30 results on '"Bioprosthesi"'
Search Results
2. Novel transcatheter mitral prosthesis designed to preserve physiological ventricular flow dynamics
- Author
-
Scorsin, M, Andreas, M, Corona, S, Guta, A, Aruta, P, Badano, L, Scorsin, Marcio, Andreas, Martin, Corona, Silvia, Guta, Andrada Camelia, Aruta, Patrizia, Badano, Luigi, Scorsin, M, Andreas, M, Corona, S, Guta, A, Aruta, P, Badano, L, Scorsin, Marcio, Andreas, Martin, Corona, Silvia, Guta, Andrada Camelia, Aruta, Patrizia, and Badano, Luigi
- Abstract
Background: Current mitral bioprostheses are akin to the aortic valve and therefore abolish the left ventricular (LV) physiological vortex. We evaluated the hemodynamic performance and the effects on intraventricular flow dynamics (IFD) of a novel mitral bioprosthesis that presents an innovative design mimicking the native valve. Methods: A D-shaped self-expandable stent-bovine pericardium monoleaflet valve was designed to provide physiological asymmetric intraventricular flow. Transapical implantation was consecutively performed in 12 juvenile sheep. Postimplant studies using Doppler echocardiography and IFD using echo particle imaging velocimetry were obtained immediately after the implantation and at 3 months to assess the hemodynamic performance of the prostheses. Results: There were 3 deaths during follow-up, 1 due to valve misplacement because of poor imaging visualization and 2 not valve related. The mean transvalvular gradient and effective orifice area were 2.2 ± 1.2 mm Hg and 4.0 ± 1.1 cm2 after implantation and 3.3 ± 1.5 mm Hg and 3.5 ± 0.5 cm2 at 3 months, respectively. LV vortex dimension, orientation, and physiological anticlockwise rotation were preserved compared with preoperative normal LV flow pattern. One animal showed a moderate paravalvular leak, others mild or none. LV outflow tract obstruction, valve thrombosis, and hemolysis were not observed. Conclusions: Our preclinical in vivo results confirm the good hemodynamic performance of this new transcatheter bioprosthesis with preservation of the physiological IFD. Clinical studies are needed to document whether these characteristics will foster LV recovery and improve the clinical outcome of patients with mitral regurgitation.
- Published
- 2022
3. Commentary: Mitral bioprosthesis degeneration: Looking for a benchmark to tailor the correct procedure to the patient
- Author
-
Francesco Nicolini, Francesco Formica, Formica, F, and Nicolini, F
- Subjects
Pulmonary and Respiratory Medicine ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,medicine.medical_specialty ,business.industry ,General surgery ,MEDLINE ,Degeneration (medical) ,Prosthesis Failure ,Benchmarking ,Heart Valve Prosthesi ,Heart Valve Prosthesis ,Benchmark (computing) ,Medicine ,Humans ,Mitral Valve ,Surgery ,Cardiology and Cardiovascular Medicine ,business ,Bioprosthesi ,Human - Published
- 2022
4. Optimal anticoagulation in patients with atrial fibrillation and bioprosthetic heart valves
- Author
-
Roberta Bottino, Andreina Carbone, Biagio Liccardo, Egidio Imbalzano, Antonello D’Andrea, Vincenzo Russo, Bottino, R., Carbone, A., Liccardo, B., Imbalzano, E., D'Andrea, A., and Russo, V.
- Subjects
Bioprosthesis ,bioprosthetic valve ,Aortic Valve ,Heart Valve Prosthesis ,Atrial Fibrillation ,Anticoagulant ,Anticoagulants ,Humans ,antithrombotic therapy ,Cardiology and Cardiovascular Medicine ,anticoagulation ,Bioprosthesi ,Human - Abstract
The antithrombotic management of patients after surgical or transcatheter bioprosthetic heart valves (BHVs) replacement is still challenging. Our review aims to describe the current evidence on the best antithrombotic strategy among patients undergoing BHVs replacement (surgical or transcatheter) and/or valve repair, with particular attention to those with atrial fibrillation.
- Published
- 2022
5. Novel transcatheter mitral prosthesis designed to preserve physiological ventricular flow dynamics
- Author
-
Luigi P. Badano, Martin Andreas, A C Guta, Silvia Corona, Patrizia Aruta, Marcio Scorsin, Scorsin, M, Andreas, M, Corona, S, Guta, A, Aruta, P, and Badano, L
- Subjects
Male ,Pulmonary and Respiratory Medicine ,Aortic valve ,Cardiac Catheterization ,medicine.medical_specialty ,Hemodynamics ,Doppler echocardiography ,Prosthesis Design ,Mitral prosthesis ,Internal medicine ,medicine ,Mitral valve ,Animals ,Humans ,Ventricular Function ,Pericardium ,Paravalvular leak ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,transcatheter implant ,Mitral regurgitation ,Sheep ,medicine.diagnostic_test ,intraventricular flow dynamic ,business.industry ,Infant ,Mitral Valve Insufficiency ,MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE ,Particle imaging velocimetry ,Echocardiography, Doppler ,medicine.anatomical_structure ,Heart Valve Prosthesis ,bioprosthesi ,Cardiology ,Cattle ,Female ,Surgery ,Cardiology and Cardiovascular Medicine ,business ,Blood Flow Velocity - Abstract
Background Current mitral bioprostheses are akin to the aortic valve and therefore abolish the left ventricular (LV) physiological vortex. We evaluated the hemodynamic performance and the effects on intraventricular flow dynamics (IFD) of a novel mitral bioprosthesis that presents an innovative design, mimicking the native valve. Methods A D-shaped self-expandable stent-bovine pericardium monoleaflet valve was designed to provide physiological asymmetric intraventricular flow. Twelve juvenile sheep were consecutively implanted transapically. Post-implant studies were obtained immediately after the implantation and at 3 months to assess the hemodynamic performance of the prostheses, using Doppler echocardiography and IFD using echo particle imaging velocimetry. Results Three deaths occurred during follow-up, one due to valve misplacement because of poor imaging visualization and 2 not valve related. Mean transvalvular gradient and effective orifice area after implantation and at 3 months were 2.2 ± 1.2 mmHg and 4.0 ± 1.1 cm2, and 3.3 ± 1.5 mmHg and 3.5 ± 0.5 cm2, respectively. LV vortex dimension, orientation and physiologic anti-clockwise rotation were preserved compared with pre-operative normal LV flow pattern. One animal showed a moderate paravalvular leak, others mild or none. LV outflow tract obstruction, valve thrombosis or hemolysis were not observed. Conclusions Our preclinical in vivo results, confirm the good hemodynamic performance of this new transcatheter bioprosthesis with preservation of the physiological IFD. Clinical studies are needed to document whether these characteristics will foster LV recovery and improve the clinical outcome of patients with mitral regurgitation.
- Published
- 2022
6. New Oral Anticoagulants Versus Warfarin in Atrial Fibrillation After Early Postoperative Period in Patients With Bioprosthetic Aortic Valve
- Author
-
Pasquale Mastroroberto, Luigi Mannacio, Gabriele Iannelli, Carlo Zebele, Ciro Mauro, Vito Mannacio, Anita Antignano, Francesco Musumeci, Mannacio, V. A., Mannacio, L., Antignano, A., Mauro, C., Mastroroberto, P., Musumeci, F., Zebele, C., and Iannelli, G.
- Subjects
Pulmonary and Respiratory Medicine ,Aortic valve ,Male ,medicine.medical_specialty ,medicine.drug_class ,Administration, Oral ,law.invention ,Randomized controlled trial ,Aortic valve replacement ,law ,Internal medicine ,Atrial Fibrillation ,Medicine ,Humans ,Stroke ,Bioprosthesi ,Aged ,Retrospective Studies ,Bioprosthesis ,Aged, 80 and over ,Heart Valve Prosthesis Implantation ,business.industry ,Hazard ratio ,Warfarin ,Anticoagulant ,Anticoagulants ,Atrial fibrillation ,Vitamin K antagonist ,Middle Aged ,medicine.disease ,medicine.anatomical_structure ,Aortic Valve ,Cardiology ,Surgery ,Female ,Cardiology and Cardiovascular Medicine ,business ,medicine.drug ,Human - Abstract
Background: The efficacy of novel nonvitamin K antagonist oral anticoagulants (NOACs) in nonvalvular atrial fibrillation (AF) to prevent stroke is well assessed, but NOACs use in AF that occurs after bioprosthetic aortic valve replacement (AVR) is not endorsed. This retrospective real-world study evaluated the efficacy and safety of NOACs prescribed no earlier than 4 months after AVR as an alternative to warfarin in patients with AF. Methods: We pooled 1032 patients from the databases of 5 centers. Ischemic/embolic events and major bleeding rates were compared between 340 patients assuming NOACs and 692 prescribed warfarin. Propensity score matching was performed to avoid the bias between groups. Results: The NOACs vs warfarin embolic/ischemic rate was 13.5% (46 of 340) vs 22.7% (157 of 692), respectively, (hazard ratio [HR], 0.5; 95% confidence interval [CI], 0.37-0.75; P < .001), and the incidence rate was 3.7% vs 6.9% patients/year, respectively (log-rank test P = .009). The major bleeding rate was 7.3% (25 of 340) vs 13% (90 of 692) (HR, 0.5; 95% CI, 0.33-0.84; P = .007), and the incidence rate was 2% vs 4% patients/year (log-rank test P = .002.) After propensity score matching, the NOACs vs warfarin embolic/ischemic rate was 13.1% (42 of 321) vs 21.8% (70 of 321) (HR, 0.6; 95% CI, 0.4-0.9; P = .02), and the incidence rate was 4.1% vs 6.7% patients/year (log rank test P = .01). The major bleeding rate was 7.8% (25 of /321) vs 13.7% (44 of 321) (HR, 0.5; 95% CI, 0.31-0.86; P = .01), and the incidence rate was 2.4% vs 4.2% patients/year (log-rank P = .01). Conclusions: In a real-word study, NOACs use overcomes the indications provided by guidelines. This study evidenced that NOACs use in patients who developed AF after bioprosthetic AVR was more effective in prevention of thromboembolism and safe in reduction of major bleeding events compared with warfarin.
