1. Voice Rehabilitation by Voice Prostheses After Total Laryngectomy: A Systematic Review and Network Meta-Analysis for 11,918 Patients
- Author
-
Tawfik, Gehad Mohamed, Makram, Omar Mohamed, Zayan, Ahmad Helmy, Ghozy, Sherief, Eid, Peter Samuel, Mahmoud, Mona Hanafy, Abdelaal, Abdelaziz, Abdelghany, Seif Mahmoud, Sayed, Ahmed M., Sang, To Kim, Kassem, Mahmoud, Ho, Quoc Le Minh, Eltanany, Heba Hussien, Ali, Amira Farghaly, Hassan, Osama Gamal, Elsherbiny, Khaled Essam, Shafik, Amr G., Hirayama, Kenji, and Huy, Nguyen Tien
- Subjects
Laryngectomy -- Patient outcomes ,Speech therapy -- Methods ,Artificial larynx -- Usage ,Health - Abstract
Purpose: Our aim was to assess the different voice prostheses (VPs) to identify the most efficient, safest, patient-tailored, longest lifetime, and inexpensive VPs and assess the different factors affecting their quality. Method: In September 2017, 15 databases were searched to include all randomized controlled trials. A new search was done in May 2019 to include all other study design articles, which include all the new-era VPs subtypes. Network meta-analysis (NMA) was applied to all 27 outcomes, besides NMA overall and partial order setting was done by using Hasse scatter plots. p values were used in NMA, where the best VPs are approaching one and the least approaches zero. Meta-analysis was done for the rest of the outcomes. Results: Two hundred one articles were eligible for inclusion in our study (N = 11,918). Provox-2 was significantly the most efficient and safest device concerning the most patient preference (odds ratio [OR] = 33.88 [0.65, 1762.24]; p = .92), the least dislodgement (risk ratio [RR] = 0.27 [0.13, 0.57]; p = .79), the least airflow resistance (RR = 0.42 [0.08, 2.11]; p = .84), the least granulation formation (RR = 0.73 [0.02, 26.32]; p = .60), and the least VPs' inaccurate size (RR = 0.77 (0.23, 2.61); p = .66). Heat and moisture exchanger addition showed a significant increase in maximum phonation time and breathing experience, with p values (1 and .59), respectively. While heat and moisture exchanger addition showed a significant decline in stoma cleaning frequency, coughing frequency, forced expectoration, sputum production, sleeping problems, and loosening of adhesive, with p values (.99, .72, .69, .96, 1, and 0.96), respectively, Groningen low resistance and Nijdam were considered the worst devices with both overall mean p value of .44. Conclusions: Provox-2 is considered the best choice as being the most preferable for patients, with the least airflow resistance, dislodgment, granulation formation, and prosthesis inaccurate size. Groningen low resistance and Nijdam were considered the worst devices according to our analysis. Supplemental Material: https://doi.org/10.23641/asha. 14802903, Laryngeal cancer is the most common malignancy of the head and neck, ranking the 19th globally with an estimated 13,150 new cases in the United States in 2018, as reported [...]
- Published
- 2021
- Full Text
- View/download PDF