1. Evaluating the Effect of Design and Length of Implants on Primary Stability Using Resonance Frequency Analysis: An In Vitro Study
- Author
-
Gülbahar Ustaoğlu, Tuğçe Paksoy, Kerem Çağlar Gümüş, Başka Kurum, BAİBÜ, Diş Hekimliği Fakültesi, Periodontoloji Ana Bilim Dalı, Ustaoğlu, Gülbahar, and Gümüş, Kerem Çağlar
- Subjects
Materials science ,rezonans frekans analizi ,resonance frequency analysis ,Dentistry ,Rezonans Frekans Analizi ,In vitro study ,Short Implants ,Dental implantlar ,Dental Implants ,Acid etching ,business.industry ,Test equipment ,Dental implants ,Significant difference ,Implant design ,Resonance Frequency Analysis ,İn Vitro ,in vitro ,General Medicine ,Implant stability quotient ,kısa implantlar ,In Vitro ,Resonance frequency analysis ,Kısa İmplantlar ,Implant ,short implants ,business - Abstract
Background: Primary stability (PS) is dependent on the length and diameter of the implant, micro-morphology of the implant surface, implant design, surgical procedure, bone quantity, and quality. This study aimed to compare short and standard dental implants according to primary stability in bone type IV using Resonance frequency analysis (RFA) test equipment. Methods: Seventy two dental implants; sandblasting with large grit particles and acid etching (SLA) surface (Dentium®,SimpleLine II, Seoul, Korea), SLActive surface- (Straumann Roxolid®, Basel, Switzerland), Resorbable blast media (RBM) surface- (Implance®, Trabzon, Turkey) with very short (4-mm length), short (6-mm length) and standard dental implants (10-mm length) were placed in bovine cow ribs with bone quality similar to a type IV human bone. RFA was performed to evaluate the primary stability. One-way ANOVA test was used to compare the groups ve different groups were assessed with the post hoc Tukey test. Results: Implant stability quotient (ISQ) measurements of 4-mm and 6-mm length implants were similar however, 10-mm-length implants showed statistically difference inter-groups. SLActive surface in 10-mm-length implant group showed highest ISQ value (p, Amaç: Primer stabilite (PS), implantın uzunluğuna ve çapına, implant yüzeyinin mikro morfolojisine, implant tasarımına, cerrahi prosedüre, kemik miktarına ve kalitesine bağlıdır. Bu çalışmanın amacı, çok kısa, kısa ve standard dental implantları Tip IV kemikte primer stabilitelerine göre Rezonans Frekans Analizi (RFA) test ekipmanı kullanarak karşılaştırmaktır. Gereç ve Yöntemler: Yetmiş iki dental implant; Large grit kumlanmış ve asitlenmiş (sandblasting with large grit particles and acid etching, SLA) (Dentium®, SimpleLine II, Seul, Kore), SLActive yüzey- (Straumann Roxolid®, Basel, İsviçre), Resorbable blast media (RBM) yüzey- (Implance®, Trabzon, Türkiye) çok kısa (4 mm uzunluğunda), kısa (6 mm uzunluğunda) ve standard dental implantlar (10 mm uzunluğunda) insan tip IV kemiğine benzer kemik kalitesine sahip sığır türü kaburgaya yerleştirildi. Grupları karşılaştırmak için tek yönlü ANOVA testi kullanıldı ve farklı gruplar post hoc Tukey testi ile değerlendirildi. Bulgular: Dört ve 6 mm uzunluktaki implantların İmplant Stabilite Katsayısı (Implant stability quotient, ISQ) ölçümleri benzerdi, ancak 10 mm uzunluktaki implantlarda gruplar arasında istatistiksel olarak anlamlı fark gözlendi. On mm uzunluğundaki implant grubunda SLActive yüzey en yüksek ISQ değerini gösterdi (p
- Published
- 2020