- Published
- 2022
7. The role of antibody responses against glycans in bioprosthetic heart valve calcification and deterioration
- Author
-
Thomas Senage, Anu Paul, Thierry Le Tourneau, Imen Fellah-Hebia, Marta Vadori, Salam Bashir, Manuel Galiñanes, Tomaso Bottio, Gino Gerosa, Arturo Evangelista, Luigi P. Badano, Alberto Nassi, Cristina Costa, Galli Cesare, Rizwan A. Manji, Caroline Cueff de Monchy, Nicolas Piriou, Romain Capoulade, Jean-Michel Serfaty, Guillaume Guimbretière, Etienne Dantan, Alejandro Ruiz-Majoral, Guénola Coste du Fou, Shani Leviatan Ben-Arye, Liana Govani, Sharon Yehuda, Shirley Bachar Abramovitch, Ron Amon, Eliran Moshe Reuven, Yafit Atiya-Nasagi, Hai Yu, Laura Iop, Kelly Casós, Sebastián G. Kuguel, Arnau Blasco-Lucas, Eduard Permanyer, Fabrizio Sbraga, Roger Llatjós, Gabriel Moreno-Gonzalez, Melchor Sánchez-Martínez, Michael E. Breimer, Jan Holgersson, Susann Teneberg, Marta Pascual-Gilabert, Alfons Nonell-Canals, Yasuhiro Takeuchi, Xi Chen, Rafael Mañez, Jean-Christian Roussel, Jean-Paul Soulillou, Emanuele Cozzi, Vered Padler-Karavani, unité de recherche de l'institut du thorax UMR1087 UMR6291 (ITX), Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Nantes Université - UFR de Médecine et des Techniques Médicales (Nantes Univ - UFR MEDECINE), Nantes Université - pôle Santé, Nantes Université (Nantes Univ)-Nantes Université (Nantes Univ)-Nantes Université - pôle Santé, Nantes Université (Nantes Univ)-Nantes Université (Nantes Univ), MethodS in Patients-centered outcomes and HEalth ResEarch (SPHERE), Université de Tours (UT)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Nantes Université - UFR des Sciences Pharmaceutiques et Biologiques (Nantes Université - UFR Pharmacie), Tel Aviv University (TAU), Brigham & Women’s Hospital [Boston] (BWH), Harvard Medical School [Boston] (HMS), Università degli Studi di Padova = University of Padua (Unipd), Universitat Autònoma de Barcelona (UAB), Vall d'Hebron University Hospital [Barcelona], Università degli Studi di Milano-Bicocca = University of Milano-Bicocca (UNIMIB), Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Llobregat Hospital [Barcelona], Fondazione Avantea [Cremona, Italy], St. Boniface Hospital Albrechtsen Research Centre [Winnipeg], Israel Institute for Biological Research (IIBR), University of California [Davis] (UC Davis), University of California (UC), Institut d'Investigació Biomèdica de Bellvitge [Barcelone] (IDIBELL), Quironsalud Teknon Heart Institute [Barcelona, Spain] (QTHI), Mind the Byte [Barcelona, Spain], Molomics [Barcelona, Spain], Sahlgrenska Academy at University of Gothenburg [Göteborg], Institut Universitari de Ciència i Tecnologia [Barcelona, Spain] ((Inkemia Group) IUCT), DevsHealth [Barcelona, Spain] (DH), University College of London [London] (UCL), Bellvitge University Hospital [Barcelona, Spain], Centre de Recherche en Transplantation et Immunologie - Center for Research in Transplantation and Translational Immunology (U1064 Inserm - CR2TI), Institut National de la Santé et de la Recherche Médicale (INSERM)-Nantes Université - UFR de Médecine et des Techniques Médicales (Nantes Univ - UFR MEDECINE), Dantan, Etienne, Senage, T, Paul, A, Le Tourneau, T, Fellah-Hebia, I, Vadori, M, Bashir, S, Galinanes, M, Bottio, T, Gerosa, G, Evangelista, A, Badano, L, Nassi, A, Costa, C, Cesare, G, Manji, R, Cueff de Monchy, C, Piriou, N, Capoulade, R, Serfaty, J, Guimbretiere, G, Dantan, E, Ruiz-Majoral, A, Coste du Fou, G, Leviatan Ben-Arye, S, Govani, L, Yehuda, S, Bachar Abramovitch, S, Amon, R, Reuven, E, Atiya-Nasagi, Y, Yu, H, Iop, L, Casos, K, Kuguel, S, Blasco-Lucas, A, Permanyer, E, Sbraga, F, Llatjos, R, Moreno-Gonzalez, G, Sanchez-Martinez, M, Breimer, M, Holgersson, J, Teneberg, S, Pascual-Gilabert, M, Nonell-Canals, A, Takeuchi, Y, Chen, X, Manez, R, Roussel, J, Soulillou, J, Cozzi, E, Padler-Karavani, V, Institut Català de la Salut, [Senage T] Institut du Thorax, Institut National de la Santé et de la Recherche Médicale UMR1087, University Hospital, Nantes, France. Institut National de la Santé et de la Recherche Médicale UMR 1246-SPHERE, Nantes University, Tours University, Nantes, France. [Paul A] Department of Cell Research and Immunology, Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel. Department of Pathology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA. [Le Tourneau T, Fellah-Hebia I] Institut du Thorax, Institut National de la Santé et de la Recherche Médicale UMR1087, University Hospital, Nantes, France. [Vadori M] Consortium for Research in Organ Transplantation, Ospedale Giustinianeo, Padova, Italy. [Bashir S] Department of Cell Research and Immunology, Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel. [Galiñanes M] Servei de Cirurgia Cardíaca, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. [Evangelista A] Servei de Cardiologia, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Casós K] Servei de Cirurgia Cardíaca, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. Infectious Diseases and Transplantation Division, Institut d’Investigació Biomèdica de Bellvitge, L’Hospitalet de Llobregat, Barcelona, Spain. Grup de Recerca en Malalties Cardiovasculars, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. [Blasco-Lucas A] Servei de Cirurgia Cardíaca, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. Cardiac Surgery Department, Bellvitge University Hospital, L’Hospitalet de Llobregat, Barcelona, Spain. [Permanyer E] Servei de Cirurgia Cardíaca, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. Department of Cardiac Surgery, Quironsalud Teknon Heart Institute, Barcelona, Spain, and Vall d'Hebron Barcelona Hospital Campus
- Subjects
[SDV]Life Sciences [q-bio] ,Immunology ,enfermedades cardiovasculares::enfermedades cardíacas [ENFERMEDADES] ,Cardiovascular ,Medical and Health Sciences ,General Biochemistry, Genetics and Molecular Biology ,Mice ,Polysaccharides ,Animals ,Humans ,Prospective Studies ,Polysaccharide ,Bioprosthesi ,Bioprosthesis ,5.3 Medical devices ,Animal ,Calcinosis ,Galactose ,Otros calificadores::Otros calificadores::/cirugía [Otros calificadores] ,MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE ,General Medicine ,Aortic Valve Stenosis ,Aortic Valve Stenosi ,Other subheadings::Other subheadings::/surgery [Other subheadings] ,Vàlvula aòrtica - Cirurgia ,[SDV] Life Sciences [q-bio] ,Cardiovascular Diseases::Heart Diseases [DISEASES] ,Prospective Studie ,Heart Disease ,Aortic Valve ,Immunoglobulin G ,Antibody Formation ,Calcinosi ,Development of treatments and therapeutic interventions ,Immunoglobulines ,Human - Abstract
Outcomes research; Risk factors Investigación de resultados; Factores de riesgo Recerca dels resultats; Factors de risc Bioprosthetic heart valves (BHVs) are commonly used to replace severely diseased heart valves but their susceptibility to structural valve degeneration (SVD) limits their use in young patients. We hypothesized that antibodies against immunogenic glycans present on BHVs, particularly antibodies against the xenoantigens galactose-α1,3-galactose (αGal) and N-glycolylneuraminic acid (Neu5Gc), could mediate their deterioration through calcification. We established a large longitudinal prospective international cohort of patients (n = 1668, 34 ± 43 months of follow-up (0.1–182); 4,998 blood samples) to investigate the hemodynamics and immune responses associated with BHVs up to 15 years after aortic valve replacement. Early signs of SVD appeared in
- Published
- 2021
- Full Text
- View/download PDF
8. Will transcatheter aortic valve implantation represent the choice treatment for all patients who need a biological valve?
