1. Test–Retest Reliability of Running Economy and Metabolic and Cardiorespiratory Parameters During a Multistage Incremental Treadmill Test in Male Middle- and Long-Distance Runners.
- Author
-
Brady, Aidan J., Roantree, Mark, and Egan, Brendan
- Subjects
- *
STATISTICAL correlation , *REPEATED measures design , *LONG-distance running , *PULMONARY gas exchange , *EXERCISE , *T-test (Statistics) , *RESEARCH funding , *DESCRIPTIVE statistics , *CARDIOPULMONARY system , *ENERGY metabolism , *RESPIRATORY quotient , *HEART beat , *BLOOD sugar , *STATISTICAL reliability , *PHYSICAL fitness , *LACTATES , *INTRACLASS correlation , *ONE-way analysis of variance , *EXERCISE tests , *ATHLETIC ability , *ANTHROPOMETRY , *DIETARY carbohydrates , *OXYGEN consumption , *CALORIMETRY , *DATA analysis software , *CONFIDENCE intervals - Abstract
This study investigated the test–retest reliability of running economy (RE) and metabolic and cardiorespiratory parameters related to endurance running performance using a multistage incremental treadmill test. On two occasions separated by 21–28 days, 12 male middle- and long-distance runners ran at 10, 11, 12, 13, and 14 km/hr for 8 min each stage, immediately followed by a ramp test to volitional exhaustion. Carbohydrate (10% maltodextrin solution) was consumed before and during the test to provide ∼1 g/min of exercise. RE, minute ventilation ( V ˙ E), oxygen consumption ( V ˙ O 2 ), carbon dioxide production ( V ˙ CO 2 ), respiratory exchange ratio (RER), heart rate (HR), ratings of perceived exertion (RPE), and blood glucose and lactate concentrations were recorded for each stage and at volitional exhaustion. Time-to-exhaustion (TTE) and peak oxygen consumption ( V ˙ O 2 peak) during the ramp test were also recorded. Absolute reliability, calculated as the coefficient of variation (CV) between repeated measures, ranged from 2.3% to 3.1% for RE, whereas relative reliability, calculated as the intraclass correlation coefficient (ICC), ranged from.42 to.79. V ˙ E , V ˙ O 2 , V ˙ O 2 peak , V ˙ CO 2 , RER, and HR had a CV of 1.1%–4.3% across all stages. TTE and RPE had a CV of 7.2% and 2.3%–10.8%, respectively, while glucose and lactate had a CV of 4.0%–17.8%. All other parameters, except for blood glucose, were demonstrated to have good-to-excellent relative reliability assessed by ICC. Measures of RE, V ˙ O 2 peak , and TTE were reliable during this two-phase multistage incremental treadmill test in a cohort of trained and highly trained male middle- and long-distance runners. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF