6 results on '"Breton HL"'
Search Results
2. Mitral Valve Infective Endocarditis after Trans-Catheter Aortic Valve Implantation.
- Author
-
Panagides V, Del Val D, Abdel-Wahab M, Mangner N, Durand E, Ihlemann N, Urena M, Pellegrini C, Giannini F, Scislo P, Huczek Z, Landt M, Auffret V, Sinning JM, Cheema AN, Nombela-Franco L, Chamandi C, Campelo-Parada F, Munoz-Garcia E, Herrmann HC, Testa L, Kim WK, Castillo JC, Alperi A, Tchetche D, Bartorelli AL, Kapadia S, Stortecky S, Amat-Santos I, Wijeysundera HC, Lisko J, Gutiérrez-Ibanes E, Serra V, Salido L, Alkhodair A, Livi U, Chakravarty T, Lerakis S, Vilalta V, Regueiro A, Romaguera R, Kappert U, Barbanti M, Masson JB, Maes F, Fiorina C, Miceli A, Kodali S, Ribeiro HB, Mangione JA, Brito FS Jr, Dato GMA, Rosato F, Ferreira MC, de Lima VC, Colafranceschi AS, Abizaid A, Marino MA, Esteves V, Andrea J, Godinho RR, Alfonso F, Eltchaninoff H, Søndergaard L, Himbert D, Husser O, Latib A, Breton HL, Servoz C, Pascual I, Siddiqui S, Olivares P, Hernandez-Antolin R, Webb JG, Sponga S, Makkar R, Kini AS, Boukhris M, Gervais P, Linke A, Crusius L, Holzhey D, and Rodés-Cabau J
- Subjects
- Aortic Valve surgery, Catheters adverse effects, Humans, Mitral Valve surgery, Risk Factors, Treatment Outcome, Aortic Valve Insufficiency complications, Aortic Valve Insufficiency epidemiology, Aortic Valve Insufficiency surgery, Aortic Valve Stenosis complications, Aortic Valve Stenosis surgery, Endocarditis epidemiology, Endocarditis etiology, Heart Valve Prosthesis adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Scarce data exist on mitral valve (MV) infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This multicenter study included a total of 579 patients with a diagnosis of definite IE after TAVI from the IE after TAVI International Registry and aimed to evaluate the incidence, characteristics, management, and outcomes of MV-IE after TAVI. A total of 86 patients (14.9%) had MV-IE. These patients were compared with 284 patients (49.1%) with involvement of the transcatheter heart valve (THV) only. Two factors were found to be associated with MV-IE: the use of self-expanding valves (adjusted odds ratio 2.49, 95% confidence interval [CI] 1.23 to 5.07, p = 0.012), and the presence of an aortic regurgitation ≥2 at discharge (adjusted odds ratio 3.33; 95% CI 1.43 to 7.73, p <0.01). There were no differences in IE timing and causative microorganisms between groups, but surgical management was significantly lower in patients with MV-IE (6.0%, vs 21.6% in patients with THV-IE, p = 0.001). All-cause mortality rates at 2-year follow-up were high and similar between patients with MV-IE (51.4%, 95% CI 39.8 to 64.1) and patients with THV-IE (51.5%, 95% CI 45.4 to 58.0) (log-rank p = 0.295). The factors independently associated with increased mortality risk in patients with MV-IE were the occurrence of heart failure (adjusted p <0.001) and septic shock (adjusted p <0.01) during the index hospitalization. One of 6 IE episodes after TAVI is localized on the MV. The implantation of a self-expanding THV and the presence of an aortic regurgitation ≥2 at discharge were associated with MV-IE. Patients with MV-IE were rarely operated on and had a poor prognosis at 2-year follow-up., (Copyright © 2022 Elsevier Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
3. Pharmacoinvasive Strategy Versus Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction in Patients ≥70 Years of Age.
