1. Raman Spectroscopy of Blood Serum for Essential Thrombocythemia Diagnosis: Correlation with Genetic Mutations and Optimization of Laser Wavelengths.
- Author
-
Aday A, Bayrak AG, Toraman S, Hindilerden İY, Nalçacı M, Depciuch J, Cebulski J, and Guleken Z
- Subjects
- Humans, Female, Male, Middle Aged, Adult, Aged, Lasers, Support Vector Machine, Isocitrate Dehydrogenase genetics, Machine Learning, Calreticulin genetics, Calreticulin blood, Case-Control Studies, Receptors, Thrombopoietin genetics, Repressor Proteins, Spectrum Analysis, Raman methods, Janus Kinase 2 genetics, Thrombocythemia, Essential blood, Thrombocythemia, Essential genetics, Thrombocythemia, Essential diagnosis, Mutation, Principal Component Analysis
- Abstract
Essential thrombocythemia (ET) is a type of myeloproliferative neoplasm that increases the risk of thrombosis. To diagnose this disease, the analysis of mutations in the Janus Kinase 2 (JAK2), thrombopoietin receptor (MPL), or calreticulin (CALR) gene is recommended. Disease poses diagnostic challenges due to overlapping mutations with other neoplasms and the presence of triple-negative cases. This study explores the potential of Raman spectroscopy combined with machine learning for ET diagnosis. We assessed two laser wavelengths (785, 1064 nm) to differentiate between ET patients and healthy controls. The PCR results indicate that approximately 50% of patients in our group have a mutation in the JAK2 gene, while only 5% of patients harbor a mutation in the ASXL1 gene. Additionally, only one patient had a mutation in the IDH1 and one had a mutation in IDH2 gene. Consequently, patients having no mutations were also observed in our group, making diagnosis challenging. Raman spectra at 1064 nm showed lower amide, polysaccharide, and lipid vibrations in ET patients, while 785 nm spectra indicated significant decreases in amide II and C-H lipid vibrations. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800-1800 cm
-1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800-1800 cm-1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum., (© 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)- Published
- 2024
- Full Text
- View/download PDF