1. Three-Dimensional Color Doppler Echocardiographic Quantification of Tricuspid Regurgitation Orifice Area: Comparison with Conventional Two-Dimensional Measures
- Author
-
Tien-En Chen, Benjamin F. Wong, Sunil Mankad, Maurice Enriquez-Sarano, and Susan H. Kwon
- Subjects
Male ,medicine.medical_specialty ,Echocardiography, Three-Dimensional ,Regurgitation (circulation) ,Effective Regurgitant Orifice Area ,Sensitivity and Specificity ,Internal medicine ,Humans ,Medicine ,Radiology, Nuclear Medicine and imaging ,Aged ,Aged, 80 and over ,Mitral regurgitation ,Tricuspid valve ,Vena contracta ,Receiver operating characteristic ,business.industry ,Atrial fibrillation ,Middle Aged ,medicine.disease ,Tricuspid Valve Insufficiency ,Echocardiography, Doppler, Color ,medicine.anatomical_structure ,ROC Curve ,Cardiology ,Feasibility Studies ,Female ,Tricuspid Valve ,Cardiology and Cardiovascular Medicine ,business ,Body orifice - Abstract
Three-dimensional (3D) color Doppler echocardiography (CDE) provides directly measured vena contracta area (VCA). However, a large comprehensive 3D color Doppler echocardiographic study with sufficiently severe tricuspid regurgitation (TR) to verify its value in determining TR severity in comparison with conventional quantitative and semiquantitative two-dimensional (2D) parameters has not been previously conducted. The aim of this study was to examine the utility and feasibility of directly measured VCA by 3D transthoracic CDE, its correlation with 2D echocardiographic measurements of TR, and its ability to determine severe TR.Ninety-two patients with mild or greater TR prospectively underwent 2D and 3D transthoracic echocardiography. Two-dimensional evaluation of TR severity included the ratio of jet area to right atrial area, vena contracta width, and quantification of effective regurgitant orifice area using the flow convergence method. Full-volume breath-hold 3D color data sets of TR were obtained using a real-time 3D echocardiography system. VCA was directly measured by 3D-guided direct planimetry of the color jet. Subgroup analysis included the presence of a pacemaker, eccentricity of the TR jet, ellipticity of the orifice shape, underlying TR mechanism, and baseline rhythm.Three-dimensional VCA correlated well with effective regurgitant orifice area (r = 0.62, P.0001), moderately with vena contracta width (r = 0.42, P.0001), and weakly with jet area/right atrial area ratio. Subgroup analysis comparing 3D VCA with 2D effective regurgitant orifice area demonstrated excellent correlation for organic TR (r = 0.86, P.0001), regular rhythm (r = 0.78, P.0001), and circular orifice (r = 0.72, P.0001) but poor correlation in atrial fibrillation rhythm (r = 0.23, P = .0033). Receiver operating characteristic curve analysis for 3D VCA demonstrated good accuracy for severe TR determination.Three-dimensional VCA measurement is feasible and obtainable in the majority of patients with mild or greater TR. Three-dimensional VCA measurement is also feasible in patients with atrial fibrillation but performed poorly even with20% cycle length variation. Three-dimensional VCA has good cutoff accuracy in determining severe TR. This simple, straightforward 3D color Doppler measurement shows promise as an alternative for the quantification of TR.
- Published
- 2013
- Full Text
- View/download PDF