- Author
-
Antonio Curcio, Annalisa Mongiardo, Salvatore De Rosa, Carmen Spaccarotella, Ciro Indolfi, Spaccarotella, C., Mongiardo, A., Curcio, A., De Rosa, S., and Indolfi, C.
- Subjects
Male ,medicine.medical_specialty ,Transcatheter aortic ,Clinical Decision-Making ,MEDLINE ,Prosthesis Design ,Severity of Illness Index ,Transcatheter Aortic Valve Replacement ,Postoperative Complications ,Risk Factors ,medicine ,Humans ,Bioprosthesi ,Aged ,Aged, 80 and over ,Bioprosthesis ,business.industry ,Risk Factor ,General Medicine ,Aortic Valve Stenosis ,Recovery of Function ,Aortic Valve Stenosi ,Surgery ,Treatment Outcome ,Aortic Valve ,Heart Valve Prosthesis ,Female ,Postoperative Complication ,Cardiology and Cardiovascular Medicine ,business ,Human - Published
- 2020
9. Meta-analysis of Incidence, Predictors and Consequences of Clinical and Subclinical Bioprosthetic Leaflet Thrombosis After Transcatheter Aortic Valve Implantation
- Author
-
Michael J. Mack, Rebecca T. Hahn, Paul A. Grayburn, Jonathon Leipsic, Anna Sannino, Sannino, A., Hahn, R. T., Leipsic, J., Mack, M. J., and Grayburn, P. A.
- Subjects
medicine.medical_specialty ,Heart Diseases ,MEDLINE ,030204 cardiovascular system & hematology ,Global Health ,Transcatheter Aortic Valve Replacement ,03 medical and health sciences ,Postoperative Complications ,0302 clinical medicine ,Risk Factors ,Internal medicine ,medicine ,Clinical endpoint ,Humans ,030212 general & internal medicine ,Registries ,Stroke ,Bioprosthesi ,Subclinical infection ,Bioprosthesis ,business.industry ,Incidence (epidemiology) ,Incidence ,Risk Factor ,Thrombosis ,Aortic Valve Stenosis ,medicine.disease ,Aortic Valve Stenosi ,Confidence interval ,Heart Disease ,Meta-analysis ,Thrombosi ,Cardiology ,Postoperative Complication ,Cardiology and Cardiovascular Medicine ,business ,Human - Abstract
Leaflet thrombosis (LT) has been claimed as a potential cause of hemodynamic dysfunction or bioprosthetic valve degeneration of transcatheter heart valves. Sparse and contrasting evidence exists, however, regarding LT occurrence, prevention and treatment. MEDLINE, ISI Web of Science and SCOPUS databases were searched for studies published up to January 2020. Only studies reporting data on incidence and outcomes associated to the presence/absence of clinical or subclinical LT, detected or confirmed with a multidetector computed tomography exam were included. The study was designed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) requirements. Two reviewers independently screened articles for fulfillment of inclusion criteria. Data were pooled using a random-effect model. The primary end point was the incidence of LT. Secondary outcomes included: stroke and transient ischemic attacks and mean transvalvular gradients at different time-points in patients with and without LT. Of the initial 200 studies, 22 were finally included with a total of 11,567 patients. LT overall incidence was 8% (95% Confidence Interval [CI]: 5% to 13%, I2 = 96.4%). LT incidence in patients receiving only antiplatelets was 13% (95% CI: 7% to 23%, p
- Published
- 2020
10. Multimodality Imaging for Transcatheter Paravalvular Leak Closure in Radiolucent Mitral Bioprosthesis
- Author
-
Stefano Stella, Eustachio Agricola, Alessandro Beneduce, Cristina Capogrosso, Marco Ancona, Francesco Ancona, Vittorio Romano, Matteo Montorfano, Beneduce, A., Ancona, F., Ancona, M. B., Romano, V., Stella, S., Capogrosso, C., Montorfano, M., and Agricola, E.
- Subjects
Male ,mitral valve ,medicine.medical_specialty ,Radiodensity ,Echocardiography, Three-Dimensional ,Heart Valve Diseases ,Closure (topology) ,heart failure ,multimodal imaging ,Multimodal Imaging ,Mitral valve ,Humans ,Medicine ,Radiology, Nuclear Medicine and imaging ,Paravalvular leak ,Aged ,Multimodal imaging ,business.industry ,fiducial marker ,Echocardiography, Doppler, Color ,Prosthesis Failure ,Treatment Outcome ,medicine.anatomical_structure ,bioprosthesi ,Mitral Valve ,Radiology ,Cardiology and Cardiovascular Medicine ,Fiducial marker ,business ,Echocardiography, Transesophageal - Published
- 2019
- Full Text
- View/download PDF
11. Aortic Valve Replacement in Elderly Patients with Small Aortic Annulus: Results with Three Different Bioprostheses
- Author
-
Chiariello, G. A., Bruno, P., Villa, E., Pasquini, Annalisa, Pavone, Natalia, Cammertoni, F., Mazza, A., Colizzi, Christian, Nesta, Marialisa, Iafrancesco, M., Perri, Gianluigi, Messina, A., Troise, Giovanni, Massetti, Massimo, Pasquini A., Pavone N., Colizzi C., Nesta M., Perri G., Troise G., Massetti M. (ORCID:0000-0002-7100-8478), Chiariello, G. A., Bruno, P., Villa, E., Pasquini, Annalisa, Pavone, Natalia, Cammertoni, F., Mazza, A., Colizzi, Christian, Nesta, Marialisa, Iafrancesco, M., Perri, Gianluigi, Messina, A., Troise, Giovanni, Massetti, Massimo, Pasquini A., Pavone N., Colizzi C., Nesta M., Perri G., Troise G., and Massetti M. (ORCID:0000-0002-7100-8478)
- Abstract
Objectives Aortic valve replacement (AVR) in patients with small aortic annulus (diameter ≤21 mm) is considered a challenging scenario because of technical aspects and the high risk of patient-prosthesis mismatch (PPM). The choice of the appropriate prosthesis is crucial, and at the moment, an ideal device has yet to be identified. We compare clinical and hemodynamic results after AVR with three bioprostheses with different design and characteristics. Methods We retrospectively evaluated 76 consecutive patients from two cardiac surgery centers who underwent AVR (Trifecta = 24; Edwards INTUITY Elite valve system = 26, and Perceval = 26) for severe aortic stenosis between 2013 and 2017. Patients selected were older than 75 years and with an annulus diameter ≤21 mm at preoperative echocardiogram. Reinterventions and combined procedures were excluded. Minimally invasive AVR was performed in 44 (57.8%) patients. Telephonic interview was obtained at 2.9 ± 0.5 years and echocardiographic follow-up at 2.2 ± 0.8 years. Results Clinical outcome was similar in the three groups. At follow-up, Trifecta patients presented significantly higher peak and mean transprosthetic pressure gradients (P = 0.04 and 0.01). Effective orifice area and left ventricular mass regression were comparable, although an advantage was observed in Perceval patients without reaching the statistical significance. Incidence of moderate (P = 0.2) and severe PPM (P = 0.7) was comparable. Conclusions Despite higher postoperative pressure gradients observed with the Trifecta valve, all three prostheses (Trifecta, Edwards INTUITY Elite, and Perceval) have proven to be reliable when implanted in small aortic annuli, with good clinical outcome and favorable left ventricular mass regression.
