain epidemiology, Acute Coronary Syndrome epidemiology, Chest Pain diagnosis, Chest Pain epidemiology
- Published
- 2009
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.