- Author
-
Auffret V, Laurin C, Leurent G, Didier R, Filippi E, Hacot JP, Zabalawi A, Rouault G, Saouli D, Druelles P, Coudert I, Boulanger B, Bot E, Treuil J, Bedossa M, Boulmier D, Loirat A, Sharobeem S, Guellec ML, Gilard M, and Breton HL
- Subjects
- Aged, Aged, 80 and over, Cause of Death trends, Female, Follow-Up Studies, France epidemiology, Hospital Mortality trends, Humans, Male, Percutaneous Coronary Intervention methods, Prognosis, Prospective Studies, Risk Factors, ST Elevation Myocardial Infarction mortality, Survival Rate trends, Thrombolytic Therapy methods, Time-to-Treatment, Percutaneous Coronary Intervention standards, Practice Guidelines as Topic, Registries, ST Elevation Myocardial Infarction therapy, Thrombolytic Therapy standards
- Abstract
The benefit-risk ratio of a pharmacoinvasive strategy (PI) in patients ≥70 years of age with ST-segment elevation myocardial infarction (STEMI) remains uncertain resulting in its limited use in this population. This study compared efficacy and safety of PI with primary percutaneous coronary intervention (pPCI). Data from 2,841 patients (mean age: 78.1 ± 5.6 years, female: 36.1%) included in a prospective multicenter registry, and who underwent either PI (n = 269) or pPCI (n = 2,572), were analyzed. The primary end point was in-hospital major adverse cardiovascular events (MACE) defined as the composite of all-cause mortality, nonfatal MI, stroke, and definite stent thrombosis. Secondary end points included all-cause death, major bleeding, net adverse clinical events, and the development of in-hospital Killip class III or IV heart failure. Propensity-score matching and conditional logistic regression were used to adjust for confounders. Within the matched cohort, rates of MACE was not statistically different between the PI (n = 247) and pPCI (n = 958) groups, (11.3% vs 9.0%, respectively, odds ratio 1.25, 95% confidence interval 0.81 to 1.94; p = 0.31). Secondary end points were comparable between groups at the exception of a lower rate of development of Killip class III or IV heart failure after PI. The rate of intracranial hemorrhage was significantly higher in the PI group (2.3% vs 0.0%, p = 0.03). In conclusion, the present study demonstrated no difference regarding in-hospital MACE following PI or pPCI in STEMI patients ≥70 years of age. An adequately-powered randomized trial is needed to precisely define the role of PI in this high-risk subgroup., (Copyright © 2019 Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
4. Markov random field modeling for three-dimensional reconstruction of the left ventricle in cardiac angiography.
- Author
-
Medina R, Garreau M, Toro J, Breton HL, Coatrieux JL, and Jugo D
- Subjects
- Humans, Information Storage and Retrieval methods, Markov Chains, Models, Cardiovascular, Models, Statistical, Phantoms, Imaging, Reproducibility of Results, Sensitivity and Specificity, Algorithms, Angiography methods, Heart Ventricles diagnostic imaging, Image Enhancement methods, Image Interpretation, Computer-Assisted methods, Imaging, Three-Dimensional methods
- Abstract
This paper reports on a method for left ventricle three-dimensional (3-D) reconstruction from two orthogonal ventriculograms. The proposed algorithm is voxel-based and takes into account the conical projection geometry associated with the biplane image acquisition equipment. The reconstruction process starts with an initial ellipsoidal approximation derived from the input ventriculograms. This model is subsequently deformed in such a way as to match the input projections. To this end, the object is modeled as a 3-D Markov-Gibbs random field, and an energy function is defined so that it includes one term that models the projections compatibility and another one that includes the space-time regularity constraints. The performance of this reconstruction method is evaluated by considering the reconstruction of mathematically synthesized phantoms and two 3-D binary databases from two orthogonal synthesized projections. The method is also tested using real biplane ventriculograms. In this case, the performance of the reconstruction is expressed in terms of the projection error, which attains values between 9.50% and 11.78 % for two biplane sequences including a total of 55 images.