- Published
- 2019
12. Nucleotide Catabolism on the Surface of Aortic Valve Xenografts; Effects of Different Decellularization Strategies
- Author
-
Patricia M. Taylor, Paulina Zukowska, Magdi H. Yacoub, Marialuisa Lavitrano, Albert Heacox, Steven Goldstein, Zain Khalpey, Ryszard T. Smolenski, Adrian H. Chester, Ewa M. Slominska, Barbara Kutryb-Zajac, Ada H.Y. Yuen, Kutryb-Zajac, B, Yuen, A, Khalpey, Z, Zukowska, P, Slominska, E, Taylor, P, Goldstein, S, Heacox, A, Lavitrano, M, Chester, A, Yacoub, M, Smolenski, R, and The Magdi Yacoub Institute
- Subjects
0301 basic medicine ,Aortic valve ,Cardiac & Cardiovascular Systems ,Adenosine ,Swine ,Pharmaceutical Science ,(Max 10) heart valves ,Research & Experimental Medicine ,Hypotonic Solution ,030204 cardiovascular system & hematology ,Nucleotide metabolism ,chemistry.chemical_compound ,Adenosine Triphosphate ,0302 clinical medicine ,Nucleotidases ,ATP hydrolysis ,Genetics(clinical) ,Aorta ,Chromatography, High Pressure Liquid ,Genetics (clinical) ,ECTO-5'-NUCLEOTIDASE ,Xenografts ,Decellularization ,HEART-VALVE ,Hydrolysis ,MED/04 - PATOLOGIA GENERALE ,Sodium Dodecyl Sulfate ,PULMONARY HOMOGRAFT ,REPLACEMENT ,medicine.anatomical_structure ,Hypotonic Solutions ,Medicine, Research & Experimental ,Biochemistry ,Deamination ,Heart Valve Prosthesis ,Aortic Valve ,Heterografts ,Molecular Medicine ,Original Article ,Tissue Preservation ,Heterograft ,Cardiology and Cardiovascular Medicine ,Life Sciences & Biomedicine ,medicine.drug ,Adenosine monophosphate ,Detergent ,Detergents ,Biology ,1ST ,Valve prostheses ,HUMAN ENDOTHELIAL-CELLS ,03 medical and health sciences ,Genetic ,medicine.artery ,Nucleotidase ,Genetics ,medicine ,Extracellular ,Animals ,Deoxyribonuclease I ,Heart valve ,HIGH-RISK PATIENTS ,Bioprosthesi ,Valve prosthese ,Bioprosthesis ,Kinetic ,Science & Technology ,Animal ,Xenograft ,Ribonuclease, Pancreatic ,PERFORMANCE ,Hydrolysi ,Adenosine Monophosphate ,ATP ,Kinetics ,ROSS PROCEDURE ,Heart Valve Prosthesi ,030104 developmental biology ,chemistry ,Cardiovascular System & Cardiology ,(Max 10) heart valve - Abstract
Extracellular nucleotide metabolism controls thrombosis and inflammation and may affect degeneration and calcification of aortic valve prostheses. We evaluated the effect of different decellularization strategies on enzyme activities involved in extracellular nucleotide metabolism. Porcine valves were tested intact or decellularized either by detergent treatment or hypotonic lysis and nuclease digestion. The rates of ATP hydrolysis, AMP hydrolysis, and adenosine deamination were estimated by incubation of aorta or valve leaflet sections with substrates followed by HPLC analysis. We demonstrated relatively high activities of ecto-enzymes on porcine valve as compared to the aortic wall. Hypotonic lysis/nuclease digestion preserved >80 % of ATP and AMP hydrolytic activity but reduced adenosine deamination to
- Published
- 2016
- Full Text
- View/download PDF
13. Exercise Hemodynamic and Functional Capacity After Mitral Valve Replacement in Patients With Ischemic Mitral Regurgitation: A Comparison of Mechanical Versus Biological Prostheses
- Author
-
Fino, C, Iacovoni, A, Pibarot, P, Pepper, J, Ferrero, P, Merlo, M, Galletti, L, Caputo, M, Ferrazzi, P, Anagnostopoulos, C, Cugola, D, Senni, M, Bellavia, D, Magne, J, Fino C, Iacovoni A, Pibarot P, Pepper JR, Ferrero P, Merlo M, Galletti L, Caputo M, Ferrazzi P, Anagnostopoulos C, Cugola D, Senni M, Bellavia D, Magne J, Fino, C, Iacovoni, A, Pibarot, P, Pepper, J, Ferrero, P, Merlo, M, Galletti, L, Caputo, M, Ferrazzi, P, Anagnostopoulos, C, Cugola, D, Senni, M, Bellavia, D, Magne, J, Fino C, Iacovoni A, Pibarot P, Pepper JR, Ferrero P, Merlo M, Galletti L, Caputo M, Ferrazzi P, Anagnostopoulos C, Cugola D, Senni M, Bellavia D, and Magne J
- Abstract
BACKGROUND: In patients with ischemic mitral regurgitation requiring mitral valve replacement (MVR), the choice of the prosthesis type is crucial. The exercise hemodynamic and functional capacity performance in patients with contemporary prostheses have never been investigated. To compare exercise hemodynamic and functional capacity between biological (MVRb) and mechanical (MVRm) prostheses. METHODS AND RESULTS: We analyzed 86 consecutive patients with ischemic mitral regurgitation who underwent MVRb (n=41) or MVRm (n=45) and coronary artery bypass grafting. All patients underwent preoperative resting echocardiography and 6-minute walking test. At follow-up, exercise stress echocardiography was performed, and the 6-minute walking test was repeated. Resting and exercise indexed effective orifice areas of MVRm were larger when compared with MVRb (resting: 1.30±0.2 versus 1.19±0.3 cm 2 /m 2 ; P=0.03; exercise: 1.57±0.2 versus 1.18±0.3 cm 2 /m 2 ; P=0.0001). The MVRm had lower exercise systolic pulmonary arterial pressure at follow-up compared with MVRb (41±5 versus 59±7 mm Hg; P=0.0001). Six-minute walking test distance was improved in the MVRm (pre-operative: 242±43, post-operative: 290±50 m; P=0.001), whereas it remained similar in the MVRb (pre-operative: 250±40, post-operative: 220±44 m; P=0.13). In multivariable analysis, type of prosthesis, exercise indexed effective orifice area, and systolic pulmonary arterial pressure were joint predictors of change in 6-minute walking test (ie, difference between baseline and follow-up). CONCLUSIONS: In patients with ischemic mitral regurgitation, bioprostheses are associated with worse hemodynamic performance and reduced functional capacity, when compared with MVRm. Randomized studies with longer follow-up including quality of life and survival data are required to confirm these results.
- Published
- 2018
14. One-year outcomes after rapid-deployment aortic valve replacement
- Author
-
Young, Christopher, Laufer, Günther, Kocher, Alfred, Solinas, Marco, Alamanni, Francesco, Polvani, Gianluca, Podesser, Bruno K, Aramendi, Jose Ignacio, Arribas, Jose, Bouchot, Olivier, Livi, Ugolino, Massetti, Massimo, Terp, Kim, Giot, Christophe, Glauber, Mattia, Massetti, Massimo (ORCID:0000-0002-7100-8478), Young, Christopher, Laufer, Günther, Kocher, Alfred, Solinas, Marco, Alamanni, Francesco, Polvani, Gianluca, Podesser, Bruno K, Aramendi, Jose Ignacio, Arribas, Jose, Bouchot, Olivier, Livi, Ugolino, Massetti, Massimo, Terp, Kim, Giot, Christophe, Glauber, Mattia, and Massetti, Massimo (ORCID:0000-0002-7100-8478)
- Abstract
OBJECTIVE: The goals of rapid-deployment aortic valve replacement include facilitation of minimally invasive surgery and reduced aortic crossclamp time. We report the short-term outcomes of a series of 493 patients undergoing rapid-deployment aortic valve replacement with the EDWARDS INTUITY valve system (Edwards Lifesciences, LLC, Irvine, Calif). METHODS: Assessing Standard oF Care and Clinical Outcomes UsiNg the EDWARDS INTUITY VAlve SysTem in a European multI-center, Active, pOst-market surveillaNce Study was a prospective, multicenter (n = 26) European registry designed to evaluate the safety and performance of the valve system. During rapid-deployment aortic valve replacement, device technical success and crossclamp time were assessed. Procedural outcomes, hemodynamic performance, and various adverse events and clinical outcomes were evaluated up to 2 years. RESULTS: Between 2012 and 2014, 493 of 517 enrolled patients successfully received implants with the study valve (95.4% technical success). Mean crossclamp times for 163 full sternotomies, 128 mini-upper sternotomies, and 36 right anterior thoracotomies isolated aortic valve replacements were 47.3, 52.0, and 73.3 minutes, respectively. Mean follow-up was 1.8 years, with 870 total patient-years of follow-up. Mean effective orifice area increased from 0.72 (baseline) to 1.88 cm2, and mean pressure gradient decreased from 47.6 to 9.6 mm Hg (1 year). Mean effective orifice area index increased (0.39-1.01 cm2/m2), and 28 of 287 patients (9.8%) exhibited severe prosthesis-patient mismatch at 1 year. After 1 year, 68.1% and 21.7% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major perivalvular leak, reoperation, and device explant at 1 year were 0.935, 0.939, 0.976, 0.975, and 0.983, respectively. CONCLUSIONS:These results demonstrate commendable safety and performance of the test valve system over the short term in a broad European settin
- Published
- 2018
15. Transcatheter Mitral Valve Replacement for Degenerated Bioprosthetic Valves and Failed Annuloplasty Rings
- Author
-
Marco Ancona, Masahiko Asami, Tarun Chakravarty, Victoria Delgado, Joachim Schofer, Stephan Ensminger, James E. Davies, Michael J. Reardon, Antonio Colombo, Rajiv Rampat, Thomas Pilgrim, Florian Deuschl, Jeroen J. Bax, Daniel J. Blackman, Lena Eschenbach, Harindra C. Wijeysundera, Saibal Kar, Niklas Schofer, Ermela Yzeiraj, Buntaro Fujita, Luis Nombela-Franco, Abhijeet Dhoble, Raj Makkar, Francesco Maisano, Horst Sievert, Stefano Cannata, Brian Whisenant, Sabine Bleiziffer, Anthony C. Chyou, Azeem Latib, Antonio H. Frangieh, Sung Han Yoon, Jean Bernard Masson, David Hildick-Smith, Christian Hengstenberg, Enrique Gutiérrez-Ibañes, Stephan Windecker, Tsuyoshi Kaneko, Lenard Conradi, Guiherme F. Attizzani, S. Chiu Wong, Ulrich Schaefer, Maurizio Taramasso, Colin MacLeod Barker, Tomaz Podlesnikar, Albert M. Kasel, Bernard Prendergast, Simon Redwood, Fabian Nietlispach, Rahul Sharma, Yoon, Sung-han, Whisenant, Brian K., Bleiziffer, Sabine, Delgado, Victoria, Schofer, Nikla, Eschenbach, Lena, Fujita, Buntaro, Sharma, Rahul, Ancona, Marco, Yzeiraj, Ermela, Cannata, Stefano, Barker, Colin, Davies, James E., Frangieh, Antonio H., Deuschl, Florian, Podlesnikar, Tomaz, Asami, Masahiko, Dhoble, Abhijeet, Chyou, Anthony, Masson, Jean-bernard, Wijeysundera, Harindra C., Blackman, Daniel J., Rampat, Rajiv, Taramasso, Maurizio, Gutierrez-ibanes, Enrique, Chakravarty, Tarun, Attizzani, Guiherme F., Kaneko, Tsuyoshi, Wong, S. Chiu, Sievert, Horst, Nietlispach, Fabian, Hildick-smith, David, Nombela-franco, Lui, Conradi, Lenard, Hengstenberg, Christian, Reardon, Michael J., Kasel, Albert Marku, Redwood, Simon, Colombo, Antonio, Kar, Saibal, Maisano, Francesco, Windecker, Stephan, Pilgrim, Thoma, Ensminger, Stephan M., Prendergast, Bernard D., Schofer, Joachim, Schaefer, Ulrich, Bax, Jeroen J., Latib, Azeem, and Makkar, Raj R
- Subjects
Male ,Reoperation ,mitral valve ,medicine.medical_specialty ,Cardiac Catheterization ,Mitral Valve Annuloplasty ,medicine.medical_treatment ,Heart Valve Diseases ,Annuloplasty rings ,030204 cardiovascular system & hematology ,Valve in ring ,Prosthesis Design ,degenerated bioprosthese ,03 medical and health sciences ,0302 clinical medicine ,Retrospective Studie ,transcatheter valve implantation ,Mitral valve ,Internal medicine ,medicine ,Humans ,In patient ,030212 general & internal medicine ,610 Medicine & health ,Bioprosthesi ,Retrospective Studies ,Aged ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,Ejection fraction ,business.industry ,Mitral valve replacement ,annuloplasty ring ,Prosthesis Failure ,Europe ,Survival Rate ,Heart Valve Disease ,medicine.anatomical_structure ,Treatment Outcome ,degenerated bioprostheses ,North America ,Cardiology ,Female ,business ,Cardiology and Cardiovascular Medicine ,Human - Abstract
Background Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. Objectives This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). Methods From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. Results A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). Conclusions The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.
- Published
- 2017
16. Patterns of use and durability for the Mitroflow aortic valve: a systematic review of the literature
- Author
-
Giuseppe Santarpino, Steffen Pfeiffer, Vincenzo Bagnardi, Theodor Fischlein, Fischlein, T, Pfeiffer, S, Bagnardi, V, and Santarpino, G
- Subjects
Aortic valve ,Male ,medicine.medical_specialty ,Meta-Analysi ,Time Factors ,Time Factor ,Treatment outcome ,Heart Valve Diseases ,030204 cardiovascular system & hematology ,Prosthesis Design ,03 medical and health sciences ,0302 clinical medicine ,Risk Factors ,Internal medicine ,medicine ,Prosthesis design ,Humans ,In patient ,Hemodynamic ,Practice Patterns, Physicians' ,Bioprosthesi ,Aged ,Prosthetic valve ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,business.industry ,Risk Factor ,Hemodynamics ,General Medicine ,Middle Aged ,Transcatheter aortic valve replacement ,Prosthesis Failure ,Heart Valve Disease ,medicine.anatomical_structure ,Heart Valve Prosthesi ,Treatment Outcome ,030228 respiratory system ,Meta-analysis ,Aortic Valve ,Heart Valve Prosthesis ,Aortic valve surgery ,Cardiology ,Surgery ,Female ,business ,Cardiology and Cardiovascular Medicine ,Evidence synthesis ,Human - Abstract
Introduction The aim of this study was to evaluate durability of Mitroflow and patterns of use compared with other aortic valves through a systematic review of the literature. Evidence acquisition A total of 52 papers that included 33,630 patients met eligibility requirements that allowed summary statistical information to be determined regarding structural valve degeneration risk. Evidence synthesis Mitroflow has been disporportionately implanted in patients to be at higher risk for structural valve degeneration. Conclusions Since Mitroflow valves were implanted more often in these high-risk patients, it was impossible to distinguish the effects of valve size or gender from valve type on structural valve degeneration risk.
- Published
- 2017
17. The Conundrum of Permanent Pacemaker Implantation after Transcatheter Aortic Valve Implantation
- Author
-
Stephan Windecker, Anna Franzone, Franzone, Anna, and Windecker, Stephan
- Subjects
Aortic valve ,medicine.medical_specialty ,Pacemaker, Artificial ,Heart block ,medicine.medical_treatment ,Context (language use) ,030204 cardiovascular system & hematology ,Cardiac pacemaker ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,medicine ,Ventricular outflow tract ,030212 general & internal medicine ,Cardiac skeleton ,610 Medicine & health ,business.industry ,Atrial fibrillation ,medicine.disease ,Surgery ,Stenosis ,medicine.anatomical_structure ,Editorial ,Echocardiography ,Aortic Valve ,Heart Valve Prosthesis ,bioprosthesi ,cardiovascular system ,Cardiology ,transcatheter aortic valve replacement ,business ,Cardiology and Cardiovascular Medicine ,cardiac pacemaker - Abstract
Transcatheter aortic valve implantation (TAVI) has matured into the preferred treatment modality for patients with severe aortic stenosis at extreme or high risk for conventional surgery and a valuable alternative for those at intermediate risk in view of similar or superior clinical outcomes and decreased rates of periprocedural adverse events.1–3 In this context, it remains unclear whether other procedure-related events—including atrioventricular conduction disturbances that require permanent pacemaker (PPM) implantation—are of prognostic relevance. See Article by Mohananey et al In the natural history of aortic stenosis, variable degrees of heart block may occur with calcium deposits expanding progressively from the left ventricular outflow tract to the atrioventricular conduction system. As matter of fact, a PPM is already present in ≈10% to ≈20% of patients with severe aortic stenosis at the time of transcatheter or surgical intervention.4 Because of its proximity to the aortic root, iatrogenic injury to the atrioventricular conduction system also occurs after surgical bioprosthesis implantation, with comparable PPM rates for TAVI and surgery reported in the PARTNER trials (Placement of Aortic Transcatheter Valves).2,5 Several patient- and procedure-related factors have been associated with PPM implantation after TAVI and include advanced age, male gender, atrial fibrillation, calcification of aortic and mitral annulus, small left ventricular outflow tract, pre-procedural or intraprocedural conduction disorders, balloon pre-dilation, and depth of prosthesis implantation.6,7 In addition, the type of transcatheter bioprosthesis plays an important role with rates of PPM implantation progressively increasing from balloon-expandable prostheses over self-expanding prostheses to mechanically deployed prostheses.8 Along this line, outer skirts and adaptive seals surrounding the inflow portion, designed to reduce paravalvular leaks, as well as features that allow for repositionability of the device within the aortic annulus, may modify the risk of atrioventricular conduction disturbances after TAVI. Despite …
- Published
- 2017
18. Patterns of use and durability for the Mitroflow aortic valve: A systematic review of the literature
- Author
-
Fischlein, T, Pfeiffer, S, Bagnardi, V, Santarpino, G, Fischlein, T, Pfeiffer, S, Bagnardi, V, and Santarpino, G
- Abstract
INTRODUCTION: The aim of this study was to evaluate durability of Mitroflow and patterns of use compared with other aortic valves through a systematic review of the literature. EVIDENCE ACQUISITION: A total of 52 papers that included 33,630 patients met eligibility requirements that allowed summary statistical information to be determined regarding structural valve degeneration risk. EVIDENCE SYNTHESIS: Mitroflow has been disporportionately implanted in patients to be at higher risk for structural valve degeneration. CONCLUSIONS: Since Mitroflow valves were implanted more often in these high-risk patients, it was impossible to distinguish the effects of valve size or gender from valve type on structural valve degeneration risk.