- Published
- 2006
- Full Text
- View/download PDF
5. [Loss of a stent in the left main coronary artery and secondary migration into the left circumflex artery needing surgical extraction. Apropos of a case].
- Author
-
Bedossa M, Breton HL, Leclercq C, Valla J, Bories J, Zaki A, Poret P, and Pony JC
- Subjects
- Angioplasty, Balloon, Coronary instrumentation, Coronary Angiography, Coronary Artery Bypass, Female, Foreign-Body Migration surgery, Humans, Middle Aged, Treatment Outcome, Angioplasty, Balloon, Coronary adverse effects, Foreign-Body Migration diagnosis, Stents
- Abstract
The authors report a case of accidental loss of a coronary stent in the coronary arteries and its migration into the circumflex artery. This complication occurred during revascularisation of the left anterior descending artery. In view of a dissection at the site of angioplasty and the migration of the stent, emergency surgery was undertaken comprising bypass grafting of the left anterior descending and arteriology of the left circumflex arteries to recover the stent. This is a rare complication, the frequency is probably underestimated. The authors discuss the factors predisposing to failure of implantation and the means of recovering the stents. The consequences of loss of a stent in the coronary or systemic circulations are also commented.
- Published
- 1996
6. AREVA: multicenter randomized comparison of low-dose versus standard-dose anticoagulation in patients with mechanical prosthetic heart valves.
- Author
-
Acar J, Iung B, Boissel JP, Samama MM, Michel PL, Teppe JP, Pony JC, Breton HL, Thomas D, Isnard R, de Gevigney G, Viguier E, Sfihi A, Hanania G, Ghannem M, Mirode A, and Nemoz C
- Subjects
- Administration, Oral, Adult, Aged, Bleeding Time, Dose-Response Relationship, Drug, Female, Hemorrhage chemically induced, Hemorrhage mortality, Humans, Incidence, Male, Middle Aged, Survival Analysis, Thromboembolism drug therapy, Thromboembolism mortality, Thromboembolism prevention & control, Time Factors, Treatment Outcome, Anticoagulants administration & dosage, Heart Valve Prosthesis
- Abstract
Background: Moderate anticoagulation may be proposed to reduce the risk of hemorrhage for certain patients with a mechanical prosthesis, but the consequences for risk of thromboembolism are debated., Methods and Results: The purpose of the AREVA trial was to compare moderate oral anticoagulation (international normalized ratio [INR] of 2.0 to 3.0) with the usual regimen (INR of 3.0 to 4.5) after a single-valve replacement with a mechanical prosthesis, either Omnicarbon or St Jude. Patients included were between 18 and 75 years old, in sinus rhythm, and with a left atrial diameter < or = 50 mm on the time-motion echocardiogram. Patients were randomized for INR after surgery. From 1991 to 1994, 433 patients underwent valve replacement (aortic, 414; mitral, 19) with 353 St Jude and 80 Omnicarbon prostheses; 380 patients were randomized for INR: 188 for INR 2.0 to 3.0 and 192 for INR 3.0 to 4.5. Mean follow-up was 2.2 years (1 to 4 years). Analysis of 18001 INR samples showed that the mean of the median of INR was 2.74 +/- 0.35 in the 2.0 to 3.0 group and 3.21 +/- 0.33 in the 3.0 to 4.5 group (P < .0001). Thromboembolic events, as assessed from clinical data and CT brain scans, occurred in 10 patients in the 2.0 to 3.0 INR group and 9 patients in the 3.0 to 4.5 INR group (P = .78). Hemorrhagic events occurred in 34 patients in the 2.0 to 3.0 INR group and 56 patients in the 3.0 to 4.5 INR group (P < .01), with 13 and 19 major hemorrhagic events, respectively (P = .29)., Conclusions: In selected patients with mechanical prostheses, moderate anticoagulation prevents thromboembolic events as effectively as conventional anticoagulation and reduces the incidence of hemorrhagic events.
- Published
- 1996
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.