- Published
- 2017
19. Left ventricular pseudoaneurysm after transapical aortic valve-in-valve implantation: Use of transthoracic 3D echocardiography for guiding therapeutic approach
- Author
-
Luigi P. Badano, Massimo Napodano, Denisa Muraru, Valeria Beltrame, Muraru, D, Napodano, M, Beltrame, V, and Badano, L
- Subjects
Aortic valve ,Male ,Reoperation ,medicine.medical_specialty ,Computed Tomography Angiography ,Echocardiography, Three-Dimensional ,030204 cardiovascular system & hematology ,Multimodal Imaging ,Transcatheter Aortic Valve Replacement ,03 medical and health sciences ,Pseudoaneurysm ,Postoperative Complications ,0302 clinical medicine ,Internal medicine ,medicine.artery ,Occlusion ,medicine ,Humans ,Thrombus ,Heart Aneurysm ,Bioprosthesi ,Ultrasonography, Interventional ,Computed tomography angiography ,Aged ,Bioprosthesis ,Aorta ,medicine.diagnostic_test ,business.industry ,MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE ,medicine.disease ,Surgery ,Prosthesis Failure ,medicine.anatomical_structure ,Surgery, Computer-Assisted ,Ventricle ,Aortic Valve ,Cardiology ,Postoperative Complication ,business ,Cardiology and Cardiovascular Medicine ,030217 neurology & neurosurgery ,Aneurysm, False ,Human - Abstract
A 75-year-old man with symptomatic severe degeneration of aortic bioprosthesis and high surgical risk (STS score = 18) underwent transapical ‘valve-in-valve’ TAVI. The procedure was complicated by local bleeding and occlusion of distal left anterior descendent artery. A month later, the patient developed orthopnoea and dizziness. Due to the sequelae of previous surgery, only subcostal acoustic window was adequate for imaging. Two- and three-dimensional echocardiography (3DE) showed a large apical pseudoaneurysm (PsA) of the left ventricle ( Panel A , Supplementary material online, Video S1 ) with bidirectional flow ( Panel B , Supplementary material online, Video S2 ) and layered thrombus. Re-aligning the …
- Published
- 2016
20. Nucleotide Catabolism on the Surface of Aortic Valve Xenografts; Effects of Different Decellularization Strategies
- Author
-
Kutryb-Zajac, B, Yuen, A, Khalpey, Z, Zukowska, P, Slominska, E, Taylor, P, Goldstein, S, Heacox, A, Lavitrano, M, Chester, A, Yacoub, M, Smolenski, R, Yuen, AHY, Slominska, EM, Taylor, PM, Heacox, AE, Chester, AH, Yacoub, MH, Smolenski, RT, Kutryb-Zajac, B, Yuen, A, Khalpey, Z, Zukowska, P, Slominska, E, Taylor, P, Goldstein, S, Heacox, A, Lavitrano, M, Chester, A, Yacoub, M, Smolenski, R, Yuen, AHY, Slominska, EM, Taylor, PM, Heacox, AE, Chester, AH, Yacoub, MH, and Smolenski, RT
- Abstract
Extracellular nucleotide metabolism controls thrombosis and inflammation and may affect degeneration and calcification of aortic valve prostheses. We evaluated the effect of different decellularization strategies on enzyme activities involved in extracellular nucleotide metabolism. Porcine valves were tested intact or decellularized either by detergent treatment or hypotonic lysis and nuclease digestion. The rates of ATP hydrolysis, AMP hydrolysis, and adenosine deamination were estimated by incubation of aorta or valve leaflet sections with substrates followed by HPLC analysis. We demonstrated relatively high activities of ecto-enzymes on porcine valve as compared to the aortic wall. Hypotonic lysis/nuclease digestion preserved >80 % of ATP and AMP hydrolytic activity but reduced adenosine deamination to <10 %. Detergent decellularization completely removed (<5 %) all these activities. These results demonstrate high intensity of extracellular nucleotide metabolism on valve surface and indicate that various valve decellularization techniques differently affect ecto-enzyme activities that could be important in the development of improved valve prostheses.
- Published
- 2016
21. Left ventricular pseudoaneurysm after transapical aortic valve-in-valve implantation: Use of transthoracic 3D echocardiography for guiding therapeutic approach
- Author
-
Muraru, D, Napodano, M, Beltrame, V, Badano, L, Muraru D., Napodano M., Beltrame V., Badano L., Muraru, D, Napodano, M, Beltrame, V, Badano, L, Muraru D., Napodano M., Beltrame V., and Badano L.
- Published
- 2016
22. Treatment and clinical outcomes of transcatheter heart valve thrombosis
- Author
-
Gert Richardt, Mohamed Abdel-Wahab, Marco Barbanti, Helmut Baumgartner, Haim D. Danenberg, Joelle Kefer, José Suárez de Lezo, Antonio Colombo, David Messika-Zeitoun, Azeem Latib, John G. Webb, Linda Cota, Eugenio Stabile, Alec Vahanian, Vasileios F. Panoulas, Jean Claude Laborde, Victor Legrand, Toru Naganuma, Ariel Finkelstein, Ottavio Alfieri, Martin B. Leon, Francesco Maisano, Gerrit Kaleschke, Latib, Azeem, Naganuma, Toru, Abdel Wahab, Mohamed, Danenberg, Haim, Cota, Linda, Barbanti, Marco, Baumgartner, Helmut, Finkelstein, Ariel, Legrand, Victor, de Lezo, José Suárez, Kefer, Joelle, Messika Zeitoun, David, Richardt, Gert, Stabile, Eugenio, Kaleschke, Gerrit, Vahanian, Alec, Laborde, Jean Claude, Leon, Martin B, Webb, John G, Panoulas, Vasileios F, Maisano, Francesco, Alfieri, Ottavio, Colombo, Antonio, Latib, A, Naganuma, T, Abdel Wahab, M, Danenberg, H, Cota, L, Barbanti, M, Baumgartner, H, Finkelstein, A, Legrand, V, Suarez de Lezo, J, Kefer, J, Messika Zeitoun, D, Richardt, G, Stabile, E, Kaleschke, G, Vahanian, A, Laborde, Jc, Leon, Mb, Webb, Jg, Panoulas Vasileios, F, Maisano, F, Colombo, A., and University of Zurich
- Subjects
Aortic valve ,Male ,medicine.medical_specialty ,Time Factor ,610 Medicine & health ,2705 Cardiology and Cardiovascular Medicine ,Transcatheter Aortic Valve Replacement ,Electrocardiography ,Interquartile range ,Internal medicine ,medicine ,Prevalence ,echocardiography ,Heart valve ,Thrombus ,Aged ,Aged, 80 and over ,medicine.diagnostic_test ,business.industry ,anticoagulant ,aortic valve stenosi ,medicine.disease ,Thrombosis ,Surgery ,10020 Clinic for Cardiac Surgery ,medicine.anatomical_structure ,Treatment Outcome ,Italy ,Aortic valve stenosis ,bioprosthesi ,Thrombosi ,Cardiology ,Female ,Postoperative Complication ,Cohort Studie ,Cardiology and Cardiovascular Medicine ,business ,Cohort study ,Human - Abstract
Background— Valve thrombosis has yet to be fully evaluated after transcatheter aortic valve implantation. This study aimed to report the prevalence, timing, and treatment of transcatheter heart valve (THV) thrombosis. Methods and Results— THV thrombosis was defined as follows (1) THV dysfunction secondary to thrombosis diagnosed based on response to anticoagulation therapy, imaging modality or histopathology findings, or (2) mobile mass detected on THV suspicious of thrombus, irrespective of dysfunction and in absence of infection. Between January 2008 and September 2013, 26 (0.61%) THV thromboses were reported out of 4266 patients undergoing transcatheter aortic valve implantation in 12 centers. Of the 26 cases detected, 20 were detected in the Edwards Sapien/Sapien XT cohort and 6 in the Medtronic CoreValve cohort. In patients diagnosed with THV thrombosis, the median time to THV thrombosis post–transcatheter aortic valve implantation was 181 days (interquartile range, 45–313). The most common clinical presentation was exertional dyspnea (n=17; 65%), whereas 8 (31%) patients had no worsening symptoms. Echocardiographic findings included a markedly elevated mean aortic valve pressure gradient (40.5±14.0 mm Hg), presence of thickened leaflets or thrombotic apposition of leaflets in 20 (77%) and a thrombotic mass on the leaflets in the remaining 6 (23%) patients. In 23 (88%) patients, anticoagulation resulted in a significant decrease of the aortic valve pressure gradient within 2 months. Conclusions— THV thrombosis is a rare phenomenon that was detected within the first 2 years after transcatheter aortic valve implantation and usually presented with dyspnea and increased gradients. Anticoagulation seems to have been effective and should be considered even in patients without visible thrombus on echocardiography.
- Published
- 2015
23. The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation vs (C)arpentier Magna-Ease in (A)ortic position†
- Author
-
Francesco Nicolini, Gino Gerosa, Domenico Mangino, Mauro Rinaldi, Luca Di Marco, Marco Agrifoglio, Giovanni Marchetto, Davide Pacini, Fabio Zucchetta, Stefano Salizzoni, Sara Balduzzi, Tiziano Gherli, Giampaolo Zoffoli, Erica Manzan, Roberto Di Bartolomeo, Georgette Khoury, Mário Jorge Amorim, Marcella De Paolis, Andrea Colli, Valentino Borghetti, Colli, Andrea, Marchetto, Giovanni, Salizzoni, Stefano, Rinaldi, Mauro, DI MARCO, Luca, Pacini, Davide, DI BARTOLOMEO, Roberto, Nicolini, Francesco, Gherli, Tiziano, Agrifoglio, Marco, Borghetti, Valentino, Khoury, Georgette, De Paolis, Marcella, Zoffoli, Giampaolo, Mangino, Domenico, Amorim, Mario Jorge, Manzan, Erica, Zucchetta, Fabio, Balduzzi, Sara, and Gerosa, Gino
- Subjects
Aortic valve ,Pulmonary and Respiratory Medicine ,Male ,medicine.medical_specialty ,medicine.medical_treatment ,Hemodynamics ,030204 cardiovascular system & hematology ,Prosthesis Design ,Prosthesis ,Preoperative care ,Patient-prosthesis mismatch ,03 medical and health sciences ,0302 clinical medicine ,Tissue valve ,Aortic valve replacement ,Interquartile range ,Internal medicine ,Prosthesis Fitting ,medicine ,Humans ,Hospital Mortality ,Bioprosthesis ,Magna Ease ,Trifecta ,Aged ,Aortic Valve ,Aortic Valve Stenosis ,Echocardiography ,Female ,Heart Valve Prosthesis Implantation ,Retrospective Studies ,Heart Valve Prosthesis ,Surgery ,Cardiology and Cardiovascular Medicine ,Bioprosthesi ,Ejection fraction ,business.industry ,General Medicine ,medicine.disease ,medicine.anatomical_structure ,030228 respiratory system ,Aortic valve stenosis ,Cardiology ,business - Abstract
OBJECTIVE To determine whether the Trifecta bioprosthetic aortic valve produces postoperative haemodynamic results comparable with or better than those of the Magna Ease aortic valve bioprosthesis. METHODS We retrospectively reviewed the medical records of patients who had undergone aortic valve replacement with Trifecta or Magna Ease prostheses at eight European institutions between January 2011 and May 2013, and analysed early postoperative haemodynamic performance by means of echocardiography. RESULTS A total of 791 patients underwent aortic valve replacement (469 Magna Ease, 322 Trifecta). Haemodynamic variables were evaluated on discharge and during the follow-up (minimum 6 months, maximum 12 months). The mean gradient and the indexed effective orifice area (IEOA) were as follows: 10 mmHg [interquartile range (IQR): 8-13] and 1.10 cm(2)/m(2) (IQR: 0.95-1.27) for Trifecta; 16 mmHg (IQR: 11-22) and 0.96 cm(2)/m(2) (IQR: 0.77-1.13) for Magna Ease (P < 0.001). These significant differences were maintained across all valve sizes. Similar statistically significant differences were found when patients were matched and/or stratified for preoperative characteristics: body-surface area, ejection fraction, mean gradients and valve size. Severe prosthesis-patient mismatch (IEOA
- Published
- 2015
24. Transcatheter aortic valve implantation with a self-expanding nitinol bioprosthesis: prediction of the need for permanent pacemaker using simple baseline and procedural characteristics
- Author
-
Roberto Kalil Filho, Nevio Taglieri, Antonio Marzocchi, Pedro A. Lemos, Cristina Ciuca, Barbara Bordoni, Francesco Saia, Giuseppe Boriani, Elena Cervi, José Mariani, Saia F, Lemos PA, Bordoni B, Cervi E, Boriani G, Ciuca C, Taglieri N, Mariani J Jr, Filho RK, and Marzocchi A.
- Subjects
Male ,Cardiac Catheterization ,Time Factors ,medicine.medical_treatment ,AORTIC STENOSIS ,Bioprosthesis ,ELECTROCARDIOGRAPHY ,Prosthesis ,Severity of Illness Index ,Cohort Studies ,Electrocardiography ,Postoperative Complications ,Aortic valve replacement ,Medicine ,Prospective Studies ,Aged, 80 and over ,Heart Valve Prosthesis Implantation ,medicine.diagnostic_test ,Incidence (epidemiology) ,Cardiac Pacing, Artificial ,General Medicine ,Echocardiography, Doppler ,Survival Rate ,medicine.anatomical_structure ,Treatment Outcome ,Italy ,Heart Valve Prosthesis ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,medicine.medical_specialty ,Transcatheter aortic ,Prosthesis Design ,Risk Assessment ,Predictive Value of Tests ,Internal medicine ,Preoperative Care ,Alloys ,Humans ,Minimally Invasive Surgical Procedures ,Radiology, Nuclear Medicine and imaging ,Interventricular septum ,Bioprosthesi ,Aged ,Analysis of Variance ,business.industry ,Aortic Valve Stenosis ,medicine.disease ,Surgery ,Logistic Models ,Multivariate Analysis ,Implant ,Permanent pacemaker ,business ,Follow-Up Studies - Abstract
Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 ± 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 ± 12.8%, STS score 9.4 ± 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.32–0.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.03–1.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. © 2011 Wiley Periodicals, Inc.
- Published
- 2011
25. An innovative abdominal wall repair technique for infected prosthesis: the Eskimo technique
- Author
-
Coccolini, F, Catena, F, Ansaloni, L, Neri, F, Gazzotti, F, Lazzareschi, D, Pinna, A, Pinna, AD, Coccolini, F, Catena, F, Ansaloni, L, Neri, F, Gazzotti, F, Lazzareschi, D, Pinna, A, and Pinna, AD
- Abstract
The use of meshes to repair incisional hernias has been shown to reduce the recurrence rate, though it may increase the risk of surgical site infection. This is one of the most feared and devastating complications of surgical abdominal wall repair. The aim of this work is to describe a new surgical technique that was used to treat two patients suffering from chronic prosthesis infection. Additionally, the outcome of this procedure will be analyzed in terms of its safety, subsequent site infection and recurrence prevention. Two case reports are presented. The procedure was based on a wide surgical excision of the infected prosthesis and the surrounding tissues, plus abdominal wall repair with biological prosthesis. Both patients experienced an uneventful postoperative course. Infection of the surgical site resolved following the procedure and, after a mean follow-up of 36 months, no recurrences of the incisional hernia had occurred. This unique surgical technique not only proved to be safe, but it also solved the chronic prosthesis infection through its use of radical excision, without any postoperative complications or recurrence. This technique confirmed that biological prostheses can be used safely and effectively for implantation in sites of infection.
- Published
- 2011
26. Built-in defect of a biological pericardial aortic prosthesis?
- Author
-
Buklas, Dimitrio, Massetti, Massimo, Neri, Eugenio, Chocron, Sidney, Massetti, Massimo (ORCID:0000-0002-7100-8478), Buklas, Dimitrio, Massetti, Massimo, Neri, Eugenio, Chocron, Sidney, and Massetti, Massimo (ORCID:0000-0002-7100-8478)
- Abstract
We report a case on an early complication of a biological pericardial tissue valve in the aortic position that required emergency replacement. One of the three leaflets of the valve was stuck open in a fixed-open position and would not unfold in diastole. This resulted in severe aortic insufficiency, diagnosed by standard postoperatory echocardiography and confirmed in the operating room.
- Published
- 2008
27. Mitral valve repair and transesophageal echocardiographic findings in a high-risk subgroup of patients with active, acute infective endocarditis
- Author
-
Senni, M, Merlo, M, Sangiorgi, G, Gamba, A, Procopio, A, Glauber, M, Ferrazzi, P, Senni M, Merlo M, Sangiorgi G, Gamba A, Procopio A, Glauber M, Ferrazzi P, Senni, M, Merlo, M, Sangiorgi, G, Gamba, A, Procopio, A, Glauber, M, Ferrazzi, P, Senni M, Merlo M, Sangiorgi G, Gamba A, Procopio A, Glauber M, and Ferrazzi P
- Abstract
Background and aim of the study: Limited data are available regarding the efficacy of mitral valve repair in patients affected by active, acute infective endocarditis. In addition, the predictivity of transesophageal echocardiography (TEE) for guiding the surgical decision-making process in these patients has not yet been reported. The study aim was to evaluate the long-term results of mitral valve repair and role of TEE in active, acute infective endocarditis. Methods: The study population consisted of patients affected by infective endocarditis of the mitral valve who underwent surgery. TEE was performed intra-operatively to guide the best surgical approach. All patients were followed up (mean 73 ± 8 months) after surgery. Results: Twenty-eight patients underwent surgery for infective endocarditis; of these, 13 had mitral valve repair for active, acute infective endocarditis and formed the basis of the study. Sensitivity, specificity, positive predictive value, negative predictive value of TEE in detecting the mechanism of mitral regurgitation were 87%, 100%, 100% and 92%, respectively. The predictivity test of TEE in guiding surgical strategy was 94%. All patients were alive at the time of follow up; 10 (77%) were in NYHA class I and three in class II (23%). Mitral regurgitation was severe in one patient (8%), moderate in three (23%), mild in four (31%), and absent in five (38%). No relapses of active infective endocarditis were observed during the follow up period. Conclusion: Mitral valve repair appears to be an effective treatment for active, acute infective endocarditis with mitral regurgitation and should be considered as a therapeutic strategy when surgery is contemplated. TEE has a fundamental role in the surgical decision-making process in these patients.
- Published
- 2001
28. Erratum: Processed bovine pericardium as patch angioplasty for carotid endarterectomy: A preliminary report
- Author
-
Biasi, G, Mingazzini, P, Baronio, L, Sampaolo, A, BIASI, GIORGIO MARIA, MINGAZZINI, PAOLO, Sampaolo, A., Biasi, G, Mingazzini, P, Baronio, L, Sampaolo, A, BIASI, GIORGIO MARIA, MINGAZZINI, PAOLO, and Sampaolo, A.
- Abstract
Although the routine use of a patch for closure of the arteriotomy after carotid endarterectomy is still debated, patch angioplasty is frequently used to avoid residual stenosis and to lower the incidence of later restenosis. Several materials are widely used for carotid patching, notably, autologous vein, Dacron and polytetrafluorethylene (PTFE). During recent years a heterologous stabilized graft made from bovine pericardium has been introduced. This paper reports the authors' experience of 52 carotid endarterectomies in which a patch of bovine pericardium was used to close the arteriotomy. The patients were followed with colour-duplex scanning over 12–30 months. This biograft did not require preclotting and proved to be easy to suture. Follow-up did not uncover any complications related to graft use. Although this is a preliminary report, it is concluded that bovine pericardium is a promising material for carotid patch angioplasty
- Published
- 1996
29. Mitral valve repair and transesophageal echocardiographic findings in a high-risk subgroup of patients with active, acute infective endocarditis
- Author
-
Senni, M., Merlo, M., Gabriela Sangiorgi, Gamba, A., Procopio, A., Glauber, M., Ferrazzi, P., Senni, M, Merlo, M, Sangiorgi, G, Gamba, A, Procopio, A, Glauber, M, and Ferrazzi, P
- Subjects
Bioprosthesis ,Adult ,Heart Valve Prosthesis Implantation ,Male ,Rupture, Spontaneous ,Rupture, Spontaneou ,Mitral Valve Insufficiency ,Settore MED/11 - Malattie dell'Apparato Cardiovascolare ,Settore MED/23 - Chirurgia Cardiaca ,Endocarditis, Bacterial ,Middle Aged ,Risk Assessment ,Acute Disease ,Humans ,Chordae Tendineae ,Female ,Bioprosthesi ,Echocardiography, Transesophageal ,Aged ,Human - Abstract
Background and aim of the study: Limited data are available regarding the efficacy of mitral valve repair in patients affected by active, acute infective endocarditis. In addition, the predictivity of transesophageal echocardiography (TEE) for guiding the surgical decision-making process in these patients has not yet been reported. The study aim was to evaluate the long-term results of mitral valve repair and role of TEE in active, acute infective endocarditis. Methods: The study population consisted of patients affected by infective endocarditis of the mitral valve who underwent surgery. TEE was performed intra-operatively to guide the best surgical approach. All patients were followed up (mean 73 ± 8 months) after surgery. Results: Twenty-eight patients underwent surgery for infective endocarditis; of these, 13 had mitral valve repair for active, acute infective endocarditis and formed the basis of the study. Sensitivity, specificity, positive predictive value, negative predictive value of TEE in detecting the mechanism of mitral regurgitation were 87%, 100%, 100% and 92%, respectively. The predictivity test of TEE in guiding surgical strategy was 94%. All patients were alive at the time of follow up; 10 (77%) were in NYHA class I and three in class II (23%). Mitral regurgitation was severe in one patient (8%), moderate in three (23%), mild in four (31%), and absent in five (38%). No relapses of active infective endocarditis were observed during the follow up period. Conclusion: Mitral valve repair appears to be an effective treatment for active, acute infective endocarditis with mitral regurgitation and should be considered as a therapeutic strategy when surgery is contemplated. TEE has a fundamental role in the surgical decision-making process in these patients.
30. European multicenter study with the Soprano valve for aortic valve replacement: one-year clinical experience and hemodynamic data
- Author
-
Fischlein T, Otero-Coto E, Werkkala K, Passerone G, GIUSEPPE MARINELLI, Tarkka MR, Feindt P, Perez de Isla L, Jl, Zamorano, Fischlein, Theodor, Otero-Coto, Eduardo, Werkkala, Kalervo, Passerone, Giancarlo, Marinelli, Giuseppe, Tarkka, Matti R, Feindt, Peter, Perez de Isla, Leopoldo, and Zamorano, Jose L
- Subjects
Male ,Reoperation ,Hemorrhage ,Postoperative Complications ,Thromboembolism ,Humans ,Endocarditi ,Hemodynamic ,Prospective Studies ,Bioprosthesi ,Aged ,Aged, 80 and over ,Bioprosthesis ,Heart Valve Prosthesis Implantation ,Endocarditis ,Hemodynamics ,Aortic Valve Stenosis ,Aortic Valve Stenosi ,Europe ,Prospective Studie ,Echocardiography ,Aortic Valve ,Heart Valve Prosthesis ,cardiovascular system ,Female ,Postoperative Complication ,Human - Abstract
During recent years, pericardial bioprostheses have gained widespread acceptance as cardiac valve substitutes. The study aim was to evaluate the early clinical and hemodynamic performance of the Sorin SopranoTM supra-annular aortic bioprosthesis, as used for aortic valve replacement (AVR).Between January 2004 and August 2006, a total of 501 patients (55% males; mean age 75 +/- 6.4 years) was prospectively enrolled into the study, which involved 10 European institutions. The indications for AVR were aortic stenosis in 91% of patients, aortic incompetence in 8%, and redo surgery in 1%. Preoperatively, 62% of the patients were in NYHA class III, and 12% in class IV. The mean prosthesis size was 21.4 +/- 1.8 mm. A non-everting technique was used in 88% of patients. Concomitant procedures were performed in 52% of cases (mainly coronary artery bypass grafts; 41%). The mean cross-clamp and cardiopulmonary bypass times were 70 +/- 27.2 min and 99 +/- 39.7 min, respectively. Doppler echocardiography performed at one and 12 months after surgery was evaluated by an independent core laboratory.Postoperatively, there were 25 early deaths (5%) and 13 late deaths, with an overall survival at one year of 92.9% (95% CI: 90.2-94.8) and freedom from valve-related death of 98.6% (95% CI: 97.5-99.6). After 12 months, most patients (87%) were in NYHA classes I-II. Actuarial freedoms from thromboembolism, bleeding, endocarditis and paraprosthetic leak at one year were 97.1% (CI: 95.1-98.2), 98.9% (CI: 97.4-99.5), 99.1% (CI: 97.7-99.7), and 99.6% (CI: 98.3-99.9), respectively. No events of thrombosis and structural valve deterioration (SVD) were observed. Subsequent echocardiographic evaluation showed low mean (11.1 +/- 5.1 mmHg at one year) and peak (19.5 +/- 8.9 mmHg at one year) transvalvular gradients, and a significant reduction in left ventricular mass, from 211 +/- 78.5 g at one month to 185 +/- 64.7 g at 12 months (p0.0001).After 12 months, the clinical outcome with the Soprano bioprosthesis, when used for AVR, was excellent. The bioprosthesis also showed good hemodynamic performance, with a significant reduction of left ventricular hypertrophy.